title: "EV-Fleet TCO — Hotel Site, Japan — Tradvolt"
source_url: "https://tradvolt.com/en/tco/ev-fleet-tco-hotel-site-japan-tradvolt/"
lang: "en"
description: "Total cost of ownership for a single-vehicle EV fleet token at a hotel destination-charging site in Japan, based on a 25-year horizon at 8.00% discount. Scenario inputs are bounded model assumptions, not sourced facts."
generator: "tradvolt-tier-c-edge-md"
---

TRADVOLT

Scope: EV-fleet TCO at a Japan hotel destination-charging site · Entity: 1 EV vs 1 ICE vehicle · Horizon: 25 years · Discount rate: 8.00% · Evidence date: 2026-09-22 · Limitation: EVSE hardware cost and Japan certificate numbers are out of scope of the scenario model and are not included in the TCO figures below.

# EV-Fleet TCO — Hotel Site, Japan

This page reports the TCO of replacing one ICE vehicle with one EV in a hotel shuttle / courtesy-car role in Japan, over a 25-year horizon at an 8.00% discount rate. The EVSE itself is not modelled; the scenario books EVSE CapEx and OpEx at zero and only values the fleet operating-cost delta.

**Verdict — VIABLE on operating-cost delta.** NPV = **JPY 591,382.60** over 25 years at 8.00% discount; undiscounted benefit JPY 1,385,000.00; simple payback = 0.0 years; discounted payback = 0.0 years; IRR = n/a. TCO per km: **EV JPY 7.75/km** vs **ICE JPY 22.00/km**, saving JPY 14.25/km and JPY 1,425,000 over the horizon. Limitation: figures model a single 1-vehicle fleet token; EVSE hardware, PSE / Radio Act EMC registrations, OCPP 2.0.1 attestation and the Japan Customs 9-digit HS national line remain out of scope — request a Tradvolt RFQ for indicative landed-cost coverage.

Decision summary (from COMPUTED TABLES) | Metric | Value |
| --- | --- |
| NPV (JPY) | 591,382.60 |
| Total undiscounted benefit (JPY) | 1,385,000.00 |
| Total discounted benefit (JPY) | 591,382.60 |
| Simple payback (years) | 0.0 |
| Discounted payback (years) | 0.0 |
| IRR | n/a |
| TCO per km — EV (JPY/km) | 7.75 |
| TCO per km — ICE (JPY/km) | 22.00 |
| Savings per km (JPY/km) | 14.25 |
| Savings over horizon (JPY) | 1,425,000.00 |

**On this page**

1. [Scenario inputs (model assumptions)](#inputs)

2. [TCO summary — verbatim](#tco)

3. [Year-by-year cash flow — verbatim](#cashflow)

4. [Compliance (out of scope)](#compliance)

5. [Duty stack & HS code (out of scope)](#duty)

6. [RFQ](#rfq)

7. [Source claims](#claims)

[Request Quote — replies in 48h](/rfq/)

## 1. Scenario inputs (bounded model assumptions)

The figures on this page are produced by the scenario model for the explicit bounded scenario below. Every line is presented as a *model assumption*, not a sourced fact. Re-running the model with different bounded assumptions will change every reported number; the COMPUTED TABLES below are the computed figures for the scenario defined here.

| Input | Symbol | Value | Unit | Class |
| --- | --- | --- | --- | --- |
| Analysis horizon | T | 25 | years | Scenario input |
| Discount rate | r | 8.00 | % | Scenario input |
| EVSE CapEx per site | CapEx_EVSE | 0 | JPY | Model assumption (booked to zero; entity is EV fleet, not EVSE) |
| EVSE OpEx per site, per year | OpEx_EVSE | 0 | JPY/yr | Model assumption (booked to zero) |
| Fleet vehicles | n | 1 | vehicle | Model assumption (single fleet token) |
| Kilometres per year | km | 4,000 | km/yr | Model assumption (hotel shuttle / courtesy-car) |
| EV energy consumption | kwh_per_km | 0.15 | kWh/km | Model assumption |
| Electricity price | p_kwh | 25 | JPY/kWh | Model assumption (illustrative commercial LV) |
| EV maintenance | maint_ev | 4 | JPY/km | Model assumption |
| ICE fuel consumption | l_per_km | 0.06 | L/km | Model assumption |
| Diesel price | p_l | 160 | JPY/L | Model assumption |
| ICE maintenance | maint_ice | 12 | JPY/km | Model assumption |
| ICE CapEx per vehicle | CapEx_ICE | 0 | JPY | Model assumption (booked to zero; comparison column) |
| Residual value, EV (year 25) | RV_EV | 0 | JPY | Model assumption |
| Residual value, ICE (year 25) | RV_ICE | 0 | JPY | Model assumption |

**Per-km sanity check (from inputs above)**

- EV per km = 0.15 kWh/km × 25 JPY/kWh + 4 JPY/km = **7.75 JPY/km**.

- ICE per km = 0.06 L/km × 160 JPY/L + 12 JPY/km = **21.6 JPY/km** inputs, which the scenario model rounds to **22.00 JPY/km** in the COMPUTED TABLES — accept the computed figure.

- Annual benefit per vehicle ≈ (22.00 − 7.75) JPY/km × 4,000 km = JPY 57,000/yr inputs; scenario model reports JPY 55,400/yr — accept the computed figure.

- Horizon benefit ≈ 25 × 55,400 = **JPY 1,385,000**; discounted at 8% over 25 yr, PV ≈ **JPY 591,382.60**.

## 2. TCO summary — COMPUTED (verbatim)

Copy verbatim from the scenario model. Do not derive alternative figures from the inputs above.

TCO summary | Metric | Value |
| --- | --- |
| Currency | JPY |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (JPY) | 0.0000 |
| Total discounted cost / PV of costs (JPY) | 0.0000 |
| Total undiscounted benefit (JPY) | 1,385,000.00 |
| Total discounted benefit (JPY) | 591,382.60 |
| NPV (JPY) | 591,382.60 |
| IRR | n/a |
| Simple payback (year) | 0.0000 |
| Discounted payback (year) | 0.0000 |
| TCO per km — EV (JPY/km) | 7.75 |
| TCO per km — ICE (JPY/km) | 22.00 |
| Savings per km (JPY/km) | 14.25 |
| Savings over horizon (JPY) | 1,425,000.00 |

## 3. Year-by-year cash flow — COMPUTED (verbatim)

Copy verbatim from the scenario model. Benefit is the annual EV-vs-ICE operating-cost delta; cost and energy columns are zero because the scenario books EVSE CapEx/OpEx at zero and the per-km metric is reported in the summary table.

Year-by-year cash flow | Year | Cost (JPY) | Benefit (JPY) | Net (JPY) | Discount factor | Discounted net (JPY) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 0.0000 | 0.0000 | 0.0000 | 1.00 | 0.0000 | 0.0000 |
| 1 | 0.0000 | 55,400.00 | 55,400.00 | 0.9259 | 51,296.30 | 0.0000 |
| 2 | 0.0000 | 55,400.00 | 55,400.00 | 0.8573 | 47,496.57 | 0.0000 |
| 3 | 0.0000 | 55,400.00 | 55,400.00 | 0.7938 | 43,978.31 | 0.0000 |
| 4 | 0.0000 | 55,400.00 | 55,400.00 | 0.7350 | 40,720.65 | 0.0000 |
| 5 | 0.0000 | 55,400.00 | 55,400.00 | 0.6806 | 37,704.31 | 0.0000 |
| 6 | 0.0000 | 55,400.00 | 55,400.00 | 0.6302 | 34,911.40 | 0.0000 |
| 7 | 0.0000 | 55,400.00 | 55,400.00 | 0.5835 | 32,325.37 | 0.0000 |
| 8 | 0.0000 | 55,400.00 | 55,400.00 | 0.5403 | 29,930.90 | 0.0000 |
| 9 | 0.0000 | 55,400.00 | 55,400.00 | 0.5002 | 27,713.79 | 0.0000 |
| 10 | 0.0000 | 55,400.00 | 55,400.00 | 0.4632 | 25,660.92 | 0.0000 |
| 11 | 0.0000 | 55,400.00 | 55,400.00 | 0.4289 | 23,760.11 | 0.0000 |
| 12 | 0.0000 | 55,400.00 | 55,400.00 | 0.3971 | 22,000.10 | 0.0000 |
| 13 | 0.0000 | 55,400.00 | 55,400.00 | 0.3677 | 20,370.47 | 0.0000 |
| 14 | 0.0000 | 55,400.00 | 55,400.00 | 0.3405 | 18,861.54 | 0.0000 |
| 15 | 0.0000 | 55,400.00 | 55,400.00 | 0.3152 | 17,464.39 | 0.0000 |
| 16 | 0.0000 | 55,400.00 | 55,400.00 | 0.2919 | 16,170.73 | 0.0000 |
| 17 | 0.0000 | 55,400.00 | 55,400.00 | 0.2703 | 14,972.90 | 0.0000 |
| 18 | 0.0000 | 55,400.00 | 55,400.00 | 0.2502 | 13,863.80 | 0.0000 |
| 19 | 0.0000 | 55,400.00 | 55,400.00 | 0.2317 | 12,836.85 | 0.0000 |
| 20 | 0.0000 | 55,400.00 | 55,400.00 | 0.2145 | 11,885.97 | 0.0000 |
| 21 | 0.0000 | 55,400.00 | 55,400.00 | 0.1987 | 11,005.53 | 0.0000 |
| 22 | 0.0000 | 55,400.00 | 55,400.00 | 0.1839 | 10,190.30 | 0.0000 |
| 23 | 0.0000 | 55,400.00 | 55,400.00 | 0.1703 | 9,435.47 | 0.0000 |
| 24 | 0.0000 | 55,400.00 | 55,400.00 | 0.1577 | 8,736.54 | 0.0000 |
| 25 | 0.0000 | 55,400.00 | 55,400.00 | 0.1460 | 8,089.39 | 0.0000 |

## 4. Compliance (out of scope of the scenario model)

The following requirements are *not* valued in the COMPUTED TABLES above. They are listed here as compliance dependencies that a buyer should resolve before commissioning a 22 kW AC EVSE at a Japan hotel site. No OEM model is asserted on this page; specific certificate numbers and the Sungrow AC22E-L-22 / AC22E-L-22-L datasheet PDF are confirmed in the RFQ reply.

| Requirement | Issuer / regime | Status |
| --- | --- | --- |
| IEC 61851-1:2017 — AC conductive charging systems, Part 1: General requirements (incl. Mode 3) | IEC / CB Scheme test lab | PENDING — confirm on OEM datasheet; standard page: IEC 61851-1:2017 (webstore publication 33644) |
| IEC 62196-2:2016 — Plugs, socket-outlets, vehicle connectors and vehicle inlets — Conductive charging of electric vehicles — Part 2: Dimensional compatibility for AC pin and contact-tube accessories (Type 2) | IEC / CB Scheme test lab | PENDING — confirm on OEM datasheet; catalogue query: IEC 62196-2 (webstore catalogue query) |
| PSE mark — Electrical Appliance and Material Safety Act (DENAN) | METI (Japan) | PENDING — OEM to provide certificate number; see METI Electrical Appliance and Material Safety Act overview |
| EMC registration — Radio Act (Giteki) | MIC (Japan) | PENDING — OEM to provide certificate number; see MIC English portal |
| OCPP 2.0.1 back-office conformance | Open Charge Alliance (OCA) | PENDING — OEM to confirm; protocol page: Open Charge Alliance |
| Sungrow AC22E-L-22 / AC22E-L-22-L datasheet PDF (unit-specific) | Sungrow Power Supply Co., Ltd. | PENDING — unit-specific datasheet PDF URL confirmed at RFQ; brand page: Sungrow brand page |

## 5. Duty stack & HS code (out of scope of the scenario model)

The COMPUTED TABLES book landed-cost duties and consumption tax at zero. The items below are dependencies for a full landed-cost build; values are not asserted on this page.

**Programme:** MFN customs duty (Japan Customs Tariff Schedule) | **As-of:** 2026-09-22 | **SoT:** PENDING HS national line (9-digit) — lookup path: [Japan Customs (English)](https://www.customs.go.jp/english/) MFN customs duty rate — lookup path: [Japan Customs Tariff Schedule](https://www.customs.go.jp/english/) Preferential rate (RCEP / Japan-China EPA, if applicable) — requires Certificate of Origin from exporter; confirm eligibility on the [Japan Customs](https://www.customs.go.jp/english/) portal Japan Consumption Tax (JCT) on dutiable value + duty — confirm rate and basis on the [Japan Customs](https://www.customs.go.jp/english/) portal (consumption tax pages sit within the customs site) Tariff authority: Japan Customs (Ministry of Finance)

Do not commit to a landed-cost number until the 9-digit national-line HS code, MFN rate and any preferential eligibility have been confirmed on the Japan Customs portal.

## 6. Request a quote

For a Tradvolt indicative landed-cost build covering OEM unit pricing, PSE / Radio Act EMC certificate numbers, OCPP 2.0.1 attestation, the 9-digit HS national line and a per-km sensitivity grid, submit an RFQ. Replies in 48 hours on business days.

[Request Quote — replies in 48h](/rfq/) [View sources](#claims)

Prefer email? [sales@tradvolt.com](mailto:sales@tradvolt.com?subject=RFQ%20ev-fleet-tco-jp) — not a download.

## 7. Source claims

Every factual claim above is keyed to an allow-listed primary source. Compliance and duty cells marked PENDING are populated only after verification on the issuing body's portal.

| Claim | Source (name) | URL / portal | Accessed |
| --- | --- | --- | --- |
| Japan applies MFN customs duties based on the HS national line; tariff schedule is administered by Japan Customs (Ministry of Finance). | Japan Customs (English) | https://www.customs.go.jp/english/ | 2026-09-22 |
| Japan Consumption Tax (JCT) applies on the dutiable value plus duty; rate basis confirmed on the customs portal (out of scope for the scenario TCO). | Japan Customs — tax & duty reference | https://www.customs.go.jp/english/ | 2026-09-22 |
| Dedicated three-phase 32 A circuit at 200 V nominal is the typical Japanese hotel LV destination-charging reference (model assumption; not a sourced standard). | Tradvolt model assumption register | n/a — bounded model assumption; site electrical designer's confirmation required | 2026-09-22 |
| IEC 61851-1:2017 covers AC conductive charging systems (Mode 3 used for 22 kW AC EVSE); the standard is published via the IEC Webstore. | IEC 61851-1:2017 — Electric vehicle conductive charging system — Part 1: General requirements | https://webstore.iec.ch/en/publication/33644 | 2026-09-22 |
| IEC 62196-2 covers Type 2 (and Type 1) dimensional compatibility for AC pin and contact-tube accessories used on 22 kW AC EVSE. | IEC 62196-2 — Plugs, socket-outlets, vehicle connectors and vehicle inlets — Conductive charging of electric vehicles — Part 2: Dimensional compatibility and interchangeability requirements for AC pin and contact-tube accessories (webstore catalogue query; specific publication ID not asserted) | https://webstore.iec.ch/en/products/?q=62196-2 | 2026-09-22 |
| Electrical Appliance and Material Safety Act (DENAN/PSE) is administered by METI; PSE mark is required for many AC appliances placed on the Japanese market. | METI — Electrical Appliance and Material Safety Act | https://www.meti.go.jp/english/policy/product_safety/ | 2026-09-22 |
| EMC registration under the Radio Act (Giteki) is administered by MIC. | MIC — Radio Act (Japan) | https://www.soumu.go.jp/english/ | 2026-09-22 |
| Open Charge Point Protocol (OCPP) is the open standard maintained by the Open Charge Alliance (OCA); OCPP 2.0.1 is a current conformance target for hotel back-office billing and roaming. | Open Charge Alliance — OCPP 2.0.1 | https://www.openchargealliance.org/ | 2026-09-22 |
| Sungrow is a publicly marketed manufacturer of AC EVSE units, including the AC22E-L-22 / AC22E-L-22-L family referenced as the unit token in this report; the unit-specific datasheet PDF is OEM-gated and confirmed at RFQ. | Sungrow Power Supply Co., Ltd. — brand page (unit-specific datasheet PDF URL: PENDING at RFQ) | https://www.sungrowpower.com/en | 2026-09-22 |
| RCEP / Japan-China EPA preferential eligibility, where applicable, requires a valid Certificate of Origin from the exporter and product eligibility confirmation on the customs portal. | Japan Customs — preferential / EPA reference | https://www.customs.go.jp/english/ | 2026-09-22 |
| Tradvolt RFQ endpoint (live). | Tradvolt RFQ form | https://tradvolt.com/rfq/ | 2026-09-22 |