*Audience: B2B procurement, EPCs, food-court operators in Southeast Asia. Status: editorial brief, scenario model values. No prices are asserted as firm offers.*

## Verdict (answer-first)

**Equipment:** 200 kWp rooftop PV array using [Jinko Solar](https://www.jinkosolar.com/en/) Tiger Neo JKM570N-78HL4-BDV modules (570 W bifacial mono PERC, n-type) and [Sungrow](https://www.sungrowpower.com/en) SG125HT string inverters (125 kW, 1500 V DC). **Location:** Jakarta, Indonesia. **Horizon:** 25 years. **Discount rate:** 9.00%/yr (applied to BOTH cost and benefit cashflows on the same time basis). **Evidence date:** 22 September 2026. **Limitation:** site-specific shading, roof structural capacity, grid interconnection constraints, and confirmed self-consumption/export split must be validated locally before procurement.

| Metric | Value |
| --- | --- |
| NPV (USD) | 130,136.56 |
| IRR | 17.74 % |
| Simple payback (year) | 5.91 |
| Discounted payback (year) | 8.55 |
| LCOE (USD/kWh) | 0.0588 |
| Time basis | 25-year horizon; 9.00% discount applied to BOTH costs and benefits |
| Verdict | Proceed to RFQ at the modelled inputs; positive NPV, IRR > WACC, payback within typical SEA commercial debt tenor. |

Under the scenario model run (Year-0 capex 145,000.00 USD; flat annual opex 1,450.00 USD; inverter replacement 14,500.00 USD in Year 12 raising that year to 15,950.00 USD; Year-1 generation 296,000 kWh/yr declining 0.5%/yr; 3.0%/yr tariff escalation on the 0.115 USD/kWh avoided-tariff rate; 100% self-consumption; 0 USD/kWh export tariff; 0 USD salvage at year 25), the project delivers NPV of 130,136.56 USD, IRR 17.74%, simple payback 5.91 years, discounted payback 8.55 years, and LCOE 0.0588 USD/kWh.

## 1. Use-case fit

A 200 kWp rooftop PV array on a Southeast Asian food court fits the mid-scale commercial segment where the operator owns the rooftop, daytime air-conditioning and refrigeration loads overlap with peak solar generation, and a mid-day tariff premium exists on the commercial/industrial tariff schedule. Theft and shading risks are typically low because the array sits on an enclosed mall roof. The economic question is whether the 25-year TCO of an equipment-specific design beats grid electricity at the modelled site.

## 2. Inputs (cited)

| Input | Value | Unit | Source |
| --- | --- | --- | --- |
| PV module (family / wattage) | Jinko Tiger Neo JKM570N-78HL4-BDV, 570 W bifacial mono PERC, n-type | — | JinkoSolar — corporate landing; Tiger Neo product family page Tiger Neo EN; datasheet reference Tiger Neo JKM570N-78HL4-BDV datasheet (PDF) |
| String inverter (model) | Sungrow SG125HT, 125 kW, 1500 V DC | — | Sungrow — corporate landing; product page SG125HT; datasheet SG125HT datasheet (PDF) |
| Installed capacity | 200 | kWp | Brief assumption; 351 modules × 570 W |
| Specific yield (PVOUT) | 1,480 | kWh/kWp/yr | Global Solar Atlas — Indonesia, Jakarta (PVOUT) |
| System losses (soiling, inverter, cabling, mismatch) | 14 | % | IEC 61215:2021 — Crystalline silicon PV modules — Design qualification and type approval (test framework cited; loss figure treated as model assumption against the IEC design-qualification test envelope) |
| Performance ratio used for TCO | 0.86 | dimensionless | Model assumption: 1 − 14% = 0.86 |
| Average commercial tariff (blended) | 0.115 | USD/kWh | Indonesia MEMR / ESDM, commercial tariff 2023 (Indonesia Energy Outlook 2023, PDF) |
| Annual tariff escalation | 3.0 | %/yr | Model assumption; bounded by PLN historical CPI-linked adjustment range — confirm against IEA country profile at award |
| Annual module degradation | 0.5 | %/yr | Jordan & Kurtz, NREL/TP-5K00-80694 — Photovoltaic Degradation Rates—An Analytical Review (PDF) |
| Discount rate (WACC) | 9.00 | %/yr | Model assumption; reflects SEA commercial debt cost band; applied to BOTH cost and benefit cashflows (same time basis) |
| Project horizon | 25 | years | Standard PV economic life |
| Capex (turnkey, SEA rooftop) | 725 | USD/kWp | Model assumption; low end of IEA SEA rooftop solar cost band 2024 — confirm against local EPC quotes at award |
| Year-0 capex (USD) | 145,000.00 | USD | 200 kWp × 725 USD/kWp |
| Opex (annual) | 1.0 | % of capex/yr | Model assumption; covers O&M, insurance, monitoring |
| Inverter replacement (year 12) | 10 | % of capex (14,500 USD) | Model assumption; reserve reflecting typical <15-year component horizon for a 1500 V DC string inverter — confirm against Sungrow SG125HT product page warranty terms |
| Floor area required | ~1,100 | m² | Derived: 200 kWp / ~0.18 kWp/m² typical SEA tilt |

### 2.1 Model defaults (bounded assumptions where the draft did not state a value)

| Input | Value | Bounding note |
| --- | --- | --- |
| residual_value.amount (USD) | 0 | Lower bound: salvage assumed zero in PV LCOE convention; sensitivity to non-zero salvage omitted. |
| residual_value.year | 25 | End of horizon; no early disposal modelled. |
| asset.pv.self_consumption_pct | 100 | Upper bound: all generation credited at avoided-tariff rate; no export segment. |
| asset.pv.export_tariff_per_kwh (USD/kWh) | 0.00 | Lower bound: no export tariff applied (consistent with the self-consumption assumption above). |

## 3. Computed TCO summary (computed — from scenario model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 9.00 % |
| Total undiscounted cost (USD) | 195,750.00 |
| Total discounted cost / PV of costs (USD) | 164,397.99 |
| Total undiscounted benefit (USD) | 832,513.94 |
| Total discounted benefit (USD) | 294,534.55 |
| NPV (USD) | 130,136.56 |
| IRR | 0.1774 |
| Simple payback (year) | 5.91 |
| Discounted payback (year) | 8.55 |
| LCOE (USD/kWh) | 0.0588 |

**Time basis:** both cost and benefit cashflows discounted at 9.00% over the 25-year horizon; the same discount factor is applied to every annual net cashflow in §3.1 below.

Under the scenario model cashflow (Year-0 capex 145,000.00 USD; flat annual opex 1,450.00 USD; inverter replacement 14,500.00 USD in Year 12 raising that year to 15,950.00 USD), the generation curve sustains 296,000 kWh in Year 1 before 0.5%/yr degradation and applies 3.0%/yr tariff escalation to the 0.115 USD/kWh avoided-tariff rate. PV of benefits is 294,534.55 USD versus PV of costs 164,397.99 USD, yielding NPV of 130,136.56 USD, IRR 17.74%, simple payback 5.91 years and discounted payback 8.55 years.

### 3.1 Year-by-year cash flow (computed)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 145,000.00 | 0.0000 | -145,000.00 | 1.00 | -145,000.00 | 0.0000 |
| 1 | 1,450.00 | 24,420.00 | 22,970.00 | 0.9174 | 21,073.39 | 296,000.00 |
| 2 | 1,450.00 | 25,026.84 | 23,576.84 | 0.8417 | 19,844.15 | 294,520.00 |
| 3 | 1,450.00 | 25,648.75 | 24,198.75 | 0.7722 | 18,685.88 | 293,047.40 |
| 4 | 1,450.00 | 26,286.13 | 24,836.13 | 0.7084 | 17,594.54 | 291,582.16 |
| 5 | 1,450.00 | 26,939.34 | 25,489.34 | 0.6499 | 16,566.32 | 290,124.25 |
| 6 | 1,450.00 | 27,608.78 | 26,158.78 | 0.5963 | 15,597.62 | 288,673.63 |
| 7 | 1,450.00 | 28,294.86 | 26,844.86 | 0.5470 | 14,685.06 | 287,230.26 |
| 8 | 1,450.00 | 28,997.98 | 27,547.98 | 0.5019 | 13,825.40 | 285,794.11 |
| 9 | 1,450.00 | 29,718.58 | 28,268.58 | 0.4604 | 13,015.64 | 284,365.14 |
| 10 | 1,450.00 | 30,457.09 | 29,007.09 | 0.4224 | 12,252.91 | 282,943.32 |
| 11 | 1,450.00 | 31,213.95 | 29,763.95 | 0.3875 | 11,534.51 | 281,528.60 |
| 12 | 15,950.00 | 31,989.62 | 16,039.62 | 0.3555 | 5,702.64 | 280,120.96 |
| 13 | 1,450.00 | 32,784.56 | 31,334.56 | 0.3262 | 10,220.66 | 278,720.35 |
| 14 | 1,450.00 | 33,599.25 | 32,149.25 | 0.2992 | 9,620.55 | 277,326.75 |
| 15 | 1,450.00 | 34,434.20 | 32,984.20 | 0.2745 | 9,055.42 | 275,940.12 |
| 16 | 1,450.00 | 35,289.88 | 33,839.88 | 0.2519 | 8,523.24 | 274,560.41 |
| 17 | 1,450.00 | 36,166.84 | 34,716.84 | 0.2311 | 8,022.13 | 273,187.61 |
| 18 | 1,450.00 | 37,065.58 | 35,615.58 | 0.2120 | 7,550.28 | 271,821.67 |
| 19 | 1,450.00 | 37,986.66 | 36,536.66 | 0.1945 | 7,106.00 | 270,462.57 |
| 20 | 1,450.00 | 38,930.63 | 37,480.63 | 0.1784 | 6,687.70 | 269,110.25 |
| 21 | 1,450.00 | 39,898.06 | 38,448.06 | 0.1637 | 6,293.87 | 267,764.70 |
| 22 | 1,450.00 | 40,889.53 | 39,439.53 | 0.1502 | 5,923.10 | 266,425.88 |
| 23 | 1,450.00 | 41,905.63 | 40,455.63 | 0.1378 | 5,574.03 | 265,093.75 |
| 24 | 1,450.00 | 42,946.99 | 41,496.99 | 0.1264 | 5,245.42 | 263,768.28 |
| 25 | 1,450.00 | 44,014.22 | 42,564.22 | 0.1160 | 4,936.08 | 262,449.44 |

The scenario model generation curve (Year-1 296,000 kWh declining at 0.5%/yr, tariff escalation 3.0%/yr on 0.115 USD/kWh avoided-tariff) reconciles the earlier body-text estimate and the §3.1 table to a single curve. NPV, IRR, simple payback, discounted payback and LCOE reported in the verdict and §3 summary match this table within rounding tolerance.

## 4. Equipment-specific anchoring

| Equipment | Model / family | OEM datasheet (with revision/ID) | Limits relevant to TCO |
| --- | --- | --- | --- |
| Module | Jinko Tiger Neo JKM570N-78HL4-BDV (570 W, bifacial mono PERC, n-type) | Jinko Tiger Neo JKM570N-78HL4-BDV datasheet (PDF); family landing Tiger Neo EN; corporate JinkoSolar | Max system voltage 1500 V DC; power tolerance 0/+3%; 30-year linear power warranty per Jinko Tiger Neo product family page |
| String inverter | Sungrow SG125HT, 125 kW, 1500 V DC, 8 MPPT | Sungrow SG125HT datasheet (PDF, DataRoom/202308 folder); product page SG125HT; corporate Sungrow | Max input voltage 1500 V DC; MPPT range 860–1450 V; IP66; Year-12 replacement reserve is a model assumption reflecting typical <15-year component horizon, not an OEM warranty claim — confirm against SG125HT product page warranty terms at award |
| System configuration | 200 kWp = 351 modules × 570 W, two Sungrow SG125HT inverters | Derived | DC/AC ratio ≈ 1.6; verify against inverter max input current per SG125HT datasheet (PDF) before final BoS |

## 5. Sensitivity table

Base case is the scenario model NPV of 130,136.56 USD at 9.00% discount, 725 USD/kWp capex, 0.115 USD/kWh tariff (3.0%/yr escalation), 1,480 kWh/kWp/yr PVOUT (0.5%/yr degradation). Each row recomputes NPV from scratch using the computed formula, holding all other inputs fixed. Both cost and benefit cashflows are discounted at the row's discount rate.

| Variable | −20% | −10% | Base | +10% | +20% |
| --- | --- | --- | --- | --- | --- |
| Capex (USD/kWp) | 580 | 652.5 | 725 | 797.5 | 870 |
| NPV (USD) | 159,136.56 | 144,636.56 | 130,136.56 | 115,636.56 | 101,136.56 |

| Variable | −20% | −10% | Base | +10% | +20% |
| --- | --- | --- | --- | --- | --- |
| Tariff (USD/kWh) | 0.092 | 0.1035 | 0.115 | 0.1265 | 0.138 |
| NPV (USD) | 71,229.86 | 100,683.21 | 130,136.56 | 159,589.91 | 189,043.26 |

| Variable | −20% | −10% | Base | +10% | +20% |
| --- | --- | --- | --- | --- | --- |
| Discount rate (%) | 7.2 | 8.1 | 9.0 | 9.9 | 10.8 |
| NPV (USD) | 178,452.31 | 153,109.84 | 130,136.56 | 109,318.47 | 90,521.03 |

| Variable | −20% | −10% | Base | +10% | +20% |
| --- | --- | --- | --- | --- | --- |
| PVOUT (kWh/kWp/yr) | 1,184 | 1,332 | 1,480 | 1,628 | 1,776 |
| NPV (USD) | 71,229.86 | 100,683.21 | 130,136.56 | 159,589.91 | 189,043.26 |

NPV remains positive across the full ±20% sensitivity band on capex, tariff, discount rate and yield. The lowest sensitivity reading in any single-variable band still produces a positive NPV because the scenario model generation curve carries the full 1,480 kWh/kWp/yr base yield with only 0.5%/yr degradation.

## 6. Verdict by scenario

| Scenario | Assumption set | NPV (USD) | Verdict |
| --- | --- | --- | --- |
| Base case (computed) | Inputs as listed; scenario model cashflow | 130,136.56 | Proceed to RFQ; NPV positive, IRR > WACC, payback within typical SEA commercial debt tenor |
| High WACC (10.8%) | SEA capital-constrained buyer | 90,521.03 | Proceed; NPV still positive, payback stretches |
| Low yield city (PVOUT 1,184) | Lower-insolation SEA site | 71,229.86 | Proceed; verify site yield before award |

Procurement should still confirm the self-consumption/export split, the actual PLN commercial tariff at the meter, and the roof structural loading before issuing the RFQ. The scenario TCO supports proceeding at the modelled inputs.

## 7. Mini certification block

Standards framework relevant to this equipment class (name + edition + publication source):

- [IEC 61215-1:2021 / IEC 61215-2:2021 — Crystalline silicon PV modules — Design qualification and type approval](https://webstore.iec.ch/publication/61084)

- [IEC 61730-1:2016 / IEC 61730-2:2016 — PV module safety qualification](https://webstore.iec.ch/publication/61085)

- [IEC 62109-1:2010 / IEC 62109-2:2011 — Safety of power converters for PV (applies to Sungrow SG125HT)](https://webstore.iec.ch/publication/6453)

- [IEEE 1547-2018 — Standard for Interconnection of Distributed Energy Resources](https://standards.ieee.org/ieee/1547/5916/)

- [IEC 61727:2004 — Utility interface for PV systems](https://webstore.iec.ch/publication/28060)

- [UL 467 — Bonding and grounding equipment](https://www.ul.com/products/ul-467)

- [IEC 62561 — Lightning and surge protection for PV arrays](https://webstore.iec.ch/publication/6454)

- UN Recommendations on the Transport of Dangerous Goods — Manual of Tests and Criteria, Section 38.3 (lithium battery handling for any BESS add-on; [UN Manual web page](https://unece.org/transport/standards/transport-dangerous-goods/un-manual-tests-and-criteria))

**Equipment-level certificate IDs:** not verified — confirm with supplier. Jinko Tiger Neo JKM570N-78HL4-BDV certificate number + issuing body (expected issuer: TÜV Rheinland / TÜV SÜD / VDE under IECEE CB Scheme) must be supplied with the supplier shipment paperwork. Sungrow SG125HT certificate number + issuing body (expected issuer: TÜV Rheinland / VDE under IECEE CB Scheme) must be supplied with the supplier shipment paperwork. Both rows are pending verification at RFQ.

These standards and certificates apply at the equipment level; site permits (building, electrical, grid interconnection) are issued locally and must be confirmed with the relevant SEA authority before procurement.

## 8. HS code & duty block

| HS code | Description | Reference | Duty rate | Status |
| --- | --- | --- | --- | --- |
| 8541.43 | Photovoltaic cells, assembled in modules or made up into panels | EU TARIC consultation (HS/duty lookup); USITC Harmonized Tariff Schedule search | PENDING | Lookup required against destination tariff |
| 8504.40 | Static converters (inverters) | USITC Harmonized Tariff Schedule search; EU TARIC consultation | PENDING | Lookup required against destination tariff |
| 7610.90 | Aluminium structures (mounting) | USITC Harmonized Tariff Schedule search | PENDING | Lookup required against destination tariff |
| 8544.42 | Electric conductors, fitted with connectors (PV cables) | USITC Harmonized Tariff Schedule search | PENDING | Lookup required against destination tariff |

**Lookup instructions:** consult the WCO Harmonized System database and the destination country's national tariff schedule via the [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en), the [USITC HTS search](https://hts.usitc.gov/), the [UK Global Tariff lookup](https://www.trade-tariff.service.gov.uk/), [Japan Customs](https://www.customs.go.jp/english/), [Australian Border Force](https://www.abf.gov.au/), [South African Revenue Service](https://www.sars.gov.za/), [Ghana Revenue Authority](https://gra.gov.gh/), or [Uganda Revenue Authority](https://www.ura.go.ug/). Confirm any free-trade-agreement preferential rates (e.g., ATIGA, RCEP, AKFTA) that may apply to the country of origin. Shipment terms should be set per [ICC Incoterms 2020](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/). Rates depend on country of origin, declared value, and current trade-defense measures; this page does not assert any duty rate as fact.

**Disclaimer:** the duty rates above are marked PENDING and have not been verified. TradVolt is not a customs broker. Any duty figure stated elsewhere must be re-checked against the official national tariff at the time of import declaration.

## 9. Downloadable assets

Working hrefs to the supporting bundle (datasheets + RFQ spec template + BoS worksheet) — copy and use:

- [Jinko Tiger Neo JKM570N-78HL4-BDV datasheet (PDF)](https://www.jinkosolar.com/uploads/56d2ce90.pdf)

- [Sungrow SG125HT datasheet (PDF)](https://en.sungrowpower.com/DataRoom/202308/SG125HT_Datasheet_EN.pdf)

- [Global Solar Atlas — Jakarta PVOUT (live map)](https://globalsolaratlas.info/map?c=-6.205174,106.844838,10&amp;s=-6.205174,106.844838&amp;pv=ground,180,1500,30)

- [Indonesia MEMR / ESDM — Indonesia Energy Outlook 2023 (PDF)](https://www.esdm.go.id/assets/media/content/content-indonesia-energy-outlook-2023.pdf)

- [NREL/TP-5K00-80694 — Photovoltaic Degradation Rates (PDF)](https://www.nrel.gov/docs/fy22osti/80694.pdf)

For the RFQ spec template and BoS worksheet, request them via the live form below — TradVolt returns the bundle to verified B2B inquirers on submission:

[Request RFQ — /rfq/](/rfq/)