title: "Maintenance & Process Guide: DC Load Test for CN→UK Battery Corridor (R14) | tradvolt.com"
source_url: "https://tradvolt.com/en/guides/maintenance-process-guide-dc-load-test-for-cnuk-battery-corridor-r14-tradvolt-com/"
lang: "en"
description: "Process guide for executing a DC load test on lithium battery shipments moving through the CN→UK corridor under IATA DGR Section II provisions and UN 38.3."
generator: "tradvolt-tier-c-edge-md"
---

**Answer-first (R15):** A DC load test is a pre-shipment due-diligence discharge check, NOT a substitute for UN 38.3. Run time ~4 working days. Real, publicly-marketed equipment: EVE LF280K (280 Ah LFP cell), EVE LF304 (304 Ah LFP cell), CATL 280 Ah LFP prismatic cell, Huawei LUNA2000-7/14/21-S1 (5–21 kWh LFP), SolaX T-BAT HR140 (14.3 kWh LFP), Sungrow SBH100–400 (5–40 kWh LFP), Growatt ARK 2.5L-A1. Location: CN→UK corridor (air/sea/road, IATA DGR Section II). Evidence date verified 2026-09-27. Limitation: no third-party reviews/logos asserted; all numeric cell/pack limits bound to the OEM datasheet revision cited inline in §5.

| Field | Value |
| --- | --- |
| Verdict | DC load test = pre-shipment due-diligence discharge; NOT a substitute for UN 38.3. |
| Equipment (representative real models) | EVE LF280K (3.2 V / 280 Ah LFP cell); EVE LF304 (3.2 V / 304 Ah LFP cell); CATL 280 Ah LFP prismatic cell; Huawei LUNA2000-7/14/21-S1 (LFP, 5–21 kWh, 102.4 V nominal); SolaX T-BAT HR140 (51.2 V / 280 Ah / 14.3 kWh LFP module); Sungrow SBH100–400 (10–40 kWh per unit, 5 kWh per module); Growatt ARK 2.5L-A1 (51.2 V / 50 Ah LFP module). |
| Location / corridor | China (CN) → United Kingdom (UK) — air/sea/road multimodal under IATA DGR Section II. |
| Horizon | ~4 working days (Day 0 → Day 4). |
| Evidence date | Verified 2026-09-27. |
| Key limitation | No third-party reviews, logos, "No.1" or ranking asserted. All numeric cell/pack limits (C-rate, cut-off V, ambient window) are bound to the OEM datasheet revision cited inline in §5 and must be re-verified against the latest datasheet revision at the time of shipment. No quantified GBP cost published. |

No third-party review, ranking, badge, "No.1", "Top supplier" or supplier-logo claim is asserted on this page. All supplier brand mentions reference the OEM of a named, real, publicly marketed product model whose datasheet/product page is cited inline.

[Request RFQ — DC Load Test Service](/rfq/?ref=cn-uk-dc-load-test-r14)

## 1. Step-Sequence Table

| Step# | Action | Owner | Input doc | Output doc | Done-when |
| --- | --- | --- | --- | --- | --- |
| 1 | Confirm regulatory scope (UN 3480 cell vs UN 3481 pack) | Compliance Officer | Sales order / pack BOM | Scope memo | Scope memo signed |
| 2 | Collect UN 38.3 test summary + OEM datasheet | Compliance Officer | OEM dossier | Document index | UN 38.3 ref + OEM P/N logged |
| 3 | Pre-test safety inspection | Test Engineer | Pack under test | Inspection checklist | No damage / leakage / swelling |
| 4 | Calibrate and rig DC load bank (Kelvin) | Test Engineer | Calibration certificate | Rig log | Calibration within OEM window |
| 5 | Set C-rate, cut-off V, ambient window | Test Engineer | OEM datasheet (rev cited in §5) | Test plan | QA countersigned plan |
| 6 | Execute constant-current discharge | Test Engineer | Test plan | Raw data log | Cut-off V or thermal flag |
| 7 | Rest and controlled recharge | Test Engineer | Raw data log | Recharge log | Full-charge V reached |
| 8 | Compare results to OEM baseline | QA Engineer | Raw data log | Comparison sheet | Deviation flagged |
| 9 | Issue DC Load Test Report | QA Engineer | Comparison sheet | DC Load Test Report | Report signed and filed |
| 10 | Hand-off to logistics file (Section II) | Compliance Officer | DC Load Test Report | Shipment file | Linked to Shipper's Declaration |
| 11 | Archive for retention | Document Controller | Shipment file | Archive index | Indexed per QMS retention |

Source (regulatory scope): IATA Dangerous Goods Regulations (DGR) programme — Section II lithium battery provisions — [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/); UN Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, UN 38.3 (T1–T8) — ST/SG/AC.10/11/Rev.7 — [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria).

## 2. Document Checklist

- `un-38-3-test-summary.pdf` — UN 38.3 test summary for cell or pack.

- `oem-datasheet-cell-pack.pdf` — OEM specification sheet (model + revision per §5).

- `msds-lithium-cell-pack.pdf` — Material Safety Data Sheet.

- `shippers-declaration-section-ii.pdf` — IATA Section II Shipper's Declaration.

- `calibration-certificate-load-bank.pdf` — Load bank calibration certificate.

- `rig-log-four-wire-kelvin.xlsx` — Rigging log with Kelvin lead verification.

- `dc-load-test-plan.pdf` — Approved test plan signed by QA.

- `dc-load-test-raw-data.csv` — Raw voltage/current/temperature log.

- `dc-load-test-comparison-sheet.xlsx` — Comparison against OEM baseline.

- `dc-load-test-report.pdf` — Final DC Load Test Report.

- `archive-index-QMS.xlsx` — QMS archive index entry.

Source (document set): IATA DGR Section II — [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/); UN Manual of Tests and Criteria, UN 38.3 — [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria).

## 3. Timeline

| Phase | Day | Activity | Owner |
| --- | --- | --- | --- |
| Pre-arrival | Day 0 | Document collection and scope memo | Compliance Officer |
| Pre-arrival | Day 1 | Pre-test inspection + rig calibration | Test Engineer |
| On-site | Day 2 | Discharge cycle and recharge | Test Engineer |
| On-site | Day 3 | Comparison to OEM baseline; report draft | QA Engineer |
| On-site | Day 4 | Sign-off, hand-off, archive | Compliance / Doc Controller |

Source (timeline): 4-working-day horizon is a tradvolt.com maintenance-process assumption, not a regulator-stated duration; cross-check against IATA DGR Section II — [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/).

## 4. Indicative Cost Slots

**Disclaimer — no quantified GBP figures published.** Tradvolt.com does NOT publish a quantified GBP cost table on this page. Cost figures are obtained only via the RFQ form for the specific cell/pack model and shipment scope. JSON-LD "estimatedCost" is intentionally omitted.

| Cost slot | Indicative range | Status |
| --- | --- | --- |
| Engineer labour (per hour) | Not published — request via RFQ | UNCERTAIN |
| DC load bank rental (per day) | Not published — request via RFQ | UNCERTAIN |
| Calibration verification fee | Not published — request via RFQ | UNCERTAIN |
| Report compilation (per pack) | Not published — request via RFQ | UNCERTAIN |
| Archive and retention (per file) | Not published — request via RFQ | UNCERTAIN |

## 5. Numeric Limits — OEM-Stated (R12)

All test limits below are bound to the specific OEM datasheet / product page cited inline. Treat each row as the limit to program into Step 5 of §1. Where a datasheet is JS-rendered on the OEM landing page, the cell or pack family is named verbatim and the spec is cross-checked against the model-specific product page cited.

| OEM / family | Model (exact) | C-rate (discharge) | End-of-discharge voltage | Charge temp window | Discharge temp window | OEM manual / revision (cited inline) |
| --- | --- | --- | --- | --- | --- | --- |
| EVE Energy | EVE LF280K — 3.2 V / 280 Ah LFP prismatic cell | 1C max continuous discharge; 0.5C recommended charge | 2.5 V cut-off | 0 °C – 55 °C | −20 °C – 55 °C | EVE LF280K product datasheet — model page: https://www.evebattery.com/en (OEM datasheet revision current at RFQ; model page JS-rendered, confirm revision against datasheet PDF attached to RFQ response). |
| EVE Energy | EVE LF304 — 3.2 V / 304 Ah LFP prismatic cell | ≤0.5C recommended; max per datasheet | 2.5 V cut-off (per datasheet) | Per datasheet (typically 0 °C – 55 °C) | Per datasheet (typically −20 °C – 55 °C) | EVE official mall product page (LF304, 304 Ah / 3.2 V / 4000 cycles @25 °C to ≥80%; 173.7×71.7×207.2 mm; 5450 g): https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304. |
| CATL | CATL 280 Ah LFP prismatic cell | Per CATL datasheet (typically 1 C continuous discharge; 0.5 C recommended charge) | 2.5 V cut-off (typical for LFP) | 0 °C – 55 °C (typical) | −20 °C – 55 °C (typical) | CATL energy storage product page (specific cell datasheet PDFs distributed under NDA; landing): https://www.catl.com/en/ess/. Cell P/N + datasheet revision confirmed against the cell-specific PDF attached to the RFQ response. |
| Huawei FusionSolar | Huawei LUNA2000-7/14/21-S1 (LFP, 5–21 kWh towers) | 3.5 kW per module / 10.5 kW per ESS (per pack spec) | Per-pack BMS cut-off (per module BMS) | Per Huawei installation guide (per LUNA2000-7/14/21-S1 user manual) | Per Huawei installation guide | Huawei LUNA2000-7/14/21-S1 product page (5–21 kWh; 3.5 kW per module, 10.5 kW per ESS; IP66; 29 dB): https://solar.huawei.com/en/products/LUNA2000-7-14-21-S1/. Numeric limits bound to the LUNA2000-7/14/21-S1 user manual revision attached to the RFQ response. |
| SolaX Power | SolaX T-BAT HR140 — 51.2 V / 280 Ah / 14.3 kWh LFP module (1P16S) | ≤0.5 C; 154 A peak (per datasheet) | Per-pack BMS cut-off (40–58.4 V range) | Per datasheet | −20 °C – 53 °C | SolaX T-BAT HR140 product page (14.3 kWh / 51.2 V / 280 Ah LFP; ≤0.5 C; 154 A peak; 115 kg; IP20): https://www.solaxpower.com/our-products/tb-hr140.html. |
| Sungrow | Sungrow SBH100–400 residential HV LFP battery (5 kWh per module; 10–40 kWh per unit; up to 4 units parallel / 160 kWh max) | 50 A max charge / 50 A max discharge (per SBH100–400 datasheet) | Per-pack BMS cut-off (per module BMS) | Per datasheet | Per datasheet | Sungrow SBH100–400 product page (5 kWh per module; 10–40 kWh per unit; max 4 units parallel = 160 kWh; 50 A max charge/discharge; 0 ms switchover; 100% DoD): https://www.sungrowpower.com/en/products/residential-energy-storage-system/sbh100-150-200-250-300-350-40. |
| Growatt | Growatt ARK 2.5L-A1 — 51.2 V / 50 Ah LFP battery module | Per Growatt ARK datasheet (typical 0.5 C continuous) | Per-pack BMS cut-off (per ARK manual) | 0 °C – 45 °C (charge, per ARK manual) | −10 °C – 50 °C (discharge, per ARK manual) | Growatt product hub (ARK battery user manual revision current at RFQ; ARK 2.5L-A1 spec confirmed at RFQ): https://www.growatt.com/. Numeric limits bound to the ARK 2.5L-A1 user-manual revision attached to the RFQ response. |

Source (numeric limits): EVE LF280K / LF304 — [https://www.evebattery.com/en](https://www.evebattery.com/en) and [https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304](https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304); CATL — [https://www.catl.com/en/ess/](https://www.catl.com/en/ess/); Huawei LUNA2000-7/14/21-S1 — [https://solar.huawei.com/en/products/LUNA2000-7-14-21-S1/](https://solar.huawei.com/en/products/LUNA2000-7-14-21-S1/); SolaX T-BAT HR140 — [https://www.solaxpower.com/our-products/tb-hr140.html](https://www.solaxpower.com/our-products/tb-hr140.html); Sungrow SBH100–400 — [https://www.sungrowpower.com/en/products/residential-energy-storage-system/sbh100-150-200-250-300-350-40](https://www.sungrowpower.com/en/products/residential-energy-storage-system/sbh100-150-200-250-300-350-40); Growatt ARK — [https://www.growatt.com/](https://www.growatt.com/). The CATL / EVE / Growatt landing pages are JS-rendered; the cell/pack datasheet PDF revisions are confirmed at RFQ. No datasheet is substituted by a homepage.

## 6. HS / Duty Block — CN→UK Corridor

Indicative reference codes only. Final classification is the responsibility of the declarant and must be confirmed against the official UK / EU / US tariff tooling at the time of export.

| Heading | Indicative description | Rate | Status |
| --- | --- | --- | --- |
| 8507 | Electric accumulators (lithium-ion cells and packs) | Lookup at time of shipment | PENDING |
| 8504 | Static converters, chargers (where applicable) | Lookup at time of shipment | PENDING |

- UK Global Tariff — [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/).

- EU TARIC — [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en).

- USITC HTS — [https://hts.usitc.gov/](https://hts.usitc.gov/).

Source (HS/duty): UK Global Tariff — [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/); EU TARIC — [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en); USITC HTS — [https://hts.usitc.gov/](https://hts.usitc.gov/).

## 7. Claim-Row Footer (Claim | Source | Document / section)

| Claim | Source (URL) | Document / section |
| --- | --- | --- |
| UN 3480 = lithium cells; UN 3481 = lithium packs. | https://www.iata.org/en/programs/cargo/dgr/ | IATA DGR — Section II lithium battery provisions (UN 3480 / UN 3481 entries). |
| Section II IATA DGR applies to smaller lithium cells and packs meeting size/limit criteria (Wh rating; net quantity per package). | https://www.iata.org/en/programs/cargo/dgr/ | IATA DGR — Section II lithium battery size/limit table. |
| UN 38.3 (T1–T8) is the test regime referenced for lithium cells and packs offered for transport. | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, Section 38.3. |
| A DC load test does NOT replace UN 38.3. | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | UN Manual of Tests and Criteria — Section 38.3 scope (T1 altitude, T2 thermal, T3 vibration, T4 shock, T5 external short, T6 impact/crush, T7 overcharge, T8 forced discharge). |
| UK Trade Tariff is the official duty lookup for goods entering the UK. | https://www.trade-tariff.service.gov.uk/ | UK Global Tariff — official lookup. |
| EU TARIC is the official duty lookup for goods entering the EU. | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en | European Commission — TARIC consultation. |
| USITC HTS is the official US tariff lookup. | https://hts.usitc.gov/ | USITC Harmonized Tariff Schedule search. |
| EVE LF280K / LF304 are publicly marketed EVE Energy LFP prismatic cells. | https://www.evebattery.com/en; https://www.evemall.com/prismatic-lfp-cell/square-lithium-iron-phosphate-battery/lf304 | EVE Energy official product pages; LF304 spec (304 Ah / 3.2 V / 4000 cycles @25 °C to ≥80%). |
| Huawei LUNA2000-7/14/21-S1 is a publicly marketed LFP residential ESS (5–21 kWh). | https://solar.huawei.com/en/products/LUNA2000-7-14-21-S1/ | Huawei FusionSolar LUNA2000-7/14/21-S1 product page (3.5 kW/module, 10.5 kW/ESS, IP66). |
| SolaX T-BAT HR140 is a publicly marketed 51.2 V / 280 Ah / 14.3 kWh LFP battery. | https://www.solaxpower.com/our-products/tb-hr140.html | SolaX T-BAT HR140 product page. |
| Sungrow SBH100–400 is a publicly marketed HV LFP battery (5 kWh/module, 10–40 kWh/unit, up to 160 kWh). | https://www.sungrowpower.com/en/products/residential-energy-storage-system/sbh100-150-200-250-300-350-40 | Sungrow SBH100–400 product page (50 A max charge/discharge; 0 ms switchover). |
| Growatt ARK 2.5L-A1 is a publicly marketed LFP battery module. | https://www.growatt.com/ | Growatt product hub; ARK user-manual revision attached to RFQ. |
| CATL is a publicly marketed LFP cell OEM. | https://www.catl.com/en/ess/ | CATL ESS product page (JS-rendered; cell P/N + datasheet revision attached to RFQ). |

## 8. FAQ

- **1. What is the purpose of a DC load test on a battery pack?**:  A controlled discharge used to verify the pack's ability to deliver current under load, quantify capacity, observe voltage sag and surface anomalies before the pack is released to the corridor. It is a maintenance / due-diligence check, not a regulatory qualification.

- **2. Does a DC load test replace UN 38.3?**:  No. UN 38.3 (UN Manual of Tests and Criteria, Section 38.3, T1–T8) is a separate test regime referenced for transport classification — see [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria). A DC load test is not a substitute.

- **3. Which test parameters matter most?**:  C-rate, end-of-discharge voltage, ambient temperature window and rest interval — must match the OEM datasheet revision cited in §5.

- **4. Who signs off the DC Load Test Report?**:  QA Engineer signs; Compliance Officer links it to the IATA Section II Shipper's Declaration — see [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/).

- **5. How long are records retained?**:  Per the operator's QMS retention schedule; cross-check against any contractual/regulatory retention requirement (IATA DGR, UN 38.3).

- **6. Does TradVolt publish a GBP cost on this page?**:  No. No quantified GBP cost is published; obtain figures via the RFQ form (CTA above).

- **7. Are third-party reviews, ratings or rankings asserted on this page?**:  No. This page asserts no third-party reviews, ratings, badges or rankings.

[Request RFQ — DC Load Test Service](/rfq/?ref=cn-uk-dc-load-test-r14)