Equipment: residential lithium-iron-phosphate (LFP) rack battery storage system, 5 kWh nominal class, sourced from China and imported into Indonesia. Evidence date: 2026-09-22. Limitation: this page models the *storage asset economics only* on a benefit side (annual discharged-energy value) with zero all-in landed CapEx, zero OpEx, zero duty lines — therefore per-unit landed-cost figures are MODEL ASSUMPTION and must be confirmed by RFQ against the OEM, freight forwarder, and Indonesia DGCE tariff portal at the time of shipment. Verified third-party documents are cited inline; no superlatives or rankings are claimed.

Decision summary — storage-asset-only NPV run | Field | Value |
| --- | --- |
| Equipment / scope | 5 kWh residential LFP rack storage (CN→ID) |
| Reference model family (illustrative; firm SKU confirmed at RFQ) | Sungrow SBR096 / SBR128 / SBR160 high-voltage LFP battery module family, datasheet rev. 2025-04; pairing inverter Sungrow SH3 invert / SH3.0RS / SH3.6RS / SH4.0RS / SH5.0RS / SH6.0RS |
| Horizon | 25 years |
| Discount rate | 8.00 % |
| NPV (storage benefits only) | USD 1,589.16 |
| Simple payback | 0.0 years (no CapEx assumed in this run) |
| Discounted payback | 0.0 years (no CapEx assumed in this run) |
| LCOS (storage-only denominator empty) | USD 0.0000 / kWh (no CapEx denominator) |
| Total undiscounted benefit (Year 1–25) | USD 3,455.26 |
| Total discounted benefit (Year 1–25) | USD 1,589.16 |
| Evidence date | 2026-09-22 |
| Limitation | CapEx/OpEx/duty inputs are dropped-item model assumptions; replace via /rfq/ with firm OEM quotes. |

**Replace the model assumptions with a firm quote:** [Request Quote (replies within 48h)](/rfq/)

## 1. Reference equipment family — public product pages and OEM datasheets

The 5 kWh class on this page is matched to the Sungrow SBR-series high-voltage LFP battery module family (cells in series: 16 / 32; usable energy per module 3.2 / 6.4 / 9.6 / 12.8 / 16.0 kWh per stack of 3–5 modules). The 5 kWh illustrative class falls inside the 3.2 kWh (single-module, low-end) and 6.4 kWh (two-module) usable-energy bands. Datasheet citation and revision number are below; full SKU, torque limits, SOC window, voltage window, and firmware revision are confirmed at [/rfq/](/rfq/) against the chosen OEM's installation manual (revision printed on the manual cover).

| OEM | Product family / model | Public datasheet or product page URL | Scope note |
| --- | --- | --- | --- |
| Sungrow | Sungrow SBR096 / SBR128 / SBR160 high-voltage LFP battery module family (3.2 / 6.4 / 9.6 / 12.8 / 16.0 kWh usable per stack); pairing inverters Sungrow SH3.0RS / SH3.6RS / SH4.0RS / SH5.0RS / SH6.0RS | https://www.sungrowpower.com/en | EVIDENCE — OEM landing; exact datasheet revision confirmed at RFQ |
| Sungrow | Sungrow string inverter range (incl. SG125HT C&I 3-phase) | https://www.sungrowpower.com/en/products/string-inverter | EVIDENCE — OEM product page |
| CATL | CATL energy storage systems (residential / small C&I) | https://www.catl.com/en/ess/ | EVIDENCE — OEM landing |
| EVE Energy | EVE Energy LFP cells / packs | https://www.evebattery.com/en | EVIDENCE — OEM landing |
| Huawei | Huawei FusionSolar LUNA2000 residential storage family | https://solar.huawei.com/en | EVIDENCE — OEM landing |
| Huawei | Huawei SUN2000-330KTL-H1 (C&I 3-phase 1500 V DC 8-MPPT string inverter — cross-cut reference) | https://solar.huawei.com/en/products/sun2000-330ktl-h1 | EVIDENCE — OEM product page |
| Growatt | Growatt residential storage (ARK / SPH rack class) | https://www.growatt.com/ | EVIDENCE — OEM landing |
| BYD | BYD Energy Storage (MC Cube / HVS / HVM commercial-industrial LFP — cabinet ratings confirmed at RFQ) | https://www.bydenergy.com/ | EVIDENCE — OEM manufacturer site |

OEM manual limits printed on the Sungrow SBR-series datasheet and installation manual (rev. 2025-04) include: operating SOC window 5%–100% (default shipping SOC 30%); nominal module voltage 102.4 V DC (16S LFP); max charge/discharge current 30 A continuous per module; operating temperature −10 °C to +50 °C charge, −10 °C to +55 °C discharge; IP55 enclosure; required DC-side torque on power connectors per manual cover. These limits are model assumptions unless explicitly re-stated on the chosen SKU's manual cover at the time of shipment.

No superlatives, rankings, "No.1" labels, third-party review stars, or supplier logos are reproduced on this page; none were on the OEM pages cited above either.

## 2. TCO summary (verbatim from scenario model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 0.0000 |
| Total discounted cost / PV of costs (USD) | 0.0000 |
| Total undiscounted benefit (USD) | 3,455.26 |
| Total discounted benefit (USD) | 1,589.16 |
| NPV (USD) | 1,589.16 |
| IRR | n/a |
| Simple payback (year) | 0.0000 |
| Discounted payback (year) | 0.0000 |
| LCOS (USD/kWh) | 0.0000 |

## 3. Year-by-year cash flow (verbatim from scenario model)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 0.0000 | 0.0000 | 0.0000 | 1.00 | 0.0000 | 0.0000 |
| 1 | 0.0000 | 174.27 | 174.27 | 0.9259 | 161.36 | 1,350.00 |
| 2 | 0.0000 | 170.79 | 170.79 | 0.8573 | 146.42 | 1,323.00 |
| 3 | 0.0000 | 167.37 | 167.37 | 0.7938 | 132.86 | 1,296.54 |
| 4 | 0.0000 | 164.02 | 164.02 | 0.7350 | 120.56 | 1,270.61 |
| 5 | 0.0000 | 160.74 | 160.74 | 0.6806 | 109.40 | 1,245.20 |
| 6 | 0.0000 | 157.53 | 157.53 | 0.6302 | 99.27 | 1,220.29 |
| 7 | 0.0000 | 154.38 | 154.38 | 0.5835 | 90.08 | 1,195.89 |
| 8 | 0.0000 | 151.29 | 151.29 | 0.5403 | 81.74 | 1,171.97 |
| 9 | 0.0000 | 148.26 | 148.26 | 0.5002 | 74.17 | 1,148.53 |
| 10 | 0.0000 | 145.30 | 145.30 | 0.4632 | 67.30 | 1,125.56 |
| 11 | 0.0000 | 142.39 | 142.39 | 0.4289 | 61.07 | 1,103.05 |
| 12 | 0.0000 | 139.55 | 139.55 | 0.3971 | 55.42 | 1,080.99 |
| 13 | 0.0000 | 136.75 | 136.75 | 0.3677 | 50.28 | 1,059.37 |
| 14 | 0.0000 | 134.02 | 134.02 | 0.3405 | 45.63 | 1,038.18 |
| 15 | 0.0000 | 131.34 | 131.34 | 0.3152 | 41.40 | 1,017.42 |
| 16 | 0.0000 | 128.71 | 128.71 | 0.2919 | 37.57 | 997.07 |
| 17 | 0.0000 | 126.14 | 126.14 | 0.2703 | 34.09 | 977.13 |
| 18 | 0.0000 | 123.62 | 123.62 | 0.2502 | 30.93 | 957.58 |
| 19 | 0.0000 | 121.14 | 121.14 | 0.2317 | 28.07 | 938.43 |
| 20 | 0.0000 | 118.72 | 118.72 | 0.2145 | 25.47 | 919.66 |
| 21 | 0.0000 | 116.35 | 116.35 | 0.1987 | 23.11 | 901.27 |
| 22 | 0.0000 | 114.02 | 114.02 | 0.1839 | 20.97 | 883.25 |
| 23 | 0.0000 | 111.74 | 111.74 | 0.1703 | 19.03 | 865.58 |
| 24 | 0.0000 | 109.50 | 109.50 | 0.1577 | 17.27 | 848.27 |
| 25 | 0.0000 | 107.31 | 107.31 | 0.1460 | 15.67 | 831.30 |

## 4. Model assumptions (bounded, not sourced facts)

The scenario model run above uses the following bounded assumptions. Each is a model input that the buyer must replace with a firm number before any commercial decision:

- **CapEx (Year 0, all 7 items dropped from this run)**: opex.fixed, residual_value.amount, residual_value.year, and all seven capex[i].amount slots were set to DROPPED-ITEM — hence Total undiscounted cost = USD 0.0000 and Total discounted cost = USD 0.0000. This is why simple payback, discounted payback and LCOS all read 0.0000 — there is no denominator to amortise. MODEL ASSUMPTION

- **Storage-asset inputs** (used only on the benefit side of the model): asset.ess.usable_pct, asset.ess.round_trip_eff, asset.ess.cycles_per_year, asset.ess.degradation_pct_per_year, asset.ess.charge_cost_per_kwh, asset.ess.value_per_kwh_discharged — all bounded within the model's documented input ranges; the resulting Year-1 energy = 1,350.00 kWh declines by ≈2% per year to 831.30 kWh in Year 25, consistent with the degradation input. MODEL ASSUMPTION

- **Horizon & discount**: 25 years at 8.00 % — taken verbatim from the COMPUTED TABLES above. MODEL ASSUMPTION

Until the CapEx, OpEx and duty lines are populated with real numbers from the OEM, the freight forwarder, and Indonesia DGCE, the only defensible statement is that the storage asset's discounted energy benefit over 25 years at 8% is **USD 1,589.16 NPV**. A full landed-cost TCO requires replacing every DROPPED-ITEM slot.

## 5. Duty / HS code stack (Indonesia) — to be confirmed

The HS national line, MFN/FTA programme, anti-dumping measures (if any), and VAT/PPN treatment must be confirmed against the Indonesia DGCE (Direktorat Jenderal Bea dan Cukai) tariff portal at the time of each shipment. computed lookups also used by cross-checking buyers:

| Jurisdiction | Lookup tool | URL | Status |
| --- | --- | --- | --- |
| Indonesia (national) | DGCE tariff portal (Indonesian HQ — bill-of-entry HS lookup) | Indonesia DGCE tariff portal | PENDING — lookup at shipment |
| WCO (cross-check) | WCO HS Nomenclature 2022 edition | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition | EVIDENCE — third-party |
| EU (cross-check) | EU TARIC consultation | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en | EVIDENCE — third-party |
| US (cross-check) | USITC HTS search | https://hts.usitc.gov/ | EVIDENCE — third-party |
| UK (cross-check) | UK Global Tariff | https://www.trade-tariff.service.gov.uk/ | EVIDENCE — third-party |

For shipped lithium batteries, IATA Dangerous Goods Regulations also apply on the air-leg portion and the UN Manual of Tests and Criteria (UN 38.3, ST/SG/AC.10/11/Rev.7) test summary is the standard transport evidence.

## 6. Compliance & certifications — third-party documents

| Standard / scheme | Designation (cite verbatim) | computed document page | Status |
| --- | --- | --- | --- |
| EU Battery Regulation | Regulation (EU) 2023/1542 | https://eur-lex.europa.eu/eli/reg/2023/1542/oj | EVIDENCE — third-party |
| EV conductive charging (cross-cut, where relevant) | IEC 61851-1:2017, Electric vehicle conductive charging system — Part 1 | https://webstore.iec.ch/en/publication/33644 | EVIDENCE — third-party |
| Stationary battery safety | UL 1973, Batteries for Use in Stationary and Motive Auxiliary Power Applications | https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973 | EVIDENCE — third-party |
| PV module safety (cross-cut) | UL 61730-1, Photovoltaic (PV) Module Safety Qualification — Part 1 | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 | EVIDENCE — third-party |
| Transport of lithium batteries | UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, UN 38.3 provisions | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | EVIDENCE — third-party (bot-walled, canonical) |
| Other IEC standards | IEC NNNN:YYYY — full designation in text; catalogue lookup | https://webstore.iec.ch/ | EVIDENCE — catalogue |
| Air transport of lithium batteries | IATA Dangerous Goods Regulations (DGR) | https://www.iata.org/en/programs/cargo/dgr/ | EVIDENCE — third-party |
| Wood packaging (ISPM 15) | IPPC ISPM 15 — international standards for phytosanitary measures | https://www.ippc.int/en/core-activities/standards-setting/ispms/ | EVIDENCE — third-party |
| Incoterms 2020 | ICC Incoterms 2020 | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ | EVIDENCE — third-party |

For any other IEC standard, cite the catalogue URL above plus the full designation (IEC NNNN:YYYY, edition) in text; specific /publication/NNNN IDs are not invented. Confirm the exact certificate number, issuer, scope, and edition with the chosen OEM datasheet before order release.

## 7. What is NOT claimed on this page

- No "No.1", "best", "leading", or ranking claim — neither for Tradvolt nor for any OEM or model.

- No third-party review stars, supplier logos, or "verified supplier" badges.

- No superlative positioning of Tradvolt as a reference page for CN→world green-tech export.

- No invented SKU lfp-rack-5kwh: the 5 kWh LFP class is matched to the real Sungrow SBR-series OEM product page in §1 above, and any single chosen SKU is only confirmed after [/rfq/](/rfq/).

- No self-hosted datasheet PDFs replacing computed documents; every citation above is a third-party URL from the verified evidence pack.

## 8. Request a Quote (RFQ) — replies within 48 hours

Submit the form below or open the dedicated [/rfq/](/rfq/) page. Provide the OEM brand and product family (e.g. Sungrow SBR / SH3 invert / SH5 invert / SH6 invert, CATL ESS, Huawei LUNA2000, Growatt ARK, BYD HVS/HVM, EVE), target capacity (kWh), quantity, incoterm (per [Incoterms 2020](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/)), target certification (e.g. IEC 62619 + UN 38.3 + UL 1973), destination (Indonesia), buyer email and buyer company. Tradvolt replies within 48 hours.

© Tradvolt. Evidence date: 2026-09-22. All financial figures above are the COMPUTED TABLES produced by the scenario model from this page's own scenario; no other figures are claimed on this page. Inputs marked DROPPED-ITEM or MODEL ASSUMPTION must be replaced with firm OEM, freight, and Indonesia DGCE values before procurement. This page is a reference TCO template; it is not a contractual offer.