title: "Solar Cable UV-Resistance Batch Test — Corridor CN→GB | Tradvolt SOP"
source_url: "https://tradvolt.com/en/guides/solar-cable-uv-resistance-batch-test-corridor-cngb-tradvolt-sop/"
lang: "en"
description: "Standard operating procedure for solar cable UV-resistance batch testing on the China to Great Britain trade corridor, with AQL sampling, customs documentation, and Incoterms handover."
generator: "tradvolt-tier-c-edge-md"
---

TRADVOLT. Solar BoS sourcing · CN→GB

Process / SOPVertical: Solar BoSCorridor: CN → GB

# Solar cable UV-resistance batch test — corridor CN→GB

Standard operating procedure for batch-verifying the ultraviolet resistance of DC photovoltaic cable procured in China and shipped to Great Britain. Covers sampling, exposure, mechanical verification, customs release.

[Request Quote — replies in 48h](/rfq?topic=solar-cable-uv-test&corridor=cn-gb) Download Batch Test Checklist (PDF)   **Scope.** Applies to lots of `PV1-F / H1Z2Z2-K`-class double-insulated solar DC cable sourced from a Chinese OEM and imported under standard commercial terms to a GB-based solar EPC, distributor, or installer. Pair this SOP with the OEM datasheet and the active CCC / UKCA-UK technical file referenced in [Compliance](/guides/).

## 1. Reference framework

Every step below is anchored to an allow-listed source. Where a fact could change (duty rates, HS classification notes), the entry is marked accordingly.

| Item | Reference | Source name | URL | Accessed |
| --- | --- | --- | --- | --- |
| PV wire designation | IEC 62930 / EN 50618 | IEC (International Electrotechnical Commission) | https://www.iec.ch/ | 2026-09-21 |
| Artificial weathering | IEC 60068-2-5 | IEC | https://www.iec.ch/ | 2026-09-21 |
| Mechanical tests on insulation/sheath | IEC 60811-501 | IEC | https://www.iec.ch/ | 2026-09-21 |
| AQL sampling plan | ISO 2859-1 | ISO (International Organization for Standardization) | https://www.iso.org/ | 2026-09-21 |
| Trade term handover | Incoterms® 2020 | ICC (International Chamber of Commerce) | https://iccwbo.org/ | 2026-09-21 |
| GB customs declaration | CDS — Customs Declaration Service | GOV.UK (HMRC official portal) | https://www.gov.uk/guidance/get-access-to-the-customs-declaration-service | 2026-09-21 |
| Tariff classification lookup | UK Integrated Online Tariff | GOV.UK (HMRC official portal) | https://www.trade-tariff.service.gov.uk/ | 2026-09-21 |

## 2. Claim row — facts and figures

| Claim | Source name | URL | Accessed |
| --- | --- | --- | --- |
| Insulated wire and cable is classified under Chapter 85 of the Harmonized System, and solar DC cable of the H1Z2Z2-K / EN 50618 family is typically declared under heading 8544 (insulated conductors, optical fibre cables). Exact sub-heading is product-specific and must be confirmed against the UK Integrated Online Tariff. | GOV.UK (HMRC official portal) | https://www.trade-tariff.service.gov.uk/ | 2026-09-21 |
| GB import duty and VAT treatment for insulated conductors depends on the exact 10-digit commodity code; rates are looked up at the time of entry on the UK Integrated Online Tariff. | GOV.UK (HMRC official portal) | https://www.trade-tariff.service.gov.uk/ | 2026-09-21 |
| Incoterms® 2020 defines the transfer of risk and cost between seller and buyer; the agreed term (e.g., FOB, CIF, DAP) must be stated on the commercial invoice. | ICC (International Chamber of Commerce) | https://iccwbo.org/ | 2026-09-21 |
| AQL sampling plans for attribute inspection are defined in ISO 2859-1, with separate tables for normal, reduced, and tightened inspection at common AQL levels of 1.0 and 2.5. | ISO (International Organization for Standardization) | https://www.iso.org/ | 2026-09-21 |
| Artificial UV weathering of cable materials can be performed per IEC 60068-2-5, with exposure parameters matched to the OEM datasheet claim. | IEC | https://www.iec.ch/ | 2026-09-21 |
| Tensile strength and elongation-at-break of insulation and sheath after ageing are tested per IEC 60811-501, with results compared to the unaged baseline. | IEC | https://www.iec.ch/ | 2026-09-21 |
| Solar PV wire intended for DC string and inverter interconnection is standardized in IEC 62930 and EN 50618, including the H1Z2Z2-K designation and UV-resistance requirements. | IEC | https://www.iec.ch/ | 2026-09-21 |
| GB import declarations are lodged through the Customs Declaration Service (CDS); access is managed via GOV.UK guidance. | GOV.UK (HMRC official portal) | https://www.gov.uk/guidance/get-access-to-the-customs-declaration-service | 2026-09-21 |

## 3. Procedure — step sequence

| Step # | Action | Owner | Input doc | Output doc | Done-when |
| --- | --- | --- | --- | --- | --- |
| 1 | Confirm cable designation (e.g., H1Z2Z2-K, 4 mm² / 6 mm²), voltage rating, and applicable standard against IEC 62930 / EN 50618. | Tradvolt QA lead | Buyer RFQ, OEM catalogue | Scope memo | Scope memo signed and filed to the project folder. |
| 2 | Request the OEM datasheet, CoC, and UV-resistance claim with reference to the named IEC / EN standard and exposure duration. | Tradvolt sourcing | OEM datasheet request email | OEM CoC packet | CoC packet received and checked against the cable label markings. |
| 3 | Select the AQL level and lot size, then read sample size, Ac, and Re from the ISO 2859-1 table for normal inspection. | Tradvolt QA lead | ISO 2859-1 | AQL sampling plan | Sampling plan countersigned by the OEM and the buyer. |
| 4 | Draw the sample units randomly from the lot, seal and tag each unit with batch/lot ID, and log the chain of custody. | OEM QC + Tradvolt surveyor | Lot register, seal log | Chain-of-custody form | Chain-of-custody form signed by both parties. |
| 5 | Expose specimens in the weathering chamber per IEC 60068-2-5 (xenon-arc or UV-A 340 nm) for the duration named on the OEM datasheet. | OEM lab (or accredited 3rd-party lab) | Chamber run sheet, OEM datasheet | Exposure run report | Exposure run report countersigned by the lab operator. |
| 6 | Run tensile strength and elongation-at-break on exposed and unexposed specimens per IEC 60811-501 and compare results. | OEM lab / 3rd-party lab | Specimens, IEC 60811-501 | Mechanical test sheet | Mechanical test sheet filed with the Batch Test Report. |
| 7 | Visually inspect each specimen for cracking, chalking, discoloration, or embrittlement against the visual AQL sheet. | Tradvolt QA lead + OEM QC | Visual AQL sheet | Visual inspection record | Inspection record shows accept or reject against the ISO 2859-1 Ac/Re numbers. |
| 8 | Compile the Batch Test Report: sample IDs, conditions, mechanical results, visual results, and a pass/fail statement. | Tradvolt QA lead | Exposure run report, mechanical sheet, visual record | Batch Test Report (PDF) | Batch Test Report is signed and distributed to the buyer. |
| 9 | Prepare commercial invoice, packing list, CoC, and SDS; lodge the GB customs declaration through CDS per GOV.UK guidance. | Tradvolt logistics + customs broker | Commercial invoice, CoC, SDS, packing list | CDS acceptance receipt | CDS acceptance receipt obtained and the EORI is logged. |
| 10 | Confirm the agreed ICC Incoterms® 2020 term on the shipping instruction (e.g., FOB Shanghai, CIF Felixstambuk, DAP buyer warehouse). | Tradvolt logistics + buyer | Sales contract, shipping instruction | Shipping instruction | Both parties countersign the shipping instruction naming the Incoterm. |
| 11 | Release the lot for loading once the Batch Test Report is signed, the CoC is filed to the shipment, and the customs entry is accepted. | Tradvolt logistics + OEM warehouse | Batch Test Report, CDS receipt | Pre-shipment release note | Pre-shipment release note archived against the Bill of Lading. |
| 12 | Close out the project: archive the Batch Test Report, AQL sheet, customs receipts, and Bill of Lading; send the close-out pack to the buyer. | Tradvolt QA lead | All step outputs | Close-out pack | Close-out pack delivered and the project is marked closed in the CRM. |

## 4. Acceptance and AQL reference

The batch is accepted when the number of defective units in the sample is ≤ the Ac number from the ISO 2859-1 table for the chosen AQL level and inspection severity. Common starting points:

- AQL **1.0** for mechanical / electrical attributes that affect safety.

- AQL **2.5** for visual attributes such as marking, colour, and surface finish.

Always read the actual Ac/Re figures from the live ISO 2859-1 table at the time of inspection; the numbers above are reference levels only.

## 5. Duty and HS block (REQUIRED)

| Field | Value |
| --- | --- |
| Goods description | Insulated solar DC cable, typically H1Z2Z2-K / EN 50618 class. |
| Harmonized System chapter | Chapter 85 — Electrical machinery and equipment. |
| HS heading (insulated conductors / optical fibre cables) | 8544 |
| Exact 10-digit UK commodity code | **PENDING — lookup** on the UK Integrated Online Tariff at the time of entry. |
| Import duty rate | **PENDING — lookup** on the UK Integrated Online Tariff for the confirmed commodity code. |
| VAT treatment | **PENDING — lookup** on GOV.UK at the time of entry. |
| Additional duties (e.g., anti-dumping, safeguards) | **PENDING — lookup** for the confirmed commodity code at the time of entry. |
| Official tariff portal | UK Integrated Online Tariff (GOV.UK / HMRC). |
| Portal URL | https://www.trade-tariff.service.gov.uk/ |
| Declaration portal | Customs Declaration Service (CDS) — GOV.UK. |
| Declaration portal URL | https://www.gov.uk/guidance/get-access-to-the-customs-declaration-service |

**Disclaimer.** HS classification, import duty rates, VAT treatment, and any additional duties are looked up on the official GOV.UK / HMRC portal at the time of each entry. Tradvolt does not hardcode or guarantee duty figures; the values shown as *PENDING — lookup* must be confirmed by the importer or their customs broker before declaration.

## 6. Cost slots — indicative only

| Cost slot | Status | Note |
| --- | --- | --- |
| Unit price (USD per metre) | indicative | Per OEM offer letter; subject to copper price, conductor size, and lot volume. |
| Lab / batch test fee (USD per lot) | indicative | Per accredited lab quotation; varies with AQL sample size and exposure duration. |
| Pre-shipment inspection (USD per manday) | indicative | Per surveyor quotation. |
| Ocean freight CN→GB (USD per CBM or per container) | indicative | Per freight forwarder rate sheet at booking. |
| Import duty (UK) | UNCERTAIN | **PENDING — lookup** on the UK Integrated Online Tariff. |
| VAT (UK) | UNCERTAIN | **PENDING — lookup** on GOV.UK at the time of entry. |
| Customs broker fee (GBP per entry) | indicative | Per broker quotation. |
| Insurance (% of CIF) | indicative | Per insurer quotation; required for CIF / CIP terms per ICC Incoterms® 2020. |

## 7. Indicative timeline

| Phase | Indicative duration | Dependency |
| --- | --- | --- |
| Sample draw and chain of custody (Steps 3–4) | 1–2 working days after lot is ready | OEM confirms lot completion; ISO 2859-1 sample plan signed. |
| Weathering exposure (Step 5) | defined by OEM datasheet / IEC 60068-2-5 | Cannot start until specimens are conditioned and chamber slot is booked. |
| Mechanical and visual verification (Steps 6–7) | 2–4 working days post-exposure | Exposure complete; lab capacity available. |
| Batch Test Report (Step 8) | 1 working day after tests | All lab sheets signed. |
| Customs and shipping set (Steps 9–10) | 2–3 working days | Commercial invoice and CoC received; CDS access active; Incoterm agreed. |
| Loading and pre-shipment release (Step 11) | 1 working day | Batch Test Report signed, CDS entry accepted, container available. |
| Sea transit CN→GB | approx. 28–35 days (indicative) | Per carrier sailing and port congestion. |
| Close-out (Step 12) | 1–2 working days after arrival | Bill of Lading, customs receipts, and BTR archived. |

Durations are indicative and depend on OEM capacity, chamber slot, lab queue, and ocean carrier schedule. Confirm each leg in writing before booking.

## 8. Document checklist (literal filenames)

Use these filenames in the project folder so every shipment on the CN→GB corridor is searchable in one convention:

- `01_scope_memo_CN__GB.docx`

- `02_oem_datasheet_H1Z2Z2-K.pdf`

- `03_oem_coc_H1Z2Z2-K.pdf`

- `04_aql_sampling_plan_ISO2859-1.xlsx`

- `05_chain_of_custody.pdf`

- `06_exposure_run_report_IEC60068-2-5.pdf`

- `07_mechanical_test_IEC60811-501.xlsx`

- `08_visual_inspection_AQL.xlsx`

- `09_batch_test_report.pdf`

- `10_commercial_invoice.pdf`

- `11_packing_list.pdf`

- `12_sds_solar_cable.pdf`

- `13_cds_acceptance_receipt.pdf`

- `14_shipping_instruction_Incoterms2020.pdf`

- `15_bill_of_lading.pdf`

- `16_close_out_pack.zip`

A printable copy of items 04, 07, 08, 09 and 16 is also available in the Batch Test Checklist (PDF).

## 9. Risk and rework triggers

- **Ac exceeded on visual AQL sheet** — trigger a tightened ISO 2859-1 inspection on the next lot and raise a non-conformance to the OEM.

- **Mechanical result below OEM datasheet limit** — quarantine the lot, request OEM root-cause analysis, and consider retesting with extended conditioning.

- **CoC missing or mismatched standard** — hold the lot and request a corrected CoC before customs declaration; do not declare with a non-matching CoC.

- **HS code / duty rate not confirmed** — block customs declaration until the commodity code is confirmed on the UK Integrated Online Tariff; do not estimate.

## 10. Related Tradvolt pages

- [All process SOPs](/process/)

- [Solar BoS vertical](/use-cases/)

- CN→GB logistics lane

- [Compliance hub](/guides/)

[Request Quote — replies in 48h](/rfq?topic=solar-cable-uv-test&corridor=cn-gb) Download Batch Test Checklist (PDF)