## Verdict (answer-first)

Under the base 10-year, ~1 cycle/day bounded assumption, a ~1 MWh DC-class Li-ion greenhouse BESS in Latin America returns **NPV = -436,461.55 USD** (PV of costs 630,316.72 USD vs. PV of benefits 193,855.17 USD), **discounted payback = None**, **simple payback = None**, **IRR = -0.2044**, **LCOS = 0.3025 USD/kWh**. Equipment verdict: **Sungrow PowerTitan2.0 ST2752UX** liquid-cooled 20-ft container BESS (2,752 kWh stored, 1,500 V DC, operating -30 to 50 &deg;C) paired with the **SG3150/4400UD-MV** PCS ([Sungrow ST2752UX product page](https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/ST2752UX)); reference product family [Sungrow PowerTitan2.0](https://www.sungrowpower.com/en/products/utility-energy-storage-system/powertitan2). Location: Latam (jurisdiction TBD at RFQ). Horizon: 10 yr base. Discount rate: 10.00 %. Evidence date: 2026-09-22. Limitation: financial figures are computed from a single bounded tariff blend and a single demand-charge assumption; substitute the site-specific tariff and demand-charge before commitment. The financial verdict must be re-issued against the chosen OEM's datasheet and the manual revision cited at RFQ; operating limits (DC voltage window, SOC window, lug torque, max C-rate) are not asserted on this page until that manual is bound.

| Metric | Value |
| --- | --- |
| NPV (USD) | -436,461.55 |
| IRR | -0.2044 |
| Discounted payback | None |
| Simple payback | None |
| LCOS (USD/kWh) | 0.3025 |
| PV of costs (USD) | 630,316.72 |
| PV of benefits (USD) | 193,855.17 |
| Horizon | 10 yr |
| Discount rate | 10.00 % |

The financial verdict at the bounded defaults is negative; do not commit capex on bill savings alone without substituting site-specific tariffs and the chosen OEM's datasheet values. The bound OEM equipment verdict is the Sungrow ST2752UX; operating limits (DC voltage window, SOC window, lug torque, max C-rate) must be re-asserted against the OEM's installation and operation manual (revision captured at RFQ).

## 1. Context

A ~1 MWh DC-class lithium-ion battery energy storage system (BESS) sized for a mid-to-large Latin American greenhouse complex can shave demand peaks, ride through grid instability, and back up ventilation and irrigation during outages. This use-case page reports the bill-savings arithmetic and the total cost of ownership (TCO) envelope computed by Tradvolt's scenario TCO model so a procurement or sustainability lead can shortlist a configuration before opening a formal RFQ. The financial figures in &sect;5 are computed and are reproduced verbatim from the model output; no other financial numbers appear on this page.

## 2. Inputs

| Input | Value | Unit | Source / status |
| --- | --- | --- | --- |
| Usable energy capacity (design point) | 1,000 | kWh | Assumption: 1 MWh class design point (financial envelope; physical container is the 2,752 kWh ST2752UX - see &sect;3) |
| Round-trip efficiency (DC, AC-equivalent basis) | 92 | % | Assumption: explicit bounded default industry-wide Li-ion DC band |
| Analysis horizon | 10 | years | Assumption: explicit bounded default |
| Discount rate | 10.00 | % | Assumption: explicit bounded default (Latam emerging-market adjustment) |
| Capex (turnkey, 1 MWh / 1 C, DC) | 550,000 | USD | Assumption: explicit bounded default utility-scale 1 MWh DC capex envelope; bounded by the NREL ATB utility-scale BESS capex band (NREL Annual Technology Baseline) and the IRENA Electricity Storage and Renewables cost database; specific OEM quote captured at RFQ |
| Fixed annual Opex | 1.5 | %/yr of capex | Assumption: explicit bounded default for utility-scale BESS O&M |
| Augmentation allowance (end of year 8) | 10 | % of capex | Assumption: explicit bounded default (Li-ion throughput-driven mid-life top-up) |
| Energy value (blend) | 0.18 | USD/kWh | Assumption: explicit bounded default blend of self-consumption savings and arbitrage spread; name a real tariff schedule at RFQ |
| Demand tariff | 110 | USD/kW-yr | Assumption: explicit bounded default demand charge band; name a real utility tariff (e.g., CFE in Mexico, ENEL Distribuci&oacute;n in Latam) at RFQ |
| Peak demand reduction | 200 | kW | Assumption: derived as 1,000 kWh / 5 h discharge window |
| Annual demand-charge value | 22,000 | USD/yr | Assumption: 200 kW &times; 110 USD/kW-yr at the bounded default demand tariff |
| Equivalent full cycles per year | 1 | cycles/day | Assumption: explicit bounded default |
| Residual value amount | 0 | USD | Assumption: explicit bounded default (no salvage booked) |
| Residual value year | n/a | — | Model assumption: explicit bounded default (no terminal year assigned) |
| ESS charge cost (energy in) | 0.00 | USD/kWh | Model assumption: explicit bounded default; charge cost embedded inside the 0.18 USD/kWh blend in the base case |
| ESS degradation | 2.0 | %/yr (usable-energy derate) | Assumption: explicit bounded default |

Inputs labelled "Assumption: explicit bounded default" or "Model assumption" are model inputs stated for traceability, not sourced facts; they must be replaced by named tariff lines, OEM datasheet values, and site measurements before any commitment.

## 3. Equipment verdict (bound OEM model)

The financial verdict is bound to the **Sungrow PowerTitan2.0 ST2752UX** liquid-cooled 20-ft container BESS paired with the **SG3150/4400UD-MV** PCS. Public product page: [Sungrow ST2752UX product page](https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/ST2752UX). Product family page: [Sungrow PowerTitan2.0](https://www.sungrowpower.com/en/products/utility-energy-storage-system/powertitan2).

Publicly published limits taken from the product page above (current at evidence date 2026-09-22): stored energy **2,752 kWh**; DC bus **1,500 V**; operating ambient **-30 to 50 &deg;C**; container format **20-ft liquid-cooled**; pairing PCS family **SG3150/4400UD-MV**. Per-product power, duration, and cycle-life figures are not published on the ST2752UX product page and must be asserted against the OEM's installation and operation manual (manual title, edition, revision captured at RFQ); operating limits not on the public product page - DC voltage window, SOC window, lug torque, max C-rate - are not asserted on this page until that manual revision is bound.

Candidate alternates in the same ~1 MWh DC turnkey class (each a named, publicly marketed product; sub-model, manual title, and revision to be confirmed at RFQ):

- **CATL EnerC** - 1 MWh container-class DC BESS. OEM reference: [CATL energy storage](https://www.catl.com/en/ess/). Specific sub-model (e.g., EnerC 20-ft container) and manual revision confirmed at RFQ.

- **Huawei Smart String ESS** (container class). OEM reference: [Huawei FusionSolar](https://solar.huawei.com/en). Specific sub-model and manual revision confirmed at RFQ.

- **BYD MC Cube / HVS-class commercial-industrial LFP** (residential/CI rating band; cabinet ratings must be confirmed against the OEM datasheet before any utility-scale claim). OEM reference: [BYD Energy Storage](https://www.bydenergy.com/). Cabinet rating and manual revision confirmed at RFQ.

- **EVE Energy prismatic LFP cells** (cell-level OEM, typically integrated by a pack/system partner). OEM reference: [EVE Energy](https://www.evebattery.com/en). Cell part number and pack-integration manual revision confirmed at RFQ.

## 4. Methodology (one paragraph)

The scenario TCO model integrates Capex, annual Opex (%/yr of capex), a mid-life augmentation allowance (% of capex, incurred at the listed year), and a benefit stream (annual energy-value USD plus annual demand-charge USD), all discounted at the stated rate. The base benefit stream is the single number reproduced in the COMPUTED TABLE &sect;5 as "Benefit (USD)"; the 0.18 USD/kWh blend and 110 USD/kW-yr demand tariff are the bounded defaults behind that stream, with the ESS charge cost already embedded in that blend (charge cost per kWh = 0.00 USD/kWh as an explicit bounded default) and residual value set to 0 USD at no terminal year. The COMPUTED TABLES in &sect;5 are the only mathematics on the page.

## 5. COMPUTED TABLES (verbatim from scenario model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 10 |
| Discount rate | 10.00 % |
| Total undiscounted cost (USD) | 695,335.20 |
| Total discounted cost / PV of costs (USD) | 630,316.72 |
| Total undiscounted benefit (USD) | 310,618.33 |
| Total discounted benefit (USD) | 193,855.17 |
| NPV (USD) | -436,461.55 |
| IRR | -0.2044 |
| Simple payback (year) | — |
| Discounted payback (year) | — |
| LCOS (USD/kWh) | 0.3025 |

Year-by-year cash flow (all figures discounted at 10.00 %; cost stream = capex + annual opex + mid-life augmentation; benefit stream = annual energy-value USD + annual demand-charge USD; single time-basis used for both costs and benefits) | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 550,000.00 | 0.0000 | -550,000.00 | 1.00 | -550,000.00 | 0.0000 |
| 1 | 8,250.00 | 33,960.87 | 25,710.87 | 0.9091 | 23,373.52 | 365,000.00 |
| 2 | 8,415.00 | 33,281.65 | 24,866.65 | 0.8264 | 20,550.95 | 357,700.00 |
| 3 | 8,583.30 | 32,616.02 | 24,032.72 | 0.7513 | 18,056.14 | 350,546.00 |
| 4 | 8,754.97 | 31,963.70 | 23,208.73 | 0.6830 | 15,851.88 | 343,535.08 |
| 5 | 8,930.07 | 31,324.42 | 22,394.36 | 0.6209 | 13,905.14 | 336,664.38 |
| 6 | 9,108.67 | 30,697.94 | 21,589.27 | 0.5645 | 12,186.58 | 329,931.09 |
| 7 | 9,290.84 | 30,083.98 | 20,793.14 | 0.5132 | 10,670.17 | 323,332.47 |
| 8 | 64,476.66 | 29,482.30 | -34,994.36 | 0.4665 | -16,325.13 | 316,865.82 |
| 9 | 9,666.19 | 28,892.65 | 19,226.46 | 0.4241 | 8,153.90 | 310,528.50 |
| 10 | 9,859.51 | 28,314.80 | 18,455.29 | 0.3855 | 7,115.31 | 304,317.93 |

**Closed-form NPV check (sum of discounted net cash flows):** (-550,000.00) + 23,373.52 + 20,550.95 + 18,056.14 + 15,851.88 + 13,905.14 + 12,186.58 + 10,670.17 + (-16,325.13) + 8,153.90 + 7,115.31 = **-436,461.55 USD**, matching the NPV line in the TCO summary table above. A procurement professional can re-verify the NPV by summing the "Discounted net (USD)" column of the year-by-year cash-flow table without trusting the model.

Headline LCOS is computed as the 10-year PV of costs (630,316.72 USD) divided by the discounted kWh stream over the same horizon; LCOS = 0.3025 USD/kWh.

## 6. HS code block with lookup instructions

| HS code (candidate) | Description (working description only) | Duty rate | Lookup path |
| --- | --- | --- | --- |
| 8507.60 | Lithium-ion accumulators, including BESS modules and packs | PENDING — confirm with customs broker | Destination customs authority (e.g., SAT Guatemala, SUNAT Peru, DIAN Colombia, AFIP Argentina, SII Chile); cross-check USITC HTS at hts.usitc.gov; WCO HS Nomenclature 2022 edition via wcoomd.org — HS Nomenclature 2022 |
| 8504.40 | Static converters, including PCS/inverter equipment | PENDING — confirm with customs broker | Same customs authority path; cross-check EU TARIC at ec.europa.eu — TARIC consultation |
| 8537.10 | Boards/panels for electric control, BMS and switchgear assemblies | PENDING — confirm with customs broker | Same customs authority path; cross-check USITC HTS at hts.usitc.gov |

**How to confirm HS classification and duty rate:** (1) Pick the candidate row that best describes each line item (cells vs. PCS vs. BMS/switchgear). (2) Pull the current national tariff schedule from the destination country's customs authority. (3) Cross-check with the latest WTO or regional trade-agreement schedule the country is a party to (Pacific Alliance, Mercosur, EU agreements) for any preferential rate. (4) Confirm the ruling with a licensed customs broker in the destination country before shipping.

**Disclaimer:** No duty rate is asserted as fact on this page; every duty figure is marked PENDING and must be confirmed by a licensed customs broker against the current tariff schedule of the destination country.

## 7. Certification and shipping standards (informational)

| Standard / regulation | Scope | Status for a ~1 MWh greenhouse ESS in Latam |
| --- | --- | --- |
| IEC 62619:2022 ed2 - Safety requirements for secondary lithium cells and batteries for use in industrial applications incl. stationary/ESS (TC 21/SC 21A). Catalogue page: IEC 62619:2022 ed2 (IEC Webstore publication 64073) | Secondary lithium cells for industrial applications | Recommended baseline |
| IEC 63056:2020 - ESS lithium battery safety (to 1500 V DC); HESS/PV/large on-off-grid storage; builds on IEC 62619. Catalogue page: IEC 63056:2020 (IEC Webstore publication 29224) | Stationary lithium-ion battery safety (to 1500 V DC) | Recommended baseline for 1,500 V DC container-class BESS |
| IEC 62485-5:2020 - Safety requirements for secondary batteries and battery installations, Part 5: Safe operation of stationary lithium ion batteries (TC 21). Catalogue page: IEC 62485-5:2020 (IEC Webstore publication 29086) | Safe operation of stationary Li-ion batteries | Recommended baseline for safe operation |
| UL 1973 - Batteries for Use in Stationary and Motive Auxiliary Power Applications. Standard page: shopulstandards.com — UL 1973 | Battery module and pack safety | Recommended baseline, often required by AHJ |
| UL 9540 / UL 9540A (certification scope page: ul.com — ESS testing and certification) | Energy storage system and fire propagation testing | Recommended baseline, often required by AHJ |
| IEEE 1547 | Interconnection | Apply if exporting or operating in grid-forming mode |
| Regulation (EU) 2023/1542 (eur-lex.europa.eu — EU Battery Regulation 2023/1542) | EU battery sustainability, labelling, due diligence | Applies only if the destination is the EU/EEA; informational otherwise |
| UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, &sect;38.3 (lithium battery provisions) — unece.org — UN Manual of Tests and Criteria | Transport classification for lithium batteries | Mandatory for any shipment, including sea and air (IATA DGR references &sect;38.3) |
| IATA Dangerous Goods Regulations (iata.org — DGR programme) | Air freight of lithium batteries (UN 3480/3481) | Apply if any leg is by air |
| IPPC ISPM 15 (ippc.int — ISPMs list) | Wood packaging material treatment | Mandatory for sea-freight packaging |
| Incoterms 2020 (iccwbo.org — Incoterms 2020) | Delivery terms and risk transfer | Select per project (CIF, FOB, DAP, etc.) |
| Local AHJ permit | Civil, electrical, fire | Mandatory before commissioning |

Final certification set is site-specific and must be confirmed with the local authority having jurisdiction (AHJ) and the chosen EPC. The IEC, UL, UN, and IATA references above are the canonical sources; cite the full designation, edition, and revision against the OEM manual and the chosen OEM at RFQ.

## 8. Calls to action

Open a single, focused RFQ for a ~1 MWh greenhouse ESS in Latam: [Request a quote for greenhouse ESS 1 MWh Latam](/rfq/).

Review the assumptions and the COMPUTED TABLES on this page before opening the RFQ; bring your site's named tariff schedule, demand charge, and chosen OEM (Sungrow PowerTitan2.0 ST2752UX bound; CATL EnerC / Huawei Smart String ESS / BYD MC Cube / EVE-class alternates available) so the financial verdict can be re-issued against the selected configuration.