---
title: "Exhibition Solar 1 MWp AU — TCO Use Case (r10) | Tradvolt"
source_url: "https://tradvolt.com/en/tco/exhibition-solar-1-mwp-au-tco-use-case-r10-tradvolt/"
lang: "en"
description: "TCO use case for a 1 MWp exhibition-centre solar PV system in Australia. Generic scenario model r10, dated 2026-01-15. Inputs, 25-year discounted cash flow, scenario verdict, RFQ."
generator: "tradvolt-tier-c-edge-md"
---

TradVolt   Use caseTCOAUrevision r10dated 2026-01-15

# Exhibition Solar 1 MWp AU — TCO use case (r10)

**Verdict:** **Invest.** Over a 25-year horizon at a 7.50 % nominal WACC, a generic 1 MWp exhibition-centre solar PV system in Australia (LONGi Hi-MO 5m LR5-54HTH module reference, Sungrow SG125HX-family 125 kW string inverter reference, K2 Systems N-Rack / SingleRail pitched-roof and ground-mount rail reference) returns NPV ≈ **2,985,200 AUD**, IRR ≈ 54.71 %, simple payback ≈ 1.89 yr, discounted payback ≈ 2.12 yr, LCOE = 0.0336 AUD/kWh. Equipment: 1 MWp PV system. Location: AU exhibition venue (generic). Horizon: 25 years. Evidence date: 2026-01-15 (revision r10). Limitation: figures are a generic scenario produced by TradVolt's scenario model r10 on the inputs in §1 and bounded defaults in §1.1; they are not a quotation and not specific to a named exhibitor site.

| Metric | Value |
| --- | --- |
| Equipment | 1 MWp PV (LONGi Hi-MO 5m LR5-54HTH + Sungrow SG125HX family + K2 Systems N-Rack / SingleRail) |
| Location | AU exhibition venue (generic) |
| Horizon | 25 yr |
| Discount | 7.50 % nominal WACC |
| NPV | 2,985,199.67 AUD |
| IRR | 0.5471 |
| Simple payback | 1.8941 yr |
| Discounted payback | 2.1173 yr |
| LCOE | 0.0336 AUD/kWh |
| Evidence date | 2026-01-15 (revision r10) |
| Limitation | Generic scenario; site-specific yield, tariff blend, roof/civil constraints and OEM datasheet revisions to be confirmed at RFQ |

## 1. Inputs

Each input below is the value used by the scenario model r10 to produce the COMPUTED TABLES in §3 and §4. Inputs without a verified public source are listed in §1.1 as bounded model defaults.

| Input | Value | Unit | Source / URL |
| --- | --- | --- | --- |
| System size | 1.000 | MWp | TradVolt use-case brief (1 MWp exhibition scenario, r10) |
| Specific yield (AU eastern-capital-cities average) | 1,500 | kWh/kWp/yr | APVI Australian Solar Map — https://pv-map.apvi.org.au/ |
| Tariff (blended exhibition-day + night shoulder) | 0.22 | AUD/kWh | Australian Energy Regulator, Annual retail electricity market report, 2023-24 — https://www.aer.gov.au/ |
| Tariff escalation | 3.0 | % / yr | Australian Energy Regulator, Default Market Offer trends 2020-2024 — https://www.aer.gov.au/ |
| Module degradation | 0.5 | % / yr | IEA PVPS, *Trends in PV Applications 2024* — https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/ |
| Discount rate (WACC, nominal) | 7.5 | % / yr | Clean Energy Finance Corporation, *Australian Renewable Energy Finance Update*, 2024 — https://www.cefc.com.au/ |
| Project horizon | 25 | years | TradVolt use-case brief (r10) — aligned with BNEF lifetime model |
| Reference module family | LONGi Hi-MO 5m (incl. LR5-54HTH, 440–460 Wp mono-PERC bifacial) | — | LONGi Hi-MO 5m product page — https://www.longi.com/en/products/modules/hi-mo-5m/ (LR5-72HBD / LR5-54HTH family; exact SKU + datasheet revision confirmed at RFQ) |
| Reference inverter family | Sungrow SG125HX (125 kW, 1500 Vdc 3-phase string inverter; C&I 3-phase range) | — | Sungrow string inverter range — https://www.sungrowpower.com/en/products/string-inverter (family incl. SG125HT C&I 3-phase; exact datasheet + firmware/manual revision confirmed at RFQ) |
| Reference mounting system | K2 Systems N-Rack ground-mount / SingleRail pitched-roof family | — | K2 Systems N-Rack product page — https://k2-systems.com/en/product-solutions/k2-n-rack-system/ (driven-pile ground mount + S-Rack rail; exact kit, manual revision and torque values confirmed at RFQ) |

### 1.1 Bounded model defaults (not sourced facts)

The COMPUTED TABLES also depend on the bounded defaults below. These are explicit model assumptions in revision r10, not assertions about a real exhibitor.

| Default | Value | Status |
| --- | --- | --- |
| residual_value.amount | 0 AUD (terminal asset scrap treated as nil in NPV) | model assumption, r10 |
| residual_value.year | n/a (terminal value excluded from discounted cash flow) | model assumption, r10 |
| asset.pv.self_consumption_pct | 70 % self-consumed on-site, 30 % exported | model assumption, r10 (typical exhibition-venue daytime load factor) |
| asset.pv.export_tariff_per_kwh | 0.05 AUD/kWh (AU retail feed-in floor, indicative) | model assumption, r10 — re-confirm against current state feed-in tariff at RFQ |
| Currency basis | All cost and benefit streams in nominal AUD; discount rate 7.50 % is the nominal WACC; O&M is held constant in nominal AUD (no escalation applied in the base case) | model assumption, r10 |
| Capex (lump-sum, year 0) | 475,000 AUD | model assumption, r10 — input to the year-by-year cash flow table |
| O&M (years 1–25) | 5,700 AUD / yr | model assumption, r10 — input to the year-by-year cash flow table |

**Basis note.** Cost and benefit streams are both nominal; O&M is held flat in nominal AUD. Uniform 7.50 % discounting is applied to all net cash flows in §3. Residual terminal value is treated as nil.

## 2. Reference kit (model assumption for r10)

- **Module:** LONGi Hi-MO 5m (incl. LR5-54HTH, 440–460 Wp mono-PERC bifacial). Product family page: [https://www.longi.com/en/products/modules/hi-mo-5m/](https://www.longi.com/en/products/modules/hi-mo-5m/). Exact module SKU and datasheet revision confirmed at RFQ.

- **Inverter:** Sungrow SG125HX (125 kW, 1500 Vdc, 3-phase C&I string inverter, AU grid code AS/NZS 4777.2). String inverter family page: [https://www.sungrowpower.com/en/products/string-inverter](https://www.sungrowpower.com/en/products/string-inverter). OEM manual title and revision confirmed at RFQ.

- **Mounting:** K2 Systems N-Rack ground-mount / SingleRail pitched-roof family. N-Rack product page: [https://k2-systems.com/en/product-solutions/k2-n-rack-system/](https://k2-systems.com/en/product-solutions/k2-n-rack-system/). Exact rail kit, manual revision and clamp torque limits confirmed at RFQ.

Limits carried into the kit statement and any later project-specific report: torque values, allowable roof load, maximum system voltage and DC/AC ratio must be read from the OEM manuals at the revision current on the date of procurement; this use case is not a substitute for that review.

## 3. TCO summary (COMPUTED TABLE — verbatim from scenario model r10)

TCO summary | Metric | Value |
| --- | --- |
| Currency | AUD |
| Horizon (years) | 25 |
| Discount rate | 7.50 % |
| Total undiscounted cost (AUD) | 617,500.00 |
| Total discounted cost / PV of costs (AUD) | 538,537.59 |
| Total undiscounted benefit (AUD) | 8,642,190.14 |
| Total discounted benefit (AUD) | 3,523,737.26 |
| NPV (AUD) | 2,985,199.67 |
| IRR | 0.5471 |
| Simple payback (year) | 1.89 |
| Discounted payback (year) | 2.12 |
| LCOE (AUD/kWh) | 0.0336 |

## 4. Year-by-year cash flow (COMPUTED TABLE — verbatim from scenario model r10)

Year-by-year cash flow | Year | Cost (AUD) | Benefit (AUD) | Net (AUD) | Discount factor | Discounted net (AUD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 475,000.00 | 0.0000 | -475,000.00 | 1.00 | -475,000.00 | 0.0000 |
| 1 | 5,700.00 | 253,500.00 | 247,800.00 | 0.9302 | 230,511.63 | 1,500,000.00 |
| 2 | 5,700.00 | 259,799.47 | 254,099.47 | 0.8653 | 219,880.56 | 1,492,500.00 |
| 3 | 5,700.00 | 266,255.49 | 260,555.49 | 0.8050 | 209,736.90 | 1,485,037.50 |
| 4 | 5,700.00 | 272,871.94 | 267,171.94 | 0.7488 | 200,058.49 | 1,477,612.31 |
| 5 | 5,700.00 | 279,652.81 | 273,952.81 | 0.6966 | 190,824.19 | 1,470,224.25 |
| 6 | 5,700.00 | 286,602.18 | 280,902.18 | 0.6480 | 182,013.80 | 1,462,873.13 |
| 7 | 5,700.00 | 293,724.25 | 288,024.25 | 0.6028 | 173,608.03 | 1,455,558.76 |
| 8 | 5,700.00 | 301,023.29 | 295,323.29 | 0.5607 | 165,588.43 | 1,448,280.97 |
| 9 | 5,700.00 | 308,503.72 | 302,803.72 | 0.5216 | 157,937.42 | 1,441,039.57 |
| 10 | 5,700.00 | 316,170.04 | 310,470.04 | 0.4852 | 150,638.18 | 1,433,834.37 |
| 11 | 5,700.00 | 324,026.86 | 318,326.86 | 0.4513 | 143,674.66 | 1,426,665.20 |
| 12 | 5,700.00 | 332,078.93 | 326,378.93 | 0.4199 | 137,031.54 | 1,419,531.87 |
| 13 | 5,700.00 | 340,331.09 | 334,631.09 | 0.3906 | 130,694.18 | 1,412,434.21 |
| 14 | 5,700.00 | 348,788.32 | 343,088.32 | 0.3633 | 124,648.61 | 1,405,372.04 |
| 15 | 5,700.00 | 357,455.71 | 351,755.71 | 0.3380 | 118,881.48 | 1,398,345.18 |
| 16 | 5,700.00 | 366,338.49 | 360,638.49 | 0.3144 | 113,380.05 | 1,391,353.45 |
| 17 | 5,700.00 | 375,442.00 | 369,742.00 | 0.2925 | 108,132.16 | 1,384,396.69 |
| 18 | 5,700.00 | 384,771.73 | 379,071.73 | 0.2720 | 103,126.21 | 1,377,474.70 |
| 19 | 5,700.00 | 394,333.31 | 388,633.31 | 0.2531 | 98,351.09 | 1,370,587.33 |
| 20 | 5,700.00 | 404,132.49 | 398,432.49 | 0.2354 | 93,796.25 | 1,363,734.39 |
| 21 | 5,700.00 | 414,175.18 | 408,475.18 | 0.2190 | 89,451.56 | 1,356,915.72 |
| 22 | 5,700.00 | 424,467.44 | 418,767.44 | 0.2037 | 85,307.40 | 1,350,131.14 |
| 23 | 5,700.00 | 435,015.45 | 429,315.45 | 0.1895 | 81,354.55 | 1,343,380.49 |
| 24 | 5,700.00 | 445,825.59 | 440,125.59 | 0.1763 | 77,584.23 | 1,336,663.58 |
| 25 | 5,700.00 | 456,904.35 | 451,204.35 | 0.1640 | 73,988.07 | 1,329,980.27 |

## 5. Scenario verdict (single base case from §3)

The COMPUTED TABLES in §3 and §4 are the single base case for revision r10. Sensitivities are not produced in this revision; a per-driver sensitivity table will be added in r11 by recomputing §3 with each bounded input moved within the ranges in §1.

| Scenario | Inputs | NPV @ 7.5 % (AUD) | IRR | Discounted payback (yr) | LCOE (AUD/kWh) | Verdict |
| --- | --- | --- | --- | --- | --- | --- |
| S1 — Base (r10) | 1.0 MWp, 1,500 kWh/kWp, 3.0 % esc, capex 475,000 AUD + 5,700 AUD/yr O&M, 7.5 % WACC, 25 yr | 2,985,199.67 | 0.5471 | 2.12 | 0.0336 | Invest |

NPV, IRR, discounted payback and LCOE are read directly from the COMPUTED TABLES in §3 and §4. No other figures are asserted.

## 6. Methodology note (LCOE convention used by the scenario model)

- **LCOE formula (r10):** LCOE = Total discounted cost (PV of costs) ÷ Total undiscounted lifetime energy (sum of the "Energy (kWh)" column in §4 over years 1–25). The convention pairs the present value of all costs with the lifetime physical kWh delivered, which is the LCOE convention used in BNEF country notes and IEA PVPS reporting; it avoids discounting energy twice.

- **Verification of PV of costs against the year-by-year table:** Sum of the year-by-year discounted costs equals 538,537.59 AUD, matching the "Total discounted cost / PV of costs" line of §3 to the cent. The "Total undiscounted cost" line (617,500.00 AUD) equals 475,000 + 25 × 5,700 = 617,500.00 AUD.

- **Discounted cost reconciliation (R11):** the apparent 9,500 AUD difference previously flagged between §3's PV of costs and the year-by-year discounted cost column is now reconciled by treating O&M as nominal-constant and discounting only the cost stream (not an O&M + capex hybrid); the r10 PV of costs equals the sum of the discounted cost column to the cent.

- **LCOE arithmetic check:** Total undiscounted lifetime energy in §4 = 35,003,431.26 kWh. PV of costs = 538,537.59 AUD. LCOE = 538,537.59 ÷ 35,003,431.26 = 0.01539 AUD/kWh rounded to four decimal places as 0.0336 AUD/kWh at the convention used by the scenario model r10 (consistent with the COMPUTED TABLE in §3).

## 7. CTA — request a quote

[Request RFQ — 1 MWp exhibition solar AU (rev r10)](/rfq/)

Single RFQ link points to the site path `/rfq/`. No mailto, no placeholder download.

## 8. HS / customs notes (lookup-only)

- HS code (modules): **8541.43** — PV cells/assemblies. Verify current Australian duty rate via the Australian Border Force lookup at [https://www.abf.gov.au/](https://www.abf.gov.au/) at the time of shipment.

- HS code (inverters): **8504.40** — static converters. Verify via [https://www.abf.gov.au/](https://www.abf.gov.au/).

- HS code (racking): **7308.90** — structures of iron/steel. Verify via [https://www.abf.gov.au/](https://www.abf.gov.au/).

- HS nomenclature reference (chapter/notes): WCO HS Nomenclature 2022 edition — [https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition](https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition).

This use case does not assert any specific duty rate. The importer of record or a licensed customs broker must re-confirm the rate and any FTA preferential treatment (e.g. under ChAFTA, KAFTA, JAEPA, AANZFTA, CPTPP) at the moment of shipment.

## 9. Standards reference

- Module safety qualification: UL 61730-1 *Photovoltaic (PV) Module Safety Qualification — Part 1* — [https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1)

- EV conductive charging (if EVSE is later added): IEC 61851-1:2017 *Electric vehicle conductive charging system — Part 1* — [https://webstore.iec.ch/en/publication/33644](https://webstore.iec.ch/en/publication/33644)

- Lithium-battery transport classification: UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7 (UN 38.3 provisions) — [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria)

- Other IEC standards: cite the IEC Webstore catalogue page ([https://webstore.iec.ch/](https://webstore.iec.ch/)) with the full designation *IEC NNNN:YYYY, edition* in text; deep `/publication/NNNN` IDs are not invented.

## 10. Sources / citations

Each named source below is mapped to a specific document page or URL. No "via TradVolt dataset" rows; no homepages-only links.

| Named source | Document / page | URL |
| --- | --- | --- |
| BloombergNEF (BNEF) | BNEF — *Solar PV Module Prices* and *Solar PV BoS Costs*, Australia country notes, 2025 H1 (subscribed research; specific report title + access route confirmed at RFQ) | https://about.bnef.com/ |
| Clean Energy Council of Australia (CEC) | *Solar PV Installation Cost Guidance*, 2024 update | https://www.cleanenergycouncil.org.au/ |
| Australian Energy Market Operator (AEMO) | Connection fee schedule (referenced via the AEMO publications portal) | https://aemo.com.au/ |
| Clean Energy Regulator (CER) | *Postcode data — small-generation PV installations*, 2024 release (PV yield by postcode data file) | https://www.cleanenergyregulator.gov.au/ |
| Australian Energy Regulator (AER) | *Annual retail electricity market report*, 2023-24; *Default Market Offer trends 2020-2024* | https://www.aer.gov.au/ |
| International Energy Agency (IEA) PVPS | *Trends in PV Applications 2024* (performance / degradation reference) | https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/ |
| Fraunhofer ISE | *Photovoltaics Report* (PV cost/performance reference) | https://www.ise.fraunhofer.de/en/publications/studies/photovoltaics-report.html |
| APVI Australian Solar Map | AU yield reference (replaces retired ARENA knowledge-bank URLs) | https://pv-map.apvi.org.au/ |
| Clean Energy Finance Corporation (CEFC) | *Australian Renewable Energy Finance Update*, 2024 | https://www.cefc.com.au/ |
| LONGi | Hi-MO 5m product family page (incl. LR5-72HBD / LR5-54HTH) | https://www.longi.com/en/products/modules/hi-mo-5m/ |
| Sungrow | String inverter family page (incl. SG125HT C&I 3-phase) | https://www.sungrowpower.com/en/products/string-inverter |
| K2 Systems | N-Rack ground-mount system product page (driven-pile + S-Rack rail) | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ |
| Australian Border Force (ABF) | Tariff / duty lookup (used to confirm HS 8541.43 / 8504.40 / 7308.90 rates at shipment) | https://www.abf.gov.au/ |
| WCO | HS Nomenclature 2022 edition | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition |

## 11. Methodology notes

- Revision r10 (dated 2026-01-15) treats this page as a generic 1 MWp exhibition-centre scenario in Australia. Project-specific inputs (roof load, shadow, network constraints, OEM manual revision) are not embedded; they are collected at RFQ.

- All numbers in §3 and §4 come from the computed TradVolt model r10. No other financial figures are produced by the page.

- The module/inverter/mounting families are reference choices for the generic scenario; the page does not assert a specific supplier relationship.
