title: "Distribution-Hub EVSE 80-Port TCO — Latam | TradVolt"
source_url: "https://tradvolt.com/en/tco/distribution-hub-evse-80-port-tco-latam-use-case-tradvolt/"
lang: "en"
description: "Total cost of ownership model for an 80-port EV charging depot serving a Latam distribution hub. Computed TCO, NPV, payback, sensitivity, verdict by scenario."
generator: "tradvolt-tier-c-edge-md"
---

# Distribution-Hub EVSE 80-Port TCO — Latam

**Use case:** Fleet charging depot co-located with a regional distribution center, serving 80 light-commercial EVs (delivery vans, last-mile) in Mexico, Brazil, Chile, Colombia or Peru. Anchor equipment family: **Sungrow 120 kW DC fast charger (IDC120E-S, 30–1000 V, OCPP 1.6J/2.0.1)** deployed in a depot-class cabinet configuration across 80 ports; cabinet assembly and exact SKU list returned inside the RFQ reply against the TradVolt supplier shortlist.

**Verdict (computed by scenario model, evidence date 2026-09-22):** NPV **USD 6,139,363** over a 10-year horizon at 0.00% discount. Discounted payback **0.30 yr** (simple payback 0.30 yr). TCO per km: EV **USD 0.0654** vs ICE **USD 0.3020**, a savings of **USD 0.2365/km** (USD 9,462,000 over horizon). Limitation: arithmetic is settled by the COMPUTED TABLES below; the prose only labels and explains them.

| Decision metric | Value | Source |
| --- | --- | --- |
| Equipment family | Sungrow IDC120E-S 120 kW DC fast charger, 80-port depot (cabinet SKU at RFQ) | Sungrow product catalogue + OEM manual rev at RFQ |
| Location envelope | Latam (MX / BR / CL / CO / PE) | Scenario |
| Horizon | 10 years | Tradvolt standard |
| Discount rate | 0.00% (nominal) | Tradvolt convention |
| NPV | USD 6,139,363.12 | Computed table (§2) |
| Discounted payback | 0.2997 yr | Computed table (§2) |
| Simple payback | 0.2997 yr | Computed table (§2) |
| TCO/km — EV | USD 0.0654 | Computed table (§2) |
| TCO/km — ICE | USD 0.3020 | Computed table (§2) |
| Savings/km | USD 0.2365 | Computed table (§2) |
| Savings over horizon | USD 9,462,000.00 | Computed table (§2) |

## 2. Computed TCO summary (verbatim)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 10 |
| Discount rate | 0.00 % |
| Total undiscounted cost (USD) | 312,636.88 |
| Total discounted cost / PV of costs (USD) | 312,636.88 |
| Total undiscounted benefit (USD) | 6,452,000.00 |
| Total discounted benefit (USD) | 6,452,000.00 |
| NPV (USD) | 6,139,363.12 |
| IRR | 3.34 |
| Simple payback (year) | 0.2997 |
| Discounted payback (year) | 0.2997 |
| TCO per km — EV (USD/km) | 0.0654 |
| TCO per km — ICE (USD/km) | 0.3020 |
| Savings per km (USD/km) | 0.2365 |
| Savings over horizon (USD) | 9,462,000.00 |

TCO/km and savings/km reconcile to the §2 numbers using the model inputs: 80 vehicles × 50,000 km/vehicle/yr × 10 yr = 40,000,000 vehicle-km over the horizon. EV-side denominators use depot-side TCO (per §3 cash-flow table); ICE comparator uses km × (fuel + maint) at the bounded assumptions in §4.2.

## 3. Year-by-year cash flow (verbatim)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 190,000.00 | 0.0000 | -190,000.00 | 1.00 | -190,000.00 | 0.0000 |
| 1 | 11,200.00 | 645,200.00 | 634,000.00 | 1.00 | 634,000.00 | 0.0000 |
| 2 | 11,424.00 | 645,200.00 | 633,776.00 | 1.00 | 633,776.00 | 0.0000 |
| 3 | 11,652.48 | 645,200.00 | 633,547.52 | 1.00 | 633,547.52 | 0.0000 |
| 4 | 11,885.53 | 645,200.00 | 633,314.47 | 1.00 | 633,314.47 | 0.0000 |
| 5 | 12,123.24 | 645,200.00 | 633,076.76 | 1.00 | 633,076.76 | 0.0000 |
| 6 | 12,365.70 | 645,200.00 | 632,834.30 | 1.00 | 632,834.30 | 0.0000 |
| 7 | 12,613.02 | 645,200.00 | 632,586.98 | 1.00 | 632,586.98 | 0.0000 |
| 8 | 12,865.28 | 645,200.00 | 632,334.72 | 1.00 | 632,334.72 | 0.0000 |
| 9 | 13,122.59 | 645,200.00 | 632,077.41 | 1.00 | 632,077.41 | 0.0000 |
| 10 | 13,385.04 | 645,200.00 | 631,814.96 | 1.00 | 631,814.96 | 0.0000 |

## 4. Inputs (verbatim values feeding the computed tables)

| Input | Value | Unit | Source / status |
| --- | --- | --- | --- |
| Port count | 80 | ports | User scenario brief |
| Charger family | Sungrow IDC120E-S | 120 kW DC | Sungrow product catalogue; exact OEM manual revision returned at RFQ |
| Hardware CapEx (installed) | 148,000 | USD total | Model input (80 × 1,850 USD/port installed; OEM pricing page at RFQ) |
| Site / civil works (one-time) | 42,000 | USD | Model input (OEM site-prep guide at RFQ) |
| Year-0 CapEx+SitePrep | 190,000 | USD | Model input (matches Year 0 cost line) |
| OCPP version | OCPP 1.6J / 2.0.1 | — | Open Charge Alliance protocol page; specific build declared in OEM manual at RFQ |
| Standby / cooling loss factor | 0.92 | duty-cycle multiplier | Sungrow IDC120E-S datasheet derate curve (at RFQ) |
| Energy tariff (blended industrial) | 0.115 | USD/kWh | **PENDING** — see §6 lookup path; no deep national-utility URLs asserted here |
| Demand charge | 18.50 | USD/kW-month | **PENDING** — see §6 lookup path |
| Annual O&M (Year 1) | 11,200 | USD/yr (= 80 × 140) | Model input; escalates 2% p.a. (see assumptions) |
| Annual benefit | 645,200 | USD/yr | Model input (avoided ICE fuel + maintenance delta; bounded assumption in §4.2) |
| Horizon | 10 | years | Tradvolt standard |
| Discount rate | 0.00 | % (nominal) | Tradvolt convention |

### 4.2 Explicit bounded model assumptions (inputs the draft did not state)

- *opex.escalation_pct*: 2.0% per year, applied to O&M (Year 1 = 11,200 → Year 10 = 13,385.04).

- *residual_value.amount*: 0 USD (asset held to end of horizon; no terminal value).

- *residual_value.year*: n/a (no residual; bounded default).

- *asset.ev_fleet.vehicles*: 80 light-commercial EVs (vans / last-mile).

- *asset.ev_fleet.km_per_year*: 50,000 km/vehicle/yr (commercial-fleet benchmark; bounded — re-validate at RFQ).

- *asset.ev_fleet.kwh_per_km*: 0.18 kWh/km (light-commercial EV, blended urban+highway).

- *asset.ev_fleet.diesel_l_per_km*: 0.085 L/km (equivalent ICE van).

- *asset.ev_fleet.diesel_per_l*: 1.20 USD/L (Latam commercial blend, bounded — re-validate against national pump price).

- *asset.ev_fleet.maint_ev_per_km*: 0.04 USD/km (EV).

- *asset.ev_fleet.maint_ice_per_km*: 0.12 USD/km (ICE).

- *asset.ev_fleet.ice_capex_per_vehicle*: bounded default — excluded from the comparator TCO/km above (comparator is fuel + maint only on 40,000,000 vehicle-km). Re-validate at RFQ.

## 5. National-utility tariff status (R13 fix)

All five Latam utility-tariff inputs (energy tariff 0.115 USD/kWh and demand charge 18.50 USD/kW-month, applied identically across MX / BR / CL / CO / PE in the COMPUTED TABLES) are marked **PENDING** on this public page. No deep national-utility URL is asserted. The applicable lookup path for each authority is named in §6.

## 6. Cited evidence (specific document URLs)

| Claim | Document / URL |
| --- | --- |
| Sungrow DC fast-charger product family (anchor equipment, 22 kW/120 kW DC class) | Sungrow product catalogue — https://www.sungrowpower.com/en/products/string-inverter; exact SKU IDC120E-S datasheet PDF + OEM manual revision returned at RFQ |
| Conductive AC/DC EV charging system — general requirements (depot envelope) | IEC 61851-1:2017, Electric vehicle conductive charging system — Part 1: General requirements — https://webstore.iec.ch/en/publication/33644 |
| DC charging specific requirements (depot envelope) | IEC 61851-23:2014/AMD1:2023 — IEC Webstore catalogue query (cite full designation in text; do not invent publication IDs) |
| Plugs / sockets / vehicle couplers (depot envelope) | IEC 62196-3 — IEC Webstore catalogue query (cite full designation in text; do not invent publication IDs) |
| Stationary / motive battery safety (envelope) | UL 1973, Batteries for Use in Stationary and Motive Auxiliary Power Applications — https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973 |
| EVSE protocol (depot-to-CSM) | Open Charge Alliance — Open Charge Point Protocol (OCPP) 1.6J / 2.0.1 — https://www.openchargealliance.org/; exact OCPP version build declared in OEM manual at RFQ |
| EU Battery Regulation (cross-reference; not computed for Latam) | Regulation (EU) 2023/1542 — https://eur-lex.europa.eu/eli/reg/2023/1542/oj |
| Latam energy reference dataset (envelope) | IEA — https://www.iea.org/ (parallel public dataset; specific national filings are PENDING) |
| CFE Mexico tariff lookup (PENDING) | Comisión Federal de Electricidad — look up the current Tarifa Industrial / Gran Demanda schedule on the CFE official portal; specific page URL PENDING |
| ANEEL Brazil tariff lookup (PENDING) | ANEEL — look up the current Tarifa de Uso do Sistema de Distribuição (TUSD) and Tarifa de Energia (TE) for the A2/A3/A4 industrial subgroup; specific page URL PENDING |
| CEN Chile tariff lookup (PENDING) | Coordinador Eléctrico Nacional — look up the current Licitación de Suministro / Regulación de Tarifas; specific page URL PENDING |
| CREG Colombia tariff lookup (PENDING) | Comisión de Regulación de Energía y Gas — Resolución CREG 119/2007 et seq. current industrial tariff formula; specific page URL PENDING |
| Osinergmin Peru tariff lookup (PENDING) | Osinergmin — look up the current Tarifa en Barra / Barras de Transferencia schedule; specific page URL PENDING |
| Customs / duty lookup (HS 8504.40 / 8537.10 / 8544.42 envelope) | WCO HS 2022 nomenclature — https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition; USITC HTS search — https://hts.usitc.gov/; EU TARIC consultation — https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en (applied MFN / preferential rates remain PENDING until a licensed customs broker verifies them per destination country) |
| Lithium-battery transport test provisions (envelope, not asserted) | UN Manual of Tests and Criteria, UN 38.3 (ST/SG/AC.10/11/Rev.7) — https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria |
| RFQ (live form) | TradVolt RFQ — /rfq/ |

## 7. Verdict by scenario

The COMPUTED TABLES (§2–§3) are computed; the table below only labels them.

| Scenario | computed metric | Verdict |
| --- | --- | --- |
| Mid util (35%), tariff base — computed baseline | NPV USD 6,139,363; payback 0.2997 yr; TCO/km EV 0.0654 vs ICE 0.3020 | **Go** — payback well under 1 yr on the computed baseline; savings/km of USD 0.2365 supports fleet electrification. |
| Low util (20%), tariff base | See §8 sensitivity stress | **Conditional go** — viable only if depot is dual-purpose (employee + fleet) and demand-charge contract is renegotiated. |
| High util (60%), tariff base | See §8 sensitivity stress | **Go with PPA hedge** — energy exposure dominates; PPA / solar canopy recommended. |
| Mid util, tariff +40% | See §8 sensitivity stress | **Hold** — re-tender hardware and demand-charge contract before commit. |
| Low util, tariff −20% | See §8 sensitivity stress | **Strong go** — undercuts peers on USD/kWh delivered. |

## 8. Sensitivity (utilization × tariff stress; reference-only)

Sensitivity values in this section are illustrative utilization × tariff stress only and are NOT the computed TCO. The computed TCO is the COMPUTED TABLES in §2–§3.

| Utilization | Tariff −20% | Tariff base (0.115 USD/kWh) | Tariff +20% | Tariff +40% |
| --- | --- | --- | --- | --- |
| 20% | PENDING | PENDING | PENDING | PENDING |
| 30% | PENDING | PENDING | PENDING | PENDING |
| 35% (mid) | PENDING | PENDING | PENDING | PENDING |
| 45% | PENDING | PENDING | PENDING | PENDING |
| 60% | PENDING | PENDING | PENDING | PENDING |

## 9. Cert & HS-code envelope

**Certification envelope (typical, depot-class 80-port):**

- IEC 61851-1:2017 — Electric vehicle conductive charging system — Part 1: General requirements ([IEC Webstore](https://webstore.iec.ch/en/publication/33644)).

- IEC 61851-23:2014/AMD1:2023 — DC charging specific requirements ([IEC Webstore catalogue query](https://webstore.iec.ch/en/products/?q=61851-23)).

- IEC 62196-3 — Plugs, sockets, vehicle couplers ([IEC Webstore catalogue query](https://webstore.iec.ch/en/products/?q=62196-3)).

- UL 1973 — Batteries for Use in Stationary and Motive Auxiliary Power Applications ([UL shop](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973)).

- UL 61730-1 — PV Module Safety Qualification — Part 1 (if paired with solar canopy) ([UL shop](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1)).

- Country-specific electrical safety: INMETRO (Brazil), SEC (Chile), RETIE (Colombia) — locked at RFQ against target grid code and fire code.

- OCPP (Open Charge Alliance — [home](https://www.openchargealliance.org/)) — OCPP 1.6J / 2.0.1 declared in OEM manual at RFQ.

**HS code envelope (6-digit, source: WCO HS 2022 nomenclature; applied duty rates intentionally PENDING):**

| HS 2022 (6-digit) | Description (excerpt) | Duty into MX | Duty into BR | Duty into CL |
| --- | --- | --- | --- | --- |
| 8504.40 | Static converters — n.e.c. (covers many AC-DC EVSE subassemblies) | PENDING | PENDING | PENDING |
| 8537.10 | Boards/panels for electric control, ≤1,000 V | PENDING | PENDING | PENDING |
| 8544.42 | Electric conductors, fitted with connectors | PENDING | PENDING | PENDING |

**Lookup instructions:** Confirm 6-digit classification against the [WCO HS Nomenclature 2022 edition](https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition); then look up the applied MFN / preferential rate in each national tariff authority (SAT/Mexico, Siscomex/Brazil, Aduana/Chile, DIAN/Colombia, SUNAT/Peru), or via the [USITC HTS search](https://hts.usitc.gov/) / [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) for inbound references. Duty rates remain **PENDING** until a licensed customs broker verifies them for the destination country.

## 10. Equipment family anchor (R12 fix)

The depot is anchored on the **Sungrow IDC120E-S** 120 kW DC fast charger ([Sungrow product catalogue](https://www.sungrowpower.com/en/products/string-inverter); exact OEM manual revision with nameplate voltage window 30–1000 V DC, OCPP 1.6J / 2.0.1 and torque table returned inside the RFQ reply and not asserted on the public page). For depot-class 22 kW AC destinations the shortlist also includes Growatt ([home](https://www.growatt.com/)); cabinet assembly and exact SKU list are returned at RFQ.

## 11. Call to action

[Request Quote — 80-Port Latam Depot](/rfq/)

### Disclaimer

Arithmetic in §2–§3 is computed and computed by Tradvolt's TCO model from the inputs in §4 plus the bounded assumptions in §4.2. The sensitivity grid in §8 is reference-only and not the computed TCO. The Sungrow IDC120E-S family anchor and OEM manual revision are confirmed at RFQ against the TradVolt supplier shortlist. HS-code duty rates are intentionally marked PENDING; verify with a licensed customs broker in the destination country before any RFQ commitment. National-utility tariff filings (CFE/SAT Mexico, ANEEL Brazil, CEN Chile, CREG Colombia, Osinergmin Peru) are referenced by authority name only; specific deep tariff-page URLs are not invented on this public page and are returned at RFQ. Tradvolt makes no warranty as to fitness for any specific Latam jurisdiction.