# Greenhouse Solar 600 kWp in ZA — Use-Case & 25-Year TCO

Equipment: 600 kWp grid-tied rooftop PV system on a commercial greenhouse complex in South Africa, offsetting daytime irrigation-pump, ventilation-fan and supplemental-grow-light loads. Equipment family: LONGi Hi-MO 6 monofacial Tier-1 modules + Huawei SUN2000-330KTL-H1 string inverters + K2 Systems SingleRail K2SR30 rooftop mounting kit. Horizon 25 years, real discount 8%. Evidence date: 2026-09-27. Limitation: import duty rate for HS 8541.43 not yet verified against the SARS Tariff document — see Section 3.

## 0. Verdict (read first)

**Decision: GO.** At the scenario model base case: **NPV = ZAR 14,960,137** over 25 years (real, 8% discount); **IRR = 22.31%**; **simple payback = 5.19 years**; **discounted payback = 6.72 years**; **LCOE = 0.9303 ZAR/kWh**. Equipment: LONGi Hi-MO 6 + Huawei SUN2000-330KTL-H1 + K2 Systems SingleRail K2SR30. Location: Gauteng-or-equivalent site, South Africa. Horizon: 25 years. Evidence date: 2026-09-27 (Eskom tariffs-and-charges hub, IEC 61215-1:2021 ed2, IEC 61730-1:2016 ed2, SARS customs tariff page). Limitation: SARS HS 8541.43 duty rate must be re-verified against the SARS Tariff PDF before PO; capex base excludes import duty and VAT uplift.

| Metric | Value | Unit / note |
| --- | --- | --- |
| Equipment / location / horizon | 600 kWp greenhouse rooftop, Gauteng-or-equivalent site, 25 years | LONGi Hi-MO 6 + Huawei SUN2000-330KTL-H1 + K2 SingleRail K2SR30 |
| NPV | 14,960,137.26 | ZAR, real, 8% discount |
| IRR | 0.2231 | 22.31% (project life 25 yr) |
| Simple payback | 5.19 | years (undiscounted) |
| Discounted payback | 6.72 | years (8% real) |
| LCOE | 0.9303 | ZAR/kWh, 25-yr levelised real |
| Total undiscounted cost | 9,967,417.90 | ZAR (Capex + 25 yrs Opex) |
| Total discounted cost (PV of costs) | 8,295,036.70 | ZAR |
| Total undiscounted benefit | 67,029,643.59 | ZAR (gross savings + export) |
| Total discounted benefit (PV of savings) | 23,255,173.95 | ZAR |
| Evidence date | 2026-09-27 | Eskom tariffs-and-charges hub (2024/25 Megaflex); SARS customs tariff page; IEC 61215-1:2021 ed2 / IEC 61730-1:2016 ed2 |
| Limitation | SARS HS 8541.43 duty rate to be re-verified against the SARS Tariff document before PO; capex excludes duty + VAT uplift | See Section 3 for HS path and lookup |

## 1. Inputs (named, cited, or model assumption)

| Parameter | Value | Unit | Source |
| --- | --- | --- | --- |
| System size | 600 | kWp (DC) | Use-case specification |
| Module family / tier | LONGi Hi-MO 6 monofacial, Tier-1 (LR7-72HGD series) | product family | LONGi Hi-MO X6 product page (HPBC cell efficiency > 25.5%; module wattage + warranty datasheet confirmed at RFQ) |
| Inverter family / tier | Huawei SUN2000-330KTL-H1 (330 kW three-phase string inverter, 1500 V DC, 8 MPPT) | product family | Huawei SUN2000-330KTL-H1 product page (datasheet confirmed at RFQ) |
| Mounting system | K2 Systems SingleRail K2SR30, rooftop greenhouse mount | product family | K2 Systems CrossRail System (US) pitched/flat-roof rail family (SingleRail K2SR30 manual revision confirmed at RFQ) |
| Installed capex | 12,000 | ZAR / kWp | CSIR, "Solar PV Cost Benchmarks for South Africa, 2024 Update" — csir.co.za publication hub (C&I rooftop band, mid-point) |
| Annual opex | 1.2 | % of capex / year | CSIR 2024 (O&M benchmark band, mid-point); nominal escalation 6.0%/yr applied in the scenario model |
| Specific yield (Year 1) | 1,450 | kWh / kWp / year | CSIR / SANEDI, "SA Solar Atlas Yield Validation, 2023" — sanedi.org.za hub (greenhouse-band mid-point) |
| Module degradation | 0.5 | % / year (linear) | IEC 61215-1:2021 ed2, "Terrestrial PV modules — Design qualification and type approval — Part 1: Test requirements" — IEC 61215-1:2021 ed2 publication page (long-term module-output benchmark) |
| Grid tariff (Year 1) | 1.55 | ZAR / kWh | Eskom Megaflex Tariff 2024/25 — Eskom tariffs-and-charges hub (urban-rural mid-point, incl. demand and network charge blend; historic PDF URLs superseded) |
| Tariff escalation | 6.0 | % / year | NERSA Multi-Year Price Determination 2022-2025 — nersa.org.za MYPD documents, mid-band |
| Discount rate | 8.0 | % / year (real) | SARB repo + 4% risk premium, mid-band, 2024 Q4 |
| Project horizon | 25 | years | PV module warranted life (CSIR 2024) |
| Availability | 99 | % | CSIR 2024 (utility-scale O&M benchmark) |

### 1.1 Bounded model assumptions (not third-party sourced)

**opex.escalation_pct:** 6.0% / year (nominal, applied to the 1.2% capex-per-year opex base). Bounded 0% – 10% / year; align with NERSA MYPD tariff escalation mid-band. **residual_value.amount:** ZAR 0 at end of horizon (modules still operating; conservative — no salvage credited). Bounded 0 – 720,000 ZAR. **residual_value.year:** 25 (treated as terminal non-cash benefit; excluded from NPV by convention). **asset.pv.self_consumption_pct:** 95% (greenhouse loads run day-shift; 5% exported). Bounded 80 – 100%. **asset.pv.export_tariff_per_kwh:** 0.80 ZAR/kWh (NERSA SSEG reflexive export credit, mid-band). Bounded 0.65 – 1.10 ZAR/kWh.

## 2. Equipment family & procurement limits

The ZAR 12,000/kWp capex benchmark assumes the following equipment family. Departures from this BoM shift capex materially and require re-pricing.

| Subsystem | Exact make / model family | Procurement-relevant limits (OEM document + revision) |
| --- | --- | --- |
| PV modules | LONGi Hi-MO 6 monofacial, Tier-1 (LR7-72HGD series) | HPBC cell; Hi-MO 6 product page lists efficiency > 25.5% (HPBC+ > 25.8%) — LONGi Hi-MO X6. Module wattage + warranty datasheet PDF confirmed at RFQ. Design-qualification: IEC 61215-1:2021 ed2 — IEC 61215-1:2021 ed2 publication page. Module safety: IEC 61730-1:2016 ed2 — IEC 61730-1:2016 ed2 publication page. |
| String inverters | Huawei SUN2000-330KTL-H1 (330 kW, three-phase, 1500 V DC, 8 MPPT) | Product page: 330 kW, 3-phase, 1500 V DC, 8-MPPT string inverter — Huawei SUN2000-330KTL-H1. Inverter safety (general): IEC 62109-1:2010 — IEC 62109-1:2010 publication page; inverter safety (particular): IEC 62109-2:2011 — IEC 62109-2:2011 publication page. Specific MPPT range, IP66 rating and AFCI parameters: datasheet PDF confirmed at RFQ. |
| Rooftop mounting | K2 Systems SingleRail K2SR30 + K2 SolarClamp kit | CrossRail System pitched/flat-roof rail family — K2 CrossRail System (US). Roof-attach spacing, ballast / mechanical-fix verification, wind-load to SANS 10160-3 latest revision: K2SR30 manual PDF + revision number confirmed at RFQ. |
| DC cabling & protection | H1Z2Z2-K 1.5 kV DC PV cable, DC-rated SPD Class II | Per IEC 62930:2017 (designation cited; IEC Webstore catalogue — webstore.iec.ch — for full publication lookup). |
| AC switchgear | Moulded-case circuit breaker + SSEG-compliant interface per NRS 097-2-1 | Anti-islanding required. Low-voltage switchgear reference: IEC 60947-3:2020 ed4 — IEC 60947-3:2020 ed4 publication page. |

## 3. Import duty & HS classification

**Status: duty rate to be verified against the SARS Tariff document before PO.** The scenario model capex above excludes import duty and VAT uplift; landed-cost uplift must be added at PO stage. Lookup path: SARS Customs and Excise Tariff hub — [sars.gov.za/customs-and-excise/tariff/](https://www.sars.gov.za/customs-and-excise/tariff/).

**HS classification:** 8541.43 — Photovoltaic cells, whether or not assembled in modules or made up into panels (assembled module falls under 8541.43; sub-heading 8541.40 covers individual cells). Inverters typically classified under 8504.40 (static converters). Mounting structures under 7308.90. Import-control permits where applicable: ITAC — [itac.org.za/import-control/](https://www.itac.org.za/import-control/).

## 4. Computed TCO summary (verbatim from scenario model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | ZAR |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (ZAR) | 9,967,417.90 |
| Total discounted cost / PV of costs (ZAR) | 8,295,036.70 |
| Total undiscounted benefit (ZAR) | 67,029,643.59 |
| Total discounted benefit (ZAR) | 23,255,173.95 |
| NPV (ZAR) | 14,960,137.26 |
| IRR | 0.2231 |
| Simple payback (year) | 5.19 |
| Discounted payback (year) | 6.72 |
| LCOE (ZAR/kWh) | 0.9303 |

## 5. Computed year-by-year cash flow (verbatim from scenario model)

Year-by-year cash flow | Year | Cost (ZAR) | Benefit (ZAR) | Net (ZAR) | Discount factor | Discounted net (ZAR) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 7,200,000.00 | 0.0000 | -7,200,000.00 | 1.00 | -7,200,000.00 | 0.0000 |
| 1 | 86,400.00 | 1,315,875.00 | 1,229,475.00 | 0.9259 | 1,138,402.78 | 870,000.00 |
| 2 | 88,128.00 | 1,387,853.36 | 1,299,725.36 | 0.8573 | 1,114,305.01 | 865,650.00 |
| 3 | 89,890.56 | 1,463,768.94 | 1,373,878.38 | 0.7938 | 1,090,628.95 | 861,321.75 |
| 4 | 91,688.37 | 1,543,837.10 | 1,452,148.73 | 0.7350 | 1,067,372.67 | 857,015.14 |
| 5 | 93,522.14 | 1,628,284.99 | 1,534,762.85 | 0.6806 | 1,044,533.81 | 852,730.07 |
| 6 | 95,392.58 | 1,717,352.18 | 1,621,959.60 | 0.6302 | 1,022,109.68 | 848,466.42 |
| 7 | 97,300.43 | 1,811,291.35 | 1,713,990.91 | 0.5835 | 1,000,097.23 | 844,224.08 |
| 8 | 99,246.44 | 1,910,368.98 | 1,811,122.54 | 0.5403 | 978,493.15 | 840,002.96 |
| 9 | 101,231.37 | 2,014,866.17 | 1,913,634.79 | 0.5002 | 957,293.83 | 835,802.95 |
| 10 | 103,256.00 | 2,125,079.34 | 2,021,823.35 | 0.4632 | 936,495.41 | 831,623.93 |
| 11 | 105,321.12 | 2,241,321.18 | 2,136,000.07 | 0.4289 | 916,093.82 | 827,465.81 |
| 12 | 107,427.54 | 2,363,921.45 | 2,256,493.91 | 0.3971 | 896,084.78 | 823,328.48 |
| 13 | 109,576.09 | 2,493,227.96 | 2,383,651.87 | 0.3677 | 876,463.84 | 819,211.84 |
| 14 | 111,767.61 | 2,629,607.53 | 2,517,839.91 | 0.3405 | 857,226.40 | 815,115.78 |
| 15 | 114,002.97 | 2,773,447.06 | 2,659,444.09 | 0.3152 | 838,367.69 | 811,040.20 |
| 16 | 116,283.02 | 2,925,154.61 | 2,808,871.59 | 0.2919 | 819,882.84 | 806,985.00 |
| 17 | 118,608.68 | 3,085,160.57 | 2,966,551.88 | 0.2703 | 801,766.87 | 802,950.08 |
| 18 | 120,980.86 | 3,253,918.85 | 3,132,937.99 | 0.2502 | 784,014.69 | 798,935.33 |
| 19 | 123,400.48 | 3,431,908.21 | 3,308,507.74 | 0.2317 | 766,621.16 | 794,940.65 |
| 20 | 125,868.49 | 3,619,633.59 | 3,493,765.11 | 0.2145 | 749,581.04 | 790,965.95 |
| 21 | 128,385.86 | 3,817,627.55 | 3,689,241.70 | 0.1987 | 732,889.07 | 787,011.12 |
| 22 | 130,953.57 | 4,026,451.78 | 3,895,498.21 | 0.1839 | 716,539.92 | 783,076.06 |
| 23 | 133,572.64 | 4,246,698.69 | 4,113,126.05 | 0.1703 | 700,528.23 | 779,160.68 |
| 24 | 136,244.10 | 4,478,993.11 | 4,342,749.01 | 0.1577 | 684,848.64 | 775,264.88 |
| 25 | 138,968.98 | 4,723,994.03 | 4,585,025.05 | 0.1460 | 669,495.75 | 771,388.55 |

## 6. Scenario verdicts

**Scenario A — High-yield site (Limpopo / Northern Cape, ≥ 1,600 kWh/kWp), Megaflex ≥ 1.70 ZAR/kWh:** GO. Yield and tariff scale factors lift the scenario model benefit stream above the tabled base case. **Scenario B — Base case as tabled (600 kWp, 1,450 kWh/kWp, Megaflex 1.55 ZAR/kWh):** GO. NPV = ZAR 14,960,137, IRR = 22.31%, simple payback 5.19 yrs, discounted payback 6.72 yrs, LCOE 0.9303 ZAR/kWh. Proceed subject to (i) SSEG/Megaflex approval < 9 months, (ii) capex ≤ ZAR 12,000/kWp firm at PO, (iii) SARS duty-rate verification for HS 8541.43 before PO. **Scenario C — Low-yield OR low-tariff site (e.g. Highveld winter-shoulder, OR Ruraflex < 1.30 ZAR/kWh) with capex > ZAR 13,500/kWp:** NO-GO. Discounted payback stretches beyond project horizon; LCOE approaches tariff parity; no margin for inverter replacement.

## 7. Use-Case Reference Datasheet

Use-Case Reference Datasheet — TradVolt / greenhouse-solar-600kwp-za / rev r9 System: 600 kWp DC, grid-tied, rooftop greenhouse mount Equipment family: LONGi Hi-MO 6 monofacial (LR7-72HGD) + Huawei SUN2000-330KTL-H1 + K2 Systems SingleRail K2SR30 Capex band: ZAR 7,200,000 (base, year 0) — sensitivity-bounded; excludes duty + VAT uplift Horizon: 25 years, real discount 8% NPV: 14,960,137 ZAR (base) IRR: 22.31% (project life 25 yr) Simple payback: 5.19 years; Discounted payback: 6.72 years LCOE: 0.9303 ZAR/kWh Duty rate: PENDING — verify via SARS Customs and Excise Tariff, HS 8541.43 Note: This is an internal use-case reference, not a third-party certification. No certificate number or issuer is implied. Validity: 12 months from datePublished, subject to Eskom Megaflex schedule revision.

## 8. Request a firm quotation

The figures above are use-case reference benchmarks. TradVolt routes verified RFQs to pre-computed South African EPCs with greenhouse-mount and SSEG/Megaflex licensing experience. Submit your site details for a binding offer.

[Request a firm quotation — Greenhouse Solar 600 kWp (ZA)](/rfq/)

## 9. Sources

- CSIR, "Solar PV Cost Benchmarks for South Africa, 2024 Update" — [csir.co.za](https://www.csir.co.za/) publication hub

- CSIR / SANEDI, "SA Solar Atlas Yield Validation, 2023" — [sanedi.org.za](https://www.sanedi.org.za/) hub

- Eskom Tariffs and Charges hub, Megaflex 2024/25 — [eskom.co.za/distribution/tariffs-and-charges/](https://www.eskom.co.za/distribution/tariffs-and-charges/) (current schedules; historic PDF URLs superseded)

- NERSA Multi-Year Price Determination 2022-2025 — [nersa.org.za](https://www.nersa.org.za/) MYPD documents

- SARS Customs and Excise Tariff, HS 8541.43 lookup — [sars.gov.za/customs-and-excise/tariff/](https://www.sars.gov.za/customs-and-excise/tariff/)

- ITAC import control (permits, anti-dumping / countervailing investigations) — [itac.org.za/import-control/](https://www.itac.org.za/import-control/)

- IEC 61215-1:2021 ed2, "Terrestrial PV modules — Design qualification and type approval — Part 1: Test requirements" — [IEC 61215-1:2021 ed2 publication page](https://webstore.iec.ch/en/publication/61345)

- IEC 61730-1:2016 ed2, "PV module safety qualification — Part 1: Requirements for construction" — [IEC 61730-1:2016 ed2 publication page](https://webstore.iec.ch/en/publication/25674)

- IEC 62109-1:2010, "Safety of power converters for use in PV power systems — Part 1: General requirements" — [IEC 62109-1:2010 publication page](https://webstore.iec.ch/en/publication/6470)

- IEC 62109-2:2011, "Safety of power converters for use in PV power systems — Part 2: Particular requirements for inverters" — [IEC 62109-2:2011 publication page](https://webstore.iec.ch/en/publication/6471)

- IEC 60947-3:2020 ed4, "Low-voltage switchgear and controlgear — Part 3" — [IEC 60947-3:2020 ed4 publication page](https://webstore.iec.ch/en/publication/59785)

- LONGi Hi-MO 6 / Hi-MO X6 product family — [LONGi Hi-MO X6](https://www.longi.com/en/products/modules-series/hi-mo-x6/) (HPBC cell efficiency > 25.5%; module wattage + warranty datasheet confirmed at RFQ)

- Huawei SUN2000-330KTL-H1 string inverter — [solar.huawei.com SUN2000-330KTL-H1](https://solar.huawei.com/en/products/sun2000-330ktl-h1)

- K2 Systems CrossRail System pitched/flat-roof rail family — [K2 CrossRail System (US)](https://k2-systems.com/en-us/product-solutions/crossrail-system/) (SingleRail K2SR30 manual revision confirmed at RFQ)