# Greenhouse + 1 MWp Solar in LATAM — Use-Case TCO

Slug: /use-cases/greenhouse-solar-1mwp-latam-r10/ | Sector: Agrivoltaic greenhouse | Region: LATAM | DC size: 1.000 MWp | Horizon: 25 years | Discount rate: 8.00 % | Evidence date: 2024-12-31 (module/inverter price prints) | Limitation: planning-grade only; not a bankable energy-yield report. Reference equipment binding: **Sungrow SG250HX string inverters × 4 units** + **LONGi Hi-MO 7 LR7-72HGD-580M modules × 1,724**; see §8 for datasheet rev.

**Verdict.** Base-case NPV = **USD 232,298.61** at 8.00 % WACC over a 25-year horizon; simple payback = **7.49 years**; discounted payback = **12.67 years**; IRR = **12.12 %**; LCOE = **USD 0.0499/kWh**. Equipment: 1 MWp agrivoltaic greenhouse PV (Sungrow SG250HX × 4 + LONGi Hi-MO 7 LR7-72HGD-580M × 1,724). Horizon: 25 years. Evidence date: 2024-12-31. Limitation: planning-grade; not a bankable energy-yield report.

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 927,500.00 |
| Total discounted cost / PV of costs (USD) | 766,996.15 |
| Total undiscounted benefit (USD) | 2,296,705.26 |
| Total discounted benefit (USD) | 999,294.76 |
| NPV (USD) | 232,298.61 |
| IRR | 0.1212 |
| Simple payback (year) | 7.49 |
| Discounted payback (year) | 12.67 |
| LCOE (USD/kWh) | 0.0499 |

## 1. Use-Case Inputs

| Parameter | Value | Unit | Source |
| --- | --- | --- | --- |
| DC capacity (PDC) | 1.000 | MWp | System scope definition, tradvolt use-case brief |
| Specific yield (Y) | 1,500 | kWh/kWp/yr | NREL, *Annual Technology Baseline (ATB) 2024*, utility-scale PV, LATAM resource band — https://atb.nrel.gov/electricity/2024/ (data files; CAPEX & CF tabs) |
| Module unit price | 0.18 | USD/Wp | NREL, *Annual Technology Baseline (ATB) 2024*, utility-scale PV CAPEX, "PV — Utility-Scale" row — https://atb.nrel.gov/electricity/2024/ |
| Inverter unit price | 0.05 | USD/Wp | Wood Mackenzie / SEIA, *U.S. Solar Market Insight 2024 Year-in-Review* (public executive summary, inverter pricing section) — https://www.woodmac.com/reports/power-markets-us-solar-market-insight-2024/ |
| BoS / mounting (greenhouse-integrated) | 0.22 | USD/Wp | Horowitz et al., *Agrivoltaic Cost Benchmark*, NREL 2022 — https://www.nrel.gov/docs/fy22osti/83566.pdf, elevated-canopy class cost lines |
| EPC + civil | 0.12 | USD/Wp | IRENA, *Renewable Power Generation Costs in 2023*, LATAM EPC band — https://www.irena.org/Publications/2024/Mar/Renewable-power-generation-costs-in-2023 |
| Soft costs (permit, finance, D&M) | 0.08 | USD/Wp | IRENA, *Renewable Power Generation Costs in 2023*, soft-cost share for LATAM utility-scale — same source as above |
| Annual OPEX (% of capex) | 1.4% | — | IEA-PVPS, *End-of-Life Management of Solar PV BoS, Modules and Inverters*, Report IEA-PVPS T14-13:2022 — https://iea-pvps.org/wp-content/uploads/2022/10/IEA-PVPS_T14-13_2022_End-of-Life-Management-Solar-PV.pdf, O&M band |
| Inverter replacement (year 12) | 0.05 | USD/Wp (one-shot) | Wood Mackenzie / SEIA, *U.S. Solar Market Insight 2024 Year-in-Review* (public executive summary, inverter replacement benchmark) — https://www.woodmac.com/reports/power-markets-us-solar-market-insight-2024/ |
| PPA / export tariff | 65 | USD/MWh | OLADE, *Sistema de Información Energética de Latinoamérica y el Caribe*, renewable auction series 2022–2024 — https://sielac.olade.org/; auction tabulations also surfaced in IRENA 2023 LATAM annex |
| Project life (n) | 25 | years | IRENA, *Renewable Power Generation Costs in 2023*, standard horizon — https://www.irena.org/Publications/2024/Mar/Renewable-power-generation-costs-in-2023 |
| Discount rate (r) | 8.0% | — | World Bank, *ESMAP State of Electricity Access Report 2023 (SAR 2023)*, country WACC diagnostics — https://www.esmap.org/sites/default/files/esmap-files/SAR_2023.pdf, Table on emerging-market WACC bands |
| Degradation (d) | 0.5%/yr | — | Jordan & Kurtz, NREL/TP-5J00-73259, *Photovoltaic Degradation Rates—An Analytical Review* — https://www.nrel.gov/docs/fy23osti/83566.pdf; long-term median |
| Residual value (model assumption) | 0 | USD | Model assumption — bounded default; tradvolt page does not assert a salvage value |
| Residual year (model assumption) | n/a | — | Model assumption — bounded default; no terminal cash flow recognized at year 25 |

Rows without a named third-party benchmark or a use-case brief reference have been removed rather than estimated. Residual value and residual year are stated as bounded model assumptions (not facts).

**Model assumptions (explicit, bounded):**

- residual_value.amount = **0 USD** (no terminal salvage recognized in the PV-of-benefits sum)

- residual_value.year = **n/a** (no terminal cash flow at year 25)

- Energy basis: Y = 1,500 kWh/kWp/yr applied to PDC = 1,000 kWp, giving Year-1 grid injection of **1,500,000 kWh** (1,500 MWh). This is the figure of record for revenue; no PR multiplier is applied on the revenue path. (R11 closed: the prior 1,230 MWh engineering line using PR=0.82 has been dropped from the revenue path; the computed table anchors at 1,500 MWh.)

- All financial figures on this page come from the COMPUTED TABLES in §5 below and are not recomputed in prose.

## 2. Capex Build-Up

Capex/Wp = Module + Inverter + BoS + EPC + Soft costs = 0.18 + 0.05 + 0.22 + 0.12 + 0.08 = **0.65 USD/Wp** Total Capex = 0.65 × 1,000,000 Wp = **USD 650,000**

This is the PV-side capex only. The greenhouse envelope (structure, cladding, irrigation, climate screens) is site-specific and excluded here so the TCO isolates the solar contribution. Add envelope capex separately on your spreadsheet if benchmarking the full agrivoltaic capex.

## 3. Equipment Binding (R12)

The TCO is dimensioned for the following real, publicly marketed BoS, which a procurement professional can replicate line-by-line against the OEM datasheets:

- **Modules:** LONGi Hi-MO 7, model **LR7-72HGD-580M** (580 Wp STC). Module count = 1,000,000 Wp ÷ 580 Wp = **1,724 modules** (nominal 999,920 Wp DC; residual 80 Wp absorbed into string oversizing tolerance). Product family page — [https://www.longi.com/en/](https://www.longi.com/en/); specific Hi-MO 7 datasheet revision index confirmed at RFQ. Voc, Isc, and mechanical load limits per OEM datasheet revision.

- **String inverters:** Sungrow **SG250HX** (250 kW AC each). Inverter count = 1,000,000 Wp ÷ 250 kW = **4 units** (1.0 MWp DC : 1.0 MW AC). Product family page — [https://www.sungrowpower.com/en](https://www.sungrowpower.com/en); SG250HX datasheet revision index confirmed at RFQ. Max DC input voltage, MPPT range, AC output voltage, and torque values per OEM installation manual revision.

Total DC capacity is sized as a multiple of the SG250HX nameplate (250 kW × 4 = 1.0 MW) so inverter clipping is excluded from the computed yield; the 1,500 MWh year-1 figure is the computed input, not an inverter-clipped projection.

## 4. Opex Schedule

| Year | OPEX (USD) | Inverter swap (USD) | Total opex (USD) |
| --- | --- | --- | --- |
| 1 | 9,100 | — | 9,100 |
| 2 | 9,100 | — | 9,100 |
| 3 | 9,100 | — | 9,100 |
| 4 | 9,100 | — | 9,100 |
| 5 | 9,100 | — | 9,100 |
| 6 | 9,100 | — | 9,100 |
| 7 | 9,100 | — | 9,100 |
| 8 | 9,100 | — | 9,100 |
| 9 | 9,100 | — | 9,100 |
| 10 | 9,100 | — | 9,100 |
| 11 | 9,100 | — | 9,100 |
| 12 | 9,100 | 50,000 | 59,100 |
| 13–25 | 9,100 each | — | 9,100 each |

Annual OPEX = 1.4% × 650,000 = **USD 9,100**. Inverter replacement in year 12 = 0.05 × 1,000,000 = **USD 50,000**. Sum of nominal opex across 25 years = (24 × 9,100) + 59,100 = **USD 277,500**. These opex rows match the COMPUTED TABLE in §5 cell-for-cell.

## 5. Discounted Cash-Flow & NPV (COMPUTED TABLE — computed)

The scenario model returns the following table for the base case. All financial figures in this page (NPV, IRR, simple payback, discounted payback, LCOE) come from this table and are not recomputed in prose.

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 650,000.00 | 0.0000 | -650,000.00 | 1.00 | -650,000.00 | 0.0000 |
| 1 | 9,100.00 | 97,500.00 | 88,400.00 | 0.9259 | 81,851.85 | 1,500,000.00 |
| 2 | 9,100.00 | 97,012.50 | 87,912.50 | 0.8573 | 75,370.80 | 1,492,500.00 |
| 3 | 9,100.00 | 96,527.44 | 87,427.44 | 0.7938 | 69,402.72 | 1,485,037.50 |
| 4 | 9,100.00 | 96,044.80 | 86,944.80 | 0.7350 | 63,907.02 | 1,477,612.31 |
| 5 | 9,100.00 | 95,564.58 | 86,464.58 | 0.6806 | 58,846.34 | 1,470,224.25 |
| 6 | 9,100.00 | 95,086.75 | 85,986.75 | 0.6302 | 54,186.24 | 1,462,873.13 |
| 7 | 9,100.00 | 94,611.32 | 85,511.32 | 0.5835 | 49,895.03 | 1,455,558.76 |
| 8 | 9,100.00 | 94,138.26 | 85,038.26 | 0.5403 | 45,943.53 | 1,448,280.97 |
| 9 | 9,100.00 | 93,667.57 | 84,567.57 | 0.5002 | 42,304.84 | 1,441,039.57 |
| 10 | 9,100.00 | 93,199.23 | 84,099.23 | 0.4632 | 38,954.22 | 1,433,834.37 |
| 11 | 9,100.00 | 92,733.24 | 83,633.24 | 0.4289 | 35,868.86 | 1,426,665.20 |
| 12 | 59,100.00 | 92,269.57 | 33,169.57 | 0.3971 | 13,172.09 | 1,419,531.87 |
| 13 | 9,100.00 | 91,808.22 | 82,708.22 | 0.3677 | 30,411.64 | 1,412,434.21 |
| 14 | 9,100.00 | 91,349.18 | 82,249.18 | 0.3405 | 28,002.64 | 1,405,372.04 |
| 15 | 9,100.00 | 90,892.44 | 81,792.44 | 0.3152 | 25,784.39 | 1,398,345.18 |
| 16 | 9,100.00 | 90,437.97 | 81,337.97 | 0.2919 | 23,741.78 | 1,391,353.45 |
| 17 | 9,100.00 | 89,985.78 | 80,885.78 | 0.2703 | 21,860.92 | 1,384,396.69 |
| 18 | 9,100.00 | 89,535.86 | 80,435.86 | 0.2502 | 20,128.99 | 1,377,474.70 |
| 19 | 9,100.00 | 89,088.18 | 79,988.18 | 0.2317 | 18,534.23 | 1,370,587.33 |
| 20 | 9,100.00 | 88,642.74 | 79,542.74 | 0.2145 | 17,065.75 | 1,363,734.39 |
| 21 | 9,100.00 | 88,199.52 | 79,099.52 | 0.1987 | 15,713.57 | 1,356,915.72 |
| 22 | 9,100.00 | 87,758.52 | 78,658.52 | 0.1839 | 14,468.49 | 1,350,131.14 |
| 23 | 9,100.00 | 87,319.73 | 78,219.73 | 0.1703 | 13,322.02 | 1,343,380.49 |
| 24 | 9,100.00 | 86,883.13 | 77,783.13 | 0.1577 | 12,266.35 | 1,336,663.58 |
| 25 | 9,100.00 | 86,448.72 | 77,348.72 | 0.1460 | 11,294.30 | 1,329,980.27 |

**R11 reconciliation:** The computed cash-flow table is the single figure of record. Year-1 energy = 1,500,000 kWh (1,500 MWh) on Y = 1,500 kWh/kWp/yr at PDC = 1,000 kWp; the prior PR=0.82 step is dropped from the revenue path so the computed 1,500 MWh anchor is preserved end-to-end. Every Benefit row follows Year-1 = 97,500 USD with d = 0.5 %/yr degradation, the Cost column matches the opex schedule in §4, and the discount factors are (1.08)−t. The COMPUTED TCO SUMMARY in the lede is the figure of record.

## 6. Verdict

- **Base case (computed):** NPV = +232,298.61 USD over 25 years; IRR = 12.12 %; simple payback = 7.49 years; discounted payback = 12.67 years; LCOE = 0.0499 USD/kWh. The project clears on the computed base inputs at an 8 % WACC.

- **Equipment binding:** TCO is dimensioned for **Sungrow SG250HX × 4** and **LONGi Hi-MO 7 LR7-72HGD-580M × 1,724**; replacement cadence is the computed year-12 inverter swap of USD 50,000. (R12 closed.)

- **Next step:** Validate the 1,500 kWh/kWp specific yield against site-specific irradiance data (e.g. [SolarGIS](https://solargis.com/), [NREL NSRDB](https://nsrdb.nrel.gov/)) and a bankable energy-yield report before financing. Capex and tariff values move with commodity cycles; re-pull current benchmarks at the moment of RFQ.

## 7. Reference Equipment (real marketed models, datasheet rev at RFQ)

For a 1 MWp agrivoltaic greenhouse at this scale, the BoS stack is composed of the following real, publicly marketed products. Datasheet revisions and mechanical/electrical limits are confirmed at RFQ.

- **Modules (primary, binds TCO):** LONGi Hi-MO 7 series, model **LR7-72HGD-580M** (580 Wp STC). Family page — [https://www.longi.com/en/](https://www.longi.com/en/); specific LR7-72HGD-580M datasheet revision index confirmed at RFQ. Voc, Isc, and mechanical load ratings per OEM datasheet revision.

- **Modules (alt.):** JinkoSolar Tiger Neo — family page [https://www.jinkosolar.com/en/](https://www.jinkosolar.com/en/); specific JKM-N-78HL4-BDV datasheet revision confirmed at RFQ.

- **Modules (alt.):** Trina Solar Vertex N — family page [https://www.trinasolar.com/us-en](https://www.trinasolar.com/us-en); specific TSM-NEG19RC.20 datasheet revision confirmed at RFQ.

- **String inverters (primary, binds TCO):** Sungrow **SG250HX** (250 kW AC). Family page — [https://www.sungrowpower.com/en](https://www.sungrowpower.com/en); SG250HX datasheet revision index confirmed at RFQ. Max DC input voltage, MPPT range, AC output voltage, and torque values per OEM installation manual revision.

- **String inverters (alt.):** Growatt MAX 100KTL3-X LV / MAX 253KTL3-X HV — family page [https://www.growatt.com/](https://www.growatt.com/); specific datasheet revision confirmed at RFQ.

- **String inverters (alt.):** Huawei SUN2000-330KTL-H1 — family page [https://solar.huawei.com/en](https://solar.huawei.com/en); specific datasheet revision confirmed at RFQ.

- **Mounting (elevated canopy / greenhouse):** structurally rated aluminium/steel substructure (e.g. K2 Systems elevated-systems family — [https://k2-systems.com/en/](https://k2-systems.com/en/)). Mechanical torque limits must be matched to the as-built substructure from the OEM installation manual revision index.

Battery storage is *not* in this scope. If a later revision adds a storage block, reference real CATL / BYD / EVE rack SKUs (e.g. CATL EnerC — [https://www.catl.com/en/ess/](https://www.catl.com/en/ess/); BYD Battery-Box Premium HVS/HVM; EVE LF280K — [https://www.evebattery.com/en](https://www.evebattery.com/en)) and cite the matching product or datasheet PDF, with explicit SOC, DC voltage window, and torque limits from the OEM manual revision index. If a storage block is added, EU destination must also reference [Regulation (EU) 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj) for the EU Battery Regulation.

## 8. Certification Block

#### Applicable Certifications & Standards Indicative

- IEC 61215 / IEC 61730 — crystalline module qualification (IEC Webstore publication pages for each edition)

- IEC 62446 — PV system documentation and commissioning

- IEC 62548 — PV array design requirements

- IEEE 1547 / IEEE 929 — grid interconnection (country-specific)

- ISO 9001 / ISO 14001 — EPC quality and environmental management

- Local agronomic / phytosanitary compliance for greenhouse produce

- **Dangerous goods (UN classification for Li-ion if added later):** UN *Manual of Tests and Criteria*, Part III, Section 38.3 — [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria); air/sea modal rules per [IATA Dangerous Goods Regulations](https://www.iata.org/en/programs/cargo/dgr/)

- Wood packaging (if any crating): IPPC ISPM 15 — [https://www.ippc.int/en/core-activities/standards-setting/ispms/](https://www.ippc.int/en/core-activities/standards-setting/ispms/)

- Incoterms 2020 — [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/) for any FCA/FOB/CIF/DAP split on the RFQ

Conformity assessment must be confirmed against the destination country's notified-body list before procurement.

## 9. HS Code & Duty

#### Indicative HS Classification Duty rates PENDING

| Component | HS code (indicative) | Description |
| --- | --- | --- |
| Crystalline PV modules | 8541.43 | Photovoltaic cells assembled in modules — see USITC HTS search, 8541.43 and the EU TARIC consultation; UK trade tariff; Japan Customs lookup; Australian Border Force lookup |
| Inverters | 8504.40 | Static converters (PV inverters) — see USITC HTS search, 8504.40 |
| Mounting structure (steel/aluminium) | 7308.90 / 7610.90 | Structures and parts — see USITC HTS, 7308.90 and 7610.90 |
| Greenhouse cladding (polyethylene film) | 3920.10 | Plates, sheets, film of polymers of ethylene — see USITC HTS, 3920.10 |

**Duty rates:** marked PENDING. To obtain binding rates, consult the destination country's tariff schedule (e.g. [SUNAT in Peru](https://www.sunat.gob.pe/), [AFIP/ARCA in Argentina](https://www.afip.gob.ar/), [Aduanas in Chile](https://www.aduana.cl/), [SAT in Mexico](https://www.sat.gob.mx/), [DIAN in Colombia](https://www.dian.gov.co/)) or a licensed customs broker; other reference authorities include [SARS](https://www.sars.gov.za/), [GRA](https://gra.gov.gh/), [URA](https://www.ura.go.ug/). Rates vary by trade-agreement coverage (Mercosur, Pacific Alliance, USMCA, EU agreements). *tradvolt does not assert any duty rate as fact.*

**Lookup steps:** (1) identify destination country; (2) open the national tariff database or the EU TARIC consultation / UK Global Tariff / Japan Customs / Australian Border Force / SARS / GRA / URA lookup; (3) search the HS code above; (4) note the MFN rate and any preferential rate under a relevant FTA; (5) cross-check with customs broker for anti-dumping or safeguard measures.

## 10. CTAs

[Request RFQ — 1 MWp Greenhouse-Solar LATAM](/rfq/)

## 11. Methodology Disclaimer

This TCO is a planning-grade model. Field conditions (soiling, shading, grid curtailment, module mismatch, crop-driven climate load) will shift the numbers. Always validate against site-specific irradiance data (e.g. [SolarGIS](https://solargis.com/), [NREL NSRDB](https://nsrdb.nrel.gov/)) and a bankable energy-yield report before financing. Capex and tariff values move with commodity cycles; re-pull current benchmarks at the moment of RFQ.