title: "Import 50 kW On-Grid Inverter from China to Vietnam — Hangar Rooftop TCO & Landed Cost | Tradvolt"
source_url: "https://tradvolt.com/en/tco/import-50-kw-on-grid-inverter-from-china-to-vietnam-hangar-rooftop-tco-landed-cost-tradvolt/"
lang: "en"
description: "B2B TCO and landed-cost reference for importing a Sungrow SG50CX-P2-CN on-grid string inverter from China to Vietnam for a hangar-rooftop PV project. NPV, IRR, payback, LCOE, HS/duty stack and RFQ."
generator: "tradvolt-tier-c-edge-md"
---

**Verdict — invest.** A 50 kW grid-tied PV installation on a south-central Vietnam hangar, anchored on a Sungrow SG50CX-P2-CN string inverter and Jinko Solar JKM620N-78HL4-BDV modules, returns **NPV = USD 13,949.24** at an 8.00 % discount rate over a 25-year horizon, with **simple payback 8.67 yr**, **discounted payback 14.73 yr**, **IRR 11.22 %** and **LCOE USD 0.0696 /kWh**. Equipment: Sungrow SG50CX-P2-CN inverter (50 kW AC, 3-phase 400 V, 50 Hz). Location: south-central Vietnam hangar rooftop. Horizon: 25 yr. Evidence date: 2026-09-21. Limitation: yields are NASA POWER / PVGIS-class long-term averages, self-consumption share and EVN tariff are bounded model assumptions; duty/VAT are PENDING GDVC lookup — not a quote.

Decision snapshot — 50 kW on-grid, hangar rooftop, VN | Metric | Value | Note |
| --- | --- | --- |
| Equipment (BoS anchor) | Sungrow SG50CX-P2-CN, 50 kW, 3-ph 400 V | OEM datasheet cited below |
| Modules | Jinko Solar JKM620N-78HL4-BDV (≈620 Wp mono) | OEM datasheet cited below |
| Location | South-central Vietnam (≈12 °N) | PVGIS / NASA POWER class |
| Horizon | 25 years | Model horizon |
| Discount rate | 8.00 % | Bounded model assumption |
| NPV | USD 13,949.24 | PV(benefit) − PV(cost) |
| IRR | 11.22 % | Project IRR |
| Simple payback | 8.67 yr | Undiscounted |
| Discounted payback | 14.73 yr | At 8.00 % |
| LCOE | USD 0.0696 /kWh | PV(cost) ÷ PV(generation) |
| Decision | **Proceed** | Subject to RFQ + GDVC duty confirmation |

# Import a Sungrow SG50CX-P2-CN On-Grid Inverter from China to Vietnam — Hangar-Rooftop TCO & Landed Cost

A B2B reference page for solar EPCs and industrial-rooftop owners sizing a 50 kW grid-tied PV installation on a hangar in Vietnam. It structures CapEx, OpEx, payback and sensitivity around the Sungrow SG50CX-P2-CN string inverter as the BoS anchor, with an explicit duty-stack block against the Vietnam Customs (GDVC) tariff.

**Use-case**Hangar rooftop 50 kW **Inverter**Sungrow SG50CX-P2-CN **Origin**China (CN) **Destination**Vietnam (VN) **As-of**2026-09-21   [Request Quote — replies in 48h](/rfq/?sku=INV-50K-ONGRID-SG50CX-P2-CN) [OEM datasheet pack (PDF)](https://en.sungrowpower.com/Public/Uploads/uploadfiles/files/20240710/SG50CX-P2-CN_Datasheet.pdf)

## 1. Use case — Hangar rooftop, 50 kW on-grid

A typical industrial hangar in Vietnam presents a low-slope metal deck with limited shading and high load-bearing capacity. A 50 kW grid-tied PV system fits as a self-consumption + surplus-export asset behind a single three-phase 400 V AC connection point, feeding a warehouse or small-assembly load during daylight. The inverter is the BoS anchor: its AC output, MPPT range, ingress protection and grid-compliance evidence drive the rest of the procurement logic.

### Equipment selection — exact models

| Function | Model | OEM | Public datasheet / product page |
| --- | --- | --- | --- |
| On-grid string inverter (BoS anchor) | Sungrow SG50CX-P2-CN | Sungrow Power Supply Co., Ltd. | SG50CX-P2-CN Datasheet (PDF); product index Sungrow string inverter range |
| PV modules (~620 Wp mono) | Jinko Solar JKM620N-78HL4-BDV (Tiger Neo) | Jinko Solar Co., Ltd. | JKM620N-78HL4-BDV Datasheet (PDF) |
| Mounting structure (metal-roof, non-penetrative) | K2 Systems S-Dome 6.10 (clamped rail, trapezoidal sheet) | K2 Systems GmbH | K2 Systems (mounting) |
| Yield source (irradiation, south-central VN) | NASA POWER — Prediction of Worldwide Energy Resource (POWER) project, hourly/meteorology surface | NASA Langley Research Center | NASA POWER project; PVGIS cross-check PVGIS (JRC) |
| EVN reference (grid, tariff framework) | Vietnam Electricity (EVN) — group portal | EVN | EVN corporate portal |

Inverter limits (torque / SOC / voltages) must be read against the Sungrow SG50CX-P2-CN datasheet revision linked above; module limits against the JKM620N-78HL4-BDV revision linked above. No third-party logos or "No.1" claims are reproduced on this page.

### Site & load assumptions (inputs)

| Parameter | Value | Unit | Source / evidence |
| --- | --- | --- | --- |
| DC system size (modules) | ~62.5 | kWp | Model assumption — DC/AC ratio 1.25 against 50 kW AC (Sungrow SG50CX-P2-CN rated AC output) |
| Inverter AC output | 50 | kW | Sungrow SG50CX-P2-CN datasheet — rated AC output 50 kW |
| Grid interface | 3-phase, 400 V, 50 Hz | — | Sungrow SG50CX-P2-CN datasheet — grid interface |
| Annual specific yield (PLAN) | ~1,350 | kWh/kWp/yr | Model assumption — south-central VN long-term average; cross-check vs. NASA POWER and PVGIS (JRC) |
| Annual generation | 84,375 (Year-1) | kWh/yr | Computed = 62.5 × 1,350 (Year-1); degrades 0.5 %/yr |
| Self-consumption share | 70 | % | Model assumption — daytime warehouse load |

Numbers labelled ILLUSTRATIVE — NOT A QUOTE.

## 2. CapEx — inverter-anchored landed cost

CapEx is built around the inverter (BoS anchor) plus modules, mounting, DC/AC cabling, protection, freight/logistics from China to Vietnam, and import duty + VAT (duty/VAT cell is PENDING until the GDVC lookup is recorded against the accessed date).

| Line item | Qty | Unit | Unit price (USD) | Subtotal (USD) | Source / evidence |
| --- | --- | --- | --- | --- | --- |
| Sungrow SG50CX-P2-CN inverter (BoS anchor) | 1 | pcs | RFQ | RFQ | SG50CX-P2-CN datasheet (PDF) |
| Jinko JKM620N-78HL4-BDV modules (~620 Wp) | ~101 | pcs | RFQ | RFQ | JKM620N-78HL4-BDV datasheet (PDF) |
| K2 Systems S-Dome 6.10 mounting (metal-roof, non-penetrative) | 1 | lot | RFQ | RFQ | K2 Systems mounting |
| DC cabling, MC4 connectors, AC cabling | 1 | lot | RFQ | RFQ | IEC 62930 Ed.1 |
| DC/AC protection (SPD Type II, MCB, RCD, isolators) | 1 | lot | RFQ | RFQ | IEC 61643-11 Ed.1 |
| Smart / export meter | 1 | pcs | RFQ | RFQ | Utility-approved meter per local EVN/PC |
| EPC install + commissioning (labour) | 1 | lot | RFQ | RFQ | EPC scope |
| Ocean freight CN → VN (FOB or CIF) | 1 | lot | RFQ | RFQ | Incoterms 2020 (ICC) |
| Marine insurance (~0.3 % CIF) | 1 | lot | RFQ | RFQ | Insurer quote |
| Import duties + VAT (Vietnam) | 1 | lot | PENDING — GDVC lookup | PENDING — GDVC lookup | Vietnam Customs (GDVC), tariff search customs.gov.vn — Tariff enquiry, accessed 2026-09-21 |
| Customs broker + port handling (THC) | 1 | lot | RFQ | RFQ | Broker quote |

All unit prices RFQ. The duty / VAT row must be replaced with the figure returned by the official Vietnam Customs (GDVC) tariff lookup; see §7.

## 3. OpEx — 25-year operating view

OpEx is dominated by routine O&M, insurance, a small spare-parts reserve, and an inverter replacement reserve. Modules and mounting are assumed maintenance-light. Numbers below are bounded model assumptions for the TCO run; final OpEx must be re-quoted against the EPC scope.

| Line item | Year-1 (USD/yr) | Source / evidence |
| --- | --- | --- |
| Routine O&M (cleaning, inspection, monitoring) | 1,200 (escalates 2 %/yr) | Model assumption (bounded) — EPC scope |
| Insurance (~0.2 % of CapEx/yr) | included in OpEx schedule | Model assumption (bounded) — insurer quote |
| Spare parts / unplanned service reserve | included in OpEx schedule | Model assumption (bounded) — EPC scope |
| Inverter replacement reserve | not provisioned in cashflow | Model assumption (bounded) — see TCO summary inputs note |

Annual figures are bounded model assumptions for the TCO run; re-validate against EPC scope before procurement.

## 4. TCO summary — computed

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 83,436.36 |
| Total discounted cost / PV of costs (USD) | 60,208.84 |
| Total undiscounted benefit (USD) | 183,796.59 |
| Total discounted benefit (USD) | 74,158.08 |
| NPV (USD) | 13,949.24 |
| IRR | 0.1122 |
| Simple payback (year) | 8.67 |
| Discounted payback (year) | 14.73 |
| LCOE (USD/kWh) | 0.0696 |

### Year-by-year cash flow

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 45,000.00 | 0.0000 | -45,000.00 | 1.00 | -45,000.00 | 0.0000 |
| 1 | 1,200.00 | 6,121.41 | 4,921.41 | 0.9259 | 4,556.86 | 84,375.00 |
| 2 | 1,224.00 | 6,212.62 | 4,988.62 | 0.8573 | 4,276.93 | 83,953.12 |
| 3 | 1,248.48 | 6,305.18 | 5,056.70 | 0.7938 | 4,014.17 | 83,533.36 |
| 4 | 1,273.45 | 6,399.13 | 5,125.68 | 0.7350 | 3,767.53 | 83,115.69 |
| 5 | 1,298.92 | 6,494.48 | 5,195.56 | 0.6806 | 3,536.01 | 82,700.11 |
| 6 | 1,324.90 | 6,591.25 | 5,266.35 | 0.6302 | 3,318.69 | 82,286.61 |
| 7 | 1,351.39 | 6,689.45 | 5,338.06 | 0.5835 | 3,114.71 | 81,875.18 |
| 8 | 1,378.42 | 6,789.13 | 5,410.70 | 0.5403 | 2,923.24 | 81,465.80 |
| 9 | 1,405.99 | 6,890.29 | 5,484.29 | 0.5002 | 2,743.51 | 81,058.48 |
| 10 | 1,434.11 | 6,992.95 | 5,558.84 | 0.4632 | 2,574.82 | 80,653.18 |
| 11 | 1,462.79 | 7,097.15 | 5,634.35 | 0.4289 | 2,416.48 | 80,249.92 |
| 12 | 1,492.05 | 7,202.89 | 5,710.84 | 0.3971 | 2,267.85 | 79,848.67 |
| 13 | 1,521.89 | 7,310.22 | 5,788.33 | 0.3677 | 2,128.36 | 79,449.42 |
| 14 | 1,552.33 | 7,419.14 | 5,866.81 | 0.3405 | 1,997.42 | 79,052.18 |
| 15 | 1,583.37 | 7,529.68 | 5,946.31 | 0.3152 | 1,874.52 | 78,656.92 |
| 16 | 1,615.04 | 7,641.88 | 6,026.83 | 0.2919 | 1,759.18 | 78,263.63 |
| 17 | 1,647.34 | 7,755.74 | 6,108.40 | 0.2703 | 1,650.91 | 77,872.31 |
| 18 | 1,680.29 | 7,871.30 | 6,191.01 | 0.2502 | 1,549.29 | 77,482.95 |
| 19 | 1,713.90 | 7,988.58 | 6,274.69 | 0.2317 | 1,453.92 | 77,095.54 |
| 20 | 1,748.17 | 8,107.61 | 6,359.44 | 0.2145 | 1,364.41 | 76,710.06 |
| 21 | 1,783.14 | 8,228.42 | 6,445.28 | 0.1987 | 1,280.39 | 76,326.51 |
| 22 | 1,818.80 | 8,351.02 | 6,532.22 | 0.1839 | 1,201.54 | 75,944.88 |
| 23 | 1,855.18 | 8,475.45 | 6,620.27 | 0.1703 | 1,127.53 | 75,565.15 |
| 24 | 1,892.28 | 8,601.73 | 6,709.45 | 0.1577 | 1,058.08 | 75,187.33 |
| 25 | 1,930.12 | 8,729.90 | 6,799.78 | 0.1460 | 992.89 | 74,811.39 |

## 5. Payback & sensitivity

Figures below are labelled **ILLUSTRATIVE — NOT A QUOTE**. They use the placeholder CapEx and OpEx schedule that produces the TCO summary above (NPV USD 13,949.24, simple payback 8.67 yr, discounted payback 14.73 yr). Self-consumption tariff, export tariff, OpEx escalation, module degradation and residual value are bounded model assumptions.

### Bounded model inputs

| All-in CapEx (incl. freight + duty placeholder) | USD 45,000 | Model assumption (bounded) — Year-0 spend |
| --- | --- | --- |
| Year-1 OpEx | USD 1,200 | Model assumption (bounded) — escalates 2 %/yr |
| Year-1 generation | 84,375 kWh | 62.5 kWp × 1,350 kWh/kWp; degrades 0.5 %/yr |
| Self-consumption share | 70 % | Model assumption (bounded) |
| Self-consumed electricity tariff (Year 1, blended) | USD 0.0725 /kWh (model blended tariff equivalent) | Bounded model assumption; cross-check vs. EVN corporate portal |
| Export tariff (surplus, Year 1) | USD 0.0435 /kWh | Bounded model assumption; cross-check vs. EVN corporate portal |
| Tariff escalation | 2.0 %/yr | Model assumption (bounded) |
| Module degradation | 0.5 %/yr | Model assumption (bounded) |
| Residual value | USD 0 (year N/A) | Model assumption (bounded) — year/end not specified |
| Inverter replacement reserve | DROPPED — not provisioned in cashflow | Model assumption (bounded) — explicit drop note |

Bounded model inputs are explicit model assumptions, not sourced facts; they must be re-validated for the specific hangar-rooftop site and the specific OEM model selected via the RFQ.

### Sensitivity (simple payback, years)

Recomputed against the bounded inputs (Year-1 generation 84,375 kWh, self-consumption share 70 %, blended tariff 0.0725 USD/kWh, export tariff 0.0435 USD/kWh, Year-1 OpEx 1,200 USD). Tariff column = blended self-consumption tariff in USD/kWh.

| All-in CapEx \ Self-consumption tariff | USD 0.0600/kWh | USD 0.0725/kWh | USD 0.0850/kWh |
| --- | --- | --- | --- |
| USD 38,000 | 8.81 | 7.43 | 6.40 |
| USD 45,000 | 10.30 | 8.67 | 7.46 |
| USD 52,000 | 11.78 | 9.91 | 8.52 |

Sensitivity holds generation (84,375 kWh/yr), self-consumption share (70 %), export tariff (0.0435 USD/kWh) and OpEx (1,200 USD/yr, 2 %/yr escalation) constant; only CapEx and self-consumption tariff move. ILLUSTRATIVE — NOT A QUOTE.

## 6. Compliance & certifications

| Standard / mark | Scope | Acceptable issuers (allow-list) | Public reference |
| --- | --- | --- | --- |
| IEC 62109-1 / -2 | Power converter safety | TÜV Rheinland, TÜV SÜD, VDE, UL LLC, CSA Group | IEC 62109-1:2010 (TC 82); IEC 62109-2:2011 (TC 82) |
| IEC 61727 / IEC 62116 | Grid compliance (anti-islanding, harmonic, FRT) | TÜV Rheinland, TÜV SÜD, DNV | IEC 61727 Ed.2; IEC 62116 Ed.2 |
| CE marking | EU Declaration of Conformity issued by OEM | OEM-issued DoC, notified body report referenced | EU Regulation (EU) 2019/1020, EUR-Lex CE / market surveillance |
| IP rating (≥ IP65 outdoor) | Ingress protection | IEC 60529 test report from accredited lab | IEC 60529 Ed.2.2 |
| Vietnam grid acceptance | Local utility type-test / connection agreement | Regional power company (EVN / PC) | EVN corporate portal |
| UN transport (battery / dangerous goods if any storage) | UN Manual of Tests and Criteria for lithium cells (UN 38.3) | UN publication | UN Manual of Tests and Criteria (UNECE) |

No logo, certificate number or "No.1" claim is reproduced on this page. All certificate numbers and issuer names must be verified from the OEM certificate PDF before procurement.

## 7. Duty / HS stack — Vietnam import

**Duty-stack block header**
`HS national line | Program | As-of: 2026-09-21 | SoT: PENDING`
Mark every duty/VAT rate `PENDING — lookup`. Official portal: **Vietnam Customs — General Department of Vietnam Customs (GDVC)**, tariff enquiry: [https://www.customs.gov.vn/index.jsp?pageId=8](https://www.customs.gov.vn/index.jsp?pageId=8). Exact HS national line: `PENDING — lookup` (likely candidate: 8504.40.90 — static converters, heading 8504, chapter 85; final line to be confirmed via the GDVC tariff search).

| Component | Rate | Notes / SoT |
| --- | --- | --- |
| Import duty (MFN) — inverter | PENDING — lookup | SoT: Vietnam Customs (GDVC) tariff enquiry, https://www.customs.gov.vn/index.jsp?pageId=8, accessed 2026-09-21; candidate heading 8504 |
| Import duty (preferential) — ASEAN / EVFTA / RCEP | PENDING — lookup | SoT: GDVC preferential tariff schedule, accessed 2026-09-21; C/O eligibility PENDING — lookup. EVFTA text reference: EU-Vietnam FTA (EUR-Lex) |
| VAT | PENDING — lookup | SoT: GDVC tariff page + General Department of Taxation, accessed 2026-09-21 |
| Special consumption tax (SCT) | PENDING — lookup | SoT: GDVC, accessed 2026-09-21; inverters typically not in SCT scope but verify per HS line |
| Other (environmental, recycling fee) | PENDING — lookup | SoT: GDVC, accessed 2026-09-21 |

No rate is hardcoded. Final landed duty + VAT cell in the CapEx table must be replaced with the figure returned by the official GDVC lookup, with the accessed date recorded.

## 8. Request a quote

Submit the form below. Tradvolt replies within **48 hours** with OEM availability for the Sungrow SG50CX-P2-CN, a firm FOB / CIF price, lead time, and the certificate pack (IEC 62109 / IEC 61727 / IEC 62116, CE DoC, IP test report).

[Request Quote — replies in 48h](/rfq/?sku=INV-50K-ONGRID-SG50CX-P2-CN) [OEM datasheet pack (PDF)](https://en.sungrowpower.com/Public/Uploads/uploadfiles/files/20240710/SG50CX-P2-CN_Datasheet.pdf)

## 9. Frequently asked questions

**What HS code applies to a Sungrow SG50CX-P2-CN imported into Vietnam?**

Candidate national line 8504.40.90 (static converters) under heading 8504, chapter 85, per Vietnam Customs (GDVC) tariff nomenclature. The exact national line, MFN rate and any EVFTA / RCEP preferential rate must be confirmed at the live GDVC tariff enquiry page ([https://www.customs.gov.vn/index.jsp?pageId=8](https://www.customs.gov.vn/index.jsp?pageId=8)) before procurement.

**Do Vietnamese projects require EVN grid-interconnection approval?**

Yes. Rooftop grid-tied systems require a grid connection agreement with the regional power company (EVN / regional PC). Final scope of approval is confirmed with the buyer's local utility; the public framework is set out by EVN ([https://www.evn.com.vn/](https://www.evn.com.vn/)).

**Which certifications should be requested for a Sungrow SG50CX-P2-CN used in Vietnam?**

Commonly accepted evidence: IEC 62109-1/-2 (safety, [IEC 62109-1](https://webstore.iec.ch/en/publication/6470) / [IEC 62109-2](https://webstore.iec.ch/en/publication/6471)), IEC 61727 / IEC 62116 (grid compliance, anti-islanding), issued by accredited CBs such as TÜV Rheinland or TÜV SÜD, and a CE Declaration of Conformity issued by the OEM. Vietnam-specific utility type-test acceptance is confirmed with the local EVN/PC.

**Is the payback shown on this page a quote?**

No. The payback, sensitivity, NPV, IRR and LCOE figures are ILLUSTRATIVE — NOT A QUOTE. They depend on the inverter OEM model (Sungrow SG50CX-P2-CN), FOB/CIF price, freight, duty/VAT, irradiation, EVN tariff and financing assumptions that must be re-validated for the specific hangar-rooftop site via the RFQ.

**What Incoterm should be used for CN → VN inverter procurement?**

Common choices: FOB Shanghai / Ningbo / Shenzhen (buyer arranges ocean freight and insurance) or CIF Hai Phong / Da Nang / Cat Lai (seller arranges freight to named Vietnamese port), per [ICC Incoterms 2020](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/). CIF is convenient for a first import; FOB gives the buyer cost control. The selected Incoterm must be entered in the RFQ form.

**Can Tradvolt provide a Vietnamese-language datasheet?**

The OEM datasheet for the Sungrow SG50CX-P2-CN is provided in English ([SG50CX-P2-CN datasheet, PDF](https://en.sungrowpower.com/Public/Uploads/uploadfiles/files/20240710/SG50CX-P2-CN_Datasheet.pdf)). A Vietnamese translation, if required, is typically prepared by the importer for local utility submission and is not included by default.