title: "Factory Solar 5 MWp in LATAM — Use-Case TCO | Tradvolt"
source_url: "https://tradvolt.com/en/tco/factory-solar-5-mwp-in-latam-use-case-tco-tradvolt/"
lang: "en"
description: "Use-case and total cost of ownership for a 5 MWp factory-solar installation in Latin America. Inputs, transparent TCO tables, sensitivity, and verdict by scenario."
generator: "tradvolt-tier-c-edge-md"
---

# Factory Solar 5 MWp in LATAM — Use-Case & TCO

**Verdict.** At base inputs, a 5 MWp factory-solar plant in Latin America (LONGi Hi-MO 5m bifacial modules + Huawei SUN2000-330KTL-H1 string inverters on a K2 Systems N-Rack mounting system) returns an **NPV ≈ USD 6.45 M** over a 25-year horizon at a 9.00% WACC, with **discounted payback ≈ 5.63 yr** (simple payback 4.31 yr — undiscounted reference only), **IRR ≈ 24.67%**, and **LCOE ≈ USD 0.0524/kWh** versus a USD 0.115/kWh baseline industrial tariff. Decision: **proceed, subject to site-yield validation** (Solargis/PVGIS bankable study before FID). Equipment family: LONGi Hi-MO 5m LR5-72HBD/LR5-54HTH bifacial mono-PERC modules, Huawei SUN2000-330KTL-H1 3-phase 1500 V string inverters (50–330 kW units, ~15 inverters at 5 MWp DC), K2 Systems N-Rack ground-mount + S-Rack rail. Limitation: yield, degradation, performance-ratio and tariff-escalation values are model assumptions bounded to the cited references; obtain project-specific certificate numbers (e.g. IEC 61215 test report, IEC 61730, UL 61730-1) from the EPC at FID. Evidence date: 2026-01-15.

Decision summary — base inputs | Metric | Value |
| --- | --- |
| NPV (25 yr, 9.00% WACC) | USD 6,449,006.52 |
| IRR | 24.67% |
| Discounted payback | 5.63 yr (cumulative Σ PV(CF_j) crosses C0) |
| Simple payback (undiscounted reference) | 4.31 yr |
| LCOE | USD 0.0524/kWh |
| Baseline industrial tariff (assumed) | USD 0.115/kWh |
| PV of costs / PV of benefits | USD 4,118,346.74 / USD 10,567,353.25 |

## 1. Use-Case Snapshot

| Parameter | Value | Unit |
| --- | --- | --- |
| Use-case | Factory solar (rooftop + ground-mount hybrid) | — |
| Location (representative) | Latin America (LATAM) — well-sited, fixed-tilt ground-mount plus rooftop | — |
| DC capacity | 5,000 | kWp |
| Module family (in scope) | LONGi Hi-MO 5m LR5-72HBD / LR5-54HTH bifacial mono-PERC, 540–550 Wp class | — |
| Inverter family (in scope) | Huawei SUN2000-330KTL-H1, 330 kW 3-phase 1500 V DC, 8-MPPT string inverter (≈15 units) | — |
| Mounting (in scope) | K2 Systems N-Rack driven-pile ground-mount + S-Rack rail (rooftop variant) | — |
| Project life | 25 | years |

## 2. Inputs Table (Cited)

| # | Input | Value | Unit | Source | URL |
| --- | --- | --- | --- | --- | --- |
| I-1 | Module family (in scope) | LONGi Hi-MO 5m LR5-72HBD / LR5-54HTH | — | LONGi Hi-MO 5m product page | https://www.longi.com/en/products/modules/hi-mo-5m/ |
| I-2 | Inverter family (in scope) | Huawei SUN2000-330KTL-H1 (330 kW, 1500 V DC, 8 MPPT) | — | Huawei FusionSolar product page | https://solar.huawei.com/en/products/sun2000-330ktl-h1 |
| I-3 | Mounting system (in scope) | K2 Systems N-Rack driven-pile + S-Rack rail | — | K2 Systems N-Rack product page | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ |
| I-4 | Specific yield (LATAM average, fixed-tilt, well-sited) | 1,650 | kWh/kWp/yr | IRENA — Renewable Power Generation Costs in 2023 (LATAM annex, PV yield band) — model assumption bounded to source range | https://www.irena.org/Publications/2024/Sep/Renewable-power-generation-costs-in-2023 |
| I-5 | Module annual degradation | 0.40 | %/yr | NREL — Jordan & Kurtz, Photovoltaic Degradation Rates — An Analytical Review (NREL/CP-5200-XXXXX), p. analytical-review median for mono-PERC | https://www.nrel.gov/docs/fy22osti/80678.pdf |
| I-6 | Performance ratio (system availability / PR) | 82 | % | IEA PVPS — Trends in PV Applications 2024 (PR bands, Table – utility/C&I) | https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/ |
| I-7 | Industrial CAPEX (turnkey, 5 MWp LATAM) | 750 | USD/kWp | IRENA — Renewable Power Generation Costs in 2023 (LATAM utility-scale / commercial band) | https://www.irena.org/Publications/2024/Sep/Renewable-power-generation-costs-in-2023 |
| I-8 | Annual OPEX (O&M + insurance + inverter reserve) | 1.0 | % of CAPEX/yr | IRENA — Renewable Power Generation Costs in 2023, O&M assumptions for utility-scale PV | https://www.irena.org/Publications/2024/Sep/Renewable-power-generation-costs-in-2023 |
| I-9 | Industrial grid tariff — baseline (LATAM average) | 0.115 | USD/kWh | OLADE — Latin American Energy Organization, Panorama Energético regional tariffs | https://www.olade.org/publicaciones/panorama-energetico-de-america-latina-y-el-caribe/ |
| I-10 | Industrial tariff escalation | 3.0 | %/yr nominal | OLADE regional trend 2018–2023, applied as forward escalation assumption | https://www.olade.org/publicaciones/panorama-energetico-de-america-latina-y-el-caribe/ |
| I-11 | Discount rate (WACC, industrial PPA-backed) | 9.00 | %/yr | TradVolt editorial assumption — disclosed for transparency; user may substitute | — (model assumption) |
| I-12 | Residual value amount | 0 | USD | TradVolt editorial assumption (bounded to zero; no terminal salvage modeled) | — (model assumption) |
| I-13 | Residual value year | 25 | yr | TradVolt editorial assumption (residual measured at end of horizon) | — (model assumption) |
| I-14 | PV export tariff | 0 | USD/kWh | TradVolt editorial assumption (no export/wheeling revenue; all output offsets self-consumption); see OLADE for regulator-specific wheeling rates | https://www.olade.org/publicaciones/panorama-energetico-de-america-latina-y-el-caribe/ |

**Disclaimer on OEM manuals.** Module degradation 0.40%/yr and performance ratio 82% are bounded to the cited analytical review and IEA PVPS PR band; consult the LONGi Hi-MO 5m LR5-72HBD product page (above) for module-specific warranted degradation (e.g. 2-year ≥ 98%, linear to ≥ 85% at year 25) before FID. Inverter availability/prating are bounded to the SUN2000-330KTL-H1 product page (above). Mounting structural limits are bounded to the K2 Systems N-Rack product page (above); confirm ground-load and ballast with the K2 manual revision issued at the EPC award.

## 3. TCO Tables (Computed)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 9.00 % |
| Total undiscounted cost (USD) | 4,687,500.00 |
| Total discounted cost / PV of costs (USD) | 4,118,346.74 |
| Total undiscounted benefit (USD) | 30,000,020.22 |
| Total discounted benefit (USD) | 10,567,353.25 |
| NPV (USD) | 6,449,006.52 |
| IRR | 0.2467 |
| Simple payback (year) | 4.31 |
| Discounted payback (year) | 5.63 |
| LCOE (USD/kWh) | 0.0524 |

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 3,750,000.00 | 0.0000 | -3,750,000.00 | 1.00 | -3,750,000.00 | 0.0000 |
| 1 | 37,500.00 | 868,312.50 | 830,812.50 | 0.9174 | 762,213.30 | 8,250,000.00 |
| 2 | 37,500.00 | 890,784.43 | 853,284.43 | 0.8417 | 718,192.43 | 8,217,000.00 |
| 3 | 37,500.00 | 913,837.93 | 876,337.93 | 0.7722 | 676,693.67 | 8,184,132.00 |
| 4 | 37,500.00 | 937,488.05 | 899,988.05 | 0.7084 | 637,574.23 | 8,151,395.47 |
| 5 | 37,500.00 | 961,750.24 | 924,250.24 | 0.6499 | 600,699.24 | 8,118,789.89 |
| 6 | 37,500.00 | 986,640.34 | 949,140.34 | 0.5963 | 565,941.37 | 8,086,314.73 |
| 7 | 37,500.00 | 1,012,174.59 | 974,674.59 | 0.5470 | 533,180.38 | 8,053,969.47 |
| 8 | 37,500.00 | 1,038,369.67 | 1,000,869.67 | 0.5019 | 502,302.74 | 8,021,753.59 |
| 9 | 37,500.00 | 1,065,242.68 | 1,027,742.68 | 0.4604 | 473,201.28 | 7,989,666.58 |
| 10 | 37,500.00 | 1,092,811.16 | 1,055,311.16 | 0.4224 | 445,774.84 | 7,957,707.91 |
| 11 | 37,500.00 | 1,121,093.11 | 1,083,593.11 | 0.3875 | 419,927.93 | 7,925,877.08 |
| 12 | 37,500.00 | 1,150,107.00 | 1,112,607.00 | 0.3555 | 395,570.42 | 7,894,173.57 |
| 13 | 37,500.00 | 1,179,871.77 | 1,142,371.77 | 0.3262 | 372,617.28 | 7,862,596.88 |
| 14 | 37,500.00 | 1,210,406.85 | 1,172,906.85 | 0.2992 | 350,988.23 | 7,831,146.49 |
| 15 | 37,500.00 | 1,241,732.18 | 1,204,232.18 | 0.2745 | 330,607.54 | 7,799,821.91 |
| 16 | 37,500.00 | 1,273,868.21 | 1,236,368.21 | 0.2519 | 311,403.77 | 7,768,622.62 |
| 17 | 37,500.00 | 1,306,835.92 | 1,269,335.92 | 0.2311 | 293,309.48 | 7,737,548.13 |
| 18 | 37,500.00 | 1,340,656.83 | 1,303,156.83 | 0.2120 | 276,261.09 | 7,706,597.93 |
| 19 | 37,500.00 | 1,375,353.03 | 1,337,853.03 | 0.1945 | 260,198.59 | 7,675,771.54 |
| 20 | 37,500.00 | 1,410,947.17 | 1,373,447.17 | 0.1784 | 245,065.40 | 7,645,068.46 |
| 21 | 37,500.00 | 1,447,462.48 | 1,409,962.48 | 0.1637 | 230,808.13 | 7,614,488.18 |
| 22 | 37,500.00 | 1,484,922.81 | 1,447,422.81 | 0.1502 | 217,376.43 | 7,584,030.23 |
| 23 | 37,500.00 | 1,523,352.61 | 1,485,852.61 | 0.1378 | 204,722.83 | 7,553,694.11 |
| 24 | 37,500.00 | 1,562,776.98 | 1,525,276.98 | 0.1264 | 192,802.55 | 7,523,479.33 |
| 25 | 37,500.00 | 1,603,221.65 | 1,565,721.65 | 0.1160 | 181,573.35 | 7,493,385.42 |

Headline payback (5.63 yr) is computed from the discounted cash-flow series — the first year where cumulative Σ PV(CF_j) crosses C0 = USD 3,750,000. The simple payback figure (4.31 yr) is the undiscounted cumulative-cash crossing of C0 and is shown as a reference only; cost and benefit streams are both discounted in every headline figure (NPV, IRR, LCOE, discounted payback).

## 4. Sensitivity Table

Each scenario is recomputed from the same base inputs with only the indicated input changed. Headline figures below are derived by scaling the base NPV/LCOE/discounted-payback deltas with the input perturbation; treat as directional only — do not treat as fresh computed outputs.

| Scenario | CAPEX (USD/kWp) | Specific yield (kWh/kWp/yr) | Tariff escalation (%/yr) | Discount rate (%/yr) | NPV direction (USD) | LCOE direction (USD/kWh) | Discounted payback direction (yr) |
| --- | --- | --- | --- | --- | --- | --- | --- |
| Base | 750 | 1,650 | 3.0 | 9.00 | 6,449,007 (computed) | 0.0524 (computed) | 5.63 (computed) |
| CAPEX +10% | 825 | 1,650 | 3.0 | 9.00 | ↓ vs base | ↑ vs base | ↑ vs base |
| CAPEX −10% | 675 | 1,650 | 3.0 | 9.00 | ↑ vs base | ↓ vs base | ↓ vs base |
| Yield −15% | 750 | 1,403 | 3.0 | 9.00 | ↓↓ (likely negative) | ↑ vs base | ↑↑ vs base |
| Yield +10% | 750 | 1,815 | 3.0 | 9.00 | ↑ vs base | ↓ vs base | ↓ vs base |
| Tariff esc. 1.5% | 750 | 1,650 | 1.5 | 9.00 | ↓ vs base | = base (LCOE depends on cost side) | ↑ vs base |
| Tariff esc. 4.5% | 750 | 1,650 | 4.5 | 9.00 | ↑ vs base | = base | ↓ vs base |
| WACC 12% | 750 | 1,650 | 3.0 | 12.00 | ↓ vs base | ↑ vs base | ↑↑ vs base |
| WACC 7% | 750 | 1,650 | 3.0 | 7.00 | ↑ vs base | ↓ vs base | ↓ vs base |

**Yield caveat (R12 / R15).** The 0.40%/yr degradation and 82% PR are bounded to the cited NREL analytical review and the IEA PVPS Trends in PV Applications 2024 PR band; both are model assumptions bounded to the sources, not project-specific OEM-tested values. LONGi Hi-MO 5m module-level degradation warrants (per the LONGi product page) should be reviewed at FID; Huawei SUN2000-330KTL-H1 CEC/PR ratings should be confirmed against the Huawei product page datasheet at RFQ. Project-yield validation (PVGIS-SARAH2 / Solargis bankable study) is gating before FID — yield is the dominant NPV lever.

## 5. Verdict by Scenario

- **Base case (computed):** NPV USD 6,449,007; IRR 24.67%; LCOE USD 0.0524/kWh (well below the USD 0.115/kWh baseline tariff); discounted payback 5.63 yr; simple payback 4.31 yr (undiscounted reference). **Recommend: proceed with standard PPA/BOOT structure, subject to site yield validation.**

- **CAPEX +10%:** NPV direction ↓ vs base; verify EPC tender pressure or FX-linked module pricing before proceeding.

- **CAPEX −10%:** NPV direction ↑ vs base; highly attractive if achievable through competitive tender.

- **Yield −15% (shading, soiling, or weaker resource):** NPV direction ↓↓ (likely negative). Site yield validation is gating before FID.

- **Yield +10%:** NPV direction ↑ vs base; excellent if achievable via tracker upgrade or confirmed high-irradiation site.

- **Tariff escalation 1.5%:** NPV direction ↓ vs base; hedge or lock tariff via PPA where regulators allow.

- **Tariff escalation 4.5%:** NPV direction ↑ vs base; LATAM tariff pressure makes this plausible.

- **WACC 12%:** NPV direction ↓↓ vs base (likely marginal); recommend blended finance or a concessional facility to lower WACC.

- **WACC 7%:** NPV direction ↑↑ vs base; achievable with DFI-backed financing.

## 6. Compliance References (Standard Families)

Compliance references — standard families only; project-specific certificate numbers from EPC at FID  | Standard family | Edition / year | Scope | Publisher | Cited URL | Certificate number |
| --- | --- | --- | --- | --- | --- |
| IEC 61215 (Crystalline silicon PV modules — design qualification) | Edition 2 (IEC 61215-1:2021 / -1-2:2021 / -1-3:2021 / -1-4:2021 series) | Module design qualification (LONGi Hi-MO 5m family) | IEC | https://webstore.iec.ch/ (catalog query "IEC 61215") | Project-specific — obtain from EPC at FID (e.g. TÜV Rheinland / TÜV SÜD / UL / CQC test report number) |
| IEC 61730 (PV module safety qualification) | IEC 61730-1:2016 / IEC 61730-2:2016 | Module safety (LONGi Hi-MO 5m family) | IEC | https://webstore.iec.ch/ (catalog query "IEC 61730") | Project-specific — obtain from EPC at FID |
| UL 61730-1 (PV module safety qualification — US) | UL 61730-1 (current edition) | Module safety — US market (LONGi Hi-MO 5m family) | UL Standards | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 | Project-specific — obtain from EPC at FID |
| IEC 62109 (Power converter for PV — safety) | IEC 62109-1:2010 / IEC 62109-2:2011 | Inverter safety (Huawei SUN2000-330KTL-H1) | IEC | https://webstore.iec.ch/ (catalog query "IEC 62109") | Project-specific — obtain from EPC at FID |
| IEEE 1547 / IEC 61727 (grid interconnection) | IEEE 1547-2018 / IEC 61727:2004 | Grid interconnection (where applicable) | IEEE / IEC | https://webstore.iec.ch/ (catalog query "IEC 61727") | Project-specific — obtain from EPC at FID |
| UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7 (UN 38.3 lithium battery provisions — only relevant if paired BESS is added later) | Rev.7 (current) | Lithium battery transport classification | UNECE | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | Not applicable to this PV-only scope (would apply to paired storage such as BYD Energy Storage or CATL ESS) |

**Compliance disclaimer.** The references above are standard families (designations + editions + publishers). They are not project-specific certificates. Obtain project-specific test report / certificate numbers (e.g. IEC 61215 test report from TÜV Rheinland / TÜV SÜD / UL / CQC; UL 61730-1 attestation) from the EPC at FID.

## 7. HS Code & Customs Lookup (For Buyer/Importer Reference)

| HS heading (illustrative) | Item | Lookup tool | Status |
| --- | --- | --- | --- |
| 8541.43 | Photovoltaic cells and modules (laminated) | USITC HTS · EU TARIC · UK Global Tariff · NZ Working Tariff Document · WCO HS Nomenclature 2022 | PENDING — lookup required per destination country |
| 8504.40 | Static converters (inverters) | USITC HTS · EU TARIC · UK Global Tariff · NZ Working Tariff Document · WCO HS Nomenclature 2022 | PENDING — lookup required per destination country |
| 8504.23 | Liquid dielectric transformers (MV step-up) | USITC HTS · EU TARIC · UK Global Tariff · NZ Working Tariff Document | PENDING — lookup required per destination country |
| 7610.90 | Aluminium structures (mounting) | USITC HTS · EU TARIC · UK Global Tariff | PENDING — lookup required per destination country |
| 8544.49 | Other electric conductors (DC/AC cabling) | USITC HTS · EU TARIC · UK Global Tariff | PENDING — lookup required per destination country |

**HS code lookup instructions:** verify the exact heading, sub-heading, and any national/regional tariff amendments in the destination-country customs tariff before quoting (e.g. Brazilian Tarifa Externa Comum — TEC; Mexican TIGIE; Colombian Arancel de Aduanas; Chilean Arancel Aduanero). TradVolt does not assert any duty rate as fact and disclaims liability for customs decisions made on unverified codes. For LATAM-EU trade, see [Regulation (EU) 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj) where battery / storage annexes intersect.

## 8. Reference Documentation (Source URLs)

- LONGi Hi-MO 5m module family — [https://www.longi.com/en/products/modules/hi-mo-5m/](https://www.longi.com/en/products/modules/hi-mo-5m/)

- Huawei SUN2000-330KTL-H1 inverter — [https://solar.huawei.com/en/products/sun2000-330ktl-h1](https://solar.huawei.com/en/products/sun2000-330ktl-h1)

- K2 Systems N-Rack mounting system — [https://k2-systems.com/en/product-solutions/k2-n-rack-system/](https://k2-systems.com/en/product-solutions/k2-n-rack-system/)

- IRENA — Renewable Power Generation Costs in 2023 (LATAM annex) — [https://www.irena.org/Publications/2024/Sep/Renewable-power-generation-costs-in-2023](https://www.irena.org/Publications/2024/Sep/Renewable-power-generation-costs-in-2023)

- NREL — Jordan & Kurtz, Photovoltaic Degradation Rates — An Analytical Review — [https://www.nrel.gov/docs/fy22osti/80678.pdf](https://www.nrel.gov/docs/fy22osti/80678.pdf)

- IEA PVPS — Trends in PV Applications 2024 (PR bands) — [https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/](https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/)

- OLADE — Panorama Energético de América Latina y el Caribe — [https://www.olade.org/publicaciones/panorama-energetico-de-america-latina-y-el-caribe/](https://www.olade.org/publicaciones/panorama-energetico-de-america-latina-y-el-caribe/)

- EU PVGIS — photovoltaic calculator (SARAH2) — [https://re.jrc.ec.europa.eu/pvg_tools/en/](https://re.jrc.ec.europa.eu/pvg_tools/en/)

- IEC Webstore catalogue — [https://webstore.iec.ch/](https://webstore.iec.ch/) (catalog queries "IEC 61215", "IEC 61730", "IEC 62109", "IEC 61727")

- UL 61730-1 product page — [https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1)

- UN Manual of Tests and Criteria (UN 38.3) — [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria)

- WCO HS Nomenclature 2022 edition — [https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition](https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition)

- USITC Harmonized Tariff Schedule — [https://hts.usitc.gov/](https://hts.usitc.gov/)

- EU TARIC consultation — [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en)

- UK Global Tariff — [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/)

- NZ Customs Working Tariff Document — [https://www.customs.govt.nz/business/tariffs/working-tariff-document/](https://www.customs.govt.nz/business/tariffs/working-tariff-document/)

- Fraunhofer ISE Photovoltaics Report — [https://www.ise.fraunhofer.de/en/publications/studies/photovoltaics-report.html](https://www.ise.fraunhofer.de/en/publications/studies/photovoltaics-report.html)

- Bank of England Monetary Policy Report Aug 2025 (inflation context for WACC benchmark) — [https://www.bankofengland.co.uk/monetary-policy-report/2025/august-2025](https://www.bankofengland.co.uk/monetary-policy-report/2025/august-2025)

## 9. Calls to Action

Ready to scope a 5 MWp factory-solar project in LATAM? Request a formal technical-commercial proposal from TradVolt engineering:

[Request RFQ — Factory Solar 5 MWp LATAM](/rfq/?use_case=factory-solar-5mwp-latam-r9)