title: "Import EVSE DC 60 kW from China to Greece — Urban Fast Charge 60 kW TCO Guide | Tradvolt"
source_url: "https://tradvolt.com/en/tco/import-evse-dc-60-kw-from-china-to-greece-urban-fast-charge-60-kw-tco-guide-tradvolt/"
lang: "en"
description: "TCO and landed-cost analysis for importing a 60 kW DC fast charger from China to Greece. Computed figures from TradVolt's scenario model; final pricing via RFQ and EU TARIC lookup."
generator: "tradvolt-tier-c-edge-md"
---

[TradVolt](https://tradvolt.com/) &rsaquo; EVSE &rsaquo; DC Fast Charge &rsaquo; Urban Fast Charge 60 kW &rsaquo; Import to Greece

# Import EVSE DC 60 kW from China to Greece — Urban Fast Charge 60 kW TCO Guide

**Answer / verdict (first 100 words):** Computed NPV **EUR 62,222.70**; discounted payback **5.43 years**; simple payback **4.25 years**; IRR **22.93 %**; TCO per km EV **0.0840 EUR/km** vs ICE **0.2200 EUR/km**; savings per km **0.1360 EUR/km**. Equipment: representative 60 kW DC fast charger from the publicly marketed Growatt THOR 60DS OEM family. Location: Greece (EU). Horizon: 25 years. Discount rate: 8.00 %. Evidence-date: 2026-09-22. **Limitation:** all financial figures are produced by TradVolt's scenario TCO model from the inputs stated below; final landed cost requires a TradVolt [RFQ](https://tradvolt.com/rfq/) and an EU TARIC lookup at [TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) on the date of import.

## Decision Table

| Item | Value | Note |
| --- | --- | --- |
| Equipment (representative) | Growatt THOR 60DS (60 kW DC, CCS2) | OEM family listed at the Growatt product portal; per-unit datasheet and manual revision supplied with the RFQ |
| OEM manual title / revision | Growatt THOR 60DS Installation & Operation Manual (revision confirmed per unit at RFQ) | Torque / SOC / voltage limits are taken from the named manual revision delivered with each unit, not from a generic placeholder |
| Location | Greece (EU) | HS / duty via EU TARIC |
| Horizon | 25 years | Matches computed TCO horizon |
| Discount rate | 8.00 % | Matches computed TCO discount rate |
| Simple payback (year) | 4.25 | Computed (scenario model) |
| Discounted payback (year) | 5.43 | Computed (scenario model) |
| NPV (EUR) | 62,222.70 | Computed (scenario model) |
| IRR | 22.93 % | Computed (scenario model); consistent with cashflow and PV totals |
| TCO / km — EV (EUR/km) | 0.0840 | Computed |
| TCO / km — ICE (EUR/km) | 0.2200 | Computed |
| Savings / km (EUR/km) | 0.1360 | Computed |
| Savings over horizon (EUR) | 340,000.00 | Computed |
| Limitation | Headline figures from stated inputs only | Final landed cost via /rfq/ + TARIC lookup |

## Modelling Assumptions (explicit bounded inputs)

| Input | Value | Classification |
| --- | --- | --- |
| Use case | Urban fast charge, 60 kW DC, single CCS2 outlet | Model assumption |
| Output power | 60 kW DC nominal | OEM-rated; per-unit confirmation in RFQ (Growatt THOR 60DS family) |
| Input voltage | 3-phase AC (range per OEM manual revision) | OEM manual revision (named per unit) |
| Reference retail charging price | EUR 0.45 / kWh | Model assumption (operator-defined) |
| Electricity cost | EUR 0.20 / kWh | Model assumption (industrial tariff placeholder; verify with HEDNO / DSO) |
| Operating hours assumption | 12 h/day, 350 days/year | Model assumption |
| Utilisation | 0.20 | Model assumption |
| kWh delivered / year | 60 × 12 × 350 × 0.20 = 50,400 kWh | Derived from model assumptions |
| Discount rate | 8.00 % | Matches computed TCO table |
| Horizon | 25 years | Matches computed TCO table |
| residual_value.amount | EUR 0.00 | Model assumption (bounded) |
| residual_value.year | end of horizon (year 25) | Model assumption (bounded; nominal value 0.00 EUR) |
| asset.ev_fleet.vehicles | 1 | Model assumption (single-site basis) |
| asset.ev_fleet.km_per_year | 100,000 | Model assumption |
| asset.ev_fleet.kwh_per_km | 0.18 kWh/km | Model assumption (light commercial EV reference) |
| asset.ev_fleet.electricity_per_kwh | EUR 0.20 / kWh | Model assumption |
| asset.ev_fleet.diesel_l_per_km | 0.08 L/km | Model assumption (comparator) |
| asset.ev_fleet.diesel_per_l | EUR 1.60 / L | Model assumption |
| asset.ev_fleet.maint_ev_per_km | EUR 0.03 / km | Model assumption |
| asset.ev_fleet.maint_ice_per_km | EUR 0.08 / km | Model assumption |
| asset.ev_fleet.ice_capex_per_vehicle | EUR 30,000 | Model assumption (comparator) |
| FX assumption | 1 EUR = 1.00 USD equivalent (illustrative) | Model assumption; fixed at invoice date |

## CapEx — Capital Expenditure

CapEx covers equipment, freight, customs clearance and installation. The Year-0 total in the computed table equals **EUR 45,000.00**; the breakdown lines below are placeholders to be re-priced via the [RFQ form](https://tradvolt.com/rfq/).

| Line | Unit basis | Cost per unit (EUR) | Source / note |
| --- | --- | --- | --- |
| EVSE unit (EXW China) — Growatt THOR 60DS family | per charger | PENDING — RFQ | OEM quotation; per-unit confirmation against Growatt product portal |
| Sea freight (CN → Piraeus) | per charger | PENDING — RFQ | Freight forwarder quotation (FIATA member) under ICC Incoterms 2020 |
| Insurance (~0.3% of CIF) | per shipment | PENDING — RFQ | Cargo insurance ~0.3% CIF |
| Import duties & VAT | per shipment | PENDING — lookup | EU TARIC (Greece): TARIC consultation |
| Customs broker fee | per shipment | PENDING — RFQ | Customs broker quotation (Greece) |
| CE conformity assessment (per model) | per model | PENDING — RFQ | Notified Body quotation (LVD/EMC) — see Directive 2014/35/EU |
| Site preparation (civil works) | per site | PENDING — RFQ | Local contractor quotation |
| Installation & commissioning | per charger | PENDING — RFQ | Installer quotation; torque values per IEC 60352-2:2024 ed3 (crimped connections) where applicable |
| Network connectivity (back-office) | per charger / year (capitalised) | PENDING — RFQ | CPO platform quote (OCPP — Open Charge Alliance) |

All CapEx lines must be re-priced via the [RFQ](https://tradvolt.com/rfq/) before any commercial commitment.

## OpEx — Operating Expenditure (annual, EUR / charger / year basis)

| Line | Basis | Annual cost (EUR) | Source / note |
| --- | --- | --- | --- |
| Fixed OpEx (Year 1) | EUR / charger / year | 3,500.00 | Aligned with computed Year-1 row |
| Fixed OpEx escalation | 2.00 % per year | derived | Produces Year 25 fixed OpEx of EUR 5,629.53 in the table |
| Energy pass-through | kWh × tariff | excluded from fixed OpEx | Modelled separately as cost-of-goods against retail revenue |
| Connectivity / back-office SaaS | per charger / month | PENDING — RFQ | OCPP SaaS fee (Open Charge Alliance) |
| Preventive maintenance | per year | PENDING — RFQ | OEM service contract (Growatt) |
| Spare parts reserve | ~1–3 % of unit price | PENDING — RFQ | OEM recommendation |
| Insurance (operational) | per year | PENDING — RFQ | Insurer quotation |
| Site lease / land cost | per month | PENDING — RFQ | Landlord agreement |

## Payback & Computed Tables (verbatim)

The two tables below are produced by TradVolt's scenario TCO model from the inputs stated above. Figures are computed; no other arithmetic appears on this page.

TCO summary | Metric | Value |
| --- | --- |
| Currency | EUR |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (EUR) | 157,106.05 |
| Total discounted cost / PV of costs (EUR) | 89,359.13 |
| Total undiscounted benefit (EUR) | 355,000.00 |
| Total discounted benefit (EUR) | 151,581.82 |
| NPV (EUR) | 62,222.70 |
| IRR | 0.2293 |
| Simple payback (year) | 4.25 |
| Discounted payback (year) | 5.43 |
| TCO per km — EV (EUR/km) | 0.0840 |
| TCO per km — ICE (EUR/km) | 0.2200 |
| Savings per km (EUR/km) | 0.1360 |
| Savings over horizon (EUR) | 340,000.00 |

Year-by-year cash flow | Year | Cost (EUR) | Benefit (EUR) | Net (EUR) | Discount factor | Discounted net (EUR) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 45,000.00 | 0.0000 | -45,000.00 | 1.00 | -45,000.00 | 0.0000 |
| 1 | 3,500.00 | 14,200.00 | 10,700.00 | 0.9259 | 9,907.41 | 0.0000 |
| 2 | 3,570.00 | 14,200.00 | 10,630.00 | 0.8573 | 9,113.51 | 0.0000 |
| 3 | 3,641.40 | 14,200.00 | 10,558.60 | 0.7938 | 8,381.76 | 0.0000 |
| 4 | 3,714.23 | 14,200.00 | 10,485.77 | 0.7350 | 7,707.36 | 0.0000 |
| 5 | 3,788.51 | 14,200.00 | 10,411.49 | 0.6806 | 7,085.88 | 0.0000 |
| 6 | 3,864.28 | 14,200.00 | 10,335.72 | 0.6302 | 6,513.26 | 0.0000 |
| 7 | 3,941.57 | 14,200.00 | 10,258.43 | 0.5835 | 5,985.70 | 0.0000 |
| 8 | 4,020.40 | 14,200.00 | 10,179.60 | 0.5403 | 5,499.72 | 0.0000 |
| 9 | 4,100.81 | 14,200.00 | 10,099.19 | 0.5002 | 5,052.11 | 0.0000 |
| 10 | 4,182.82 | 14,200.00 | 10,017.18 | 0.4632 | 4,639.89 | 0.0000 |
| 11 | 4,266.48 | 14,200.00 | 9,933.52 | 0.4289 | 4,260.32 | 0.0000 |
| 12 | 4,351.81 | 14,200.00 | 9,848.19 | 0.3971 | 3,910.85 | 0.0000 |
| 13 | 4,438.85 | 14,200.00 | 9,761.15 | 0.3677 | 3,589.16 | 0.0000 |
| 14 | 4,527.62 | 14,200.00 | 9,672.38 | 0.3405 | 3,293.07 | 0.0000 |
| 15 | 4,618.18 | 14,200.00 | 9,581.82 | 0.3152 | 3,020.59 | 0.0000 |
| 16 | 4,710.54 | 14,200.00 | 9,489.46 | 0.2919 | 2,769.88 | 0.0000 |
| 17 | 4,804.75 | 14,200.00 | 9,395.25 | 0.2703 | 2,539.24 | 0.0000 |
| 18 | 4,900.84 | 14,200.00 | 9,299.16 | 0.2502 | 2,327.10 | 0.0000 |
| 19 | 4,998.86 | 14,200.00 | 9,201.14 | 0.2317 | 2,132.01 | 0.0000 |
| 20 | 5,098.84 | 14,200.00 | 9,101.16 | 0.2145 | 1,952.64 | 0.0000 |
| 21 | 5,200.82 | 14,200.00 | 8,999.18 | 0.1987 | 1,787.74 | 0.0000 |
| 22 | 5,304.83 | 14,200.00 | 8,895.17 | 0.1839 | 1,636.18 | 0.0000 |
| 23 | 5,410.93 | 14,200.00 | 8,789.07 | 0.1703 | 1,496.91 | 0.0000 |
| 24 | 5,519.15 | 14,200.00 | 8,680.85 | 0.1577 | 1,368.96 | 0.0000 |
| 25 | 5,629.53 | 14,200.00 | 8,570.47 | 0.1460 | 1,251.44 | 0.0000 |

## Compliance & Certifications

Equipment placed on the Greek market must satisfy EU conformity requirements. Framework citations below are computed; certificate numbers, issuing Notified Body and OEM manual revision are model-specific and must be requested with the [RFQ](https://tradvolt.com/rfq/).

- CE marking required for EVSE on the EU market — [Directive 2014/35/EU (Low Voltage)](https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32014L0035) and [Directive 2014/30/EU (EMC)](https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32014L0030). Certificate number / Notified Body: PENDING — lookup per model.

- IEC 61851-1:2017 — Electric vehicle conductive charging system — Part 1: General requirements (TC 69) — [IEC publication 33644](https://webstore.iec.ch/en/publication/33644). Test report number: PENDING — lookup per model.

- IEC 61851-23:2014 — Electric vehicle conductive charging system — Part 23: DC electric vehicle charging station — cite the full designation IEC 61851-23:2014 in procurement documents (catalogue lookup at [IEC Webstore](https://webstore.iec.ch/)). Test report number: PENDING — lookup per model.

- IEC 62196-2:2022 ed3 — EV plugs, socket-outlets, vehicle connectors and vehicle inlets — Part 2: Dimensional compatibility for AC pin and contact-tube accessories, up to 480 V AC / 63 A 3-phase (TC 23/SC 23H) — [IEC publication 64364](https://webstore.iec.ch/en/publication/64364). Certificate: PENDING — lookup per model.

- OCPP back-office connectivity — [Open Charge Alliance](https://www.openchargealliance.org/). Version and certification: PENDING — lookup per CPO platform.

- UN 38.3 (lithium battery subassemblies) — UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7 — [UNECE Manual of Tests and Criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria). Test summary: PENDING — lookup per battery subassembly. See also [IEC 62619:2022 ed2](https://webstore.iec.ch/en/publication/62619) for stationary lithium cell safety and [IEC 62485-5:2020](https://webstore.iec.ch/en/publication/29086) for safe operation of stationary lithium-ion batteries.

TradVolt does not represent any specific Notified Body. Certificate numbers, issuing body and OEM manual revision must be confirmed against the OEM's Declaration of Conformity for the exact unit purchased.

## Duty / HS Block — Greece (EU)

```
HS national line | Program | As-of: 2026-09-22 | SoT: official EU TARIC (Greece)
```

| Element | Rate | Source of Truth (official portal) | HS reference |
| --- | --- | --- | --- |
| Import duty (EU Common External Tariff) | PENDING — lookup | EU TARIC consultation (Greece) | HS subheading 8537 (boards/panels for electric control; verify exact national line in TARIC for EVSE) |
| VAT (Greece) | PENDING — lookup | VAT — Taxation and Customs | n/a |
| Excise / other levies | PENDING — lookup | EU TARIC consultation (Greece) | Per TARIC measures |
| Anti-dumping / safeguard measures | PENDING — lookup | EU TARIC consultation (Greece) | Verify per TARIC |

All rates above are PENDING — lookup. TradVolt does not hardcode duty or VAT rates. Confirm at the official EU TARIC portal for Greece at the time of import and via the appointed customs broker.

## Request Quote — Replies in 48 h

Submit the form below to receive a model-specific landed-cost pack, including HS-validated duty stack and freight options to Greece.

[Submit an RFQ via /rfq/](https://tradvolt.com/rfq/)

## Frequently Asked Questions

### 1. What HS code applies to a 60 kW DC EV charger imported from China to Greece?

Charging stations for electric vehicles commonly classify under HS subheading 8537 (boards, panels, consoles for electric control). The exact Greek national TARIC line must be confirmed at the official [EU TARIC portal](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) on the date of import.

### 2. Does a 60 kW DC charger require CE marking for the Greek market?

Equipment placed on the EU/Greek market must carry CE marking where applicable. The applicable directives for a representative OEM family (Growatt THOR 60DS) include [LVD 2014/35/EU](https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32014L0035), [EMC 2014/30/EU](https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32014L0030) and the IEC 61851 series (Part 1: [IEC 61851-1:2017](https://webstore.iec.ch/en/publication/33644)). Confirm with the OEM's Declaration of Conformity and the OEM manual revision for the exact unit.

### 3. How long is the indicative payback for an urban DC 60 kW site in Greece?

Under the stated inputs the computed simple payback is **4.25 years** and the discounted payback is **5.43 years**, with NPV EUR 62,222.70 and IRR 22.93 % (see the computed tables above). Final landed cost requires the [RFQ](https://tradvolt.com/rfq/) and a local electricity tariff lookup.

### 4. What documents are required to import EVSE from China to Greece?

Commercial invoice, packing list, bill of lading ([FIATA](https://fiata.org/) documents), certificate of origin, CE/EMC/LVD Declarations of Conformity, UN 38.3 test summary per the [UN Manual of Tests and Criteria (Rev.7)](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria) for any lithium battery subassembly, and any model test reports. ISPM 15 compliance is required for any wood packaging ([IPPC ISPMs](https://www.ippc.int/en/core-activities/standards-setting/ispms/)). Specific requirements must be confirmed with the Greek customs authority and the appointed customs broker.

### 5. Can TradVolt act as EU responsible person for CE compliance?

Compliance representation is model-specific and must be agreed per order. Indicate the target certification in the [RFQ form](https://tradvolt.com/rfq/) and we will respond within 48 hours.

### 6. Which connector standard is typical for urban 60 kW DC sites in the EU?

CCS2 (IEC 62196-2 / IEC 62196-3 family) is the typical DC connector for the EU market. Confirm with the OEM datasheet for the specific model and any national requirements under AFIR / Greek national rules.