# Distribution-Hub EVSE 80-Port — TCO for MEA

**Verdict (use case: 80-port EVSE hub at a Middle East & Africa distribution centre, 10-year horizon, 9.00% discount rate, evidence date 2026-09-22).** The hub is finance-positive on a discounted-cash basis. computed figures from the scenario model: NPV = **USD 692,295.05**; IRR = **22.06%**; simple payback = **3.86 years**; discounted payback = **4.97 years**; PV of costs = **USD 2,002,222.72**; PV of benefits = **USD 2,694,517.76**; TCO per km — EV = **USD 0.1093**; TCO per km — ICE = **USD 0.3340**; savings per km = **USD 0.2247**; savings over horizon = **USD 6,291,800.00**. Limitation: this is a depot-charging TCO for AC 22 kW + DC 60 kW hardware only; vehicle unit economics and battery degradation are not modelled here and must be recomputed at RFQ stage.

Decision summary | Metric | Value | Time basis |
| --- | --- | --- |
| Recommendation | PROCEED | — |
| NPV | USD 692,295.05 | Discounted, 10 yr |
| IRR | 22.06% | 10 yr |
| Simple payback | 3.86 yr | Undiscounted |
| Discounted payback | 4.97 yr | Discounted @ 9.00% |
| TCO per km (EV) | USD 0.1093 | Discounted 10 yr |
| TCO per km (ICE) | USD 0.3340 | Discounted 10 yr |
| Savings per km | USD 0.2247 | Discounted 10 yr |
| PV of total cost | USD 2,002,222.72 | Discounted |
| PV of total benefit | USD 2,694,517.76 | Discounted |

Base case equipment: *AC* — Huawei FusionSolar Smart Charger SCharger-22KT-S1 (22 kW, three-phase, OCPP 1.6/2.0.1, IEC 61851-1 compliant; see OEM product page at [https://solar.huawei.com/en](https://solar.huawei.com/en) and IEC 61851-1:2017 at [https://webstore.iec.ch/en/publication/33644](https://webstore.iec.ch/en/publication/33644)). *DC* — Growatt TH-S 60K-T2 (60 kW DC fast charger, OCPP 1.6, IEC 61851-1 compliant; OEM landing at [https://www.growatt.com/](https://www.growatt.com/)). Hardware pricing used in the scenario model: USD 3,800 per AC port and USD 28,500 per DC port (model assumption for 2024 MEA landed cost, including installation).

## 1. Inputs and bounded assumptions

| Parameter | Symbol | Value | Unit | Basis |
| --- | --- | --- | --- | --- |
| Total ports | N | 80 | ports | Use-case definition (r9) |
| AC share of ports | fAC | 0.70 | ratio | Model assumption; consistent with overnight-dwell depot mixes discussed in IEA Global EV Outlook 2024 (https://www.iea.org/) |
| DC share of ports | fDC | 0.30 | ratio | Model assumption; complement of fAC |
| AC unit power (Huawei SCharger-22KT-S1) | PAC | 22 | kW | OEM datasheet, https://solar.huawei.com/en; standard IEC 61851-1:2017, https://webstore.iec.ch/en/publication/33644 |
| DC unit power (Growatt TH-S 60K-T2) | PDC | 60 | kW | OEM product page, https://www.growatt.com/; standard IEC 61851-1:2017 |
| Energy per port per day | Ed | 45 | kWh/day/port | Model assumption (light-commercial van proxy) |
| Site utilisation | U | 0.65 | ratio | Model assumption (r9) |
| Operating days per year | D | 330 | days/yr | Model assumption (r9) |
| Project horizon | T | 10 | years | Scenario model input |
| Discount rate | r | 0.09 | ratio | Scenario model input (emerging-market nominal WACC proxy) |
| EVSE AC CapEx (per port, hardware + install) | CAC | 3,800 | USD/port | Model assumption (2024 MEA landed) |
| EVSE DC CapEx (per port, hardware + install) | CDC | 28,500 | USD/port | Model assumption (2024 MEA landed) |
| Grid connection / switchgear / step-up transformer (lump) | Cgrid | 210,000 | USD | Model assumption (PENDING site survey) |
| Annual O&M ratio (of CapEx) | kOM | 0.04 | ratio/yr | Model assumption (PENDING OEM service contract) |
| Tariff — base case | τ | 0.11 | USD/kWh | Model assumption (MEA commercial median) |
| Tariff — low / high | τL / τH | 0.08 / 0.14 | USD/kWh | Model assumption |
| Diesel baseline cost (per litre) | pd | **PENDING** — no OEM/regulator citation available. Re-validate against the destination country's national energy ministry or chamber of commerce at RFQ stage. |
| Diesel van fuel economy | Fd | 9.5 | L/100km | Model assumption (light-van proxy) |
| EV equivalent consumption | Fe | 0.18 | kWh/km | Model assumption (medium-van proxy) |
| Annual km per van | K | 35,000 | km/yr | Model assumption (distribution-van proxy) |
| Residual value amount | RV | 0 | USD | Model assumption (terminal value excluded) |
| Residual value year | year | 10 | years | Model assumption (terminal year of horizon) |
| EV maintenance per km | mEV | 0.03 | USD/km | Model assumption (light-commercial EV) |
| ICE maintenance per km | mICE | 0.08 | USD/km | Model assumption (light-commercial diesel van) |
| ICE CapEx per vehicle (diesel van) | capICE | 38,000 | USD/vehicle | Model assumption |

Every cell above marked "Model assumption" is a bounded default of the scenario model. Cells marked "PENDING" must be replaced with a regulator/OEM citation or with a broker-confirmed value before publication of any procurement contract.

## 2. computed TCO summary (scenario model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 10 |
| Discount rate | 9.00 % |
| Total undiscounted cost (USD) | 2,521,657.25 |
| Total discounted cost / PV of costs (USD) | 2,002,222.72 |
| Total undiscounted benefit (USD) | 4,198,600.00 |
| Total discounted benefit (USD) | 2,694,517.76 |
| NPV (USD) | 692,295.05 |
| IRR | 0.2206 |
| Simple payback (year) | 3.86 |
| Discounted payback (year) | 4.97 |
| TCO per km — EV (USD/km) | 0.1093 |
| TCO per km — ICE (USD/km) | 0.3340 |
| Savings per km (USD/km) | 0.2247 |
| Savings over horizon (USD) | 6,291,800.00 |

## 3. Year-by-year cash flow (scenario model)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 1,106,800.00 | 0.0000 | -1,106,800.00 | 1.00 | -1,106,800.00 | 0.0000 |
| 1 | 129,214.00 | 419,860.00 | 290,646.00 | 0.9174 | 266,647.71 | 0.0000 |
| 2 | 131,798.28 | 419,860.00 | 288,061.72 | 0.8417 | 242,455.79 | 0.0000 |
| 3 | 134,434.25 | 419,860.00 | 285,425.75 | 0.7722 | 220,401.05 | 0.0000 |
| 4 | 137,122.93 | 419,860.00 | 282,737.07 | 0.7084 | 200,298.07 | 0.0000 |
| 5 | 139,865.39 | 419,860.00 | 279,994.61 | 0.6499 | 181,977.29 | 0.0000 |
| 6 | 142,662.70 | 419,860.00 | 277,197.30 | 0.5963 | 165,283.69 | 0.0000 |
| 7 | 145,515.95 | 419,860.00 | 274,344.05 | 0.5470 | 150,075.59 | 0.0000 |
| 8 | 148,426.27 | 419,860.00 | 271,433.73 | 0.5019 | 136,223.44 | 0.0000 |
| 9 | 151,394.80 | 419,860.00 | 268,465.20 | 0.4604 | 123,608.84 | 0.0000 |
| 10 | 154,422.69 | 419,860.00 | 265,437.31 | 0.4224 | 112,123.59 | 0.0000 |

Discounted payback of 4.97 years is the time at which the cumulative discounted net cash flow turns non-negative, computed from the scenario model on the same 9.00% basis as PV of costs and PV of benefits above.

## 4. Sensitivity tables (consistent discounted-cash basis)

All sensitivity tables below hold the model inputs above constant except for the row's stated lever. Both cost and benefit legs are discounted at 9.00% over the 10-year horizon, so payback figures are on the same discounted basis as Section 2.

### 4.1 Sensitivity to tariff (τ)

| τ (USD/kWh) | Annual Opex (USD) | Annual benefit (USD) | PV costs (USD) | PV benefits (USD) | NPV (USD) | Discounted payback (yr) |
| --- | --- | --- | --- | --- | --- | --- |
| 0.08 | 106,048.00 | 419,860.00 | 1,785,750.62 | 2,694,517.76 | 908,767.14 | 4.10 |
| 0.10 | 121,492.00 | 419,860.00 | 1,930,174.56 | 2,694,517.76 | 764,343.20 | 4.49 |
| 0.11 (base) | 129,214.00 | 419,860.00 | 2,002,222.72 | 2,694,517.76 | 692,295.05 | 4.97 |
| 0.13 | 144,658.00 | 419,860.00 | 2,146,646.66 | 2,694,517.76 | 547,871.10 | 5.45 |
| 0.14 | 152,380.00 | 419,860.00 | 2,218,857.52 | 2,694,517.76 | 475,660.24 | 5.69 |

### 4.2 Sensitivity to utilisation (U)

| U (ratio) | Annual energy (kWh) | Annual benefit (USD) | PV benefits (USD) | PV costs (USD) | NPV (USD) | Discounted payback (yr) |
| --- | --- | --- | --- | --- | --- | --- |
| 0.40 | 475,200.00 | 209,930.00 | 1,347,258.88 | 1,851,113.86 | -503,854.98 | > 10.00 |
| 0.55 | 653,400.00 | 341,136.25 | 2,189,545.68 | 1,948,608.94 | 240,936.74 | 6.78 |
| 0.65 (base) | 772,200.00 | 419,860.00 | 2,694,517.76 | 2,002,222.72 | 692,295.05 | 4.97 |
| 0.75 | 891,000.00 | 498,583.75 | 3,199,489.83 | 2,055,836.49 | 1,143,653.34 | 3.84 |
| 0.85 | 1,009,800.00 | 577,307.50 | 3,704,461.91 | 2,109,450.27 | 1,595,011.64 | 3.15 |

### 4.3 Sensitivity to AC:DC split (fAC)

| fAC | NAC | NDC | CapEx total (USD) | Annual Opex (USD) | PV costs (USD) | PV benefits (USD) | NPV (USD) | Discounted payback (yr) |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 0.50 | 40 | 40 | 1,502,000.00 | 144,654.00 | 2,535,303.86 | 2,694,517.76 | 159,213.90 | 8.79 |
| 0.60 | 48 | 32 | 1,304,400.00 | 136,952.00 | 2,268,763.30 | 2,694,517.76 | 425,754.46 | 6.35 |
| 0.70 (base) | 56 | 24 | 1,106,800.00 | 129,214.00 | 2,002,222.72 | 2,694,517.76 | 692,295.05 | 4.97 |
| 0.80 | 64 | 16 | 909,200.00 | 121,512.00 | 1,735,682.16 | 2,694,517.76 | 958,835.60 | 3.99 |
| 0.90 | 72 | 8 | 711,600.00 | 113,810.00 | 1,469,141.60 | 2,694,517.76 | 1,225,376.16 | 3.31 |

Each row: NAC = 80 · fAC; NDC = 80 · (1 − fAC); CapExtotal = NAC · 3,800 + NDC · 28,500 + 210,000; Annual Opex = 84,942 (energy) + 0.04 · CapExtotal (O&M); PV costs = CapExtotal + Annual Opex · 6.418; PV benefits held at the computed 2,694,517.76 because annual energy delivered does not depend on the AC:DC split. Both legs are discounted at 9.00%.

## 5. Verdict by scenario

| Scenario | Tag | NPV (USD) | Discounted payback (yr) | Verdict |
| --- | --- | --- | --- | --- |
| Tariff 0.08 USD/kWh | Low-tariff | 908,767.14 | 4.10 | Proceed — strongest economics. |
| Tariff 0.11 USD/kWh (base) | Base | 692,295.05 | 4.97 | Proceed — payback inside 10-yr horizon. |
| Tariff 0.14 USD/kWh | High-tariff | 475,660.24 | 5.69 | Proceed — still inside horizon; recheck at refresh. |
| Utilisation 0.40 | Low-use | -503,854.98 | > 10.00 | Defer — NPV negative; stage deployment. |
| Utilisation 0.85 | High-use | 1,595,011.64 | 3.15 | Proceed — strongest unit-economics. |
| Split 50:50 AC:DC (more DC) | DC-heavy | 159,213.90 | 8.79 | Conditional — only if turnaround requires DC. |
| Split 90:10 AC:DC | AC-heavy | 1,225,376.16 | 3.31 | Proceed — preferred for overnight dwell fleets. |

## 6. HS code block (duty rates marked PENDING)

| HS code (WCO HS 2022, 6-digit) | Description | Duty rate — MEA destination | Lookup path |
| --- | --- | --- | --- |
| 8537.10 | Boards, panels, consoles for electric control / distribution (charging-station switchgear) | **PENDING** | Confirm at the destination customs authority (e.g., SARS, GRA, URA) and at the origin chamber of commerce. |
| 8504.40 | Static converters — AC/DC chargers | **PENDING** | Confirm with the destination tariff schedule; for the EU use the TARIC consultation at https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en. |
| 8536.69 | Plugs, sockets, connectors for EVSE | **PENDING** | Confirm at the destination customs authority. |
| 8507.60 | Lithium-ion accumulators (if bundled buffer storage) | **PENDING** | Confirm at the destination customs authority; for EU see Regulation (EU) 2023/1542 at https://eur-lex.europa.eu/eli/reg/2023/1542/oj. UN transport testing per *UN Manual of Tests and Criteria* (UN 38.3), ST/SG/AC.10/11/Rev.7, see https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria. |

Cross-check any preferential origin (e.g., EU–GCC, AfCFTA, COMESA) that may reduce the MFN rate. The PENDING flag is intentional: duty rates change annually and are country-specific; tradvolt.com does not assert any duty rate as fact.

## 7. Standards and regulatory references

- IEC 61851-1:2017, *Electric vehicle conductive charging system — Part 1: General requirements*, edition 3.0 — [https://webstore.iec.ch/en/publication/33644](https://webstore.iec.ch/en/publication/33644).

- UL 1973, *Batteries for Use in Stationary and Motive Auxiliary Power Applications* — [https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973) (applicable if a buffer storage cabinet is bundled).

- Regulation (EU) 2023/1542 — EU Battery Regulation — [https://eur-lex.europa.eu/eli/reg/2023/1542/oj](https://eur-lex.europa.eu/eli/reg/2023/1542/oj) (for cells shipped into the EU/EEA).

- UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, UN 38.3 lithium-battery provisions — [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria).

- Open Charge Alliance, OCPP 1.6 / 2.0.1 — [https://www.openchargealliance.org/](https://www.openchargealliance.org/) (backend protocol; cite home + protocol name + version in text).

- IATA Dangerous Goods Regulations — [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/) (air-freight lithium-battery shipments).

- IPPC ISPM 15 (wood packaging) — [https://www.ippc.int/en/core-activities/standards-setting/ispms/](https://www.ippc.int/en/core-activities/standards-setting/ispms/).

- ICC Incoterms® 2020 — [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/).

- EU TARIC consultation — [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en).

- USITC Harmonized Tariff Schedule — [https://hts.usitc.gov/](https://hts.usitc.gov/).

- UK Global Tariff — [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/).

- Japan Customs (English) — [https://www.customs.go.jp/english/](https://www.customs.go.jp/english/).

- Australian Border Force — [https://www.abf.gov.au/](https://www.abf.gov.au/).

- IEA market data — [https://www.iea.org/](https://www.iea.org/) (used only as a directional reference for AC:DC depot mixes; specific data points are model assumptions).

## 8. Calls to action

**(1) Request a tailored RFQ for a distribution-hub EVSE 80-port deployment:** [/rfq/](/rfq/).

No datasheet, brochure, or quotation is bundled with this page; hardware model names are listed for procurement reference, and final datasheet revisions are confirmed during the RFQ stage.