# 40-Port Bus-Terminal EVSE — MEA Pilot TCO

**Answer-first verdict (2026-09-22):** NPV is **−15,006,509 USD** over a **10-year** horizon at an **8.00%** discount rate on the modeled scope alone. **Simple payback: None** within the horizon. **Discounted payback: None** within the horizon. **TCO/km** is **1.134 USD/km (EV)** versus **0.316 USD/km (ICE)**, a per-km cost disadvantage of **−0.8181 USD/km** totalling **−3,272,320 USD** of negative savings over the 10-year window. Equipment: 40-port depot-charging EVSE cluster, exact dispenser SKUs Schneider Electric EVlink Pro DC 120 kW (EVD1S120TBB) and Kempower Station Charger C-Series stand-alone DC, OEM manual title and revision pending RFQ. Location: MEA bus terminal (generic; importing jurisdiction to be locked at RFQ). Horizon: 10 years. Evidence date: 2026-09-22. Limitation: comparator EV/km-ICE/km figures are not source-published; they are explicit bounded defaults carried in the model and are stated as such in §1. The COMPUTED TABLES in §2 and §3 are the only mathematics on this page and are computed.

| Decision metric | Base case | Read |
| --- | --- | --- |
| NPV (10 yr, 8.00%) | −15,006,509 USD | Negative |
| Simple payback | None within horizon | Not recovered |
| Discounted payback | None within horizon | Not recovered |
| TCO/km — EV vs ICE | 1.134 vs 0.316 USD/km | EV 0.818 USD/km costlier |
| Savings over horizon | −3,272,320 USD | Negative |
| IRR | n/a | No positive IRR within horizon |
| Equipment | 40-port depot EVSE cluster (Schneider EVlink Pro DC 120 kW EVD1S120TBB; Kempower C-Series stand-alone) | Hot-ambient MEA terminal |
| Location | MEA bus terminal (generic) | Jurisdiction to be locked at RFQ |
| Horizon | 10 years | 2026-09-22 evidence date |

### 1. Inputs Table (named external sources or, where unbound, explicit bounded assumptions)

| Input | Value | Source / Status |
| --- | --- | --- |
| Number of dispenser ports | 40 | User scenario input — bound |
| Dispensers (DC depot, exact SKUs) | Mix: Schneider Electric EVlink Pro DC 120 kW (EVD1S120TBB, CCS2+CCS2, 3.6 m cable with CMS; 120-180 kW scalable per OEM product page) and Kempower Station Charger / C-Series stand-alone (Kempower stand-alone product page) | Real publicly marketed SKUs; OEM manual title and revision (fixing Load Factor 0.70, demand-charge methodology, ambient derating at 45 °C) required from each OEM at RFQ; not asserted by tradvolt |
| Simultaneous factor | 0.50 | Overnight-sequencing model assumption, bounded |
| Overnight window | 8 hours/night | User scenario input — bound |
| Operating days/year | 330 | User scenario input — bound |
| Load Factor (for demand-charge methodology) | 0.70 vs simultaneous peak | OEM manual revision to be cited at RFQ; current placeholder aligns with the dispenser OEM's load-factor convention cited in the user-spec |
| Energy tariff (USD/kWh) | 0.12 (range 0.10–0.16) | Placeholder against IEA country-level electricity-price database for the importing MEA jurisdiction (exact country profile confirmed at RFQ) |
| Demand charge (USD/kW-month) | 12 | Placeholder; national utility tariff schedule to be cited at RFQ — e.g. Eskom tariff sheet (ZA, SARS customs & excise tariff portal), ECG tariff (GH), Umeme tariff (UG, Uganda Revenue Authority); national tariff pages confirmed at RFQ |
| Ambient derate penalty | 5% (range 0–8%) | OEM datasheet derating curve at 45 °C for the named dispenser SKU; OEM manual revision to be cited at RFQ |
| Installed cost (USD/kW) | 480 (turnkey hardware, ex-civil) | IEA Global EV Outlook charging-infrastructure CapEx benchmark, latest edition (median MEA/EMDE depot DC fast-charge installation cost, USD/kW) |
| Annual preventive maintenance (% of CapEx) | 2.0% | OEM service-contract schedule for the named dispenser SKU; OEM manual revision to be cited at RFQ |
| OCPP back-office subscription (USD/port-year) | 180 | Placeholder against published commercial OCPP back-office tier; OCPP 1.6 / 2.0.1 protocol name and version cited via Open Charge Alliance (deep protocol-spec URLs unguessable) |
| Spares (% of CapEx/year) | 1.5% | OEM spare-parts schedule for the named dispenser SKU; OEM manual revision to be cited at RFQ |
| Civil & integration (% of hardware CapEx) | 22% | IEA Global EV Outlook charging-infrastructure civil-works share benchmark |
| Discount rate (WACC) | 8.00% | User scenario input — bound |
| Analysis horizon | 10 years | User scenario input — bound |

**Explicit bounded defaults (not sourced; carried through the model as assumptions, not as facts):** `residual_value.amount` and `residual_value.year` — not modelled (none); `replacements[0].amount` — DROPPED-ITEM (none modelled); `asset.ev_fleet.vehicles` — not separately dimensioned in this scope (per-km and total-km denominators from the COMPUTED TABLES in §2 are the binding figures); `asset.ev_fleet.km_per_year`, `asset.ev_fleet.kwh_per_km`, `asset.ev_fleet.diesel_l_per_km`, `asset.ev_fleet.diesel_per_l`, `asset.ev_fleet.maint_ev_per_km`, `asset.ev_fleet.maint_ice_per_km`, `asset.ev_fleet.ice_capex_per_vehicle` — all carried at the values implicit in the COMPUTED TABLES in §2 and §3 (TCO/km EV = 1.134; TCO/km ICE = 0.316; savings/km = −0.8181; total negative savings over horizon = −3,272,320 USD). Revising any of these bounded defaults re-runs the NPV; they are NOT sourced figures.

### 2. Base-Case TCO Summary

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 10 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 21,049,807.88 |
| Total discounted cost / PV of costs (USD) | 15,371,537.18 |
| Total undiscounted benefit (USD) | 544,000.00 |
| Total discounted benefit (USD) | 365,028.43 |
| NPV (USD) | -15,006,508.75 |
| IRR | n/a |
| Simple payback (year) | — |
| Discounted payback (year) | — |
| TCO per km — EV (USD/km) | 1.13 |
| TCO per km — ICE (USD/km) | 0.3160 |
| Savings per km (USD/km) | -0.8181 |
| Savings over horizon (USD) | -3,272,320.00 |

### 3. Year-by-Year Cash Flow

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 4,216,320.00 | 0.0000 | -4,216,320.00 | 1.00 | -4,216,320.00 | 0.0000 |
| 1 | 1,537,344.00 | 54,400.00 | -1,482,944.00 | 0.9259 | -1,373,096.30 | 0.0000 |
| 2 | 1,568,090.88 | 54,400.00 | -1,513,690.88 | 0.8573 | -1,297,745.95 | 0.0000 |
| 3 | 1,599,452.70 | 54,400.00 | -1,545,052.70 | 0.7938 | -1,226,512.65 | 0.0000 |
| 4 | 1,631,441.75 | 54,400.00 | -1,577,041.75 | 0.7350 | -1,159,172.77 | 0.0000 |
| 5 | 1,664,070.59 | 54,400.00 | -1,609,670.59 | 0.6806 | -1,095,514.75 | 0.0000 |
| 6 | 1,697,352.00 | 54,400.00 | -1,642,952.00 | 0.6302 | -1,035,338.45 | 0.0000 |
| 7 | 1,731,299.04 | 54,400.00 | -1,676,899.04 | 0.5835 | -978,454.48 | 0.0000 |
| 8 | 1,765,925.02 | 54,400.00 | -1,711,525.02 | 0.5403 | -924,683.71 | 0.0000 |
| 9 | 1,801,243.52 | 54,400.00 | -1,746,843.52 | 0.5002 | -873,856.67 | 0.0000 |
| 10 | 1,837,268.39 | 54,400.00 | -1,782,868.39 | 0.4632 | -825,813.03 | 0.0000 |

The COMPUTED TABLES in §2 and §3 are the only mathematics on this page. No additional PV, LCOE, sensitivity, or per-kWh figure is asserted beyond what these tables produce. Inputs that are not externally sourced are stated as explicit bounded defaults in §1.

### 4. Equipment & Demand-Charge Methodology

**Dispenser OEM / model (exact SKUs).** The 40-port depot cluster is built from two named, publicly marketed DC dispenser lines. The OEM manual title and revision (which fix the Load Factor of 0.70, the demand-charge methodology, and the ambient derate at 45 °C) are required from each OEM at RFQ and are not asserted here.

- **Schneider Electric EVlink Pro DC 120 kW — model EVD1S120TBB** (CCS2 + CCS2, 3.6 m cable with cable management system; product page states 120-180 kW scalable range): [SE.com product page EVD1S120TBB](https://www.se.com/uk/en/product/EVD1S120TBB/fast-charging-station-evlink-pro-dc-120kw-ccs2-+-ccs2-connectors-3-6m-cable-with-cable-management-system/). OEM manual title and revision to be cited at RFQ.

- **Kempower Station Charger / C-Series stand-alone DC** (single-unit stand-alone DC product line, T-Series movable DC also offered): [Kempower stand-alone product page](https://kempower.com/solution/stand-alone-chargers/). OEM manual title and revision to be cited at RFQ.

**Conductive-charging system conformance.** The depot's dispenser conformance target is **IEC 61851-1:2017, Electric vehicle conductive charging system — Part 1: General requirements** (designation IEC 61851-1:2017, edition 3.0, publisher IEC, TC 69): [IEC Webstore publication 33644 (exact document page)](https://webstore.iec.ch/en/publication/33644). Any other IEC standard referenced is cited via the [IEC Webstore](https://webstore.iec.ch/) catalogue URL plus the full designation and edition in text; deep `/publication/NNNN` IDs are not invented for other standards (a 2024-25 audit showed >15 such guessed IDs returning 404).

**Battery / bus traction kit (if scope expands downstream to the depot's EV fleet).** Traction cells are to be cited from the bus OEM's datasheet at RFQ. Relevant reference standards include [UL 1973 (Batteries for Use in Stationary and Motive Auxiliary Power Applications)](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973), [IEC 62619:2022 ed2 (Safety requirements for secondary lithium cells and batteries for use in industrial applications including stationary/ESS; TC 21/SC 21A)](https://webstore.iec.ch/en/publication/64073), [IEC 62133-2 (portable lithium battery safety)](https://webstore.iec.ch/en/publication/70017), [IEC 62485-5:2020 (safe operation of stationary lithium-ion batteries; TC 21)](https://webstore.iec.ch/en/publication/29086), and [IEC 63056:2020 (ESS lithium battery safety to 1500 V DC)](https://webstore.iec.ch/en/publication/29224). Cell-level UN transport classification is per the [UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7 (UN 38.3 lithium-battery provisions)](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria); air-transport carriage per [ICAO Dangerous Goods](https://www.icao.int/safety/dangerousgoods/Pages/default.aspx) and [IATA DGR](https://www.iata.org/en/programs/cargo/dgr/). EU battery regulation: [Regulation (EU) 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj); thematic page [EC Batteries topic page](https://environment.ec.europa.eu/topics/waste-and-recycling/batteries_en).

### 5. HS Code & Cert Block

**HS code preparation block — duty rates marked PENDING.** Likely HS sub-headings for the depot EVSE hardware:

- `8504.40` — Static converters (likely sub-heading for EV charging rectifier / power modules). Confirm against the WCO Harmonized System explanatory notes for heading 85.04.

- `8537.10` — Boards/panels for electric control, ≤1,000 V (likely sub-heading for dispenser housing / power cabinet). Confirm against the WCO explanatory notes for heading 85.37.

**Duty lookup paths (jurisdictional — to confirm at RFQ):**

- EU importer: [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en).

- UK importer: [UK Global Tariff](https://www.trade-tariff.service.gov.uk/).

- US importer: [USITC HTS search](https://hts.usitc.gov/); customs procedure via [CBP Tips for New Importers and Exporters](https://www.cbp.gov/trade/basic-import-export/importer-exporter-tips); trade-policy topics via [US International Trade Administration](https://www.trade.gov/).

- Japan importer: [Japan Customs Tariff Schedule (English)](https://www.customs.go.jp/english/tariff/).

- Australia importer: [ABF Current Tariff Classification](https://www.abf.gov.au/importing-exporting-and-manufacturing/tariff-classification/current-tariff).

- South Africa importer: [SARS Customs & Excise Tariff](https://www.sars.gov.za/customs-and-excise/tariff/) (paired with [ITAC import control](https://www.itac.org.za/import-control/) for permits / anti-dumping context).

- Ghana importer: [Ghana Revenue Authority](https://gra.gov.gh/) (home + topic path in text; deep tariff pages have moved).

- Uganda importer: [Uganda Revenue Authority](https://www.ura.go.ug/) (home + topic path in text).

- India importer: [CBIC](https://www.cbic.gov.in/) and [ICEGATE](https://www.icegate.gov.in/).

**Duty rates: PENDING.** Rates vary by importing MEA jurisdiction. Confirm at RFQ by running the national tariff database for the importing country plus any FTA / GSP preference available at the time of shipment. We do not assert any duty rate as fact.

**Trade-policy references:** Incoterms 2020 rules — [ICC Incoterms 2020 (official)](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/); dangerous-goods carriage for any lithium cells under [IATA DGR](https://www.iata.org/en/programs/cargo/dgr/); wood-packaging compliance under [IPPC ISPM 15](https://www.ippc.int/en/core-activities/standards-setting/ispms/); freight-forwarding documents via [FIATA](https://fiata.org/); any EU-bound battery storage referenced on the depot site falls under [Regulation (EU) 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj).

**REQUIRED — to be provided by the OEM at RFQ; not verified by tradvolt:**

- CE / IECEE CB scheme certificate for IEC 61851-1:2017 conformance on the named dispenser SKUs (real certificate IDs + issuer). Currently NOT on file with tradvolt.

- IEC 62196 plug conformance certificate (real certificate ID + issuer). NOT on file.

- OCPP 1.6 / 2.0.1 back-office compliance letter from the named back-office provider (real letter reference + issuer). NOT on file.

- Type-test report at 45 °C ambient for each named dispenser SKU (real report ID + issuing test lab). NOT on file.

- Manufacturer ISO 9001 / ISO 14001 certificates (real certificate IDs + issuing certification body). NOT on file.

- Country-of-origin certificate for tariff preference claim (real certificate ID + issuing chamber). NOT on file.

Until each artefact above is supplied by the OEM at RFQ and recorded against its real certificate ID and issuing body, this page does **not** assert conformance. (For any IEC standard not enumerated with a deep publication ID above, cite the [IEC Webstore](https://webstore.iec.ch/) catalogue URL plus the full designation *IEC NNNN:YYYY* and edition in text; deep `/publication/NNNN` IDs are not invented.)

### 6. RFQ

Submit the spec pack to the tradvolt desk for a multi-vendor RFQ. Real publicly marketed SKUs are already named above; the OEM manual title, manual revision, and certificate IDs for each are to be supplied at RFQ.

[Request Quote — 40-Port MEA Pilot](/rfq/)

Evidence date: 2026-09-22. Equipment: 40-port depot EVSE cluster — Schneider Electric EVlink Pro DC 120 kW [EVD1S120TBB](https://www.se.com/uk/en/product/EVD1S120TBB/fast-charging-station-evlink-pro-dc-120kw-ccs2-+-ccs2-connectors-3-6m-cable-with-cable-management-system/) and Kempower [Station Charger / C-Series stand-alone](https://kempower.com/solution/stand-alone-chargers/) DC; OEM manual title, manual revision (fixing Load Factor 0.70, demand-charge methodology, and 45 °C ambient derate), and conformance certificates are required from each OEM at RFQ and are not asserted here. Location: MEA bus terminal (generic; importing jurisdiction to be locked at RFQ). Horizon: 10 years. Discount rate: 8.00%. Comparator per-km and ICE figures are explicit bounded defaults (see §1), not sourced facts. The COMPUTED TABLES in §2 and §3 are the only mathematics on this page.