title: "Import 50 kW On-Grid Inverter from China to Slovenia — Hangar-Rooftop TCO | tradvolt.com"
source_url: "https://tradvolt.com/en/tco/import-50-kw-on-grid-inverter-from-china-to-slovenia-hangar-rooftop-tco-tradvolt-com/"
lang: "en"
description: "B2B TCO and landed-cost framework for sourcing a Sungrow SG50CX or Huawei SUN2000-50KTL-M3 three-phase 50 kW on-grid inverter from China to Slovenia for a hangar rooftop. NPV, payback and LCOE based on the scenario TCO model."
generator: "tradvolt-tier-c-edge-md"
---

B2B TCO / Landed Cost CN → Slovenia Vertical: Solar BoS Use-case: Hangar rooftop, 50 kW

# Import 50 kW On-Grid Inverter from China to Slovenia — Hangar-Rooftop TCO & Landed Cost

**Verdict (scenario model, as-of 2026-09-21):** For a three-phase 50 kW on-grid string inverter (Sungrow SG50CX class, Huawei SUN2000-50KTL-M3 alternative) imported from China and installed on a commercial hangar rooftop in Slovenia, the scenario TCO model returns **NPV = EUR 53,092.62** at an 8.00% discount rate over a 25-year horizon. **Simple payback = 6.58 years**; **discounted payback = 9.53 years**; **LCOE = EUR 0.1259/kWh**; IRR = 15.46%. Scenario evidence-date 2026-09-21. Limitation: figures derive from the bounded defaults in §3 (residual value, PV degradation, tariff escalation) and from one quoted FOB unit price; replace any bounded default with a buyer-specific value before relying on the result for procurement.

| Decision metric | Value | Unit |
| --- | --- | --- |
| Equipment | On-grid string inverter, 50 kW three-phase (reference: Sungrow SG50CX; alternative: Huawei SUN2000-50KTL-M3) | — |
| Location | Slovenia (CN → Koper/Ljubljana) | — |
| Horizon | 25 | years |
| Discount rate | 8.00 | % |
| NPV | 53,092.62 | EUR |
| IRR | 0.1546 | — |
| Simple payback | 6.58 | year |
| Discounted payback | 9.53 | year |
| LCOE | 0.1259 | EUR/kWh |
| Evidence-date | 2026-09-21 | — |

This page is a buyer-side TCO and landed-cost framework for sourcing a three-phase 50 kW on-grid string inverter from Chinese OEMs to a hangar rooftop in Slovenia. The reference equipment candidate is the Sungrow SG50CX; the Huawei SUN2000-50KTL-M3 is offered as an alternative at RFQ stage. CapEx, OpEx, NPV, IRR, payback and LCOE are taken from the scenario TCO model. EU duty and Slovenian VAT are HS-code-dependent and remain PENDING — lookup against TARIC and FURS at quote stage.

[Request Quote — replies in 48h](#rfq) [Open RFQ form](/rfq/)

## 1. Use-case context: 50 kW on-grid inverter on a hangar rooftop

A hangar is a large, low-rise steel building with a long, mostly unobstructed roof surface. In Slovenia, commercial-scale rooftop PV typically connects to the low-voltage three-phase 400 V grid via the local DSO in SODO-eligible areas. A single 50 kW three-phase string inverter is a standard building block for commercial BoS in this power class.

- **Standard commercial building block:** the 50 kW three-phase string class is widely deployed on commercial / industrial rooftops. [Src: Sungrow SG50CX product family page, https://www.sungrowpower.com/Product/index/id/3.html accessed 2026-09-21]

- **Transformerless topology:** confirmed on the SG50CX datasheet (no low-frequency transformer; integrated DC switch, Type II DC/AC SPD). [Src: Sungrow SG50CX datasheet PDF, https://www.sungrowpower.com/UploadFile/file/20231219/20231219100826_10304.pdf accessed 2026-09-21]

- **Low-voltage 400 V AC output avoids MV step-up:** the SG50CX nominal AC output is 400 V three-phase, matching the Slovenian low-voltage distribution level. [Src: Sungrow SG50CX datasheet PDF, p.2, https://www.sungrowpower.com/UploadFile/file/20231219/20231219100826_10304.pdf accessed 2026-09-21; Slovenia distribution voltage levels, SODO connection rules document, https://www.sodo.si/dokumenti/Sistemska_obratovalna_navodila_za_prenosni_eles_in_distribucijski_sistem.pdf accessed 2026-09-21]

Final sizing depends on PV array DC capacity, string configuration and the project-specific DSO connection offer.

## 2. Product scope (this page)

| Item | Value | Source |
| --- | --- | --- |
| Product type | On-grid / grid-tied solar PV inverter (string topology, transformerless) | Sungrow SG50CX datasheet (2023-12-19 rev.) |
| Reference candidate | Sungrow SG50CX — 50 kW three-phase string inverter | https://www.sungrowpower.com/UploadFile/file/20231219/20231219100826_10304.pdf |
| Alternative candidate | Huawei SUN2000-50KTL-M3 — 50 kW three-phase string inverter | https://solar.huawei.com/en-Hans/download?p=%2Fproducts%2FfusionSolar%2Fsun2000-50ktl-m3 |
| AC nominal output | 50 kW | Sungrow SG50CX datasheet, p.2; Huawei SUN2000-50KTL-M3 datasheet |
| Phases / grid | 3-phase, 400 V AC (Slovenia low-voltage) | Sungrow SG50CX datasheet, p.2; SODO connection-rules document |
| Topology | Transformerless | Sungrow SG50CX datasheet, p.1 |
| MPPT inputs | 5 MPPT (SG50CX) / 4 MPPT (SUN2000-50KTL-M3) | OEM datasheets |
| Typical use | Commercial / industrial rooftop PV (hangar) BoS | Sungrow SG50CX datasheet, p.1 |
| Origin | China (CN-OEM) | Manufacturer websites |
| Destination | Slovenia (EU) | SODO |

## 3. TCO summary (scenario model output, VERBATIM)

TCO summary | Metric | Value |
| --- | --- |
| Currency | EUR |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (EUR) | 118,045.45 |
| Total discounted cost / PV of costs (EUR) | 89,011.05 |
| Total undiscounted benefit (EUR) | 352,195.86 |
| Total discounted benefit (EUR) | 142,103.67 |
| NPV (EUR) | 53,092.62 |
| IRR | 0.1546 |
| Simple payback (year) | 6.58 |
| Discounted payback (year) | 9.53 |
| LCOE (EUR/kWh) | 0.1259 |

## 4. Year-by-year cash flow (scenario model output, VERBATIM)

Year-by-year cash flow | Year | Cost (EUR) | Benefit (EUR) | Net (EUR) | Discount factor | Discounted net (EUR) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 70,000.00 | 0.0000 | -70,000.00 | 1.00 | -70,000.00 | 0.0000 |
| 1 | 1,500.00 | 11,730.00 | 10,230.00 | 0.9259 | 9,472.22 | 69,000.00 |
| 2 | 1,530.00 | 11,904.78 | 10,374.78 | 0.8573 | 8,894.70 | 68,655.00 |
| 3 | 1,560.60 | 12,082.16 | 10,521.56 | 0.7938 | 8,352.35 | 68,311.73 |
| 4 | 1,591.81 | 12,262.18 | 10,670.37 | 0.7350 | 7,843.04 | 67,970.17 |
| 5 | 1,623.65 | 12,444.89 | 10,821.24 | 0.6806 | 7,364.75 | 67,630.32 |
| 6 | 1,656.12 | 12,630.32 | 10,974.20 | 0.6302 | 6,915.61 | 67,292.16 |
| 7 | 1,689.24 | 12,818.51 | 11,129.27 | 0.5835 | 6,493.82 | 66,955.70 |
| 8 | 1,723.03 | 13,009.51 | 11,286.48 | 0.5403 | 6,097.73 | 66,620.92 |
| 9 | 1,757.49 | 13,203.35 | 11,445.86 | 0.5002 | 5,725.78 | 66,287.82 |
| 10 | 1,792.64 | 13,400.08 | 11,607.44 | 0.4632 | 5,376.49 | 65,956.38 |
| 11 | 1,828.49 | 13,599.74 | 11,771.25 | 0.4289 | 5,048.49 | 65,626.60 |
| 12 | 1,865.06 | 13,802.37 | 11,937.31 | 0.3971 | 4,740.47 | 65,298.47 |
| 13 | 1,902.36 | 14,008.03 | 12,105.67 | 0.3677 | 4,451.23 | 64,971.97 |
| 14 | 1,940.41 | 14,216.75 | 12,276.34 | 0.3405 | 4,179.62 | 64,647.11 |
| 15 | 1,979.22 | 14,428.58 | 12,449.36 | 0.3152 | 3,924.56 | 64,323.88 |
| 16 | 2,018.80 | 14,643.56 | 12,624.76 | 0.2919 | 3,685.05 | 64,002.26 |
| 17 | 2,059.18 | 14,861.75 | 12,802.57 | 0.2703 | 3,460.14 | 63,682.25 |
| 18 | 2,100.36 | 15,083.19 | 12,982.83 | 0.2502 | 3,248.94 | 63,363.84 |
| 19 | 2,142.37 | 15,307.93 | 13,165.56 | 0.2317 | 3,050.62 | 63,047.02 |
| 20 | 2,185.22 | 15,536.02 | 13,350.80 | 0.2145 | 2,864.39 | 62,731.78 |
| 21 | 2,228.92 | 15,767.51 | 13,538.59 | 0.1987 | 2,689.52 | 62,418.12 |
| 22 | 2,273.50 | 16,002.44 | 13,728.94 | 0.1839 | 2,525.31 | 62,106.03 |
| 23 | 2,318.97 | 16,240.88 | 13,921.91 | 0.1703 | 2,371.11 | 61,795.50 |
| 24 | 2,365.35 | 16,482.87 | 14,117.52 | 0.1577 | 2,226.32 | 61,486.52 |
| 25 | 2,412.66 | 16,728.46 | 14,315.81 | 0.1460 | 2,090.36 | 61,179.09 |

## 5. Model assumptions (bounded defaults — replace per project)

**Inputs the draft did not state. The scenario model used these bounded defaults:**

- `asset.pv.degradation_pct_per_year` = 0.50 %/yr (linear annual module degradation; consistent with Sungrow PV module warranty terms referenced in the SG50CX datasheet pack). Bounded by [0.0, 1.5] %/yr.

- `asset.pv.tariff_escalation_pct` = 1.50 %/yr (annual self-consumed/exported tariff escalation, nominal). Bounded by [0.0, 5.0] %/yr.

- `residual_value.amount` = 0 EUR (no terminal salvage value booked; inverter replaced in year 25).

- `residual_value.year` = 25 (end of horizon).

Replace each default with a buyer-specific value before procurement reliance.

## 6. Equipment reference candidates (real, publicly marketed)

| Candidate | Family / Model | Public source |
| --- | --- | --- |
| Primary reference | Sungrow SG50CX (50 kW, 3-phase 400 V, transformerless, 5 MPPT) | Sungrow SG50CX datasheet: https://www.sungrowpower.com/UploadFile/file/20231219/20231219100826_10304.pdf |
| Alternative reference | Huawei SUN2000-50KTL-M3 (50 kW, 3-phase 400 V, transformerless, 4 MPPT) | Huawei SUN2000-50KTL-M3 product page: https://solar.huawei.com/en-Hans/products/FusionSolar/SUN2000-50KTL-M3 |
| Product family (Sungrow commercial string) | Sungrow SGxxCX commercial string series | https://www.sungrowpower.com/Product/index/id/3.html |
| Product family (Huawei commercial string) | Huawei SUN2000-50/60KTL-M3 commercial series | https://solar.huawei.com/en-Hans/Products/FusionSolar |

Final OEM model and serial confirmed per datasheet and Declaration of Conformity delivered with the RFQ response. No certificate number, OEM logo or marketing claim is asserted on this page.

## 7. Compliance & certifications to verify on the datasheet

| Requirement | What to check | Reference document |
| --- | --- | --- |
| CE marking (EU) | CE mark + EU Declaration of Conformity referencing LVD, EMC, RoHS | EU Regulation (EU) 2019/1020 (market surveillance) — EUR-Lex: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32019R1020 |
| Safety of PV power converters | EN / IEC 62109-1 and 62109-2 referenced on datasheet / DoC | IEC 62109-1:2010 product page: https://webstore.iec.ch/publication/6451 ; IEC 62109-2:2011 product page: https://webstore.iec.ch/publication/6452 |
| Utility interconnect characteristics | IEC 61727 referenced on datasheet / DoC | IEC 61727:2004 product page: https://webstore.iec.ch/publication/2411 |
| Anti-islanding protection | IEC 62116 referenced on datasheet / DoC | IEC 62116:2014 product page: https://webstore.iec.ch/publication/22281 |
| Slovenian grid compliance | Conformance with project-specific SODO connection requirements | SODO Sistemska obratovalna navodila: https://www.sodo.si/dokumenti/Sistemska_obratovalna_navodila_za_prenosni_eles_in_distribucijski_sistem.pdf |
| Product warranty | Years and conditions stated on datasheet | Sungrow SG50CX datasheet, p.1 (5-year standard, extendable to 10 years) |

**Disclaimer:** tradvolt does not state or imply that any specific inverter carries any specific certificate. Certificate numbers, issuing body and validity must be verified against the OEM Declaration of Conformity before order.

## 8. Duty & VAT stack — Slovenia (EU)

**HS national line | As-of: 2026-09-21 | SoT: PENDING**
Every duty and VAT rate below is marked `PENDING — lookup`. The official sources of truth are the EU TARIC consultation (per HS code) and the Slovenian Customs Administration (FURS — Finančna uprava Republike Slovenije). The HS code for the inverter must be confirmed before any rate is applied.

| Component | Base | Rate | As-of | Source of truth |
| --- | --- | --- | --- | --- |
| EU import duty (Slovenia) | CIF value | PENDING — lookup | 2026-09-21 | EU TARIC measure query (CN 2026-09-21): https://ec.europa.eu/taxation_customs/dds2/taric/measures.html?codes=850440 ; EU TARIC consultation: https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp |
| Anti-dumping / safeguard measures (if applicable to the HS code) | CIF value | PENDING — lookup | 2026-09-21 | DG TAXUD Trade defence measures page: https://policy.trade.ec.europa.eu/enforcement-and-protection/trade-defence_en |
| Slovenian VAT (DDV) | Customs value + duty | PENDING — lookup | 2026-09-21 | FURS DDV rate publication: https://www.fu.gov.si/davki_in_druge_dajatve/podrocja/ddv/ddv_znacilne_stopnje/ ; Slovenian VAT Act (ZDDV-1): https://www.uradni-list.si/glasilo-uradni-list-rs/vsebina/2006-01-4096 |
| Excise / environmental levies | n/a for solar inverter | Not applicable — confirm | 2026-09-21 | FURS Customs tariff & levies: https://www.fu.gov.si/carinske_dajatve/ |

HS-code-dependent: the rate for static converters (which includes grid-tied PV inverters) is HS-code-dependent and may be subject to anti-dumping or surveillance measures for specific sub-codes. Always re-check TARIC at quote stage.

## 9. Request a quote (RFQ) — replies in 48h

Submit the form below. tradvolt replies within 48 hours with an OEM shortlist, indicative FOB/CIF/DAP Slovenia price range and a working datasheet. No payment is taken at this stage.

Or open the standard RFQ form: [/rfq/](/rfq/).

## 10. FAQ

### Is a single 50 kW inverter a typical match for a hangar rooftop in Slovenia?

Yes. A 50 kW three-phase string inverter (e.g. Sungrow SG50CX) is a standard commercial-scale building block. Final sizing must be validated against array kWp and the project-specific SODO connection offer. [Src: Sungrow SG50CX datasheet, https://www.sungrowpower.com/UploadFile/file/20231219/20231219100826_10304.pdf accessed 2026-09-21]

### Which EU/IEC certifications should be checked on the datasheet before RFQ?

Verify CE marking and references to IEC 62109-1/-2 (safety), IEC 61727 (utility interface) and IEC 62116 (anti-islanding) on the datasheet and Declaration of Conformity. Slovenian grid compliance is project-specific. [Src: IEC webstore publication pages, https://webstore.iec.ch/publication/6451 ; https://webstore.iec.ch/publication/6452 ; https://webstore.iec.ch/publication/2411 ; https://webstore.iec.ch/publication/22281 accessed 2026-09-21]

### How is the import duty and VAT stack built for Slovenia?

The stack is built on the EU TARIC / Slovenian national line for the inverter HS code. Official portals: European Commission TARIC consultation and FURS. Until the exact HS code is verified, every duty and VAT rate on this page is marked PENDING — lookup. [Src: EU TARIC consultation, https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp ; FURS, https://www.fu.gov.si/ accessed 2026-09-21]

### What does the scenario TCO model show for this scenario?

Over 25 years at an 8% discount rate: NPV = EUR 53,092.62; simple payback = 6.58 yr; discounted payback = 9.53 yr; LCOE = EUR 0.1259/kWh; IRR = 15.46%. Subject to the bounded defaults in §5.

### Can tradvolt ship DAP Slovenia with a working datasheet?

Yes. RFQs can be issued on EXW, FOB, CIF, DAP Slovenia and DDP Slovenia. The OEM datasheet and Declaration of Conformity are delivered with the RFQ response.

### What is not included in the TCO shown on this page?

Excludes PV modules, racking, DC cabling, AC balance-of-system, SODO connection fees, structural reinforcement for the hangar roof, and any anti-dumping or safeguard measures that may apply at import.

[Request Quote — replies in 48h](#rfq) [Open RFQ form](/rfq/)

**Claim rows — sources reviewed (access date 2026-09-21).** Every factual claim on this page ties to the following specific document URLs.

[Claim: "Sungrow SG50CX is a 50 kW three-phase transformerless string inverter with 5 MPPT and 400 V AC output." Src: Sungrow SG50CX datasheet PDF, https://www.sungrowpower.com/UploadFile/file/20231219/20231219100826_10304.pdf] [Claim: "Huawei SUN2000-50KTL-M3 is a 50 kW three-phase transformerless string inverter." Src: Huawei SUN2000-50KTL-M3 product page, https://solar.huawei.com/en-Hans/products/FusionSolar/SUN2000-50KTL-M3] [Claim: "Safety of PV power converters is covered by IEC 62109-1 and 62109-2." Src: IEC 62109-1 publication page, https://webstore.iec.ch/publication/6451 ; IEC 62109-2 publication page, https://webstore.iec.ch/publication/6452] [Claim: "PV utility interface and anti-islanding requirements are IEC 61727 and IEC 62116." Src: IEC 61727 publication page, https://webstore.iec.ch/publication/2411 ; IEC 62116 publication page, https://webstore.iec.ch/publication/22281] [Claim: "EU market surveillance framework is Regulation (EU) 2019/1020." Src: EUR-Lex Regulation (EU) 2019/1020, https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32019R1020] [Claim: "Slovenia uses SODO for distribution grid rules and connection offers." Src: SODO Sistemska obratovalna navodila, https://www.sodo.si/dokumenti/Sistemska_obratovalna_navodila_za_prenosni_eles_in_distribucijski_sistem.pdf] [Claim: "Official Slovenian customs / indirect-tax authority is FURS." Src: FURS DDV rate page, https://www.fu.gov.si/davki_in_druge_dajatve/podrocja/ddv/ddv_znacilne_stopnje/ ; FURS customs duties page, https://www.fu.gov.si/carinske_dajatve/] [Claim: "EU import duty and measures are queryable per HS code on TARIC." Src: EU TARIC consultation, https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp ; TARIC measures lookup, https://ec.europa.eu/taxation_customs/dds2/taric/measures.html] [Claim: "Specific annual PV yield figures for Slovenia are obtained from PVGIS." Src: PVGIS interactive tool, https://re.jrc.ec.europa.eu/pvg_tools/en/] [Claim: "UN Manual of Tests classifies inverters as Class 9 dangerous goods only when lithium-containing; a standalone 50 kW PV inverter without internal lithium is not DG by default." Src: UN Recommendations on the Transport of Dangerous Goods — Manual of Tests and Criteria, https://www.unece.org/fileadmin/DAM/trans/danger/publi/manual/Rev7/Manual7.htm]

No blog, forum, AI-generated, aggregator or anonymous source has been used. No specific certificate number, OEM logo or marketing claim is asserted on this page. Any such number is marked PENDING and will only be supplied from the OEM datasheet and DoC delivered with the RFQ response.