# Maintenance & Process Guide — BMS CAN-Bus Termination Resistor (R14), CN→Sea Corridor

A step-by-step maintenance procedure for the 120 Ω R14 termination resistor on Battery Management System CAN strings shipped via the China-to-sea export corridor. Designed for service technicians and procurement teams handling inverter, BESS, and EV-charger cabinets.

**Target equipment family:** Sungrow ST5015/1253UH-CB96 battery cabinet (BMS: Sungrow SCADA-BMS-200, see [sungrowpower.com/en](https://www.sungrowpower.com/en)) — used as the worked-example BMS product family throughout this guide. For CATL EnerC, BYD Premium HVS, Sungrow ST5015/1253UH-CB96, Growatt Spot, or Huawei LUNA2000 deployments, confirm R14 location and torque values against that OEM's service manual before applying this procedure.

[Request Quote (RFQ) — R14 Service Pack](https://tradvolt.com/rfq/)   **Verdict (read first).** This page is a **maintenance/process SOP**, not a buying guide. The auditable answer is a **10-step procedure (Table §2)** for one specific product line — the **Sungrow ST5015/1253UH-CB96 battery cabinet**, on the **CN→sea export corridor**, covering the **120 Ω R14 CAN-bus termination resistor**. Evidence date: **2026-09-22**. Limitation: the worked-example assumes the Sungrow SCADA-BMS-200 cabinet; for any other BMS OEM, R14 position, reflow profile, and fastener torque must be re-confirmed from the OEM service manual before applying the procedure.

| Item | Value |
| --- | --- |
| Equipment family | Sungrow ST5015/1253UH-CB96 battery cabinet (worked example); SCADA-BMS-200 BMS |
| Component | R14 — 120 Ω ±1 % CAN-bus termination resistor |
| Location on CAN string | Across CAN-H and CAN-L at each physical end of the trunk (per ISO 11898-2:2016, §6.2) |
| Corridor | CN → sea export (China origin ports → overseas destination) |
| Horizon | One service event, PT45M total per HowTo schema |
| Evidence date | 2026-09-22 |
| Limitation | R14 position, torque (0.4 N·m), and reflow profile (peak 245 °C, TAL 60–90 s) are valid only for the SCADA-BMS-200 cabinet; verify against OEM service note before applying to any other BMS |

## 1. Why R14 matters on the CN→sea corridor

Every CAN-bus segment requires exactly two 120 Ω termination resistors — one at each physical end of the trunk — to suppress signal reflection on the differential pair. The resistor labelled **R14** in most BMS reference designs sits on the last node of the string, frequently a slave BMS or a gateway PCB inside the cabinet. When that node suffers a vibration-induced cold joint, salt-air corrosion on the terminal housing, or condensation creep during the ocean leg, the bus presents an open circuit at one end and the entire string starts logging *CAN bus off* errors.

The CN→sea route adds three stressors that a domestic shipment does not see:

- **Humidity swing.** Container dew point changes during the sea leg can drive moisture into unsealed connector housings.

- **Vibration.** Lash-down on RORO decks and stacked containers couples low-frequency vibration into PCB-mounted resistors.

- **Salt-air exposure at origin or destination port.** Coastal terminals such as Shanghai, Ningbo, Shenzhen-Yantian, and Singapore add chloride to the corrosion load.

This guide gives the maintenance team a single, auditable procedure that can be run at a service depot in the destination market without re-flashing firmware.

Source: ISO 11898-2:2016, §6.2 (High-speed medium access unit — termination); see [iso.org search for ISO 11898](https://www.iso.org/search.html?q=11898) for the standard text and edition. The ISO catalogue deep-URLs are bot-walled — cite the designation + year in text and use the ISO search page.

## 2. Process step-sequence (Sungrow SCADA-BMS-200 worked example)

One owner per step. Inputs and outputs are written so that every completed step is auditable from the file system.

**Model assumption:** the worked-example targets the Sungrow ST5015/1253UH-CB96 battery cabinet with Sungrow SCADA-BMS-200 BMS. R14 reflow profile (peak 245 °C, TAL 60–90 s) and fastener torque (0.4 N·m, M2.5) come from the Sungrow BMS Service Note *SG-SN-BMS200-Rev.D (2024-08)* — pending OEM service-note verification: PENDING — verify before applying. For any other cabinet family, these values MUST be re-read from the OEM service manual before the procedure is run.

| Step # | Action | Owner | Input doc | Output doc | Done-when |
| --- | --- | --- | --- | --- | --- |
| 1 | Confirm corridor documentation set is complete | Service coordinator | CN-SEA-SHIP-DOSSIER.pdf | DOC-CHECKLIST-v1.xlsx | All four files present and version-matched to the unit serial |
| 2 | Open the BMS rack and isolate HV / DC bus | HV technician | OEM-LOTO-RESISDA.pdf | LOTO-LOCK-LOG.pdf | Lockout tag physically applied; cool-down timer started (5 min per Sungrow SG-SN-BMS200-Rev.D §4.2) |
| 3 | Apply ESD discipline at the PCB | PCB technician | ESD-PROCEDURE.pdf | ESD-WRIST-LOG.pdf | Wrist-strap test reading logged in range (ANSI/ESD S20.20) |
| 4 | Locate R14 on the wiring diagram | PCB technician | BMS-WIRING-DIAGRAM.pdf | NODE-LOC-R14.xlsx | Node ID, board rev, and resistor footprint recorded |
| 5 | Measure R14 in situ (bus unpowered) | PCB technician | MULTIMETER-CAL-CERT.pdf | R14-MEAS-SHEET.pdf | Reading entered with unit-under-test serial, date, and meter ID |
| 6 | Power the bus, capture CAN waveform | Diagnostics engineer | CAN-ANALYSER-CAL.pdf | R14-WAVEFORM.png | Screenshot saved with node ID and analyser ID in filename |
| 7 | Sign off the inspection on the checklist | Service coordinator | R14-MEAS-SHEET.pdf | R14-CHECKLIST.pdf | Checklist signed; go / no-go decision recorded |
| 8 | Replace R14 with OEM-specified 120 Ω ±1 % part | PCB technician | R14-PART-CROSSREF.pdf | R14-REPLACE-LOG.pdf | New resistor fitted; reflow profile logged (peak 245 °C, TAL 60–90 s); dielectric grease applied |
| 9 | Re-measure and re-verify CAN traffic | Diagnostics engineer | R14-REPLACE-LOG.pdf | R14-VERIFY-SHEET.pdf | Resistance within tolerance; bus error counters at nominal |
| 10 | Restore conformal coating and torque fasteners | PCB technician | BMS-OEM-TORQUE-TABLE.pdf | TORQUE-LOG.pdf | Fasteners torqued to 0.4 N·m (M2.5) per OEM service note; conformal coat cured |
| 11 | Re-pack to corridor standard and close work order | Logistics technician | CN-SEA-PACK-STANDARD.pdf | WO-CLOSE.pdf | Work order signed; unit released to next depot or to client |

## 3. Document checklist (literal filenames used at the depot)

The files below are depot-side artefacts the service team generates and signs. Where the page references an OEM or external document, see the Claim-row footer (§9) for the source URL and document designation.

- CN-SEA-SHIP-DOSSIER.pdf

- DOC-CHECKLIST-v1.xlsx

- OEM-LOTO-RESISDA.pdf

- LOTO-LOCK-LOG.pdf

- ESD-PROCEDURE.pdf

- ESD-WRIST-LOG.pdf

- BMS-WIRING-DIAGRAM.pdf

- NODE-LOC-R14.xlsx

- MULTIMETER-CAL-CERT.pdf

- R14-MEAS-SHEET.pdf

- CAN-ANALYSER-CAL.pdf

- R14-WAVEFORM.png

- R14-CHECKLIST.pdf

- R14-PART-CROSSREF.pdf

- R14-REPLACE-LOG.pdf

- R14-VERIFY-SHEET.pdf

- BMS-OEM-TORQUE-TABLE.pdf

- TORQUE-LOG.pdf

- CN-SEA-PACK-STANDARD.pdf

- WO-CLOSE.pdf

## 4. Timeline

| Phase | Window | Owner | Notes |
| --- | --- | --- | --- |
| Pre-arrival paperwork | T-5 to T-1 days | Service coordinator | Corridor dossier reconciliation before the unit clears customs |
| Intake inspection | T0 (day of arrival at depot) | Service coordinator | Open the cabinet, photograph corrosion or impact marks |
| R14 measurement | T0 + 1 h | PCB technician | Use a meter with known traceability (ISO/IEC 17025 accredited cal cert) |
| R14 replacement (if required) | T0 + 2 to T0 + 3 h | PCB technician | Reflow profile must match the BMS OEM note (peak 245 °C, TAL 60–90 s — Sungrow worked example) |
| Verification & re-pack | T0 + 4 h | Diagnostics engineer + logistics technician | Sign-off, then re-pack using the corridor cushion set |
| Release to client or next depot | T0 + 3 h | Logistics technician | Work order closed with the technician's signature |

## 5. Indicative cost table

All values labelled INDICATIVE or PENDING. No hard prices are stated. Verify against the OEM price list and your freight forwarder before quoting the client.

| Item | Range | Status |
| --- | --- | --- |
| OEM 120 Ω ±1 % SMD resistor (per piece) | UNCERTAIN — depends on BMS OEM and on cross-ref part number | PENDING |
| Dielectric grease (per tube) | INDICATIVE — small consumable line item | INDICATIVE |
| Replacement terminal / housing | INDICATIVE — line item varies by connector family | INDICATIVE |
| Technician labour, per hour | UNCERTAIN — depends on depot country and certification level | PENDING |
| Reflow profile setup (one-off, per BMS OEM) | UNCERTAIN — set up once and reuse across the fleet | PENDING |
| Re-pack cushion set, corridor standard | INDICATIVE — small materials line item | INDICATIVE |

## 6. HS / duty block

HS classification must be confirmed by a licensed customs broker in the destination market. The lines below are a starting point for that lookup, not a binding ruling.

| Field | Value |
| --- | --- |
| HS code (indicative) | 8533.21 — Fixed carbon resistors, composition or film type; fixed resistors with two or more connecting pieces (resistor-only line items). Verify against the destination national tariff. |
| EU TARIC lookup | ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp |
| UK Global Tariff lookup | trade-tariff.service.gov.uk |
| US HTSUS lookup | hts.usitc.gov |
| Duty rate | PENDING — lookup at the destination customs portal |
| VAT / GST | PENDING — destination market dependent |
| Disclaimer | HS classification and duty rates are for guidance only. Final classification must be confirmed by a licensed customs broker in the destination market. |

## 7. FAQ

### What value should R14 read on the multimeter?

A healthy R14 reads approximately 120 Ω with the bus unpowered and no other node active on that segment. Tolerance depends on the BMS OEM part — typically ±1 % for SMD metal-film parts. A reading near 0 Ω indicates a short; an open-loop reading indicates a cracked joint or lifted pad.

Source: ISO 11898-2:2016, §6.2 (CAN bus termination), catalogued at [iso.org/search.html?q=11898](https://www.iso.org/search.html?q=11898).

### Why exactly 120 Ω, and not something else?

CAN transceivers are designed to drive a 60 Ω differential load — that is two 120 Ω terminators in parallel at each end of the bus. Using a different value degrades the recessive-state bias and causes reflections. The 120 Ω value is fixed by the ISO 11898-2:2016 CAN standard (High-speed medium access unit, §6.2).

Source: ISO 11898-2:2016, §6.2, catalogued at [iso.org/search.html?q=11898](https://www.iso.org/search.html?q=11898).

### Do I need to re-flash the BMS after replacing R14?

No. R14 is a passive resistor; it carries no firmware. The BMS does not need re-flashing. You do need to verify that the node addressing and the bus error counters return to nominal, which is what Step 9 of the sequence covers.

### Can the unit be powered on while I measure R14?

No. Measure with the bus unpowered. A powered bus will back-drive the multimeter input and give an unreliable reading. Power only when capturing the CAN waveform in Step 6.

### How often should R14 be inspected on a CN→sea-deployed unit?

Most OEMs recommend a CAN-bus health check at every scheduled service interval — typically annually for stationary BESS, and at every major depot visit for EV-charger cabinets. After any incident that involves salt-air exposure, vibration, or water ingress, run the procedure out of cycle.

Source: BMS OEM service schedule (Sungrow ST5015/1253UH-CB96: annual; pending verification for CATL / Huawei, etc.) — see [sungrowpower.com/en](https://www.sungrowpower.com/en).

## 8. Downloads & procurement

Use the button below to request a quote for the R14 service pack. The full maintenance checklist PDF is delivered as part of the RFQ reply.

[Request Quote (RFQ) — R14 Service Pack](https://tradvolt.com/rfq/)