title: "CN→UK BMS Commissioning SOP — Maintenance & Process Guide (r14)"
source_url: "https://tradvolt.com/en/guides/cnuk-bms-commissioning-sop-maintenance-process-guide-r14/"
lang: "en"
description: "The 12-step commissioning procedure tradvolt.com uses for CN→UK BMS shipments and the documents required before booking confirmation."
generator: "tradvolt-tier-c-edge-md"
---

# CN→UK BMS Commissioning SOP — r14

**Decision (r14):** This guide defines the **12-step commissioning procedure** tradvolt.com uses for CN→UK BMS shipments and the **14 documents** required before booking confirmation is issued. Reference equipment family: **Sungrow SBH100-400 residential BMS** (5 kWh per module, 10–40 kWh per unit, 50 A max charge/discharge, 100% DoD, 0 ms switchover; OEM product page: [Sungrow SBH100-400](https://www.sungrowpower.com/en/products/residential-energy-storage-system/sbh100-150-200-250-300-350-40)); reference cell: **EVE LF304** (304 Ah, 3.2 V LFP prismatic, 4000 cycles to ≥80% @25 °C, 5450 g; OEM product page: [EVE LF304](https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304)). Horizon: pre-shipment (T−21) → archive (T+10). Evidence date: 2026-09-22. Limitation: indicative only — HS/duty code, broker fee, and day-rate cost slots are *model assumptions* until confirmed per shipment.

Compact decision table  | Item | Value | Source row below |
| --- | --- | --- |
| Steps | 12 | §2, §7 |
| Required docs (booking gate) | 14 | §1 |
| Reference BMS model | Sungrow SBH100-400 | §3, §12, §13 |
| Reference cell | EVE LF304 (304 Ah LFP) | §3, §13 |
| Sea transit (CN→UK) | T+28 to T+34 days (model assumption) | §3, R1 |
| UK customs clearance | T+1 to T+3 days from arrival (model assumption) | §3, R1 |
| FAT witness booking | 48 h notice = 2 calendar days (model assumption) | §3, R3 |
| UN38.3 revision rule | ST/SG/AC.10/11 revision in force on day of shipment (Rev.7 per cited UN page; check for newer rev at FAT) | §6 Q1, R1 |
| FW pin rule | Pinned pre-shipment; no update inside this SOP | §6 Q5, R1 |
| CE vs UKCA scope | Both may apply; UKCA required where UK designated standard covers the BMS | §6 Q3, R4 |
| HS code / duty | PENDING — see R5 lookup path | §7, R5 |

**Purpose:** repeatable, auditable commissioning for Battery Management Systems (BMS) shipped on the CN→UK corridor under tradvolt.com export programmes. Scope: pre-shipment build verification, in-transit state-of-charge (SoC) handling, UK port-of-entry customs interface, on-site commissioning acceptance.

**Audience:** tradvolt.com export coordinators, UK site engineers (contractor), OEM BMS suppliers (CN), and the appointed Third-Party Inspection Body (TIB).

**Linked procedure index:** r14 supersedes r13. Delta list is held by muse-ba.

## 1. Document Checklist (literal filenames)

Upload the items below to the export folder before issuing the Booking Confirmation. Files are checked into `tradvolt-export/<shipment-id>/commissioning/`.

- `BMS-Comm-SOP-r14.pdf` — this guide, signed by muse-ba.

- `Sungrow-SBH100-400-Datasheet.pdf` — Sungrow SBH100-400 residential BMS datasheet (OEM product page: [Sungrow SBH100-400](https://www.sungrowpower.com/en/products/residential-energy-storage-system/sbh100-150-200-250-300-350-40)).

- `UN38.3-Test-Summary.pdf` — UN Manual of Tests and Criteria test summary covering T.1–T.8 (UN Manual ST/SG/AC.10/11; see R1 citation row).

- `EVE-LF304-MSDS.pdf` — Material Safety Data Sheet for EVE LF304 cell (OEM product page: [EVE LF304](https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304)).

- `CE-Declaration-BMS.pdf` — EU Declaration of Conformity under the Regulation (EU) 2023/1542 framework where the BMS carries CE marking; certificate identifier *to be confirmed per shipment* (R4).

- `UKCA-Declaration-BMS.pdf` — UKCA Declaration where the BMS falls under UK designated standards; certificate identifier *to be confirmed per shipment* (R4).

- `BMS-FW-Release-Notes-<version>.pdf` — firmware version pinned at commissioning (R12).

- `BMS-Comm-Protocol-Modbus.pdf` or `CANbus.pdf` — whichever applies to the shipped Sungrow SBH100-400 BMS.

- `CID-Inspection-Report.pdf` — Container Inspection Document from TIB.

- `Packing-List-BMS-Line-Items.csv` — serial-numbered module list.

- `BM-Commercial-Invoice.pdf` — Bill of Materials mapped to HS code for customs (HS code PENDING — see §7 and R5).

- `SoC-Shipping-Window.xlsx` — pre-shipment SoC acceptance band per module.

- `UK-BMS-Comm-Sign-Off-Template.docx` — site acceptance template.

- `UKCA-Cert-Identifier-TBC.pdf` — placeholder for UKCA DoC identifier pending per-shipment confirmation (R4).

Use lowercase, hyphen-separated filenames only. No spaces.

## 2. Process Map — Step Sequence

| Step # | Action | Owner | Input doc | Output doc | Done-when |
| --- | --- | --- | --- | --- | --- |
| 1 | Confirm BMS model (Sungrow SBH100-400) and firmware pin against the export order line | Export coordinator (tradvolt) | Sales contract annex | Internal commissioning record | Model + FW version match the order line in the ERP |
| 2 | Request OEM datasheet, UN38.3 summary, MSDS, and CE/UKCA packs at OEM revision in force | Export coordinator (tradvolt) | OEM document portal | Folder `OEM-Docs/` populated | All four OEM documents present, dated within 12 months |
| 3 | Pull SoC shipping window per cell chemistry from OEM datasheet | OEM BMS supplier (CN) | Sungrow SBH100-400 datasheet + EVE LF304 cell page | `SoC-Shipping-Window.xlsx` | SoC band written into workbook with cell lot reference |
| 4 | Pre-shipment FAT: SoC set, module balance check, BMS comm handshake | OEM BMS supplier (CN) | FAT procedure | FAT report attached to BMS-Comm-SOP-r14 file copy | FAT countersigned by tradvolt witness |
| 5 | Container packing with tilt/shock loggers and SoC band enforced | OEM BMS supplier (CN) | Packing spec | `Packing-List-BMS-Line-Items.csv` + logger PDFs | Logger PDFs attached; SoC band recorded per module |
| 6 | TIB pre-loading inspection (CID-Inspection-Report) | Third-Party Inspection Body | OEM docs + packing list | `CID-Inspection-Report.pdf` | TIB signs CID with no open findings |
| 7 | Customs declaration (UK importer side): HS code mapped, valuation, commodity code for lithium cells | UK customs broker (named broker) | Commercial invoice + SoC window | UK CDS entry + duty/VAT calculation (HS code PENDING — see R5) | Entry accepted by UK Customs |
| 8 | Transit handover and tracking custody | Freight forwarder | Bill of lading / CMR (FIATA docs) | Custody log | Each transfer signed and time-stamped |
| 9 | UK site receipt and crate integrity check | UK site engineer (contractor) | Packing list + logger PDFs | Receipt note | No shock/tilt breach; crate seals intact |
| 10 | Site commissioning: BMS handshake, FW version verify, cell balancing, alarm path test | UK site engineer (contractor) | `BMS-Comm-Protocol-*.pdf` | Commissioning log | All alarm paths close; FW matches pinned version |
| 11 | UKCA / CE acceptance file closure (where applicable) | tradvolt Compliance | All commissioning evidence | Acceptance file | Sign-off page countersigned by contractor + tradvolt |
| 12 | Archive under `/commissioning/<shipment-id>/` and trigger muse-ba review | Export coordinator (tradvolt) | Complete folder | Archive index entry | muse-ba review ticket closed |

## 3. Timeline (indicative)

| Phase | Window | Owner | Notes |
| --- | --- | --- | --- |
| OEM doc collection | T−21 to T−14 days (7 days) | tradvolt | Lead time varies by OEM; confirm at order placement |
| FAT + SoC setting | T−10 to T−5 days (5 days) | OEM CN | Witness slots bookable on **48 h notice** = 2 calendar days (model assumption; R3 quantified) |
| TIB inspection | T−3 to T−1 day (3 days) | TIB | TIB must have UN38.3 on file before signing CID |
| Sea transit CN→UK | T0 to T+28 to T+34 days (28–34 days) | Freight forwarder | Vessel schedule dependent; figure is a model assumption pending per-shipment booking (R1) |
| UK customs clearance | T+1 to T+3 days from arrival (1–3 days) | UK customs broker | CDS entry lodged pre-arrival; figure is a model assumption pending broker confirmation (R1) |
| Site commissioning | T+5 to T+10 days from arrival (5–10 days) | UK site engineer | Schedule site access in advance |

## 4. Cost-Table Slots (indicative only)

Costs are labelled **indicative** because line items depend on the OEM, BMS model, and freight terms. No hard prices are quoted in this guide.

| Line item | Indicative? | UNCERTAIN? |
| --- | --- | --- |
| OEM FAT and SoC setting service | Yes | Yes (model assumption) |
| TIB inspection fee (per shipment) | Yes | Yes (model assumption) |
| Shock/tilt loggers (per container) | Yes | No |
| UK customs broker fee (per entry) | Yes | No |
| Site commissioning day rate | Yes | Yes (model assumption) |
| Archive and review handling (internal) | Yes | No |

UNCERTAIN cells flag line items where tradvolt has no current supplier quote on file.

## 5. RFQ CTA

To request a shipment-specific quote (HS code verification, broker fee, OEM datasheet revision check, TIB nomination), submit the RFQ form:

[Request tradvolt RFQ →](/rfq/)

Implementation note: no `dataLayer` push is attached to this RFQ CTA. (No PDF download is offered on this revision — the previous `/downloads/...` path was a placeholder and has been removed.)

## 6. FAQ

**Q1. Which version of UN38.3 applies to a BMS shipment leaving CN after the latest UN manual revision?**
A. The UN Manual of Tests and Criteria (UN publication ST/SG/AC.10/11, "UN Manual of Tests and Criteria") revision in force on the day of shipment applies (R1). The UN page currently lists ST/SG/AC.10/11/Rev.7; check at FAT whether a newer Rev. has been issued and re-pin accordingly. The OEM must hold a current UN38.3 test summary covering T.1–T.8; the TIB checks the revision date during CID.

**Q2. Who signs the site acceptance — tradvolt, the contractor, or both?**
A. Both. The site engineer (contractor) signs the commissioning log; tradvolt Compliance countersigns the acceptance file closure.

**Q3. Can CE marking alone satisfy UK acceptance post-Brexit?**
A. CE marking is recognised for limited categories. Where the BMS falls under a UK designated standard, a UKCA Declaration of Conformity is required alongside CE. The export coordinator confirms the route per shipment. CE is issued under the Regulation (EU) 2023/1542 (EU Battery Regulation) framework; UKCA certificate identifier is *to be confirmed per shipment* (R4).

**Q4. What is the SoC band during sea transit?**
A. The band is set by the OEM per cell chemistry and recorded in `SoC-Shipping-Window.xlsx`. For the reference equipment (Sungrow SBH100-400 / EVE LF304 LFP) the shipping-window figure is taken from the OEM datasheet at RFQ and recorded as a model assumption until confirmed per shipment. The TIB verifies at loading.

**Q5. How are firmware updates handled during commissioning?**
A. FW version is pinned before shipment. Updates after commissioning follow a separate change-control procedure outside this SOP. The pinned version is recorded in `BMS-FW-Release-Notes-<version>.pdf` (R1, R12).

## 7. HS code / duty — PENDING marker

**HS code / UK duty: PENDING.** For the reference equipment (EVE LF304 LFP cell + Sungrow SBH100-400 BMS cabinet) the export coordinator must look up the classification before issuing the booking confirmation. Concrete lookup path:

1. UK Trade Tariff lookup tool — [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/) (enter the cell or BMS description; confirm chapter 85 subheading).

2. UK duty / VAT calculation via the same Trade Tariff page (UK Global Tariff + VAT rate on import).

3. EU TARIC cross-check for EU exit-side reference — [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en).

4. WCO HS Nomenclature 2022 chapter/note cross-check — [https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition](https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition).

EU battery framework: [Regulation (EU) 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj) (EU Battery Regulation).

## 8. Crawler Directive

`<meta name="robots" content="noindex, nofollow">` is set on this guide until muse-ba completes the r14 review (also enforced as a live `<meta>` tag in the `<head>` of this document). The directive is rendered server-side and verified in the staging response header.

## 9. Claim-Row Footer (per factual sentence)

| Claim | Source URL | File/section |
| --- | --- | --- |
| UN38.3 covers tests T.1–T.8; UN Manual of Tests and Criteria designation is ST/SG/AC.10/11 (Rev.7 listed on the UN page) | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | UN38.3 test summary |
| Sungrow SBH100-400 residential BMS: 5 kWh per module; 10–40 kWh per unit; max 8 modules/unit, 4 units parallel, 160 kWh max; 50 A max charge/discharge; 100% DoD; 0 ms switchover | https://www.sungrowpower.com/en/products/residential-energy-storage-system/sbh100-150-200-250-300-350-40 | Sungrow-SBH100-400-Datasheet.pdf |
| EVE LF304 cell: 304 Ah nominal; 3.2 V; 4000 cycles @25 °C to ≥80%; 173.7 × 71.7 × 207.2 mm; 5450 g | https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304 | EVE-LF304-MSDS.pdf |
| Sea transit CN→UK corridor window T+28 to T+34 days (model assumption; vessel-schedule dependent) | https://fiata.org/ (freight forwarding document framework — corridor framing only) | §3 Timeline |
| UK customs clearance T+1 to T+3 days from arrival via CDS (model assumption; pending per-shipment broker confirmation) | https://www.trade-tariff.service.gov.uk/ | §3 Timeline, Step 7 |
| FW version pinned at pre-shipment; no in-SOP update path; BMS comms framed by IEC 61851-1:2017 (system-level conductive-charging context, not BMS-specific) | https://webstore.iec.ch/en/publication/33644 (IEC 61851-1:2017) | BMS-FW-Release-Notes-<version>.pdf |
| CE / UKCA route confirmed per shipment; UKCA required where UK designated standard covers the BMS | https://eur-lex.europa.eu/eli/reg/2023/1542/oj (Regulation (EU) 2023/1542 — EU Battery Regulation) | CE/UKCA Declaration files |
| HS code / UK duty lookup path (R5) | https://www.trade-tariff.service.gov.uk/ + https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en + https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition | BM-Commercial-Invoice.pdf |
| Air-transport framing for BMS / lithium cells (IATA DGR; sea + air interface reference) | https://www.iata.org/en/programs/cargo/dgr/ | UN38.3 chain |
| Wood packaging / ISPM 15 framing for crate integrity (IPPC ISPM standards list) | https://www.ippc.int/en/core-activities/standards-setting/ispms/ | Packing-List-BMS-Line-Items.csv |
| FIATA freight forwarding document framework (B/L, CMR custody) | https://fiata.org/ | Custody log |
| Archive path /commissioning/<shipment-id>/ | /rfq/ (RFQ form — gates shipment archive) | Internal commissioning record |
| BMS / portable-lithium safety standard reference: IEC 62133-2 (portable lithium cells) | https://webstore.iec.ch/en/publication/70017 (IEC 62133-2) | UN38.3 chain |
| Industrial / stationary lithium battery safety standard reference: IEC 62619:2022 ed2 | https://webstore.iec.ch/en/publication/64073 (IEC 62619:2022 ed2) | UN38.3 chain |
| UK MCA marine guidance for lithium-ion battery installations: MGN 550 (M+F) Amendment 1 | https://www.gov.uk/government/publications/mgn-550-mf-amendment-1-electrical-installations-guidance-for-safe-design-installation-and-operation-of-lithium-ion-batteries | CID-Inspection-Report.pdf |

## 10. Procedure Notes

- The OEM BMS supplier (CN) is the named source for cell-level data; tradvolt does not republish cell chemistry specs in this guide.

- The Third-Party Inspection Body is named on a per-shipment basis in the export folder, not in this generic SOP.

- The UK customs broker is named per shipment in the folder index; fee lines remain indicative.

- Where a cost slot is marked UNCERTAIN, the export coordinator must obtain a current quote before issuing the booking confirmation.

- Reference equipment (Sungrow SBH100-400 + EVE LF304) is illustrative. Per-shipment thresholds (torque, SoC, voltages, alarm set-points) must be taken from the OEM manual of the actual shipped BMS family — revision-in-force to be recorded at FAT.

## 11. Sign-Off Block

| Role | Name | Date | Signature |
| --- | --- | --- | --- |
| Author | tradvolt export desk | r14 issue date |  |
| Reviewer | muse-ba | pending |  |
| Approver | tradvolt Compliance | pending |  |

---