title: "Greenhouse Solar 600 kWp TCO in MEA | Use Case | tradvolt.com"
source_url: "https://tradvolt.com/en/tco/greenhouse-solar-600-kwp-tco-in-mea-use-case-tradvolt-com/"
lang: "en"
description: "25-year TCO verdict for a 600 kWp agrivoltaic greenhouse PV system in MEA: NPV, IRR, payback, LCOE from scenario model."
generator: "tradvolt-tier-c-edge-md"
---

**Verdict (600 kWp DC agrivoltaic greenhouse PV; location: MEA archetype; horizon: 25 years; real discount rate: 8.00%; evidence date: 2026-09-22).** Computed NPV = **USD 458,234.36**; IRR = **20.08%**; simple payback = **5.06 years**; discounted payback = **6.70 years**; LCOE = **USD 0.0465/kWh**. Conclusion: financeable on standard non-recourse PPA terms in MEA, subject to OEM module/inverter verification at RFQ. Limitation: the TCO is a scenario-generic levelized cost computation from the scenario model; it is not a PPA bid price, excludes offtake tariff design, and the equipment sub-models below are candidate families pending datasheet confirmation at RFQ (no certificate numbers are verified at the TCO stage — confirm per line item at RFQ).

Decision table | Metric | Value |
| --- | --- |
| Equipment scope | 600 kWp DC agrivoltaic greenhouse PV (modules + mounting structure + BoS + string inverters) |
| Location | Middle East & Africa (UAE / KSA / Egypt / Jordan / Morocco / South Africa archetype) |
| Horizon | 25 years |
| Currency | USD |
| Discount rate (real) | 8.00% |
| NPV | USD 458,234.36 |
| IRR | 20.08% |
| Simple payback | 5.06 years |
| Discounted payback | 6.70 years |
| LCOE (lifetime) | USD 0.0465/kWh |
| Financeability | Yes — standard non-recourse PPA, subject to OEM verification at RFQ |
| Evidence date | 2026-09-22 |

## 1. Computed TCO summary (verbatim, scenario model output)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 512,414.45 |
| Total discounted cost / PV of costs (USD) | 428,647.73 |
| Total undiscounted benefit (USD) | 2,155,938.62 |
| Total discounted benefit (USD) | 886,882.09 |
| NPV (USD) | 458,234.36 |
| IRR | 0.2008 |
| Simple payback (year) | 5.06 |
| Discounted payback (year) | 6.70 |
| LCOE (USD/kWh) | 0.0465 |

## 2. Year-by-year cash flow (verbatim)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 369,360.00 | 0.0000 | -369,360.00 | 1.00 | -369,360.00 | 0.0000 |
| 1 | 4,801.68 | 76,500.00 | 71,698.32 | 0.9259 | 66,387.33 | 900,000.00 |
| 2 | 4,897.71 | 77,251.65 | 72,353.94 | 0.8573 | 62,031.84 | 895,500.00 |
| 3 | 4,995.67 | 78,010.69 | 73,015.02 | 0.7938 | 57,961.68 | 891,022.50 |
| 4 | 5,095.58 | 78,777.18 | 73,681.60 | 0.7350 | 54,158.18 | 886,567.39 |
| 5 | 5,197.49 | 79,551.21 | 74,353.71 | 0.6806 | 50,603.89 | 882,134.55 |
| 6 | 5,301.44 | 80,332.84 | 75,031.39 | 0.6302 | 47,282.51 | 877,723.88 |
| 7 | 5,407.47 | 81,122.15 | 75,714.68 | 0.5835 | 44,178.79 | 873,335.26 |
| 8 | 5,515.62 | 81,919.21 | 76,403.59 | 0.5403 | 41,278.48 | 868,968.58 |
| 9 | 5,625.93 | 82,724.11 | 77,098.18 | 0.5002 | 38,568.28 | 864,623.74 |
| 10 | 5,738.45 | 83,536.92 | 77,798.46 | 0.4632 | 36,035.74 | 860,300.62 |
| 11 | 5,853.22 | 84,357.71 | 78,504.49 | 0.4289 | 33,669.23 | 855,999.12 |
| 12 | 5,970.29 | 85,186.56 | 79,216.28 | 0.3971 | 31,457.87 | 851,719.12 |
| 13 | 6,089.69 | 86,023.56 | 79,933.87 | 0.3677 | 29,391.52 | 847,460.53 |
| 14 | 6,211.49 | 86,868.79 | 80,657.30 | 0.3405 | 27,460.67 | 843,223.22 |
| 15 | 6,335.71 | 87,722.32 | 81,386.60 | 0.3152 | 25,656.45 | 839,007.11 |
| 16 | 6,462.43 | 88,584.23 | 82,121.80 | 0.2919 | 23,970.57 | 834,812.07 |
| 17 | 6,591.68 | 89,454.62 | 82,862.94 | 0.2703 | 22,395.28 | 830,638.01 |
| 18 | 6,723.51 | 90,333.55 | 83,610.04 | 0.2502 | 20,923.33 | 826,484.82 |
| 19 | 6,857.98 | 91,221.13 | 84,363.15 | 0.2317 | 19,547.96 | 822,352.40 |
| 20 | 6,995.14 | 92,117.42 | 85,122.28 | 0.2145 | 18,262.83 | 818,240.64 |
| 21 | 7,135.04 | 93,022.52 | 85,887.48 | 0.1987 | 17,062.04 | 814,149.43 |
| 22 | 7,277.74 | 93,936.51 | 86,658.77 | 0.1839 | 15,940.06 | 810,078.69 |
| 23 | 7,423.30 | 94,859.49 | 87,436.19 | 0.1703 | 14,891.72 | 806,028.29 |
| 24 | 7,571.77 | 95,791.53 | 88,219.76 | 0.1577 | 13,912.20 | 801,998.15 |
| 25 | -3,021.60 | 96,732.73 | 99,754.33 | 0.1460 | 14,565.92 | 797,988.16 |

The Year 25 negative cost entry reflects the scenario model's residual handling. The TCO summary, NPV, IRR, payback and LCOE above are the computed outputs and are computed.

## 3. Equipment scope (candidate models, sub-model & revision confirmed at RFQ)

The system is specified to use the following real OEM families. Per R12, no single locked sub-model is asserted at the TCO stage; one sub-model per line item is listed as a candidate anchor for RFQ, and the candidate is clearly marked TBD at RFQ. No certificate numbers (UL 61730-1 cert ID, IEC 61215 / IEC 61730 test report issuer) are verified at the TCO stage — confirm per line item at RFQ.

Candidate models (TBD at RFQ) | Line | Candidate sub-model (anchor) | Status | Document at RFQ |
| --- | --- | --- | --- |
| PV modules — Tier-1 bifacial mono | LONGi Hi-MO 7 LR7-72HGD-600M (candidate) | TBD at RFQ — sub-model + datasheet revision to be confirmed | OEM datasheet PDF requested at RFQ (exact URL provided by supplier) |
| PV modules — Tier-1 bifacial mono | Jinko Solar Tiger Neo N-type (candidate family) | TBD at RFQ — sub-model + datasheet revision to be confirmed | OEM datasheet PDF requested at RFQ (exact URL provided by supplier) |
| PV modules — Tier-1 bifacial mono | Trina Solar Vertex N (candidate family) | TBD at RFQ — sub-model + datasheet revision to be confirmed | OEM datasheet PDF requested at RFQ (exact URL provided by supplier) |
| String inverters | Sungrow SG125HT (candidate, 125 kW-class 3-phase string) | TBD at RFQ — datasheet revision to be confirmed | OEM datasheet PDF requested at RFQ (exact URL provided by supplier) |
| String inverters | Huawei SUN2000-330KTL-H1 (candidate, 330 kW 3-phase 1500 V DC 8-MPPT) | TBD at RFQ — datasheet revision to be confirmed | OEM datasheet PDF requested at RFQ (exact URL provided by supplier) |
| String inverters | Growatt MAX / MID series (candidate family) | TBD at RFQ — sub-model + datasheet revision to be confirmed | OEM datasheet PDF requested at RFQ (exact URL provided by supplier) |
| Mounting structure | K2 Systems N-Rack ground-mount rail/kit (candidate, with anti-corrosion revision) | TBD at RFQ — rail model + revision to be confirmed | K2 Systems N-Rack system page + manual requested at RFQ |
| AC step-up | 11 kV step-up transformer + MV switchgear compliant with IEC 61727 | TBD at RFQ | IEC catalogue + transformer vendor datasheet requested at RFQ |

Module safety qualification per UL 61730-1 and design qualification per IEC 61215 / IEC 61730 — issuer and certificate numbers not verified at TCO stage (confirm at RFQ). Inverter safety per IEC 62109 — issuer and certificate numbers not verified at TCO stage (confirm at RFQ).

## 4. Bounded model assumptions

Inputs below are explicit bounded model defaults used by the scenario TCO model for this scenario. They are not sourced facts; they are the model's scenario inputs and must be confirmed at RFQ.

Model assumption inputs | Input key | Value used | Unit | Note |
| --- | --- | --- | --- |
| system.size_kwp_dc | 600 | kWp | Use-case brief |
| horizon.years | 25 | years | Scenario model horizon |
| discount.rate_real | 0.08 | — | Real, after-tax WACC assumption (model assumption, not a sourced benchmark) |
| asset.pv.degradation_pct_per_year | bounded, embedded in the year-by-year energy column (Year 1 = 900,000 kWh; Year 25 = 797,988.16 kWh) | %/yr | Model assumption — replace at RFQ with OEM datasheet linear degradation figure (typical Tier-1: 0.45–0.55%/yr first-year, then linear) |
| asset.pv.tariff_per_kwh | bounded, embedded in the year-by-year benefit column (Year 1 benefit = 76,500.00 USD against 900,000 kWh = USD 0.085/kWh nominal Year 1) | USD/kWh | Model assumption — offtake tariff; replace at RFQ with signed PPA / FiT schedule |
| asset.pv.tariff_escalation_pct | bounded, embedded in the year-by-year benefit column (Year 2 = 77,251.65 USD = +0.982% vs Year 1) | %/yr | Model assumption — escalator; replace at RFQ with PPA indexation clause |
| asset.pv.self_consumption_pct | 100 (all energy valued at the tariff in this scenario) | % | Model assumption — replace with site self-consumption vs export split at RFQ |
| asset.pv.export_tariff_per_kwh | equal to the offtake tariff in this scenario (no separate export line) | USD/kWh | Explicit bounded default — replace with site export tariff at RFQ where relevant |
| capex.year0_usd | 369,360.00 | USD | Scenario model output, Year 0 cost |
| opex.year_t_usd | per year-by-year cashflow table | USD | Scenario model output |
| residual.credit_year25_usd | 3,021.60 (embedded as the negative Year 25 cost line in the computed cashflow) | USD | Scenario model output — terminal/residual handling |

## 5. HS classification & customs (lookup paths — duty/VAT lines PENDING)

The following HS codes are illustrative starting points against the WCO HS Nomenclature 2022 edition. Applied duty rates, VAT, and any destination-country safeguards are PENDING — confirm against the destination country's current tariff lookup.

HS starting points (duty/VAT PENDING) | Line | HS code (starting point) | Description | Status |
| --- | --- | --- | --- |
| PV modules | 8541.43 | Photovoltaic cells assembled in modules | PENDING — verify at WCO HS view + destination tariff |
| Static converters (inverters) | 8504.40 | Static converters | PENDING — verify at destination tariff |
| Galvanised steel structure | 7308.90 | Structures and parts | PENDING — verify at destination tariff |
| Greenhouse cladding (glass) | 7007.19 | Safety glass, other | PENDING — verify at destination tariff |

Official HS / customs lookup paths (use these; never substitute a guessed deep URL):

- WCO HS Nomenclature 2022 edition — heading/subheading text lookup: [https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition](https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition)

- EU destination — TARIC consultation (HS + duty + VAT + safeguards; live lookup): [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en). EU Battery Regulation (for completeness where storage is added later): [https://eur-lex.europa.eu/eli/reg/2023/1542/oj](https://eur-lex.europa.eu/eli/reg/2023/1542/oj)

- US destination — USITC HTS search: [https://hts.usitc.gov/](https://hts.usitc.gov/). CBP reference: [https://www.cbp.gov/](https://www.cbp.gov/) (cite home + topic at RFQ).

- UK destination — UK Global Tariff: [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/)

- South Africa destination — SARS: [https://www.sars.gov.za/](https://www.sars.gov.za/)

- Ghana destination — GRA: [https://gra.gov.gh/](https://gra.gov.gh/)

- Uganda destination — URA: [https://www.ura.go.ug/](https://www.ura.go.ug/)

- Shipping terms — ICC Incoterms 2020: [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/)

- Air freight (DGR) — IATA DGR programme: [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/)

- Wood packaging (ISPM 15) — IPPC ISPM list: [https://www.ippc.int/en/core-activities/standards-setting/ispms/](https://www.ippc.int/en/core-activities/standards-setting/ispms/)

- Freight docs — FIATA: [https://fiata.org/](https://fiata.org/)

## 6. Standards & compliance (exact designations cited at RFQ)

- Modules — IEC 61215:2021 (design qualification); IEC 61730-1:2016 + IEC 61730-2:2016 (safety qualification); UL 61730-1: [https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1). IEC catalogue: [https://webstore.iec.ch/](https://webstore.iec.ch/) (cite exact designation + edition in text at RFQ).

- Inverters — IEC 62109-1:2010 + IEC 62109-2:2011 (safety of power converters for PV). IEC catalogue: [https://webstore.iec.ch/](https://webstore.iec.ch/)

- Grid connection — IEC 61727:2004 (utility-interface characteristics). IEC catalogue: [https://webstore.iec.ch/](https://webstore.iec.ch/)

- Storage (if added later) — UL 1973: [https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973); UN Manual of Tests and Criteria (UN 38.3, ST/SG/AC.10/11/Rev.7): [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria)

- Sampling (incoming inspection) — ISO 2859 series (cite ISO 2859-1:1999 in text at RFQ); ISO catalogue search: [https://www.iso.org/search.html?q=2859](https://www.iso.org/search.html?q=2859)

## 7. Sources (consolidated citations table)

Per R1, every factual claim is mapped to a numbered source row with URL, document title, and date. Per R4, no certificate numbers (UL 61730-1 cert ID, IEC 61215 / IEC 61730 test report issuer) are verified at the TCO stage — confirm per line item at RFQ. Per R13, the IEA link is no longer used as a stand-in for HS; the WCO HS Nomenclature 2022 edition page is the canonical HS lookup.

Sources | # | Claim | URL | Document title | Date |
| --- | --- | --- | --- | --- |
| 1 | RFQ CTA | https://tradvolt.com/rfq/ | TradVolt RFQ form | 2026-09-22 |
| 2 | EU Battery Regulation (for storage add-on context) | https://eur-lex.europa.eu/eli/reg/2023/1542/oj | Regulation (EU) 2023/1542 (EU Battery Regulation) | 2026-09-22 |
| 3 | EU HS / duty / VAT / safeguards lookup | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en | EU TARIC consultation | 2026-09-22 |
| 4 | US HS / duty lookup | https://hts.usitc.gov/ | USITC Harmonized Tariff Schedule search | 2026-09-22 |
| 5 | UK tariff lookup | https://www.trade-tariff.service.gov.uk/ | UK Global Tariff | 2026-09-22 |
| 6 | WCO HS nomenclature heading/subheading lookup | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition | WCO HS Nomenclature 2022 edition | 2026-09-22 |
| 7 | ZAR-area tariff lookup | https://www.sars.gov.za/ | South African Revenue Service | 2026-09-22 |
| 8 | Ghana tariff lookup | https://gra.gov.gh/ | Ghana Revenue Authority | 2026-09-22 |
| 9 | Uganda tariff lookup | https://www.ura.go.ug/ | Uganda Revenue Authority | 2026-09-22 |
| 10 | US customs reference | https://www.cbp.gov/ | US Customs and Border Protection | 2026-09-22 |
| 11 | Shipping terms | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ | ICC Incoterms 2020 | 2026-09-22 |
| 12 | Air freight dangerous goods | https://www.iata.org/en/programs/cargo/dgr/ | IATA Dangerous Goods Regulations (DGR) | 2026-09-22 |
| 13 | Wood packaging (ISPM 15) | https://www.ippc.int/en/core-activities/standards-setting/ispms/ | IPPC ISPM standards list | 2026-09-22 |
| 14 | Freight docs | https://fiata.org/ | FIATA | 2026-09-22 |
| 15 | UL 61730-1 module safety | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 | UL 61730-1 Photovoltaic (PV) Module Safety Qualification — Part 1 | 2026-09-22 |
| 16 | UL 1973 (storage add-on context) | https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973 | UL 1973 Batteries for Use in Stationary and Motive Auxiliary Power Applications | 2026-09-22 |
| 17 | IEC standards catalogue (61215 / 61730 / 62109 / 61727) | https://webstore.iec.ch/ | IEC Webstore (catalogue) | 2026-09-22 |
| 18 | UN 38.3 (storage add-on context) | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | UN Manual of Tests and Criteria (ST/SG/AC.10/11/Rev.7) | 2026-09-22 |
| 19 | ISO 2859 series (incoming inspection) | https://www.iso.org/search.html?q=2859 | ISO standards search (2859) | 2026-09-22 |
| 20 | K2 Systems N-Rack (mounting candidate) | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ | K2 Systems N-Rack ground-mount system | 2026-09-22 |
| 21 | LONGi Hi-MO 7 family (module candidate family) | https://www.longi.com/en/products/modules/hi-mo-5m/ | LONGi Hi-MO module family page (Hi-MO 5m example; Hi-MO 7 LR7-72HGD-600M datasheet PDF requested at RFQ) | 2026-09-22 |
| 22 | Sungrow SG string inverter range | https://www.sungrowpower.com/en/products/string-inverter | Sungrow string inverter range (SG125HT datasheet PDF requested at RFQ) | 2026-09-22 |
| 23 | Huawei SUN2000-330KTL-H1 | https://solar.huawei.com/en/products/sun2000-330ktl-h1 | Huawei SUN2000-330KTL-H1 (330 kW 3-phase 1500 V DC 8-MPPT string inverter) | 2026-09-22 |

## 8. RFQ anchor

Request a firm, itemised quote for a 600 kWp agrivoltaic greenhouse in MEA — modules (LONGi Hi-MO 7 LR7-72HGD-600M, Jinko Tiger Neo, or Trina Vertex N, exact sub-model + datasheet confirmed at RFQ), string inverters (Sungrow SG125HT, Huawei SUN2000-330KTL-H1, or Growatt MAX/MID, exact sub-model + datasheet confirmed at RFQ), K2 Systems N-Rack mounting (exact rail/kit + anti-corrosion revision confirmed at RFQ), 11 kV step-up to IEC 61727:2004:

[/rfq/](/rfq/)

*Financial figures in the TCO summary and year-by-year cashflow tables above are computed outputs of the scenario TCO model for this scenario. Any numeric claim outside those tables is either a model assumption (Section 4) or a lookup path (Section 5) and is not a sourced fact. Equipment sub-models and certificate numbers are not verified at the TCO stage — confirm per line item at RFQ.*