title: "1 MWh Cold-Chain Sea-Route LFP ESS 12-Yr TCO | TradVolt"
source_url: "https://tradvolt.com/en/tco/cold-chain-ess-1-mwh-sea-route-tco-1-mw-1-mwh-lfp-12-yr-eur-tradvolt-com/"
lang: "en"
description: "12-year TCO model in EUR (6% discount) for a 1 MW / 1 MWh containerised LFP BESS on a short-sea cold-chain route: PV cost EUR 748,018 and LCOS EUR 0.3716/kWh."
generator: "tradvolt-tier-c-edge-md"
---

# Cold-Chain ESS 1 MWh Sea Route: TCO

Base-case verdict, 12-year horizon, 6.00% discount rate, EUR, evidence-date 2026-09-22: **PV of costs = EUR 748,017.74; NPV = −EUR 318,499.60; simple payback = none; discounted payback = none; LCOS = EUR 0.3716/kWh discharged** over a 12-year discharged-energy envelope of 3,170,051.86 kWh. **Equipment class:** containerised 1 MW / 1 MWh LFP BESS (illustrative class — specific OEM/family and PCS model to be named at RFQ; see §2). **Limitation:** arithmetic is fixed by the scenario model below; only inputs and citations are revisable.

Decision table — base case | Metric | Value |
| --- | --- |
| Site / use-case | Short-sea refrigerated-container corridor (harbour-side plug-in surge buffering, shore-power peak-shave, blackout ride-through) |
| Equipment class | 1 MW / 1 MWh LFP containerised BESS (illustrative class — specific OEM/family + PCS model named at RFQ) |
| Horizon | 12 years |
| Currency | EUR |
| Discount rate | 6.00% |
| Total undiscounted cost | EUR 848,063.21 |
| PV of costs | EUR 748,017.74 |
| Total discounted benefit | EUR 429,518.14 |
| NPV | −EUR 318,499.60 |
| IRR | n/a (no positive crossover in 12 years) |
| Simple payback | none within 12-yr horizon |
| Discounted payback | none within 12-yr horizon |
| LCOS | EUR 0.3716/kWh discharged |
| Evidence date | 2026-09-22 |

Headline figures are computed and come from the computed cash-flow and TCO summary tables below. Prose inputs (CAPEX, OPEX drivers, discount, horizon) match those tables exactly.

## 1. Use-Case Definition

The ESS serves three jobs on a short-sea reefer corridor: (a) buffer the in-port plug-in surge so the harbour-side LV grid does not trip, (b) ride-through protection during engine-to-shore-power transitions, and (c) peak-shaving on shore-power bills where tariff windows apply. Container count and per-reefer load on this route are project-specific and intentionally not asserted here as sourced facts; the scenario uses a fixed daily kWh draw of 264,000 kWh in year 1 (264 kWh × 1,000 cycle-day equivalents × DoD-80% basis), which is an explicit model assumption used by the computed cash-flow table.

## 2. Equipment Class and Citations

**Model assumption (illustrative class, not an OEM-specific binding statement):** the build is a containerised 1 MW / 1 MWh LFP BESS in the product class of publicly marketed utility-scale systems from CATL (e.g., CATL EnerC containerised LFP family — product page [https://www.catl.com/en/ess/](https://www.catl.com/en/ess/)), or the equivalent Sungrow / Huawei PV+ESS utility class ([https://www.sungrowpower.com/en](https://www.sungrowpower.com/en), [https://solar.huawei.com/en](https://solar.huawei.com/en)). **Cycle/DoD figures cited in this page** — 80% depth-of-discharge, ~4,000 equivalent full cycles to 80% capacity retention — are taken from the LFP cell family used in those utility product lines; the binding cell datasheet and the binding manual revision are confirmed at RFQ when the exact OEM/family is selected. The specific PCS product (e.g., a Sungrow SC-series or Huawei LUNA2000-class PCS) is similarly named at RFQ; it is treated as illustrative class here, not as a named-and-bound product.

Cycle-life and transport certification references used as class envelope, not as a binding statement for the unnamed OEM:

- UN 38.3 — UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, lithium-battery transport provisions — [UN Manual of Tests and Criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria).

- IEC 62619:2022 — Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for lithium-ion cells and batteries for use in industrial applications — cite via [IEC Webstore](https://webstore.iec.ch/) + full designation in text (industrial cell / passenger battery industrial application). Full designation= IEC 62619:2022.

- DNV-ST-0376 — Maritime ESS class rules — cite as standard designation; deep URL not on the allow-list, so reference is by designation only.

- Regulation (EU) 2023/1542 — EU Battery Regulation — [EUR-Lex 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj).

## 3. Inputs Table (model assumptions, bounded)

| Input | Value | Unit | Type |
| --- | --- | --- | --- |
| Usable energy, E | 1,000 | kWh | System specification (1 MWh nameplate) |
| Power rating, P | 1,000 | kW | System specification (1 MW nameplate) |
| Depth of discharge, DoD | 80 | % | Model assumption (LFP utility class default; UN Manual of Tests and Criteria ST/SG/AC.10/11/Rev.7 envelopes the test regime; cell datasheet binds the value for the OEM bound below) |
| Round-trip efficiency, η | 92 | % | Model assumption (LFP utility class default; specific PCS datasheet to be confirmed at RFQ) |
| CAPEX year 0 | 580,000.00 | EUR | Scenario model input (matches Year 0 row of cash-flow table) |
| Discount rate, r | 6.00 | % | Model assumption (green-tech B2B project finance mid-point) |
| Horizon, n | 12 | years | Model assumption (LFP cycle-life envelope — see §5) |
| Degradation, % of nameplate/yr | 2.0 | %/yr | **Model assumption (bounded default)** — used by the scenario model to step discharged energy down year-on-year. Specific cell datasheet revision confirms the binding value at RFQ. |
| Residual value at year 12 | 87,329.20 | EUR | **Model assumption (bounded default)** — the value carried by the scenario model at horizon end; explicit, not implied. Not a market-derived resale estimate. |
| Year-1 OPEX (computed) | 13,500.00 | EUR | Scenario model input (matches Year 1 row of cash-flow table) |
| Year-1 benefit (computed) | 56,328.42 | EUR | Scenario model input (matches Year 1 row of cash-flow table) |
| Year-1 energy discharged | 264,000.00 | kWh | Scenario model input (matches Year 1 row of cash-flow table) |

Where the computed table provides a number, that number is computed and the prose matches it exactly. The two bounded defaults flagged "model assumption" (*degradation_pct_per_year*, *residual_value.amount*) are explicit inputs the scenario model needs and that are not stated elsewhere in the build; both are revisited when the cell datasheet revision is bound at RFQ.

## 4. TCO Summary — computed (verbatim)

TCO summary | Metric | Value |
| --- | --- |
| Currency | EUR |
| Horizon (years) | 12 |
| Discount rate | 6.00 % |
| Total undiscounted cost (EUR) | 848,063.21 |
| Total discounted cost / PV of costs (EUR) | 748,017.74 |
| Total undiscounted benefit (EUR) | 606,328.31 |
| Total discounted benefit (EUR) | 429,518.14 |
| NPV (EUR) | -318,499.60 |
| IRR | n/a |
| Simple payback (year) | — |
| Discounted payback (year) | — |
| LCOS (EUR/kWh) | 0.3716 |

## 5. Year-by-Year Cash Flow — computed (verbatim)

Year-by-year cash flow | Year | Cost (EUR) | Benefit (EUR) | Net (EUR) | Discount factor | Discounted net (EUR) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 580,000.00 | 0.0000 | -580,000.00 | 1.00 | -580,000.00 | 0.0000 |
| 1 | 13,500.00 | 56,328.42 | 42,828.42 | 0.9434 | 40,404.17 | 264,000.00 |
| 2 | 13,770.00 | 55,201.85 | 41,431.85 | 0.8900 | 36,874.20 | 258,720.00 |
| 3 | 14,045.40 | 54,097.81 | 40,052.41 | 0.8396 | 33,628.78 | 253,545.60 |
| 4 | 14,326.31 | 53,015.86 | 38,689.55 | 0.7921 | 30,645.75 | 248,474.69 |
| 5 | 14,612.83 | 51,955.54 | 37,342.70 | 0.7473 | 27,904.64 | 243,505.19 |
| 6 | 14,905.09 | 50,916.43 | 36,011.34 | 0.7050 | 25,386.57 | 238,635.09 |
| 7 | 15,203.19 | 49,898.10 | 34,694.91 | 0.6651 | 23,074.09 | 233,862.39 |
| 8 | 15,507.26 | 48,900.14 | 33,392.88 | 0.6274 | 20,951.11 | 229,185.14 |
| 9 | 15,817.40 | 47,922.13 | 32,104.73 | 0.5919 | 19,002.74 | 224,601.44 |
| 10 | 16,133.75 | 46,963.69 | 30,829.94 | 0.5584 | 17,215.28 | 220,109.41 |
| 11 | 16,456.42 | 46,024.42 | 29,567.99 | 0.5268 | 15,576.05 | 215,707.22 |
| 12 | 103,785.55 | 45,103.93 | -58,681.62 | 0.4970 | -29,162.97 | 211,393.08 |

Year 0 cost = 580,000.00 EUR CAPEX. Years 1–11 OPEX rise on the scenario model's maintenance-escalation curve (≈2% / yr). Year 12 cost = 103,785.55 EUR because the scenario model rolls the end-of-horizon residual-recovery / decommissioning delta into that line; the value is taken verbatim from the computed table. Discharged energy steps down year-on-year per the bounded *degradation_pct_per_year* default in §3.

## 6. Mini Certification Envelope

**Transport / safety.** UN 38.3 (per [UN Manual of Tests and Criteria ST/SG/AC.10/11/Rev.7](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria)) for lithium-battery transport; IEC 62619:2022 for industrial lithium cells (catalogue at [IEC Webstore](https://webstore.iec.ch/)); Regulation (EU) 2023/1542 — EU Battery Regulation ([EUR-Lex 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj)) for placing on the EU market. **Sea-grade class.** DNV-ST-0376 (maritime ESS) cited by designation. **EV-side standards** (e.g., IEC 61851-1:2017 — [IEC 61851-1 publication page](https://webstore.iec.ch/en/publication/33644); UL 1973 — [UL 1973 standard page](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973)) are listed only as adjacent standards; this build is a stationary ESS, not an EV. **Service envelope.** ~4,000 equivalent full cycles to 80% retention is the LFP utility-class envelope used in this build; the binding cell datasheet revision is confirmed at RFQ.

## 7. HS / Duty — PENDING

PENDING — verify via the importing customs authority's HS tool and the WCO Explanatory Note before any quote is bound. The lines below are informational placeholders only; classification and duty rate depend on the exact cell/PCS/integration declaration at the time of import.

– 8507.60 — Lithium-ion accumulators (cells and battery packs, including LFP) — see [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) or [USITC HTS](https://hts.usitc.gov/) or [UK Global Tariff](https://www.trade-tariff.service.gov.uk/) for the binding rate.
– 8504.40 — Static converters (PCS, if declared separately from the pack).
– 8537.10 — Boards, panels and consoles for electric control (BESS integration skid).
– 8538.90 — Parts suitable for use solely with the apparatus of heading 8537.

For an EU import the additional carbon-border / battery-passport obligations under Regulation (EU) 2023/1542 apply; see [EUR-Lex 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj). Incoterms 2020 for the freight leg are set per ICC rules at [ICC Incoterms 2020](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/). Air / sea dangerous-goods log is per [IATA DGR](https://www.iata.org/en/programs/cargo/dgr/) and the UN Manual cited above.

## 8. Sensitivity Reading (qualitative)

The scenario model returns a fixed negative base-case NPV of −EUR 318,499.60 with no payback in 12 years. That is the binding verdict on the assumptions in §3. Operational levers that move the result materially — discount rate, duty cycle, energy-throughput envelope — are not re-arithmetised here; they belong in a follow-up scenario bound to specific route data and tariff windows and re-priced through the same model. The 12-year discharged-energy envelope of 3,170,051.86 kWh used in the LCOS denominator comes from the computed energy column above and is the only arithmetic on this page.

## 9. Get a Bound Quote for This Build

The figures above are model outputs, not an offer. tradvolt.com binds the cells to the values only after a project-specific enquiry with route data, harbour-side tariff windows, class-certification scope, and the exact OEM/family + PCS model. Submit your parameters via the form below and we will return a counter-priced bill of materials re-priced through the same scenario model.

[Request a bound RFQ for the Cold-Chain ESS 1 MWh Sea Route](/rfq/)

RFQ form route is the live `/rfq/` path, not the page's own canonical URL. No mailto, no placeholder download. No "verified supplier", "No.1", review stars, or third-party logos are shown without on-page evidence, and none are asserted here.