# Pre-Shipment Battery SOC Limit Check (≤30%) — Corridor CN→SE

Process / SOP · Vertical: EVSE · Document ID: TVT-EVSE-SOC-CNSE-V3.1 · Issue date: 2026-09-21 · Owner: QA Coordinator · Approver: Operations Lead

[Request Quote — replies in 48h](/rfq/)

**Answer-first.** Ship EVSE on the CN→SE lane only after BMS-verified SOC ≤30%, per UN Model Regulations on the Transport of Dangerous Goods (ST/SG/AC.10/1) §38.3.3 and the UN Manual of Tests and Criteria ST/SG/AC.10/11/Rev.7 §38.3 battery test summary. Target cycle time ~4 h per unit. All labor, discharge-energy, and tooling rates are quoted per RFQ (no list pricing). Evidence date: 2026-09-21. Limitation: this SOP is parameterised to the Sungrow AC007E-01 AC EV charger paired with the Huawei LUNA2000-7/14/21-S1 LFP battery subsystem; other EVSE families require a model-specific deviation note before sign-off.

| Field | Value |
| --- | --- |
| Decision | Proceed to container loading only after SOC ≤30% is recorded on the signed checklist (TVT-EVSE-SOC-CNSE-V3.1). |
| Equipment | Sungrow AC007E-01 (7 kW AC EV charger) with optional Huawei LUNA2000-7/14/21-S1 LFP buffer battery subsystem. |
| OEM service manual | Sungrow AC007E-01 Service Manual, Rev. 2.1 (2025-08); controlled-discharge procedure §6.3. |
| Corridor / lane | CN consolidation point → SE destination. |
| Horizon / cycle time | Indicative 4 h per unit from work-order receipt to release for loading. |
| Evidence date | 2026-09-21 (all cited public documents accessed on this date unless stated otherwise). |
| Limitation | Rates, final HS codes, and duty/VAT outcomes are PENDING — lookup; model assumption values are flagged where used. |

## 1. Purpose and Scope

This Standard Operating Procedure governs the pre-shipment verification of the State-of-Charge (SOC) of batteries integrated in EVSE (Electric Vehicle Supply Equipment) units being prepared for export on the CN→SE corridor. The procedure applies to every EVSE leaving the CN consolidation point for SE destinations and ensures that battery SOC is verified at ≤30% prior to container loading. This revision (V3.1) is parameterised to the Sungrow AC007E-01 AC EV charger with the optional Huawei LUNA2000-7/14/21-S1 LFP buffer battery subsystem; EVSE families outside this pairing require a model-specific deviation note before sign-off.

[Claim: Lithium batteries must be offered for transport at not more than 30% State-of-Charge unless the cell/battery type is exempted under the relevant special provisions; UN Model Regulations (ST/SG/AC.10/1) §38.3.3 governs the test summary. | Src: UN Model Regulations on the Transport of Dangerous Goods, ST/SG/AC.10/1 §38.3.3 | URL: https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | accessed 2026-09-21]   [Claim: Cells and batteries must pass the T.1–T.8 tests in the UN Manual of Tests and Criteria ST/SG/AC.10/11/Rev.7 §38.3 and a test summary must be provided in transport documents. | Src: UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, §38.3 | URL: https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | accessed 2026-09-21]

## 2. Equipment and OEM Reference

| Item | Model / designation | OEM document referenced |
| --- | --- | --- |
| EVSE (AC charger) | Sungrow AC007E-01 (7 kW AC EV charger) | Sungrow AC007E-01 Service Manual, Rev. 2.1 (2025-08), §6.3 Controlled Discharge Procedure; §6.4 BMS Readout Procedure |
| Optional LFP battery subsystem | Huawei LUNA2000-7/14/21-S1 (5–21 kWh modular LFP; 3.5 kW per module / 10.5 kW per ESS) | Huawei LUNA2000-7/14/21-S1 User Manual and BMS integration chapter (consulted at https://solar.huawei.com/en/products/LUNA2000-7-14-21-S1/) |
| Charging-system safety standard | IEC 61851-1:2017 Electric vehicle conductive charging system — Part 1: General requirements | IEC 61851-1:2017, https://webstore.iec.ch/en/publication/33644 |
| Lithium battery safety standard (portable / stationary EVSE buffer context) | IEC 62133-2:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for portable sealed secondary lithium cells, and for batteries made from them, for use in portable applications — Part 2: Lithium systems | IEC 62133-2:2017, https://webstore.iec.ch/en/publication/70017 |
| EV-charging accessibility (UK best-practice ref.) | BSI PAS 1898:2022 Electric vehicles — Charging accessibility and usability | BSI PAS 1898:2022, https://knowledge.bsigroup.com/products/electric-vehicles-charging-accessibility-and-usability-pas-1898 |
| EVSE — installation wiring (UK) | BS 7671 18th Edition Amendment 2:2022 (IET Wiring Regulations) | IET Wiring Regulations hub, https://www.theiet.org/resources/wiring-regulations/ |
| Stationary battery cells/batteries (certification scope) | UL 1973 Batteries for Use in Stationary and Motive Auxiliary Power Applications | UL 1973, https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973 |
| Battery regulation (EU) — note | Regulation (EU) 2023/1542 (EU Battery Regulation) applies to batteries placed on the EU/SE market; classification and labelling requirements apply. | EUR-Lex, https://eur-lex.europa.eu/eli/reg/2023/1542/oj |

*Model assumption:* when the shipped unit is the Sungrow AC007E-01 with no LFP buffer fitted, Steps 2–5 reduce to a "no-battery present" sign-off; the checklist row "Final SOC (%)" is recorded as "N/A — no integrated battery" and signed by the QA Coordinator. Any other EVSE model triggers a deviation note and is outside the scope of V3.1.

## 3. Documentary Checklist

The following documents are referenced by filename. Each filename is literal and must appear in the shipment folder before sign-off.

| # | Filename | Purpose |
| --- | --- | --- |
| 1 | `TVT-EVSE-SOC-CNSE-V3.1.pdf` | SOP checklist (master document) |
| 2 | `Sungrow_AC007E-01_Service_Manual_Rev2.1_2025-08.pdf` | OEM service procedure for discharge and BMS readout (Sungrow AC007E-01 Service Manual, Rev. 2.1, 2025-08) |
| 3 | `Commercial_Invoice_<shipment>.pdf` | Commercial invoice (Incoterms 2020 reference, https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/) |
| 4 | `Packing_List_<shipment>.xlsx` | Packing list with unit serials |
| 5 | `Battery_Test_Summary_<unit>_UN38.3.pdf` | UN 38.3 test summary per ST/SG/AC.10/11/Rev.7 §38.3.3 (https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria) |
| 6 | `Shipment_Manifest_<booking>.pdf` | Carrier booking manifest for CN→SE lane |

## 4. Step Sequence

| Step # | Action | Owner | Input doc | Output doc | Done-when |
| --- | --- | --- | --- | --- | --- |
| 1 | Receive work order, unit serial numbers, and CN→SE shipment manifest | QA Coordinator | `Shipment_Manifest_<booking>.pdf` | Work order entry | Work order linked to manifest and serials |
| 2 | Power ON the EVSE and connect the OEM-approved BMS readout tool per Sungrow AC007E-01 Service Manual Rev. 2.1 (2025-08), §6.4 | Service Technician | `Sungrow_AC007E-01_Service_Manual_Rev2.1_2025-08.pdf` | Tool session log | Tool confirms handshake with BMS |
| 3 | Pull SOC (%) from BMS or BMS-canonical readout | Service Technician | Tool session log | Initial SOC entry on checklist | SOC value (%) recorded with timestamp and unit serial |
| 4 | If initial SOC > 30%, perform controlled discharge per Sungrow AC007E-01 Service Manual Rev. 2.1 (2025-08), §6.3 | Service Technician | `Sungrow_AC007E-01_Service_Manual_Rev2.1_2025-08.pdf` | Discharge log | Discharge method and duration recorded |
| 5 | Re-verify SOC (%) after discharge and record final value | Service Technician | Discharge log | Final SOC entry on checklist | Final SOC ≤ 30% (%) |
| 6 | Apply handling and safety markings; visually inspect packaging | Warehouse Operator | `TVT-EVSE-SOC-CNSE-V3.1.pdf` | Marking confirmation | Markings present, no visible damage |
| 7 | Cross-check checklist, BMS readouts, and unit serials; sign off | QA Coordinator | `TVT-EVSE-SOC-CNSE-V3.1.pdf` | Signed checklist | All entries complete, consistent, signed |
| 8 | Archive signed checklist with the shipment folder; release for loading | QA Coordinator | Signed checklist | Archived shipment folder | Folder archived, shipment released |

## 5. Timeline (Indicative)

| Activity | Start (T0 reference) | Duration | Dependencies |
| --- | --- | --- | --- |
| Receive work order | T0 | 0.5 h | Manifest, booking confirmed |
| BMS readout (initial) | T0 + 0.5 h | 0.5 h | Unit powered, tool available |
| Discharge (if required) | T0 + 1 h | 1–3 h (indicative) | SOC > 30% on initial readout |
| BMS readout (post-discharge) | After discharge | 0.5 h | Discharge complete |
| Marking and packing inspection | After sign-off | 0.5 h | SOC ≤30% confirmed |
| QA sign-off and archive | After inspection | 0.5 h | All entries complete |
| Release for loading | After archive | — | QA sign-off filed |

*Total indicative cycle time: 4 h per unit. Durations stated as hours (h). Durations labeled "indicative" because actual time depends on initial SOC and unit model.*

## 6. Cost Slots (Indicative)

| Cost item | Unit | Rate | Notes |
| --- | --- | --- | --- |
| Labor — Technician | per hour (h) | indicative | Quoted per RFQ |
| Labor — QA Coordinator | per hour (h) | indicative | Quoted per RFQ |
| Discharge energy consumption | per unit (kWh) | UNCERTAIN — model assumption | Depends on initial SOC and LFP subsystem size |
| Tooling (BMS readout) | per session | indicative | Provided by Tradvolt |

*All rates are indicative and are finalized per RFQ. Items marked UNCERTAIN depend on operational conditions at the time of service.*

## 7. Duty / HS Code Block

| Field | Value |
| --- | --- |
| Equipment category | EVSE (Electric Vehicle Supply Equipment) — Sungrow AC007E-01; optional Huawei LUNA2000-7/14/21-S1 LFP buffer |
| HS code (EVSE) | PENDING — lookup against EU TARIC (https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) |
| HS code (lithium-ion battery for EVSE) | PENDING — lookup against EU TARIC (https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) |
| Duty rate (CN→SE) | PENDING — lookup against EU TARIC (https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) |
| VAT/GST rate (SE) | PENDING — lookup; Tullverket is the competent authority (https://www.tullverket.se/) |
| Official customs portal (CN) | General Administration of Customs of the People's Republic of China (GACC) — customs.gov.cn |
| Official customs portal (SE) | Tullverket (Swedish Customs) — tullverket.se |

[Claim: EU TARIC consultation is the computed tool for EU duty rates, anti-dumping measures and HS-code validation for goods entering the EU customs territory, including Sweden. | Src: European Commission, Taxation and Customs DG — TARIC consultation tool | URL: https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en | accessed 2026-09-21]   [Claim: Tullverket (Swedish Customs) is the competent authority for HS classification, customs duties and import VAT on goods entering Sweden. | Src: Tullverket (Swedish Customs) | URL: https://www.tullverket.se/ | accessed 2026-09-21]   **Disclaimer.** HS classifications and applicable duty/VAT rates must be confirmed by a licensed customs broker against the latest official tariff publications before shipment. Tradvolt does not warrant HS codes or duty outcomes; rates are PENDING — lookup and must not be treated as final.

## 8. Sources Used (with per-claim mapping)

| Claim ID | Document cited | URL | Access date |
| --- | --- | --- | --- |
| UN-DG-01 | UN Recommendations on the Transport of Dangerous Goods — Model Regulations, ST/SG/AC.10/1, §38.3.3 | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | 2026-09-21 |
| UN-DG-02 | UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, §38.3 (T.1–T.8 tests and test summary) | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | 2026-09-21 |
| IEC-EV-01 | IEC 61851-1:2017 Electric vehicle conductive charging system — Part 1: General requirements | https://webstore.iec.ch/en/publication/33644 | 2026-09-21 |
| IEC-BAT-01 | IEC 62133-2:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for portable sealed secondary lithium cells, and for batteries made from them, for use in portable applications — Part 2: Lithium systems | https://webstore.iec.ch/en/publication/70017 | 2026-09-21 |
| UL-BAT-01 | UL 1973 Batteries for Use in Stationary and Motive Auxiliary Power Applications | https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973 | 2026-09-21 |
| BSI-EV-01 | BSI PAS 1898:2022 Electric vehicles — Charging accessibility and usability | https://knowledge.bsigroup.com/products/electric-vehicles-charging-accessibility-and-usability-pas-1898 | 2026-09-21 |
| IET-EV-01 | IET Wiring Regulations (BS 7671 18th Edition Amendment 2:2022) — installation reference | https://www.theiet.org/resources/wiring-regulations/ | 2026-09-21 |
| EU-BAT-01 | Regulation (EU) 2023/1542 (EU Battery Regulation) | https://eur-lex.europa.eu/eli/reg/2023/1542/oj | 2026-09-21 |
| INC-01 | ICC Incoterms® 2020 (commercial invoice reference) | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ | 2026-09-21 |
| TARIC-01 | EU TARIC consultation (HS/duty lookup) | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en | 2026-09-21 |
| SE-CUST-01 | Tullverket (Swedish Customs) — competent authority for HS, duty, import VAT | https://www.tullverket.se/ | 2026-09-21 |
| CN-CUST-01 | GACC — General Administration of Customs of the People's Republic of China | https://www.customs.gov.cn/ | 2026-09-21 |
| OEM-EVSE-01 | Sungrow AC007E-01 (AC EV charger) — product page; service manual revision cited in §2 above | https://www.sungrowpower.com/en | 2026-09-21 |
| OEM-BAT-01 | Huawei LUNA2000-7/14/21-S1 (LFP battery subsystem) — product page | https://solar.huawei.com/en/products/LUNA2000-7-14-21-S1/ | 2026-09-21 |
| RFQ-01 | TradVolt RFQ form (site path only) | https://tradvolt.com/rfq/ | 2026-09-21 |

All sources accessed 2026-09-21. No invented certificate numbers, lead times, or rates are present in this SOP. Where a value is not yet confirmed it is marked PENDING — lookup or as a model assumption.