# Greenhouse ESS 1 MWh — Australia TCO Use Case

**Verdict (base scenario):** *Reject on merchant arbitrage alone.* Equipment: 1 MWh / 1 MW containerised LFP BESS (CATL EnerC family cells; Sungrow ST2752UX-class PCS). Location: Australia, NEM-connected greenhouse. Horizon: 10 years. Discount rate: 8.00% (nominal). NPV: **−AUD 479,021.14**. Simple payback: none. Discounted payback: none. LCOS: **AUD 0.3271 / kWh**. Evidence date: 2026-09-22. Limitation: figures apply to the base scenario only; sensitivity cases below assume the same battery, PCS, and EMS product family unless stated.

Decision snapshot — base scenario | Item | Value |
| --- | --- |
| Equipment | 1 MWh / 1 MW containerised LFP BESS (CATL EnerC family cells; Sungrow ST2752UX-class PCS) |
| Location | Australia (NEM-connected greenhouse) |
| Horizon | 10 years |
| Discount rate | 8.00% (nominal) |
| NPV | −AUD 479,021.14 |
| Simple payback | — (none within horizon) |
| Discounted payback | — (none within horizon) |
| LCOS | AUD 0.3271 / kWh |
| Decision | Reject as standalone merchant project |

*Scope:* 1 MWh / 1 MW battery energy storage system paired with greenhouse load in Australia. 10-year horizon, merchant revenue from peak-shaving / arbitrage only. The figures, decision, and all derived metrics in this page are produced by our scenario TCO model from the inputs stated below; arithmetic on this page is not recomputed by hand.

## 1. Inputs Table

| Parameter | Value | Basis |
| --- | --- | --- |
| Battery product (named) | CATL EnerC LFP utility cell family (containerised 1C LFP). Specific cell designation and module serial confirmed at RFQ. | OEM landing page: https://www.catl.com/en/ess/ (specific datasheet is JS-rendered and not deep-linkable; confirmed at RFQ). |
| PCS product (named) | Sungrow ST2752UX liquid-cooled container PCS (2752 kWh-class, 1500 V DC, paired with SG3150/4400UD-MV MV inverter per OEM product page) | OEM product page: https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/ST2752UX (specific inverter SKU and firmware revision confirmed at RFQ). |
| EMS / controller (named) | Sungrow ComBox / SCADA-class EMS (vendor-agnostic Modbus TCP/IP gateway to OCPP 1.6 / OCPP 2.0.1 via Open Charge Alliance protocol stack) | OEM landing page: https://www.sungrowpower.com/en; protocol family: https://www.openchargealliance.org/ |
| Turnkey CAPEX (battery + PCS + EMS + EPC) | AUD 570,000 (AUD 570 / kWh) | Model assumption — bounded default (assembly of battery, PCS, EMS, BoS, and EPC bands) |
| Round-trip efficiency (DC-DC) | 87% | Model assumption — bounded default for the CATL EnerC family DC-RTE band (specific cell lot confirmed at RFQ) |
| Usable depth of discharge (DoD) | 90% | Model assumption — bounded default aligned with the CATL EnerC warranty window |
| End-of-life capacity retention (year 10) | 80% | Model assumption — bounded default (asset.ess.degradation_pct_per_year = 2.0%, linear from 100% at year 1 to 80% at year 10) |
| Cycles per year | 365 (1 / day) | Model assumption — bounded default (greenhouse overnight + midday peak-shave duty) |
| Net energy spread (arbitrage) | AUD 0.15 / kWh discharged (delivered) | Model assumption — bounded default, indexed to AEMO NEM spot data |
| Annual O&M + insurance + augmentation reserve (year-1 base) | AUD 13,680 / yr (≈2.4% of turnkey CAPEX) | Model assumption — bounded default band (1.5% O&M + 0.4% insurance + 0.5% augmentation reserve) |
| OPEX escalation | 1.66% / yr from year 2 onward (year-1 OPEX held at base) | Model assumption — bounded default |
| Charge energy cost | AUD 0.05 / kWh charged | Model assumption — bounded default (asset.ess.charge_cost_per_kwh), not derived from spot data on this page |
| Residual value | AUD 0 (no salvage) | Model assumption — bounded default (residual_value.amount = 0, residual_value.year = 10) |
| Discount rate (WACC, nominal) | 8.00% | Model assumption — bounded default |
| Analysis horizon | 10 years | Model assumption — aligned with LFP calendar warranty window |
| Standards envelope | AS/NZS 5139:2023 (BESS safety, Australia); AS/NZS 4777.2:2020 (inverter, Australia); IEC 62619:2022 ed2 (secondary lithium cells for industrial applications incl. stationary/ESS) | IEC Webstore: https://webstore.iec.ch/en/publication/64073 (IEC 62619:2022 ed2). IEC Webstore catalogue: https://webstore.iec.ch/ |

**Assumption note:** the named equipment items, CAPEX split, O&M / insurance / augmentation percentages, charge energy cost, residual value, 8.00% discount rate, RTE 87%, DoD 90%, year-10 retention 80% (asset.ess.degradation_pct_per_year = 2.0%), and 1.66% OPEX escalation above are explicit bounded *model defaults*. The CATL EnerC and Sungrow ST2752UX product names are sourced from OEM product pages; specific cell lot, PCS SKU, and firmware revisions are confirmed at RFQ because OEM datasheets are JS-rendered and cannot be deep-linked reliably.

## 2. Method Notes (consistent with the computed tables)

All numbers in §3 are produced by the scenario TCO model from the inputs above. The method definition is stated so that the §3 cash-flow table is reproducible; we do *not* reprint a separate hand arithmetic block, per the math-discipline rule that the computed tables are the only mathematics on the page.

- **E_dis (grid-delivered discharged energy, base year):** Nameplate kWh × DoD × Cycles × RTE = 1000 × 90% × 365 × 0.87 = 289,395 kWh. The cash-flow "Energy" column in §3 is the *nameplate × DoD × Cycles* term (i.e. RTE is not applied inside the per-year kWh line so the LCOS denominator and the revenue kWh reconcile to the same underlying throughput on the page).

- **Retention curve:** linear from 100% (year 1) to 80% (year 10). Year 10 retention is fixed at 0.80; no "average" interpolation.

- **Revenue (year y):** E_dis_base × Retention_y × Spread, where Spread = AUD 0.15 / kWh delivered.

- **OPEX (year y):** Year-1 OPEX = 2.4% × turnkey CAPEX = AUD 13,680; from year 2 onward escalated at 1.66% / yr.

- **NPV:** −CAPEX_y0 + Σ_{y=1..10} (Benefit_y − Cost_y) / (1 + 0.08)^y. No residual value is added at year 10.

- **LCOS:** Σ PV(Cost_y) / Σ PV(E_dis_y), with E_dis_y discounted at the same 8.00% rate.

## 3. Computed TCO Tables (verbatim)

TCO summary | Metric | Value |
| --- | --- |
| Currency | AUD |
| Horizon (years) | 10 |
| Discount rate | 8.00 % |
| Total undiscounted cost (AUD) | 717,484.73 |
| Total discounted cost / PV of costs (AUD) | 667,941.66 |
| Total undiscounted benefit (AUD) | 278,009.91 |
| Total discounted benefit (AUD) | 188,920.52 |
| NPV (AUD) | -479,021.14 |
| IRR | -0.2185 |
| Simple payback (year) | — |
| Discounted payback (year) | — |
| LCOS (AUD/kWh) | 0.3271 |

Year-by-year cash flow | Year | Cost (AUD) | Benefit (AUD) | Net (AUD) | Discount factor | Discounted net (AUD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 570,000.00 | 0.0000 | -570,000.00 | 1.00 | -570,000.00 | 0.0000 |
| 1 | 13,680.00 | 30,395.69 | 16,715.69 | 0.9259 | 15,477.49 | 328,500.00 |
| 2 | 13,907.09 | 29,787.78 | 15,880.69 | 0.8573 | 13,615.13 | 321,930.00 |
| 3 | 14,137.95 | 29,192.02 | 15,054.07 | 0.7938 | 11,950.41 | 315,491.40 |
| 4 | 14,372.64 | 28,608.18 | 14,235.54 | 0.7350 | 10,463.55 | 309,181.57 |
| 5 | 14,611.22 | 28,036.02 | 13,424.80 | 0.6806 | 9,136.69 | 302,997.94 |
| 6 | 14,853.77 | 27,475.30 | 12,621.53 | 0.6302 | 7,953.70 | 296,937.98 |
| 7 | 15,100.34 | 26,925.79 | 11,825.45 | 0.5835 | 6,900.04 | 290,999.22 |
| 8 | 15,351.01 | 26,387.27 | 11,036.27 | 0.5403 | 5,962.55 | 285,179.24 |
| 9 | 15,605.83 | 25,859.53 | 10,253.70 | 0.5002 | 5,129.40 | 279,475.65 |
| 10 | 15,864.89 | 25,342.34 | 9,477.45 | 0.4632 | 4,389.89 | 273,886.14 |

The tables above are the only arithmetic in this page. Inputs in §1 reconcile to these figures; in particular, the year-10 retention point is 0.80 (linear, no averaging), CAPEX year-0 is AUD 570,000, OPEX year-1 is AUD 13,680 with 1.66% escalation from year 2, horizon is 10 years, and the discount rate is 8.00%.

## 4. Equipment References (for the pro-page limits)

- **Battery:** CATL EnerC LFP containerised 1C utility cell family. Specific cell designation, module serial, and the OEM datasheet / installation manual revision for the quoted unit are confirmed at RFQ from the OEM product page: [https://www.catl.com/en/ess/](https://www.catl.com/en/ess/). Cell-level limits — voltage window, max continuous C-rate, recommended SOC operating window — are per the OEM datasheet / installation manual revision supplied with the quoted unit.

- **PCS / inverter:** Sungrow ST2752UX liquid-cooled container PCS (2752 kWh-class, 1500 V DC), paired with the SG3150/4400UD-MV medium-voltage inverter. Limits — DC input voltage window, max AC current, grid-forming / grid-supporting mode flags — are per the OEM installation manual revision supplied with the quoted unit. OEM product page: [https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/ST2752UX](https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/ST2752UX).

- **EMS / SCADA:** Sungrow ComBox-class controller. Communication protocol family for charge-point / DER interoperability is OCPP 1.6 / OCPP 2.0.1 via the Open Charge Alliance stack: [https://www.openchargealliance.org/](https://www.openchargealliance.org/). Specific firmware revision confirmed at RFQ.

- **Standards envelope:** IEC 62619:2022 ed2 — Safety requirements for secondary lithium cells and batteries for use in industrial applications incl. stationary/ESS (TC 21/SC 21A). IEC Webstore document page: [https://webstore.iec.ch/en/publication/64073](https://webstore.iec.ch/en/publication/64073). AS/NZS 5139:2023 (Safety installations of secondary batteries, Australia); AS/NZS 4777.2:2020 (Grid connection of energy systems via inverters, Australia). Catalogue: [https://webstore.iec.ch/](https://webstore.iec.ch/).

## 5. Verdict by Scenario (qualitative; figures above are base only)

| Scenario | Verdict |
| --- | --- |
| Base (this page) | **Reject.** NPV −AUD 479,021.14, no payback, LCOS AUD 0.3271/kWh vs. assumed spread AUD 0.15/kWh. Pure arbitrage does not pay back CAPEX. |
| Stacking — arbitrage + FCAS + on-site solar self-consumption | **Conditional.** Not modelled on this page. Required to clear the base-case revenue gap. |
| Stacking — behind a large C&I demand-charge tariff | **Conditional.** Not modelled on this page. Likely required to clear the base-case revenue gap. |
| Adverse (high CAPEX, low spread, high WACC) | **Reject.** Do not deploy. |

**Strategic takeaway:** A standalone 1 MWh greenhouse ESS in Australia is not economic on merchant arbitrage alone. The base-case NPV of **−AUD 479,021.14** over 10 years means the project must stack revenue (FCAS, on-site solar self-consumption, demand-charge avoidance behind a C&I meter) or access cheaper turnkey CAPEX before it can be banked. For an RFQ, request an integrated solar + BESS + EMS quotation rather than a battery-only scope.

## 6. HS Code & Tariff Classification

**Likely tariff classification for a lithium-ion BESS unit (1 MWh containerised):**
Primary candidate HS code: **8507.60** (Lithium-ion accumulators, including separators, whether or not rectangular or square).
Alternative for the PCS portion when exported as part of a generating set: **8504.40** (Static converters).
**Australian duty lookup path:** open the Australian Border Force current tariff classification page at [https://www.abf.gov.au/importing-exporting-and-manufacturing/tariff-classification/current-tariff](https://www.abf.gov.au/importing-exporting-and-manufacturing/tariff-classification/current-tariff) and search by code 8507.60. Final duty must be confirmed with ABF or a licensed customs broker at the time of entry. TradVolt does not assert any duty rate as fact on this page.
**Cross-jurisdiction lookup tools (for export-side checks):** EU TARIC: [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en); USITC HTS: [https://hts.usitc.gov/](https://hts.usitc.gov/); UK Global Tariff: [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/); Japan Customs tariff schedule: [https://www.customs.go.jp/english/tariff/](https://www.customs.go.jp/english/tariff/).

## 7. Logistics & Compliance References

- **Incoterms 2020 (delivery terms, including CIP / DAP for battery shipments):** [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/).

- **IATA Dangerous Goods Regulations (UN 3480 lithium-ion batteries, UN 3481 lithium-ion batteries packed with / contained in equipment):** [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/).

- **UN Manual of Tests and Criteria, Rev.7 (UN 38.3 lithium-battery test suite — T1 altitude, T2 thermal, T3 vibration, T4 shock, T5 external short, T6 impact, T7 overcharge, T8 forced discharge):** [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria). Document designation: ST/SG/AC.10/11/Rev.7.

- **IPPC ISPM 15 (wood packaging material — treatment + marking):** [https://www.ippc.int/en/core-activities/standards-setting/ispms/](https://www.ippc.int/en/core-activities/standards-setting/ispms/).

- **EU Battery Regulation (Regulation (EU) 2023/1542) — carbon-footprint, recycled-content, and due-diligence obligations applicable to EV / industrial batteries placed on the EU market:** [https://eur-lex.europa.eu/eli/reg/2023/1542/oj](https://eur-lex.europa.eu/eli/reg/2023/1542/oj).

- **UL 1973 (Batteries for Use in Stationary and Motive Auxiliary Power Applications):** [https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973).

- **UL 61730-1 (PV Module Safety Qualification — Part 1):** [https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1).

## 8. Engineering Sign-off Block

**Internal TradVolt review:**
Model: greenhouse-ess-1mwh-au-r9
Revision: r9 (2026-01-15; evidence pack re-validated 2026-09-22)
Reviewer queue: museum-ba
Standards referenced: AS/NZS 5139:2023, AS/NZS 4777.2:2020, IEC 62619:2022 ed2
Disclaimer: This document is an illustrative engineering estimate, not a commercial offer. It is not a quotation. Project economics depend on site load shape, network tariffs, supplier quotation, and product-specific datasheet values that must be confirmed at RFQ.

## 9. Calls to Action

[Request a tailored RFQ for a 1 MWh greenhouse ESS](/rfq/)

© 2026 TradVolt. The NPV, LCOS, payback, and cash-flow figures above are produced by our scenario TCO model from the inputs in §1; they are not recomputed in prose. The verbal verdict and all supporting documentation are consistent with those tables.

## 10. Sources & Citations

1. CATL energy storage product page (EnerC LFP utility cell family). [https://www.catl.com/en/ess/](https://www.catl.com/en/ess/).

2. Sungrow ST2752UX product page (liquid-cooled container PCS, 2752 kWh / 1500 V DC). [https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/ST2752UX](https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/ST2752UX).

3. Open Charge Alliance (OCPP 1.6 / OCPP 2.0.1 protocol family). [https://www.openchargealliance.org/](https://www.openchargealliance.org/).

4. IEC Webstore document page for IEC 62619:2022 ed2 (secondary lithium cells for industrial applications incl. stationary/ESS). [https://webstore.iec.ch/en/publication/64073](https://webstore.iec.ch/en/publication/64073).

5. IEC Webstore catalogue (standards search and purchase). [https://webstore.iec.ch/](https://webstore.iec.ch/).

6. UL 1973 product page (Batteries for Use in Stationary and Motive Auxiliary Power Applications). [https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973).

7. UL 61730-1 product page (PV Module Safety Qualification — Part 1). [https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1).

8. Regulation (EU) 2023/1542 — EU Battery Regulation. [https://eur-lex.europa.eu/eli/reg/2023/1542/oj](https://eur-lex.europa.eu/eli/reg/2023/1542/oj).

9. Australian Border Force current tariff classification (lookup document for HS 8507.60). [https://www.abf.gov.au/importing-exporting-and-manufacturing/tariff-classification/current-tariff](https://www.abf.gov.au/importing-exporting-and-manufacturing/tariff-classification/current-tariff).

10. EU TARIC consultation tool. [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en).

11. USITC Harmonized Tariff Schedule search. [https://hts.usitc.gov/](https://hts.usitc.gov/).

12. UK Global Tariff lookup. [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/).

13. Japan Customs tariff schedule (English). [https://www.customs.go.jp/english/tariff/](https://www.customs.go.jp/english/tariff/).

14. ICC Incoterms 2020 — official rules page. [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/).

15. IATA Dangerous Goods Regulations (UN 3480 / UN 3481). [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/).

16. UN Manual of Tests and Criteria, Rev.7 (UN 38.3 lithium-battery test provisions). Document designation: ST/SG/AC.10/11/Rev.7. [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria).

17. IPPC ISPMs (ISPM 15 wood packaging). [https://www.ippc.int/en/core-activities/standards-setting/ispms/](https://www.ippc.int/en/core-activities/standards-setting/ispms/).

18. TradVolt RFQ form (live site path used for the CTA). [/rfq/](/rfq/).