# Import a Sungrow SG10KTL-MT 10kW On-Grid Inverter from China to Canada — Factory Rooftop TCO

**Verdict (numeric):** **NPV = +USD 864** over a 25-year horizon at a 5.00% discount rate. **Discounted payback = 23.23 years**; **simple payback = 14.90 years**; **IRR = 5.51%**; **LCOE = USD 0.1277 / kWh** (all undiscounted costs USD 25,614.82; discounted costs USD 20,606.53; undiscounted benefits USD 40,500.68; discounted benefits USD 21,470.19). At the modelled CapEx of USD 15,000 and the bounded electricity-price assumptions below, the project is marginally NPV-positive but does not pay back within the asset&rsquo;s 25-year economic horizon on a discounted basis — treat as borderline, not a green-light.

**Equipment:** Sungrow SG10KTL-MT, 10 kW AC, three-phase on-grid (grid-tie) solar PV inverter (publicly marketed residential/commercial C&I string inverter, Sungrow Power Supply Co., Ltd., Hefei, CN).

**Location:** China (origin) &rarr; Canada (destination), factory rooftop C&I installation.

**Horizon:** 25 years.

**Evidence date:** 2026-09-22.

**Limitation:** The COMPUTED TCO above is a model output for the bounded scenario below; the underlying CapEx is a single-point assumption (USD 15,000 landed, of which USD 12,500 is the inverter+BoS equipment and USD 2,500 is freight+duty+brokerage+EPC commissioning), not a binding vendor quote. Real quotes are obtained via the RFQ below. See the bounded-model-assumptions block for tariff, export-tariff, residual-value and yield inputs.

Decision table — TCO headline metrics | Metric | Value |
| --- | --- |
| Currency | USD |
| Equipment | Sungrow SG10KTL-MT (10 kW AC, 3-phase on-grid) |
| Horizon (years) | 25 |
| Discount rate | 5.00 % |
| Total undiscounted cost (USD) | 25,614.82 |
| Total discounted cost / PV of costs (USD) | 20,606.53 |
| Total undiscounted benefit (USD) | 40,500.68 |
| Total discounted benefit (USD) | 21,470.19 |
| NPV (USD) | 863.66 |
| IRR | 0.0551 |
| Simple payback (year) | 14.90 |
| Discounted payback (year) | 23.23 |
| LCOE (USD/kWh) | 0.1277 |

[Request Quote — replies in 48h](/rfq/) [Sungrow SG10KTL-MT Datasheet (OEM)](#download-top)

## Equipment reference — Sungrow SG10KTL-MT

The modelled inverter is the **Sungrow SG10KTL-MT**, a publicly marketed three-phase, two-MPPT, transformerless 10 kW AC on-grid (grid-tie) string inverter in Sungrow&rsquo;s residential / small commercial & industrial (C&I) portfolio. The model name, AC output rating and topology are taken from Sungrow&rsquo;s publicly listed product family.

- OEM: Sungrow Power Supply Co., Ltd., Hefei, CN.

- Model: SG10KTL-MT (10 kW AC, three-phase, two MPPTs, transformerless).

- OEM product page: [https://www.sungrowpower.com/en](https://www.sungrowpower.com/en) (model confirmed at RFQ; Sungrow product detail pages are JS-rendered, so the named model + datasheet PDF is the computed source).

- Datasheet (publicly hosted by Sungrow / partners): see &ldquo;Download&rdquo; section below for the exact SG10KTL-MT datasheet URL.

- Limits used in any installation procedure (DC max voltage, MPPT voltage window, max input current per MPPT, AC grid-code settings, torque values) are taken from the OEM installation manual revision that ships with the SG10KTL-MT — always re-confirm against the manual revision packed with the unit before commissioning.

## Bounded assumptions (the model defaults the draft did not state)

The scenario TCO above was computed on the following explicit, bounded assumptions. They are not sourced market prices; they are bounded model inputs so the NPV / payback cells can be recomputed.

- **System size:** 10 kWp DC PV array / 10 kW AC inverter (DC/AC ratio ~1.0 in the baseline).

- **CapEx split (year 0, USD landed Canada, before incentives):** Inverter + PV modules + DC/AC BoS (cabling, connectors, AC disconnect, mounting) = **USD 12,500**; freight + duty + taxes + brokerage + EPC install + utility-interconnection commissioning = **USD 2,500**; total year-0 CapEx = **USD 15,000**.

- **Replacement event (year 12):** USD 1,500 inverter swap reserve booked in year 12 cost line; year-by-year table is the computed source of timing.

- **Annual OpEx (years 1–11, 13–25):** USD 250/yr (preventive maintenance, insurance, monitoring, cleaning), escalated at 3%/yr (matches the year-by-year table).

- **Annual generation:** 12,000 kWh in year 1 (1,200 kWh/kWp on a 10 kWp array — bounded illustrative value for southern Canada industrial rooftops; the table applies ~0.5%/yr linear PV degradation).

- **Self-consumption & tariff split:** 70% self-consumed (avoided grid import), 30% exported to grid.

- **Grid import price avoided (C$ self-consumption offset):** bounded at **CAD 0.15 / kWh** (~USD 0.111/kWh at 1.35 USD/CAD), escalated 3%/yr.

- **Grid export price (export-tariff, &ldquo;microFIT/microgen&rdquo;-class compensation):** bounded at **CAD 0.082 / kWh** (~USD 0.0607/kWh at 1.35 USD/CAD), escalated 3%/yr.

- **Discount rate (WACC, applied consistently to all years):** 5.00%/yr.

- **Residual value at end of year 25:** **USD 0** (fully depreciated inverter + BoS; the table includes no terminal-value credit).

- **Time basis:** End-of-year cash flows for years 1–25; year 0 is the capex outlay; discount factors in the table are computed as 1/(1+0.05)t.

- **Currency:** USD throughout (CNY/CAD spot, FX, provincial sales tax and CUSMA effects are not separately modelled; see duty stack for qualitative treatment).

## Year-by-year cash flow (computed)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 15,000.00 | 0.0000 | -15,000.00 | 1.00 | -15,000.00 | 0.0000 |
| 1 | 250.00 | 1,188.00 | 938.00 | 0.9524 | 893.33 | 12,000.00 |
| 2 | 257.50 | 1,217.52 | 960.02 | 0.9070 | 870.77 | 11,940.00 |
| 3 | 265.22 | 1,247.78 | 982.55 | 0.8638 | 848.77 | 11,880.30 |
| 4 | 273.18 | 1,278.78 | 1,005.60 | 0.8227 | 827.31 | 11,820.90 |
| 5 | 281.38 | 1,310.56 | 1,029.19 | 0.7835 | 806.39 | 11,761.79 |
| 6 | 289.82 | 1,343.13 | 1,053.31 | 0.7462 | 786.00 | 11,702.99 |
| 7 | 298.51 | 1,376.51 | 1,077.99 | 0.7107 | 766.11 | 11,644.47 |
| 8 | 307.47 | 1,410.71 | 1,103.24 | 0.6768 | 746.72 | 11,586.25 |
| 9 | 316.69 | 1,445.77 | 1,129.08 | 0.6446 | 727.81 | 11,528.32 |
| 10 | 326.19 | 1,481.70 | 1,155.50 | 0.6139 | 709.38 | 11,470.67 |
| 11 | 335.98 | 1,518.52 | 1,182.54 | 0.5847 | 691.41 | 11,413.32 |
| 12 | 1,846.06 | 1,556.25 | -289.81 | 0.5568 | -161.38 | 11,356.25 |
| 13 | 356.44 | 1,594.92 | 1,238.48 | 0.5303 | 656.79 | 11,299.47 |
| 14 | 367.13 | 1,634.56 | 1,267.42 | 0.5051 | 640.14 | 11,242.98 |
| 15 | 378.15 | 1,675.18 | 1,297.03 | 0.4810 | 623.89 | 11,186.76 |
| 16 | 389.49 | 1,716.81 | 1,327.31 | 0.4581 | 608.06 | 11,130.83 |
| 17 | 401.18 | 1,759.47 | 1,358.29 | 0.4363 | 592.62 | 11,075.17 |
| 18 | 413.21 | 1,803.19 | 1,389.98 | 0.4155 | 577.56 | 11,019.80 |
| 19 | 425.61 | 1,848.00 | 1,422.39 | 0.3957 | 562.89 | 10,964.70 |
| 20 | 438.38 | 1,893.92 | 1,455.55 | 0.3769 | 548.58 | 10,909.88 |
| 21 | 451.53 | 1,940.99 | 1,489.46 | 0.3589 | 534.63 | 10,855.33 |
| 22 | 465.07 | 1,989.22 | 1,524.15 | 0.3418 | 521.03 | 10,801.05 |
| 23 | 479.03 | 2,038.65 | 1,559.63 | 0.3256 | 507.77 | 10,747.04 |
| 24 | 493.40 | 2,089.31 | 1,595.92 | 0.3101 | 494.84 | 10,693.31 |
| 25 | 508.20 | 2,141.23 | 1,633.03 | 0.2953 | 482.24 | 10,639.84 |

The discounted net column sums to NPV = USD 863.66. Simple payback is reached when cumulative undiscounted net first turns positive (year 14.90); discounted payback is reached when cumulative discounted net first turns positive (year 23.23). The year-12 cost spike (USD 1,846.06) is the bounded inverter mid-life replacement reserve and is the dominant cause of the long discounted payback.

## Canada duty / tariff stack (CN &rarr; Canada)

**HS national line:** 8504.40 — Static converters (most common classification cited for photovoltaic inverters; verify the exact 10-digit Canadian HS line against the official CBSA Tariff Database before binding).
**As-of:** 2026-09-22. **SoT:** CBSA Tariff Database (see Sources).

| Layer | Program / Instrument | Treatment | Source |
| --- | --- | --- | --- |
| Customs duty — MFN (General Tariff) | CBSA Tariff Database, HS 8504.40 | Bound duty rate applies; consult CBSA Tariff Database for the current MFN rate. Verify at binding. | CBSA Tariff Database |
| CUSMA preferential duty | Canada–United States–Mexico Agreement (CUSMA) — preferential tariff treatment | Available only if the inverter qualifies under the applicable CUSMA Rules of Origin (CN-origin inverters typically do not qualify for CUSMA preferential treatment); requires a Certificate of Origin. | Canada (GAC) — CUSMA agreement information |
| Anti-dumping / countervailing | Special Import Measures Act (SIMA) measures on CN-origin inverters / BoS | Confirm against the live CBSA SIMA measure list at binding; PV-inverter-specific SIMA findings have been issued in adjacent product lines — check before quoting. | CBSA — SIMA |
| Federal tax — GST | Canada Revenue Agency — GST/HST | 5% federal GST applies on the duty-paid value at import. | CRA — GST/HST |
| Provincial sales tax | HST / PST / QST (province-dependent) | Applies on the duty-paid value at import per destination province (ON, NB, NL, NS = 15% HST; BC, SK, MB = 5% GST + provincial PST; QC = 5% GST + QST; AB, YT, NT, NU = 5% GST only). Confirm per province at binding. | CRA — GST/HST |
| Customs broker fee | Third-party broker entry fee | Order-of-magnitude CAD 100–300 per entry (typical band); confirm with the appointed broker. | Third-party Canadian customs broker |

The 10-digit HS national line for a 10 kW on-grid (grid-tie) photovoltaic inverter must be confirmed against the official CBSA Tariff Database. The MFN duty treatment, any active SIMA measure, and provincial sales tax stacking must be re-verified before binding.

## Compliance & certifications (typical for Canadian grid-tie inverters)

- **UL 1741** — Standard for Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources. [UL Standards & Engagement storefront](https://www.shopulstandards.com/).

- **IEEE 1547 / IEEE 1547.1** — Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces. [IEEE 1547 project page](https://standards.ieee.org/project/1547.html).

- **CSA C22.1** — Canadian Electrical Code, Part I (adopted provincially with amendments). [CSA Group standards catalogue](https://www.csagroup.org/standards/standards-catalog/).

- **CSA C22.2 No. 107.1** — Power conversion equipment. [CSA Group standards catalogue](https://www.csagroup.org/standards/standards-catalog/).

- **UL 61730-1** — Photovoltaic (PV) Module Safety Qualification — Part 1 (applies to the PV modules in the BoS). [UL 61730-1 standard page](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1).

TradVolt does not display certification numbers, marks or issuer logos on this page. Confirmation that the Sungrow SG10KTL-MT shipment carries the above certifications (with certificate IDs) is part of the RFQ due-diligence pack.

## Request a quote — replies in 48h

Submit the form below. TradVolt&rsquo;s RFQ endpoint is the live form at [/rfq/](/rfq/).

## Sungrow SG10KTL-MT datasheet (OEM)

The OEM datasheet for the SG10KTL-MT is published on Sungrow&rsquo;s website. Open it directly from the OEM:

- Sungrow product listing (landing): [https://www.sungrowpower.com/en](https://www.sungrowpower.com/en) (the SG10KTL-MT datasheet PDF is served from Sungrow&rsquo;s product & downloads area; if the direct file URL rotates, request the current SG10KTL-MT datasheet via the RFQ form above).

- Standards page (IEC 61851-1 is not applicable to a PV inverter; for PV-inverter safety, see UL 1741 / UL 61730-1 above; standards catalogue at [IEC Webstore](https://webstore.iec.ch/)).

The OEM installation / service manual revision that ships with the SG10KTL-MT (torque values, DC max voltage, MPPT window, AC grid-code settings) is the computed source for any installation procedure limits — always re-confirm against the manual revision packed with the unit before commissioning.

## FAQ

### What HS code applies to a 10 kW on-grid (grid-tie) solar inverter imported into Canada?

Most-cited classification is HS 8504.40 (Static converters) for photovoltaic inverters. Confirm the exact 10-digit Canadian national line via the [CBSA Tariff Database](https://www.cbsa-asfc.gc.ca/trade-commerce/tariff-tarif/menu-eng.html) before binding.

### Is the 10 kW on-grid inverter subject to Canadian duties under CUSMA?

Only if the unit qualifies under the CUSMA Rules of Origin (CN-origin inverters typically do not qualify for CUSMA preferential treatment). Confirm via the [CBSA CUSMA tariff information page](https://www.international.gc.ca/trade-commerce/trade-agreements-accords-commerciaux/agr-acc/cusma-aceum/index.aspx?lang=eng) and the Rules of Origin; a Certificate of Origin is required.

### Which certifications apply to a grid-tie inverter in Canada?

Commonly UL 1741 (inverter / DER interconnection), IEEE 1547 / IEEE 1547.1 (DER interconnection), CSA C22.1 (Canadian Electrical Code, Part I, adopted provincially) and CSA C22.2 No. 107.1 (power conversion). PV-module safety typically UL 61730-1. Confirm certificate IDs with the OEM datasheet before purchase.

### What does the TCO show for a factory-rooftop 10 kW PV system using a grid-tie inverter in Canada?

At the bounded assumptions on this page (USD 15,000 landed CapEx, 70% self-consumption, 1,200 kWh/kWp, 25-year horizon, 5.00% discount rate, inverter mid-life replacement reserve in year 12), the project is marginally NPV-positive (USD 863.66) with a discounted payback of 23.23 years — borderline, not a green-light. Actual payback depends on the binding quote, rooftop irradiation, self-consumption ratio, local utility tariff and any provincial incentives.

### Does the 10 kW on-grid inverter require provincial or utility interconnection approval in Canada?

Yes. Interconnection to the provincial / territorial distribution grid requires the local utility / LDC interconnection process and conformance with the applicable provincial grid code (e.g., IESO in Ontario, AESO in Alberta, Hydro-Qu&eacute;bec). Confirm with the relevant provincial system operator and the LDC.

### How fast does TradVolt reply to RFQs?

TradVolt replies to RFQs within 48 business hours from a qualified buyer submission containing product SKU, quantity + unit, Incoterm, target certification, destination country, buyer email and buyer company.

## Sources (claim-row table)

| Claim | Source: NAME | URL | Accessed |
| --- | --- | --- | --- |
| Canadian border tariff lookup (HS 8504.40 and 10-digit national line confirmation) | Canada Border Services Agency — Tariff Database | https://www.cbsa-asfc.gc.ca/trade-commerce/tariff-tarif/menu-eng.html | 2026-09-22 |
| CUSMA preferential tariff treatment and Rules of Origin | Canada Border Services Agency — CUSMA tariff information | https://www.international.gc.ca/trade-commerce/trade-agreements-accords-commerciaux/agr-acc/cusma-aceum/index.aspx?lang=eng | 2026-09-22 |
| Anti-dumping / countervailing measures on CN-origin goods | Canada Border Services Agency — SIMA | https://www.cbsa-asfc.gc.ca/sima-lmsi/ | 2026-09-22 |
| GST / HST federal and provincial rates and mechanics | Canada Revenue Agency — GST/HST | https://www.canada.ca/en/revenue-agency/services/tax/businesses/topics/gst-hst-businesses.html | 2026-09-22 |
| UL 1741 (inverter / DER interconnection equipment) | UL Standards & Engagement storefront | https://www.shopulstandards.com/ | 2026-09-22 |
| IEEE 1547 (DER interconnection) | IEEE Standards Association | https://standards.ieee.org/project/1547.html | 2026-09-22 |
| CSA C22.1 / CSA C22.2 No. 107.1 (Canadian Electrical Code, Part I; power conversion) | CSA Group standards catalogue | https://www.csagroup.org/standards/standards-catalog/ | 2026-09-22 |
| UL 61730-1 (PV module safety) | UL Standards & Engagement storefront | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 | 2026-09-22 |
| Other IEC standards referenced (catalogue lookup, exact edition cited in text) | IEC Webstore | https://webstore.iec.ch/ | 2026-09-22 |
| Sungrow SG10KTL-MT model identity, datasheet and manual revision | Sungrow Power Supply Co., Ltd. | https://www.sungrowpower.com/en | 2026-09-22 |
| Canadian PV potential / yield reference (bounded 1,200 kWh/kWp assumption) | Natural Resources Canada — Photovoltaic Potential and Solar Resource Maps | https://www.canada.ca/en/natural-resources-canada/services/climate-change-adaptation-services/renewable-energy/solar-resource-maps-photovoltaic-potential.html | 2026-09-22 |
| FX reference (USD/CAD spot for the bounded electricity-price block) | Bank of Canada — Valet FX | https://www.bankofcanada.ca/valet/fx_rates | 2026-09-22 |
| RFQ form (live) | TradVolt — Request a Quote | https://tradvolt.com/rfq/ | 2026-09-22 |

[Request Quote — replies in 48h](/rfq/) [Sungrow product page (OEM)](https://www.sungrowpower.com/en)