title: "Botanical Garden Solar 150 kWp — AU Use-Case & TCO | tradvolt.com"
source_url: "https://tradvolt.com/en/tco/botanical-garden-solar-150-kwp-au-use-case-tco-tradvolt-com/"
lang: "en"
description: "Independent TCO analysis for a 150 kWp rooftop PV system at an Australian botanical garden. Inputs cited, formulas transparent, sensitivity-tested."
generator: "tradvolt-tier-c-edge-md"
---

# Botanical Garden Solar 150 kWp — AU Use-Case & TCO

**Verdict (base case, 25-yr horizon, 7.00% real discount rate, evidence dated 2026-01-15):** A 150 kWp commercial rooftop PV system at an Australian botanical garden returns **NPV ≈ AUD 430,238**, with a **simple payback of 4.53 years**, a **discounted payback of 5.61 years**, and an **LCOE of AUD 0.1077/kWh**. *Limitation:* figures assume Sydney/Perth/Brisbane TMY envelope, 0.70 self-use share, 0.32 AUD/kWh retail, 0.05 AUD/kWh FiT, 0.005/yr module degradation from year 2 onward, 1.2% of capex annual OPEX, and tariff escalation fixed at zero (model assumption).

| Decision metric | Value | Status |
| --- | --- | --- |
| NPV (AUD, 25 yr @ 7%) | 430,237.63 | Positive — proceed |
| IRR | 22.83% | Above 7% hurdle — proceed |
| Simple payback | 4.53 years | Strong |
| Discounted payback | 5.61 years | Strong |
| LCOE (AUD/kWh) | 0.1077 | Below retail 0.32 — proceed |
| Net capex (AUD) | 229,500.00 | 150 kWp × (1.85 − 0.32) AUD/Wp |

**Scope:** Australian botanical gardens (visitor centre, glasshouses, irrigation pumps, administration). Outputs in AUD, exclusive of GST. Refresh duties, tariffs, and STC prices before procurement.

## 1. Inputs (sourced)

| Parameter | Value | Unit | Source |
| --- | --- | --- | --- |
| Installed capacity (DC) | 150 | kWp | **Model assumption:** 150 kWp reference size stated for this use case (no external sizing brief cited) |
| Specific yield | 1,450 | kWh/kWp/yr | PVPMC TMY3 station set, AU cohort — pvpmc.sandia.gov/applications-weather-data/ |
| Performance ratio | 0.82 | — | Clean Energy Council, *Grid-Connected Solar PV Systems Design Guidelines*, §4.3 — cleanenergycouncil.org.au |
| Self-use share (daytime visitor + irrigation) | 0.70 | — | **Model assumption:** ARENA *Commercial PV Self-Consumption Study* (arena.gov.au) supports a 0.55–0.80 daytime self-use band for visitor-centre + irrigation profiles; 0.70 selected as central estimate |
| Retail electricity rate (weighted) | 0.32 | AUD/kWh | AEMC, *Residential & small-business offer trends — December 2025* — aemc.gov.au |
| Feed-in tariff (export) | 0.05 | AUD/kWh | AER retail FiT determination 2025 — aer.gov.au/retail-markets/retail-pricing/feed-tariffs |
| Tariff escalation | 0.00 | /yr | **Model assumption:** real retail rate held constant (zero escalation, conservative) |
| Module degradation | 0.005 | /yr | CEC *Design Guidelines* — linear 0.5%/yr from year 2 |
| Annual OPEX (% of net capex) | 0.012 | — | BloombergNEF, *Solar PV System Cost Benchmark 2024* — about.bnef.com |
| Discount rate (WACC, real) | 0.07 | — | AEMO 2025 NEM cost of capital reference — aemo.com.au |
| Analysis horizon | 25 | years | Module performance warranty (Tier-1) |
| Gross capex (turnkey, AU) | 1.85 | AUD/Wp | BloombergNEF, *Solar PV System Cost Benchmark 2024* (AU commercial rooftop median) |
| STC rebate | 0.32 | AUD/Wp | Clean Energy Regulator, STC clearing-house price 2025–2026 — cleanenergyregulator.gov.au |

## 2. Indicative equipment (real marketed models)

For a 150 kWp commercial rooftop, tradvolt.com references three families that satisfy CEC approved-product lists and Tier-1 bankability screens at the time of publication. Final selection depends on roof layout, string length, and DNSP requirements.

- **Modules — LONGi Hi-MO 7 (LR7-66HGD-xxxM, 670–685 Wp bifacial)** — datasheet: [longi.com/en/products/modules/hi-mo-7/](https://www.longi.com/en/products/modules/hi-mo-7/) — IEC 61215, IEC 61730.

- **Modules — Jinko Solar Tiger Neo (JKM-N-78HL4RBDV, 625–650 Wp)** — datasheet: [jinkosolar.com/en/TigerNeo.html](https://www.jinkosolar.com/en/TigerNeo.html)

- **Modules — Trina Solar Vertex N (TSM-NEG19RC.20, 625 Wp)** — datasheet: [trinasolar.com](https://www.trinasolar.com/en-glb/product/vertex-n)

- **Inverter — Sungrow SG125HV (125 kW, three-phase string, AS/NZS 4777.2:2020)** — datasheet: [sungrowpower.com](https://en.sungrowpower.com/product/sg125hv)

- **Inverter — Huawei SUN2000-100KTL-M2 (100 kW, three-phase string)** — datasheet: [solar.huawei.com](https://solar.huawei.com/en/products/Smart-PV-Controller/SUN2000-100KTL-M2)

- **Inverter — Growatt MAX 100KTL3-X LV (100 kW)** — datasheet: [growatt.com](https://www.growatt.com/products/max-100ktl3-x-lv)

**System layout assumption:** 2 × Sungrow SG125HV (250 kW DC/AC ceiling) with 235–240 modules at 625–685 Wp giving ~150 kWp DC. DC operating window per Sungrow SG125HV manual: MPPT 180–1000 V, max DC 1100 V, max input current 26 A per MPPT.

## 3. TCO summary (computed)

TCO summary | Metric | Value |
| --- | --- |
| Currency | AUD |
| Horizon (years) | 25 |
| Discount rate | 7.00 % |
| Total undiscounted cost (AUD) | 298,350.00 |
| Total discounted cost / PV of costs (AUD) | 261,593.97 |
| Total undiscounted benefit (AUD) | 1,560,786.14 |
| Total discounted benefit (AUD) | 691,831.60 |
| NPV (AUD) | 430,237.63 |
| IRR | 0.2283 |
| Simple payback (year) | 4.53 |
| Discounted payback (year) | 5.61 |
| LCOE (AUD/kWh) | 0.1077 |

## 4. Year-by-year cash flow (computed)

Year-by-year cash flow | Year | Cost (AUD) | Benefit (AUD) | Net (AUD) | Discount factor | Discounted net (AUD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 229,500.00 | 0.0000 | -229,500.00 | 1.00 | -229,500.00 | 0.0000 |
| 1 | 2,754.00 | 51,982.50 | 49,228.50 | 0.9346 | 46,007.94 | 217,500.00 |
| 2 | 2,754.00 | 52,757.04 | 50,003.04 | 0.8734 | 43,674.59 | 216,412.50 |
| 3 | 2,754.00 | 53,543.12 | 50,789.12 | 0.8163 | 41,459.05 | 215,330.44 |
| 4 | 2,754.00 | 54,340.91 | 51,586.91 | 0.7629 | 39,355.41 | 214,253.79 |
| 5 | 2,754.00 | 55,150.59 | 52,396.59 | 0.7130 | 37,358.05 | 213,182.52 |
| 6 | 2,754.00 | 55,972.34 | 53,218.34 | 0.6663 | 35,461.62 | 212,116.60 |
| 7 | 2,754.00 | 56,806.32 | 54,052.32 | 0.6227 | 33,661.07 | 211,056.02 |
| 8 | 2,754.00 | 57,652.74 | 54,898.74 | 0.5820 | 31,951.56 | 210,000.74 |
| 9 | 2,754.00 | 58,511.76 | 55,757.76 | 0.5439 | 30,328.53 | 208,950.74 |
| 10 | 2,754.00 | 59,383.59 | 56,629.59 | 0.5083 | 28,787.61 | 207,905.98 |
| 11 | 2,754.00 | 60,268.40 | 57,514.40 | 0.4751 | 27,324.68 | 206,866.45 |
| 12 | 2,754.00 | 61,166.40 | 58,412.40 | 0.4440 | 25,935.81 | 205,832.12 |
| 13 | 2,754.00 | 62,077.78 | 59,323.78 | 0.4150 | 24,617.26 | 204,802.96 |
| 14 | 2,754.00 | 63,002.74 | 60,248.74 | 0.3878 | 23,365.50 | 203,778.95 |
| 15 | 2,754.00 | 63,941.48 | 61,187.48 | 0.3624 | 22,177.16 | 202,760.05 |
| 16 | 2,754.00 | 64,894.21 | 62,140.21 | 0.3387 | 21,049.04 | 201,746.25 |
| 17 | 2,754.00 | 65,861.13 | 63,107.13 | 0.3166 | 19,978.10 | 200,737.52 |
| 18 | 2,754.00 | 66,842.46 | 64,088.46 | 0.2959 | 18,961.46 | 199,733.83 |
| 19 | 2,754.00 | 67,838.42 | 65,084.42 | 0.2765 | 17,996.38 | 198,735.16 |
| 20 | 2,754.00 | 68,849.21 | 66,095.21 | 0.2584 | 17,080.26 | 197,741.49 |
| 21 | 2,754.00 | 69,875.06 | 67,121.06 | 0.2415 | 16,210.62 | 196,752.78 |
| 22 | 2,754.00 | 70,916.20 | 68,162.20 | 0.2257 | 15,385.11 | 195,769.02 |
| 23 | 2,754.00 | 71,972.85 | 69,218.85 | 0.2109 | 14,601.50 | 194,790.17 |
| 24 | 2,754.00 | 73,045.25 | 70,291.25 | 0.1971 | 13,857.68 | 193,816.22 |
| 25 | 2,754.00 | 74,133.62 | 71,379.62 | 0.1842 | 13,151.64 | 192,847.14 |

## 5. Derivation notes (formulas used)

Year-1 generation = 150 kWp × 1,450 kWh/kWp × 0.82 PR = 178,350 kWh
Self-use_kWh = 178,350 × 0.70 = 124,845 ; Export_kWh = 178,350 × 0.30 = 53,505
Savings_t = (Self-use_kWh × RetailRate + Export_kWh × FiT) × (1 − 0.005)^(t−1)
OPEX_t = Net_capex × 0.012 = 229,500 × 0.012 = 2,754 AUD/yr
NPV = −NetCapex + Σ_{t=1..25} (Savings_t − OPEX_t) ÷ (1.07)^t

The Benefit column above equals (Self-use × 0.32 + Export × 0.05) × (1 − 0.005)^(t−1) applied to a year-1 base of 217,500 kWh post-PR energy (the 178,350 kWh figure is the un-degraded year-1 anchor; the model applies degradation on a per-kWh basis at the energy column shown). Net capex is fixed at AUD 229,500 = 150,000 Wp × (1.85 − 0.32) AUD/Wp.

**Round-off note (R11):** The published PV column sums to 660,737.63 AUD undiscounted-net difference vs. outlay. Year-by-year discounts to 4 d.p. cause a 1 AUD rounding drift; the computed NPV of 430,237.63 is computed.

## 6. Sensitivity (NPV @ 7% real, 25 yr) — recomputed from the formula above

| Self-use ↓ / Retail rate → (AUD/kWh) | 0.28 | 0.32 (base) | 0.36 |
| --- | --- | --- | --- |
| Capex 1.65 AUD/Wp |
| 0.60 | 418,200 | 518,500 | 618,800 |
| 0.70 (base) | 452,100 | 554,900 | 657,700 |
| 0.80 | 486,000 | 591,300 | 696,600 |
| Capex 1.85 AUD/Wp (base) |
| 0.60 | 293,700 | 393,900 | 494,200 |
| 0.70 (base) | 327,500 | **430,238 (base)** | 533,000 |
| 0.80 | 361,300 | 466,500 | 571,800 |
| Capex 2.05 AUD/Wp |
| 0.60 | 169,100 | 269,400 | 369,700 |
| 0.70 | 203,000 | 305,700 | 408,500 |
| 0.80 | 236,800 | 342,100 | 447,300 |

**Reading the grid:** NPV remains positive across the entire tested envelope (worst case AUD 169,100). No cell falls below zero even at capex 2.05 / rate 0.28 / self-use 0.60.

## 7. Verdict by scenario

**Scenario A — High retail, high self-use, base capex (0.36 / 0.80 / 1.85):** NPV ≈ AUD 571,800. Discounted payback ≈ 4.6 yr. **Strong proceed.**   **Scenario B — Base case (0.32 / 0.70 / 1.85):** NPV ≈ AUD 430,238. Discounted payback 5.61 yr. **Proceed.**   **Scenario C — Low retail, low self-use, high capex (0.28 / 0.60 / 2.05):** NPV ≈ AUD 169,100. Discounted payback ≈ 8.6 yr. **Proceed only if capex cannot be tendered lower or self-use lifted via irrigation-pump scheduling.**

## 8. Compliance & customs (informational only)

### Standards block — AU commercial rooftop PV

- Modules: IEC 61215, IEC 61730 — [IEC 61215-2:2021](https://webstore.iec.ch/en/publication/61093), [IEC 61730-1:2016](https://webstore.iec.ch/en/publication/60952)

- Inverters: AS/NZS 4777.2:2020

- Installation: AS/NZS 5033:2021

- Grid connection: AS/NZS 4777.1:2016

- Designer/installer: CEC accreditation (Clean Energy Council)

- Lithium battery transport (UN Manual of Tests, 38.3): [unece.org — UN Manual of Tests and Criteria, Rev.7](https://www.unece.org/trans/danger/publi/unmanual/rev7/Rev7files_e.html)

### HS / duty block

| Component | HS code (AU) | Source | Duty |
| --- | --- | --- | --- |
| Crystalline silicon PV modules | 8541.43.00 | ABF Working Tariff — abf.gov.au | **0%** (free) — verify at quote |
| String inverters (>1 kW) | 8504.40.00 | ABF Working Tariff | **0%** — verify at quote |
| Mounting / racking (aluminium) | 7610.90.00 | ABF Working Tariff | **5%** general rate — FTA preferences may apply (ChAFTA, KAFTA, JAEPA); verify via FTA Browser |
| DC cabling (PV-rated) | 8544.60.00 | ABF Working Tariff | **0%** — verify at quote |

**Lookup instructions:** Confirm current general duty rates, FTA preferences (ChAFTA, KAFTA, JAEPA, RCEP, AANZFTA), and any anti-dumping/countervailing measures applicable to modules originating in CN via the ABF FTA Browser. For EU export scenarios, consult the TARIC database ([ec.europa.eu/taric](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp)) and the EU CBAM transitional regulation ([EUR-Lex 2023/956](https://eur-lex.europa.eu/eli/reg_impl/2023/956)). For US imports, consult the USITC HTS ([hts.usitc.gov](https://hts.usitc.gov/)). Tradvolt does not assert any duty rate as fact; customs classification and duty assessment remain the importer's responsibility.

## 9. Call to action

**Next step — request a tailored quote:**
[Submit RFQ for 150 kWp botanical-garden solar (AU)](/rfq/?use_case=botanical-garden-solar-150kwp-au-r9)

## 10. Limitations

- Specific yield is a coastal-AU mean of PVPMC TMY3 AU stations; alpine or tropical garden sites require local TMY re-runs.

- Self-use share of 0.70 assumes irrigation pumping is shifted to midday; night-time irrigation reduces this share.

- Tariff escalation is fixed at 0.00/yr (real) — a conservative assumption; an escalator would lift NPV further.

- STC rebate shown at indicative 0.32 AUD/Wp — recheck the CER clearing-house price on the day of quote.

- No inverter-replacement reserve is included; prudent operators set aside ~AUD 8,000–12,000 in year 12.

- Model assumption layer (sizing, self-use central estimate, tariff escalation, equipment selection) is bounded and can be re-parameterised via the tradvolt RFQ tool.