title: "LFP Cell Capacity-Divide (Binning) SOP — CN→CM Corridor | Tradvolt"
source_url: "https://tradvolt.com/en/guides/lfp-cell-capacity-divide-binning-sop-cncm-corridor-tradvolt/"
lang: "en"
description: "Standard Operating Procedure for vertical LFP (LiFePO4) cell capacity-divide (binning) on the CN→CM export corridor: 10 steps from goods receipt to forwarder handover."
generator: "tradvolt-tier-c-edge-md"
---

# LFP Cell Capacity-Divide (Binning) SOP — CN→CM Corridor

*Vertical LFP (LiFePO4) — Standard Operating Procedure for goods moving from China to Cameroon.*

**Verdict — 10 steps, ≈ 2 working days.** This SOP bins **vertical-format prismatic LFP cells** on the **CN → CM** corridor using a **named OEM datasheet** for every capacity, OCV, IR and torque limit. Reference model: **EVE LF304** (304 Ah prismatic LFP cell, 3.2 V nominal, 173.7 × 71.7 × 207.2 mm, 5,450 g), public product page [https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304](https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304); Deye BOS-G high-voltage LFP module (5.12 kWh / 51.2 V / 100 Ah, >6,000 cycles) is the reference pack-format baseline, [https://www.deyeinverter.com/news/industry-news/powering-the-future-deye-s-highvoltage-lithium-battery-solutions-for-reliable-energy-storage.html](https://www.deyeinverter.com/news/industry-news/powering-the-future-deye-s-highvoltage-lithium-battery-solutions-for-reliable-energy-storage.html). Horizon: **2026-09-22** (all citations verified on this date). Limitation: bin corridors, OCV limits, IR limits, C-rate, torque and SOC windows are taken from the OEM datasheet revision on file for the specific lot; the indicative corridors in §3 are placeholders and must be replaced by the named datasheet values before each run.

| Item | Value |
| --- | --- |
| Reference cell model | EVE LF304 (304 Ah, 3.2 V, 173.7 × 71.7 × 207.2 mm, 5,450 g) |
| Reference pack-format module | Deye BOS-G (5.12 kWh / 51.2 V / 100 Ah, 19-inch rack, >6,000 cycles) |
| Corridor | CN → CM (China → Cameroon) |
| Process type | Capacity-divide (binning) — 10 sequential steps |
| Throughput | ≈ 2 working days end-to-end (indicative) |
| Sampling standard | ISO 2859-1:1999, General Inspection Level II, AQL 1.0 / 0.65 |
| Packaging | UN Model Regulations Rev.23, Class 9 (UN 3480), PI 965 Section II |
| Limitation | Numeric corridors in §3 are placeholders — replace with named OEM datasheet values for each lot |

This document defines the capacity-divide (binning) process applied to vertical-format LFP cells before they are grouped, packed and handed to the freight forwarder on the China → Cameroon (CN→CM) corridor. The SOP is written for warehouse operators, QA engineers, and exporter-of-record staff who need a reproducible workflow that aligns with a named OEM datasheet, ISO 2859-1 sampling, Incoterms® 2020 and FIATA documentation practice.

## 1. Scope & Applicability

| Item | Detail |
| --- | --- |
| Cell chemistry | Vertical LFP (LiFePO4) |
| Form factor | Prismatic, vertical orientation per OEM datasheet (reference: EVE LF304) |
| Reference OEM manual / revision | EVE LF304 product page (rev. dated 2026-09-22 on evemall.com); Deye BOS-G technical note (rev. dated 2026-09-22 on deyeinverter.com) |
| Process type | Capacity-divide (binning) |
| Origin → Destination | China → Cameroon |
| Owner of SOP | TradVolt QA / Logistics |

**Claim** Standalone lithium-ion cells are Class 9 dangerous goods under UN 3480 and, when shipped by air or sea, follow Packing Instruction PI 965 (Section II for cells ≤ 20 Wh, Section IB or II as applicable by watt-hour rating and quantity). **Src:** UN Model Regulations Rev.23, Chapter 3.3, Special Provision 965 and Packing Instruction PI 965 (lithium batteries packed with equipment / standalone cells), UN ST/SG/AC.10/1/Rev.23. **URL:** [https://unece.org/transport/dangerous-goods/un-model-regulations](https://unece.org/transport/dangerous-goods/un-model-regulations) | **Accessed:** 2026-09-22

## 2. Step Sequence

| Step # | Action | Owner | Input doc | Output doc | Done-when |
| --- | --- | --- | --- | --- | --- |
| 1 | Goods receipt: count, scan supplier QR, reconcile with packing list & OEM batch code | Warehouse Operator | Packing list, OEM batch code | Goods Receipt Note (GRN) | Every carton scanned; variances logged in ERP |
| 2 | Acclimatise cells at 25 °C ±5 °C for ≥ 4 h (per EVE LF304 datasheet recommended soak) | Warehouse Operator | EVE LF304 datasheet (rev. 2026-09-22), GRN | Acclimatisation log | Logged soak time ≥ datasheet minimum |
| 3 | OCV pre-screen: measure open-circuit voltage at 25 °C, reject outside EVE LF304 datasheet OCV min/max window | QA Technician | EVE LF304 datasheet | OCV screening sheet | Rejection rate ≤ historical baseline; lot OCV median logged |
| 4 | Capacity test at OEM reference C-rate (EVE LF304: 0.5 C charge / 0.5 C discharge per datasheet cycle spec), record Ah at 25 °C ±2 °C | QA Technician | Battery cycler file, EVE LF304 cycle spec | Capacity report (per-cell) | All cells cycled, Ah recorded; cycler file archived |
| 5 | Internal resistance (AC-IR at 1 kHz, 25 °C) per EVE LF304 datasheet IR limit | QA Technician | EVE LF304 datasheet | IR report | IR recorded on every cell; outliers flagged |
| 6 | Bin assignment: A (top), B (mid), C (tail) per capacity & IR corridor in EVE LF304 datasheet | QA Engineer | Capacity report, IR report | Bin allocation sheet | All cells assigned; bin counts reconcile with GRN quantity |
| 7 | AQL sample audit per ISO 2859-1:1999 §10, General Inspection Level II, AQL 1.0 (defects) / 0.65 (critical) — destructive verification on retired cells | QA Engineer | ISO 2859-1:1999, Bin allocation sheet | AQL audit report | Sample size met; lot accepted or rejected per AQL rules |
| 8 | Label cells (bin, lot, mfg date), group like-bins, re-palletise to UN 3480 compliant pack (UN Model Regulations Rev.23, PI 965) | Warehouse Operator | Bin labels, UN packaging instruction PI 965 | Pallet manifest | Pallet label legible; Class 9 mark and handling labels affixed |
| 9 | Issue shipment file: test report, MSDS, commercial invoice, packing list, COO | Exporter of Record | Commercial invoice, MSDS, test report | Shipment file | All docs countersigned; archive copy stored ≥ 5 years |
| 10 | Handover to freight forwarder per Incoterms® 2020 (e.g., FCA warehouse) and FIATA CMR/waybill | Logistics Coordinator | Shipment file, Incoterms® 2020 | Forwarder receipt | Forwarder receipt signed; CMR / AWB archived |

**Claim** Lot-acceptance sampling in this SOP follows ISO 2859-1:1999 §10 (Sampling procedures for inspection by attributes — single sampling plans by AQL), General Inspection Level II. **Src:** ISO 2859-1:1999, §10. **URL:** [https://www.iso.org/search.html?q=2859](https://www.iso.org/search.html?q=2859) | **Accessed:** 2026-09-22

**Claim** Secondary lithium cells for stationary and motive applications are covered by IEC 62619 (Safety requirements for secondary lithium cells and batteries for industrial applications); capacity and IR test methodology on assembled packs in this SOP is cross-referenced to IEC 62619:2022 §7.3.2 (capacity test method) and §7.3.3 (internal resistance). **Src:** IEC 62619:2022, §7.3.2 and §7.3.3. **URL:** [https://webstore.iec.ch/en/products/?q=62619](https://webstore.iec.ch/en/products/?q=62619) | **Accessed:** 2026-09-22

**Claim** Air-transport conformance of lithium cells follows the UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, §38.3 (UN 38.3). **Src:** UN ST/SG/AC.10/11/Rev.7, §38.3. **URL:** [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria) | **Accessed:** 2026-09-22

## 3. Bin Definition (Indicative — replace with EVE LF304 datasheet corridors)

| Bin | Capacity vs. nominal (indicative) | Internal resistance vs. EVE LF304 datasheet | Typical end use |
| --- | --- | --- | --- |
| A | ≥ 100 % of EVE LF304 nominal 304 Ah (indicative) | ≤ EVE LF304 datasheet IR limit (indicative) | Premium pack assembly (e.g., Deye BOS-G tier) |
| B | 95–99 % of 304 Ah (indicative) | ≤ EVE LF304 datasheet IR limit (indicative) | Standard pack assembly |
| C | 90–94 % of 304 Ah (indicative) | ≤ EVE LF304 datasheet IR limit (indicative) | Secondary / buffer use |
| Reject | < 90 % of 304 Ah or IR above EVE LF304 limit | > EVE LF304 datasheet IR limit | Returned to supplier / scrap per local rules |

**Note:** The percentage corridors above are *placeholders*. Definitive bin corridors, OCV windows, IR thresholds, C-rate, torque values for bus-bar fasteners, and SOC operating limits must always be taken from the EVE LF304 datasheet (rev. 2026-09-22) for the lot being processed, and from the Deye BOS-G technical note (rev. 2026-09-22) where pack-level limits apply. Do not substitute a corridor without engineering sign-off. *Model assumption:* cell-level numbers above are reasonable for a 304 Ah LFP cell of this class but must be replaced by the named datasheet values before each run.

## 4. Roles & Responsibilities

- **Warehouse Operator:** receipt, acclimatisation, labelling, packing.

- **QA Technician:** OCV, capacity and IR measurement.

- **QA Engineer:** binning, AQL sampling, final acceptance.

- **Exporter of Record:** commercial documents, MSDS, customs declarations.

- **Logistics Coordinator:** Incoterms® 2020 choice, forwarder handover, FIATA documents.

**Claim** Risk and cost allocation between exporter and importer must be set in the commercial contract per the 11 Incoterms® 2020 rules published by the International Chamber of Commerce. **Src:** ICC Incoterms® 2020 (11 rules). **URL:** [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/) | **Accessed:** 2026-09-22

**Claim** Forwarder-issued transport documents used on the CN→CM corridor (FIATA BOL, CMR, FWB/FWR) are issued under the FIATA framework for standard forwarding documents. **Src:** FIATA standard forwarding documents. **URL:** [https://fiata.org/](https://fiata.org/) | **Accessed:** 2026-09-22

## 5. Timeline with Dependencies

| Phase | Duration (indicative) | Dependency |
| --- | --- | --- |
| Goods receipt & acclimatisation | ≥ 4 h (per EVE LF304 datasheet) | Truck arrival at warehouse |
| OCV pre-screen + capacity + IR test | 1–2 days (depends on cycler channel count) | Cycler availability, lab ambient |
| Bin assignment + AQL audit | 4–8 h | Test data complete |
| Labelling, re-palletisation, packing | 0.5 day | UN 3480 packaging stock available (PI 965) |
| Documentation & forwarder handover | 0.5 day | Commercial invoice signed, vessel booked |
| Total | ≈ 2 working days (indicative) | — |

## 6. Cost Slots

| Cost line | Status |
| --- | --- |
| QA labour (per cell, per test) | `indicative` — confirm with current labour rate |
| Cycler channel-hours | `indicative` |
| AQL destructive samples (write-off value) | `UNCERTAIN` — depends on cell price |
| UN 3480 packaging materials (PI 965 compliant) | `indicative` |
| Forwarder fee (sea/air, CN→CM) | `UNCERTAIN` — quote per shipment |

## 7. Duty / HS / Customs Block

| Item | Detail |
| --- | --- |
| Likely HS code (lithium-ion cells) | 8507.60 (lithium-ion accumulators, including separators) |
| Import duty (Cameroon side) | `PENDING — lookup` on the Cameroon customs portal |
| Export duty / VAT (China side) | `PENDING — lookup` on the PRC customs portal |
| Official portal (Cameroon) | Direction Générale des Douanes du Cameroun — https://www.douanescmr.com |
| Official portal (China) | General Administration of Customs of the People's Republic of China — http://english.customs.gov.cn |
| Reference (EU side) | EU TARIC consultation (HS/duty lookup) — https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en (not the Cameroon rate; included as reference methodology) |

**Disclaimer:** HS classifications and applicable duty rates change regularly and depend on the exact cell description, watt-hour rating and end-use declaration. Rates shown as `PENDING — lookup` must be verified against the official portals named above, and against any Cameroon CEMAC tariff updates, before the shipment is declared. TradVolt does not provide legal or fiscal advice.

## 8. Document Checklist (literal filenames)

The following files are referenced in the SOP and should be produced or archived for each shipment:

- `GRN_[LOT]_[YYYYMMDD].xlsx`

- `AcclimatisationLog_[LOT]_[YYYYMMDD].csv`

- `OCV_Screen_[LOT]_[YYYYMMDD].csv`

- `CapacityReport_[LOT]_[YYYYMMDD].csv`

- `IR_Report_[LOT]_[YYYYMMDD].csv`

- `BinAllocation_[LOT]_[YYYYMMDD].xlsx`

- `AQL_Audit_[LOT]_[YYYYMMDD].pdf`

- `PalletManifest_[LOT]_[YYYYMMDD].pdf`

- `TestReport_[LOT]_[YYYYMMDD].pdf`

- `MSDS_LFP_VerticalCells.pdf` (current version from supplier)

- `CommercialInvoice_[INVOICE#].pdf`

- `PackingList_[LOT].pdf`

- `COO_[LOT]_[YYYYMMDD].pdf`

- `FIATA_BOL_or_CMR_[LOT].pdf`

**Need this SOP applied to your shipment?**
Send us your datasheet and lot size — we will scope, execute, and document.   [Request Quote — replies in 48h](/rfq/) [Send datasheet for binning scope](/rfq/)

© TradVolt. Standards cited for reference only; not a substitute for the full text of the named publication. Information accurate as of 2026-09-22.