# CN→ZA Cable Bend Radius Maintenance & Process Guide

Slug: `/guides/cn-za-cable-bend-radius-r14/` · TradVolt · Maintenance & process sequence · Indicative costing only   **Verdict — 1 compliance rule:** Bend radius must be ≥ N × OD, where N is the multiplier stated on the cable OEM datasheet for the exact part number installed and OD is the cable outer diameter printed in that datasheet. Working reference for two real, publicly marketed single-core PV DC cables: **Lapp Ölflex Solar XLR-R 1×6 mm²** (fixed install = 4×OD, dynamic = 5×OD, per the manufacturer product family page) and **Prysmian Prysun 2.0 PV1-F** (fixed install = 4×OD, dynamic = 5×OD, per the manufacturer product family page). A measured radius below N×OD is a non-conformance and is flagged in Step 3. Sign-off: QA Lead with Install Supervisor countersign (Step 5). Equipment: PV DC string cable on CN→ZA solar PV export corridor. Horizon: installation + periodic re-inspection (Steps 1–8). Evidence date: 2024–2025 OEM product family pages (see §9 claim rows). Limitation: indicative costing only; HS/duty rows are PENDING live SARS and China Customs lookup; any slot without a named source is flagged UNCERTAIN or treated as a model assumption.

| Decision rule | Equipment / cable family | Horizon | Evidence date | Limitation |
| --- | --- | --- | --- | --- |
| Bend radius ≥ N×OD per OEM datasheet | PV DC string cable — Lapp Ölflex Solar XLR-R 1×6 mm²; Prysmian Prysun 2.0 PV1-F | CN→ZA solar PV export corridor; installation + periodic re-inspection (Steps 1–8) | 2024–2025 OEM product family pages (see §9 claim rows) | Indicative costing only; HS/duty rows PENDING live SARS & China Customs lookup; values without a named source flagged UNCERTAIN / model assumption |

**Editorial notice:** This guide is a maintenance/process sequence for cable bend radius compliance on the China → South Africa green-tech export corridor. All cost slots are labelled **INDICATIVE**. Duty rates are marked PENDING pending live SARS and China Customs lookup. No OEM, certification body, regulator or customs value has been invented; figures shown without a named source are flagged **UNCERTAIN** or treated as model assumptions. Bend-radius multipliers cited here are taken from the cable manufacturer's published product family page; treat as a **model assumption** pending confirmation against the printed datasheet shipped with the reel at goods-in.   [Request Quote (RFQ)](/rfq/) Download Checklist (PDF)

## 1. Purpose & Scope

This guide sequences the maintenance and verification activities required to keep *cable bend radius* within OEM-stated minimums along a China (CN) → South Africa (ZA) solar PV export corridor. It is intended for use by EPC subcontractors, QA inspectors and O&M leads during installation, commissioning and the periodic re-inspection cycle. Bend radius values referenced are **multipliers of cable outer diameter (OD)** as published by the cable OEM on the relevant product family page and product datasheet — for the Lapp Ölflex Solar XLR-R 1×6 mm² and the Prysmian Prysun 2.0 PV1-F (see §9 claim rows). Where a project specifies a stricter corridor value (for example to satisfy an EPC employer's specification), that stricter value governs and supersedes the OEM datasheet floor.

## 2. Step-by-Step Maintenance & Process Sequence

| Step # | Action | Owner | Input Doc | Output Doc | Done-when |
| --- | --- | --- | --- | --- | --- |
| 1 | Confirm cable family and datasheet bend radius (record OEM part number + datasheet revision ID) | QA Lead | Lapp Ölflex Solar XLR-R 1×6 mm² product family page or Prysmian Prysun 2.0 PV1-F product family page | Bend-radius reference sheet | Multiplier (e.g., 4×OD fixed, 5×OD dynamic) recorded per cable type from OEM product page; printed datasheet (shipped on reel) cross-checked at goods-in |
| 2 | Record route profile and OD measurements (OD value taken from the OEM datasheet for the installed part number) | Site Engineer | Route survey, OD measurement log | Route profile sheet | OD, route class (tray/conduit/burial/riser) and ambient range logged per segment |
| 3 | Compute minimum bend radius per segment (minimum = N×OD per OEM datasheet) | QA Lead | Reference sheet + route profile | Compliance calculation sheet | Minimum bend radius calculated; any segment where measured radius < N×OD flagged as non-conformance |
| 4 | Inspect pull points and support spacing | Install Supervisor | Pull-point inspection checklist | Pull-point report | Sheave, roller, cleat and support spacing verified against OEM guidance |
| 5 | Apply installation record and sign-off (QA Lead sign-off; Install Supervisor countersign) | QA Lead | Compliance sheet + photos | As-built bend-radius record | As-built marked, photographic evidence attached, installer signed |
| 6 | Schedule periodic re-inspection cadence | O&M Lead | OEM warranty, site environment | Re-inspection schedule | Interval set; thermal-cycling segments flagged for shorter interval |
| 7 | Compile documentation pack for handover | Project Engineer | Steps 1–6 outputs | Maintenance dossier | Dossier reviewed against document checklist (see §3) and lodged |
| 8 | Archive dossier and notify TradVolt / employer | Document Controller | Maintenance dossier | Archive index entry | Index entry created, retention period set, stakeholders notified |

## 3. Document Checklist

The following literal filenames are expected in the maintenance dossier. Filenames must match exactly for downstream QA tooling. A printable checklist containing this list is available above as Download Checklist (PDF).

- `CNZA-R14-DS-OEM-cable-datasheet.pdf` — OEM datasheet PDF for the exact part number installed (for the Lapp Ölflex Solar XLR-R 1×6 mm² or the Prysmian Prysun 2.0 PV1-F as supplied on the reel)

- `CNZA-R14-REF-bend-radius-reference-sheet.xlsx`

- `CNZA-R14-RTE-route-profile-sheet.pdf`

- `CNZA-R14-CALC-compliance-calculation-sheet.xlsx`

- `CNZA-R14-PUL-pull-point-report.pdf`

- `CNZA-R14-ASB-as-built-bend-radius-record.dwg`

- `CNZA-R14-PHT-photo-evidence-folder.zip`

- `CNZA-R14-SCH-re-inspection-schedule.xlsx`

- `CNZA-R14-DOS-maintenance-dossier.pdf`

- `CNZA-R14-IDX-archive-index-entry.csv`

## 4. Timeline (Indicative)

| Phase | Activity | Indicative duration |
| --- | --- | --- |
| Day 1 | Steps 1–2: datasheet pull, route survey | 1 working day |
| Day 2–3 | Steps 3–4: calculations and pull-point inspection | 2 working days |
| Day 4 | Step 5: as-built sign-off | 1 working day |
| Day 5–7 | Step 6: schedule and stakeholder review | 3 working days |
| Day 8–10 | Steps 7–8: dossier compilation and archive | 3 working days |

Total indicative cycle: **~10 working days** from datasheet pull to archived dossier, excluding any non-conformance rework loops. Durations are **INDICATIVE** pending project scale.

## 5. Indicative Cost Table

All slots below are labelled **INDICATIVE**. TradVolt does not publish hard prices on guides; final figures are issued against an RFQ response.

| Cost slot | Description | Value (USD) | Status |
| --- | --- | --- | --- |
| C-01 | QA Lead time, datasheet pull & reference sheet | INDICATIVE | UNCERTAIN — not OEM-published |
| C-02 | Site Engineer route survey & OD log | INDICATIVE | UNCERTAIN — not OEM-published |
| C-03 | Compliance calculation effort | INDICATIVE | UNCERTAIN — not OEM-published |
| C-04 | Pull-point / sheave inspection | INDICATIVE | UNCERTAIN — not OEM-published |
| C-05 | As-built record & sign-off | INDICATIVE | UNCERTAIN — not OEM-published |
| C-06 | Periodic re-inspection (per cycle) | INDICATIVE | UNCERTAIN — not OEM-published |
| C-07 | Dossier compilation & archive | INDICATIVE | UNCERTAIN — not OEM-published |

## 6. HS Code & Duty Block (PENDING)

| Item | HS code (indicative) | Duty rate | Status |
| --- | --- | --- | --- |
| PV DC string cable (PV1-F / H1Z2Z2-K family, e.g., Lapp Ölflex Solar XLR-R, Prysmian Prysun 2.0 PV1-F) | 8544.60 | PENDING | Awaiting live SARS & China Customs lookup |
| LV AC power cable (armoured) | 8544.42 | PENDING | Awaiting live SARS & China Customs lookup |
| Cable glands / accessories | 8547.90 | PENDING | Awaiting live SARS & China Customs lookup |

**Lookup:** South African duties to be confirmed against the live SARS tariff query result page for the actual HS subheading at the time of export (SARS — South African Revenue Service); China export-side duties to be confirmed against the GACC Online Customs live result page for the actual HS subheading at the time of export. HS subheading references per the WCO Harmonized System 2022 nomenclature — Chapter 85 (8544.60, 8544.42, 8547.90). **Disclaimer:** HS classifications above are indicative starting references only and do not constitute a binding tariff ruling. Final classification must be confirmed by a licensed customs practitioner against the actual consignment, including any applicable anti-dumping, safeguard or preference-eligibility overlays (e.g., AGOA, SADC, China–Africa preferential arrangements as in force at the time of export).

## 7. FAQ

**Q1. What is "minimum bend radius" and why does it matter?**
It is the smallest radius a cable may be bent around without damaging its conductor, insulation or sheath. Bending tighter than the OEM-stated minimum can degrade insulation, increase sheath stress, accelerate ageing and void warranty. The multiplier (for example 4×OD for fixed installation, 5×OD for dynamic / moving) is set by the cable OEM and published on the product family page and on the printed datasheet shipped on the reel — for the Lapp Ölflex Solar XLR-R 1×6 mm² (4×OD fixed / 5×OD dynamic, model assumption pending confirmation against the printed datasheet) and the Prysmian Prysun 2.0 PV1-F (4×OD fixed / 5×OD dynamic, model assumption pending confirmation against the printed datasheet).   **Q2. Is 4×OD a universal rule?**
No. 4×OD is a common convention for fixed single-core PV DC cables, but values vary by cable family, insulation compound and installation class. Always use the value printed on the OEM datasheet for the exact part number being installed; if in doubt, contact the manufacturer for written guidance.   **Q3. How does the CN→ZA corridor affect bend radius practice?**
The corridor introduces long sea-freight reels, repeated handling at ports and variable ambient temperatures on the South African site. None of these alter the OEM minimum, but they do affect inspection cadence: thermal-cycling segments should be re-inspected more frequently than stable indoor trays.   **Q4. Who signs off the bend-radius record?**
Sign-off belongs to the QA Lead named in Step 5 of the sequence table, with the Install Supervisor countersign. For utility-scale projects an independent employer's engineer may also countersign.   **Q5. Can I skip steps if the run is short?**
No. The sequence is designed to produce an auditable dossier regardless of run length. Short runs reduce calculation time but not the documentation obligations; skipping steps breaks the chain of evidence and may jeopardise warranty and insurance positions.

## 8. CTA Block

[Request Quote (RFQ)](/rfq/) Download Checklist (PDF)

## 9. Claim-Row Footer

| Claim | Source URL | File / section |
| --- | --- | --- |
| Lapp Ölflex Solar XLR-R 1×6 mm² — minimum bend radius 4×OD (fixed installation), 5×OD (dynamic). Manufacturer: Lapp. Treated as **model assumption** pending confirmation against the printed datasheet shipped on the reel. | https://www.lapp.com/products/oe-flex-solar-xlr-r.html (Lapp Ölflex Solar XLR-R product family page) | §2, Step 1 |
| Prysmian Prysun 2.0 PV1-F — minimum bend radius 4×OD (fixed) / 5×OD (dynamic). Manufacturer: Prysmian. Treated as **model assumption** pending confirmation against the printed datasheet shipped on the reel. | https://www.prysmian.com/en/products-and-solutions/prysmian-cables-for-solar-applications.html (Prysmian cables for solar applications product family page) | §2, Step 1 |
| HS subheading 8544.60 — "Insulated wire, cable and other electric conductors… other electric conductors, for a voltage exceeding 1,000 V" — starting reference for PV DC string cable. | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022.aspx (WCO Harmonized System 2022 nomenclature — Chapter 85 / 8544.60) | §6 |
| HS subheading 8544.42 — "Other electric conductors for a voltage not exceeding 1,000 V… with connectors" — starting reference for LV AC armoured cable with fitted connectors. | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022.aspx (WCO Harmonized System 2022 nomenclature — Chapter 85 / 8544.42) | §6 |
| HS subheading 8547.90 — "Insulating fittings for electrical machines, appliances or equipment… other" — starting reference for cable glands / accessories. | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022.aspx (WCO Harmonized System 2022 nomenclature — Chapter 85 / 8547.90) | §6 |
| South African duty rates to be confirmed against the live SARS tariff query result page returned for the actual HS subheading at time of export. | https://www.sars.gov.za/ (SARS — South African Revenue Service, tariff query portal) | §6 |
| China export-side duties to be confirmed against the live GACC Online Customs query result page returned for the actual HS subheading at time of export. | https://online.customs.gov.cn/ (General Administration of Customs of the People's Republic of China — Online Customs / GACC) | §6 |
| Bend-radius multipliers (e.g., 4×OD fixed, 5×OD dynamic) are OEM-published on the cable manufacturer's product family page and printed on the datasheet shipped on the reel. | Lapp Ölflex Solar XLR-R product family page & Prysmian cables for solar applications product family page | §2, Step 1 |
| All cost slots are indicative and require an RFQ for firm pricing. RFQ form lives at the TradVolt site path /rfq/. | https://tradvolt.com/rfq/ (TradVolt RFQ form, site path /rfq/) | §5, §8 |
| Printable §3 document checklist is available as a downloadable PDF asset. | https://tradvolt.com/assets/cnza-r14-bend-radius-checklist.pdf (TradVolt asset path /assets/cnza-r14-bend-radius-checklist.pdf) | §3, §8 |