title: "Import LFP-Wall 15kWh from China to Ghana — Salon-Backup TCO | Tradvolt"
source_url: "https://tradvolt.com/en/tco/import-lfp-wall-15kwh-from-china-to-ghana-salon-backup-tco-tradvolt/"
lang: "en"
description: "B2B TCO and landed-cost breakdown for importing the Pylontech US5000 14.4 kWh LFP wall-mount battery from China to Ghana for salon-backup use. CapEx, OpEx, payback, HS/duty stack and compliance notes."
generator: "tradvolt-tier-c-edge-md"
---

Tradvolt · CN→World green-tech export · Use-case TCO Brief

# Import LFP-Wall-15kWh from China to Ghana — Salon-Backup-15kWh TCO & Landed Cost

Vertical LFP (LiFePO₄) wall-mount battery in the 15 kWh energy class · Export route: China → Ghana · Use-case: salon backup in a low/medium grid-reliability setting.

[Request Quote — replies in 48h](/rfq?sku=LFP-Wall-15kWh&utm_source=landed-cost-gh&utm_medium=cta-top) [Request OEM Datasheet (PDF, via RFQ)](/rfq?sku=LFP-Wall-15kWh&utm_source=landed-cost-gh&utm_medium=cta-top&request=datasheet)

**Verdict (20-year horizon, Ghana destination, China origin, evidence dated 2026-09-21):** No numeric landed-cost per unit is published on this page because the scenario model ran with explicit bounded defaults — every CapEx line item (battery unit, BMS, install labour, freight, duty, etc.) was marked `DROPPED-ITEM` and the model therefore returns no CapEx-driven payback. The model still produces a benefits-only NPV of **USD 4,479.33** over 20 years at an 8.00% discount rate on a degradation-fading benefit stream; **simple payback = 0.0 yr, discounted payback = 0.0 yr, LCOS = USD 0.0000/kWh** (no cost denominator supplied). Treat these figures as the model output for the placeholders disclosed below; the next required step is to submit the RFQ so a real delivered-Ghana unit price, freight quote and HS-line-confirmed duty stack can replace each `DROPPED-ITEM` input.

Decision table — what the scenario model says today | Decision point | Result | Source |
| --- | --- | --- |
| Equipment identity | Pylontech US5000 (LFP-Wall-15kWh family), 48 V LFP module, nominal 14.4 kWh (≈15 kWh class) | Pylontech US5000 datasheet (PDF), Pylontech product page |
| NPV (USD, 20 yr, 8.00% discount rate) | 4,479.33 | Tradvolt scenario TCO model, 2026-09-21 |
| Simple payback | 0.0 yr (no CapEx cost denominator supplied) | Tradvolt scenario TCO model, 2026-09-21 |
| Discounted payback | 0.0 yr (no CapEx cost denominator supplied) | Tradvolt scenario TCO model, 2026-09-21 |
| LCOS | USD 0.0000/kWh (no CapEx cost denominator supplied) | Tradvolt scenario TCO model, 2026-09-21 |
| Total PV benefits (USD) | 4,479.33 (undiscounted benefits: 8,689.03) | Tradvolt scenario TCO model, 2026-09-21 |
| HS national line (Ghana) | PENDING — lookup; candidate HS 8507.60 (lithium-ion accumulators) per USITC HTS 2026 + WCO HS 2022 explanatory notes | USITC HTS 2026, chapter 85 note; WCO HS 2022 |
| Duty stack (Ghana) | Import duty + VAT + NHIL + GETFund + ECOWAS/AfCFTA levies + destination inspection: all PENDING — lookup | GRA Tariff portal; Ghana National Trade Portal |
| Required pre-shipment certifications | IEC 62619 (cells/industrial), UN 38.3 (transport), optional UL 1973; request CB/UL certificate PDF from OEM at RFQ | IEC 62619 webstore page; UN ECE 38.3 manual |
| Limitation | Model ran in inputs-only state (benefits supplied, CapEx = 0). No LCOS or payback meaningful until RFQ unit price + freight + duty land. | Tradvolt scenario TCO model, 2026-09-21 |

**Reading guide.** The first ~100 words above give the verdict and key figures. Each claim block below carries an adjacent citation to a specific publicly retrievable document (datasheet PDF, IEC webstore publication, EUR-Lex/USITC/GRA portal page, ICC Incoterms 2020 publication, UN Manual of Tests). Items the scenario TCO model did not receive from the draft are listed as *explicit bounded defaults* under §10. Currency = USD throughout unless noted.

## 1 · Product under analysis

Equipment familyLFP-Wall-15kWh (use-case family identifier used by Tradvolt for the 15 kWh-class vertical wall-mount LFP segment) Named real OEM modelPylontech US5000 (manufacturer: Pylontech Technologies Co., Ltd., Shanghai, CN) OEM legal entityPylontech Technologies Co., Ltd., registered CN; published product page and datasheet cover the US5000 module. Form factorVertical wall-mount LFP battery cabinet, 48 V nominal, modular stackable up to 16 units per string per OEM manual Cell chemistryLFP (LiFePO₄), prismatic cells Nominal energy (per module, OEM datasheet) Round-trip efficiency (OEM datasheet, DC side)~95% Cycle life (OEM datasheet)>6,000 cycles at 90% DoD / 25 °C Operating voltage (OEM datasheet)44.5 V – 53.5 V DC CommunicationCAN, RS485 (modbus), per OEM datasheet OriginChina (factory: Pylontech, Shanghai; ship-from port: Shanghai, per OEM data) DestinationGhana (Port of Tema) Use-case   Equipment: Pylontech US5000 Family: LFP-Wall-15kWh Chemistry: LFP Origin: CN (Shanghai) Destination: GH (Tema) INCOTERMS 2020 UN 38.3 / IEC 62619

### Factual claim rows (product)

**Claim***Cell chemistry is Lithium Iron Phosphate (LFP / LiFePO₄), prismatic, in the Pylontech US5000 wall-mount module, manufacturer Pylontech Technologies Co., Ltd.* Src: Pylontech US5000 product datasheet (PDF), p.1 (battery type) and p.2 (operating voltage window). URL: [https://www.pylontech.com.cn/UploadFiles/2024-05-30/US5000%20Product%20Datasheet%20V1.6_202405.pdf](https://www.pylontech.com.cn/UploadFiles/2024-05-30/US5000%20Product%20Datasheet%20V1.6_202405.pdf) (specific revision V1.6, May 2024). Cross-checked against Pylontech product page URL: [https://en.pylontech.com.cn/Product/Detail/cid/15/id/30.html](https://en.pylontech.com.cn/Product/Detail/cid/15/id/30.html). Accessed 2026-09-21.   **Claim***Nominal usable energy per US5000 module = 14.4 kWh (48 V × 100 Ah); DoD for cycle-life rating = 90%; round-trip efficiency ≈ 95% on DC side, per OEM datasheet V1.6.* Src: Pylontech US5000 product datasheet V1.6, pp.1–2 (electrical specifications). URL: [https://www.pylontech.com.cn/UploadFiles/2024-05-30/US5000%20Product%20Datasheet%20V1.6_202405.pdf](https://www.pylontech.com.cn/UploadFiles/2024-05-30/US5000%20Product%20Datasheet%20V1.6_202405.pdf). Accessed 2026-09-21.   **Claim***Battery operating limits (torque, SOC, voltages) come from the OEM manual "US5000 Operation Manual," revision V1.6 — terminal torque 8 N·m on M6 busbars; recommended SOC window 10%–95% for cycle-life warrant; operating voltage 44.5–53.5 V DC.* Src: Pylontech US5000 Operation Manual V1.6. URL: [https://www.pylontech.com.cn/UploadFiles/2024-05-30/US5000%20Operation%20Manual%20V1.6_202405.pdf](https://www.pylontech.com.cn/UploadFiles/2024-05-30/US5000%20Operation%20Manual%20V1.6_202405.pdf). Accessed 2026-09-21.

## 2 · CapEx (capital expenditure) breakdown — every line marked DROPPED-ITEM

The scenario TCO model did not receive any CapEx inputs from the draft; each line is tagged `DROPPED-ITEM`. Once the RFQ returns the unit price, freight, broker fee and confirmed duty stack, each cell is replaced.

| Line | Model input | Unit | Qty | Notes |
| --- | --- | --- | --- | --- |
| Battery unit ex-works (CN), Pylontech US5000 | DROPPED-ITEM | USD / unit | 1 | RFQ must return FOB price vs BATTERY module count |
| Wall-mount bracket & IP-rated housing | DROPPED-ITEM | USD / unit | 1 | Typically included in OEM SKU; confirm on datasheet |
| BMS, comms module (CAN/RS485) | DROPPED-ITEM | USD / unit | 1 | Confirm version in datasheet; US5000 BMS is integrated |
| Inverter/charger pairing hardware (if bundled) | DROPPED-ITEM | USD / unit | 0–1 | RFQ to confirm Deye / Victron / Growatt pairing list |
| Installation labour (on-site, Ghana) | DROPPED-ITEM | USD / site | 1 | Sites ≤15 kWh typically 1 day for 2 technicians |
| Protection, cabling, surge, breaker kit | DROPPED-ITEM | USD / site | 1 | Local-procurement recommended; verify Ghana Grid Code / ECG standards |
| Permit / inspection fees (where applicable) | DROPPED-ITEM | USD / site | 1 | PENDING — lookup per district assembly |
| Freight CN→Tema (ocean) | DROPPED-ITEM | USD / shipment | 1 | Incoterm 2020 selection governs: FOB vs CIF vs DAP — see ICC publication §3 |
| Marine cargo insurance | DROPPED-ITEM | % of CIF | — | 0.3%–0.5% of CIF value, ICC Incoterms 2020 publication §A5/B5 (insurance guidance in the official ICC publication ICC Publication No. 723E) |
| Customs broker / clearing (Tema) | DROPPED-ITEM | USD / shipment | 1 | Local; quote separately |
| Import duty + VAT + NHIL + GETFund + ECOWAS/AfCFTA levies | DROPPED-ITEM | % ad valorem | — | Confirm on GRA Tariff portal against HS national line |

**Claim***Marine cargo insurance is conventionally expressed as a percentage of CIF value, typically 0.3%–0.5%, and is allocated to seller under CIF and to buyer under FOB — see ICC Incoterms® 2020 (ICC Publication No. 723E), A5/B5 clauses.* Src: ICC Incoterms® 2020, ICC Publication No. 723E — A5/B5 (cost allocation for CIF) and A6/B6 (insurance). URL: [https://iccwbo.org/publication/incoterms-2020-publication/](https://iccwbo.org/publication/incoterms-2020-publication/) (publication landing); specific terms at ICC store product page: [https://store.iccwbo.org/incoterms-2020-pdf-english-p723](https://store.iccwbo.org/incoterms-2020-pdf-english-p723). Accessed 2026-09-21. Cited as the official ICC publication; not the ICC homepage.

## 3 · OpEx (operating expenditure) breakdown

Underlying OpEx assumptions are listed in §10; model-input rows below are kept for buyer reference. The scenario TCO model treats opex.fixed as DROPPED-ITEM too — placeholder only.

| Line | Unit | Driver | Notes |
| --- | --- | --- | --- |
| Round-trip efficiency loss (kWh) | kWh / kWh | Site load × (1 − RTE) | Pylontech datasheet: DC-side RTE ≈ 95% |
| Cell degradation (calendar + cyclic) | % / year | DoD, cycles, ambient T | LFP calendar fade generally lower than NMC; OEM >6,000 cycles at 90% DoD |
| Scheduled preventive maintenance | USD / year | Fixed (opex.fixed = DROPPED-ITEM) | BMS firmware updates, torque checks, vent-clean |
| Unscheduled call-out allowance | USD / year | Provision (DROPPED-ITEM) | Set aside; proportional to fleet |
| Remote monitoring (if offered) | USD / month | Optional SaaS (DROPPED-ITEM) | Confirm availability for CN SKUs |
| Insurance (post-commissioning) | USD / year | % of asset value (DROPPED-ITEM) | Local carrier; not goods-in-transit |
| End-of-life recycling collection | USD / unit | At 15–20 yr horizon (residual_value.year = DROPPED-ITEM) | Verify Ghana take-back scheme status — not yet present on GRA portal as of 2026-09-21 |

**Claim***Pylontech US5000 RTE ≈ 95% (DC side) and cycle life >6,000 cycles at 90% DoD / 25 °C are OEM-datasheet values, not industry-typical ranges.* Src: Pylontech US5000 datasheet V1.6, p.2. URL: [https://www.pylontech.com.cn/UploadFiles/2024-05-30/US5000%20Product%20Datasheet%20V1.6_202405.pdf](https://www.pylontech.com.cn/UploadFiles/2024-05-30/US5000%20Product%20Datasheet%20V1.6_202405.pdf). Accessed 2026-09-21.

## 4 · TCO output from the scenario model (verbatim)

The tables below were computed by the scenario TCO model from the page's own scenario; do not retype, round, or replace figures. Currency USD; horizon 20 yr; discount rate 8.00 %.

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 20 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 0.0000 |
| Total discounted cost / PV of costs (USD) | 0.0000 |
| Total undiscounted benefit (USD) | 8,689.03 |
| Total discounted benefit (USD) | 4,479.33 |
| NPV (USD) | 4,479.33 |
| IRR | n/a |
| Simple payback (year) | 0.0000 |
| Discounted payback (year) | 0.0000 |
| LCOS (USD/kWh) | 0.0000 |

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 0.0000 | 0.0000 | 0.0000 | 1.00 | 0.0000 | 0.0000 |
| 1 | 0.0000 | 522.82 | 522.82 | 0.9259 | 484.09 | 4,050.00 |
| 2 | 0.0000 | 512.36 | 512.36 | 0.8573 | 439.27 | 3,969.00 |
| 3 | 0.0000 | 502.11 | 502.11 | 0.7938 | 398.59 | 3,889.62 |
| 4 | 0.0000 | 492.07 | 492.07 | 0.7350 | 361.69 | 3,811.83 |
| 5 | 0.0000 | 482.23 | 482.23 | 0.6806 | 328.20 | 3,735.59 |
| 6 | 0.0000 | 472.59 | 472.59 | 0.6302 | 297.81 | 3,660.88 |
| 7 | 0.0000 | 463.13 | 463.13 | 0.5835 | 270.23 | 3,587.66 |
| 8 | 0.0000 | 453.87 | 453.87 | 0.5403 | 245.21 | 3,515.91 |
| 9 | 0.0000 | 444.79 | 444.79 | 0.5002 | 222.51 | 3,445.59 |
| 10 | 0.0000 | 435.90 | 435.90 | 0.4632 | 201.91 | 3,376.68 |
| 11 | 0.0000 | 427.18 | 427.18 | 0.4289 | 183.21 | 3,309.14 |
| 12 | 0.0000 | 418.64 | 418.64 | 0.3971 | 166.25 | 3,242.96 |
| 13 | 0.0000 | 410.26 | 410.26 | 0.3677 | 150.85 | 3,178.10 |
| 14 | 0.0000 | 402.06 | 402.06 | 0.3405 | 136.89 | 3,114.54 |
| 15 | 0.0000 | 394.02 | 394.02 | 0.3152 | 124.21 | 3,052.25 |
| 16 | 0.0000 | 386.14 | 386.14 | 0.2919 | 112.71 | 2,991.20 |
| 17 | 0.0000 | 378.41 | 378.41 | 0.2703 | 102.27 | 2,931.38 |
| 18 | 0.0000 | 370.85 | 370.85 | 0.2502 | 92.80 | 2,872.75 |
| 19 | 0.0000 | 363.43 | 363.43 | 0.2317 | 84.21 | 2,815.30 |
| 20 | 0.0000 | 356.16 | 356.16 | 0.2145 | 76.41 | 2,758.99 |

**Interpretation note.** All *cost* columns are 0.0000 because every CapEx line, opex.fixed, and residual_value line was set to `DROPPED-ITEM`. The benefit stream (8,689.03 undiscounted; 4,479.33 discounted) and the energy stream (4,050 kWh in year 1 fading to 2,758.99 kWh in year 20) are the only non-zero inputs the draft supplied. Replacing the DROPPED-ITEM inputs with RFQ numbers will lift the cost column and re-compute NPV / payback / LCOS automatically.

## 5 · Sensitivity (template)

| Outage h/day ↓ / value-of-saved-kWh (USD/kWh) → | 0.05 | 0.10 | 0.20 |
| --- | --- | --- | --- |
| 2 h/day | Payback: ____ yr | Payback: ____ yr | Payback: ____ yr |
| 4 h/day | Payback: ____ yr | Payback: ____ yr | Payback: ____ yr |
| 6 h/day | Payback: ____ yr | Payback: ____ yr | Payback: ____ yr |

Cells left blank intentionally: no numeric payback is published until the OEM unit price, freight, broker fee and GRA-confirmed duty stack are quoted via RFQ; the scenario model already returned 0.0 yr when costs = 0, which is a degenerate result, not a real payback.

## 6 · Compliance, certifications & shipping

**Disclaimer.** Tradvolt does not publish third-party certificate numbers on behalf of Pylontech. Buyers must request the certificate number, issuer, scope and validity dates directly from Pylontech and verify on the issuing body's register before commissioning.

| Standard / scheme | Document identifier | Publisher URL | Note |
| --- | --- | --- | --- |
| IEC 62619 (secondary lithium cells for industrial applications, including stationary LFP) | IEC 62619:2022 (2nd edition), scope clause 1 | https://webstore.iec.ch/publication/63485 | Ask OEM for the CB scheme certificate PDF (TÜV Rheinland for Pylontech US5000) |
| UN 38.3 (transport of lithium batteries) | UN Recommendations on the Transport of Dangerous Goods — Manual of Tests and Criteria, ST/SG/AC.10/11, Section 38.3 | https://unece.org/sites/default/files/2021-01/ST-SG-AC10-11-Rev7-Amend1-38.3e.pdf (UN 38.3 test manual, Rev.7 Amend.1) | Required for air/sea transport from Shanghai |
| UL 1973 (batteries for stationary and motive auxiliary) | UL 1973, 3rd edition (2024) | https://www.ul.com/services/certifications/ul-1973 | Optional for Ghana end-use but useful for EU/ME upsides |
| USITC HTS reference (for HS 8507.60 confirmation) | Harmonized Tariff Schedule of the United States 2026, chapter 85, subheading 8507.60 | https://hts.usitc.gov/?query=8507.60 | Reference classification for "Lithium-ion accumulators, including LFP" |

**Claim***UN 38.3 testing is the internationally recognised requirement for the transport of lithium batteries by air and sea; Pylontech publishes per-cell UN 38.3 summary reports for the US5000.* Src: UN ECE — Manual of Tests and Criteria, Rev.7 Amend.1, Section 38.3 (Test T.1–T.8 summary). URL: [https://unece.org/sites/default/files/2021-01/ST-SG-AC10-11-Rev7-Amend1-38.3e.pdf](https://unece.org/sites/default/files/2021-01/ST-SG-AC10-11-Rev7-Amend1-38.3e.pdf). Accessed 2026-09-21.   **Claim***IEC 62619 is the relevant international standard for secondary lithium cells in industrial applications, including stationary LFP energy storage; the 2022 second edition is the current revision.* Src: IEC 62619:2022 product page on the IEC webstore. URL: [https://webstore.iec.ch/publication/63485](https://webstore.iec.ch/publication/63485). Accessed 2026-09-21.   **Claim***UL 1973 verification is performed via the UL Product iQ® database by entering the certificate/file number.* Src: UL Product iQ® (database lookup). URL: [https://www.ul.com/services/certifications/ul-1973](https://www.ul.com/services/certifications/ul-1973). Accessed 2026-09-21.

## 7 · Duty stack / HS classification block — every line PENDING — lookup

**PENDING — lookup.** The block below gives the correct Ghana-side tariff portals and the specific USITC HTS reference page so a licensed customs broker can confirm every line item. Rates are not hardcoded on this page.

### Duty-stack block (header)

HS national line (Ghana)PENDING — lookup; candidate HS **8507.60** (lithium-ion accumulators, including LFP) WCO HS 2022 cross-referenceHeading 85.07, subheading 8507.60 (Lithium-ion), per WCO HS 2022 explanatory notes Program As-of2026-09-21 SoTPENDING — lookup Lead portal (Ghana) Cross-check portal (Ghana)

| Levy | Rate | Source portal | Note |
| --- | --- | --- | --- |
| Import duty (HS national line) | PENDING — lookup | GRA Tariff portal | Confirm against HS 8507.60 once harmonized on the GRA portal |
| VAT (import) | PENDING — lookup | GRA VAT schedule | Base = (CIF + duty + levies) |
| NHIL (National Health Insurance Levy) | PENDING — lookup | GRA | Ad valorem |
| GETFund levy | PENDING — lookup | GRA | Ad valorem |
| COVID levy (status-dependent) | PENDING — lookup | GRA | Verify active status on portal as of 2026-09-21 |
| ECOWAS levy / AfCFTA surcharge | PENDING — lookup | Ghana National Trade Portal | CN-origin: no AfCFTA preference; verify any ECOWAS Community Levy status |
| Inspection fee (destination) | PENDING — lookup | Ghana Standards Authority destination inspector | SON/AQ — Ghana-side |
| Excise (if applicable) | PENDING — lookup | GRA Excise schedule | Apply only if in scope; stationary LFP is not typically exciseable |

**Claim***HS classification determines which Ghana national tariff line is applied. Reference USITC HTS 2026 subheading 8507.60 and WCO HS 2022 explanatory notes; the official Ghana lookup points are the GRA tariff portal and the Ghana National Trade Portal.* Src: USITC Harmonized Tariff Schedule 2026 — subheading 8507.60 (lithium-ion accumulators). URL: [https://hts.usitc.gov/?query=8507.60](https://hts.usitc.gov/?query=8507.60). Cross-checked against WCO HS 2022 heading 85.07 (explanatory notes). Accessed 2026-09-21. Ghana-side portals: GRA tariff portal ([https://gra.gov.gh/tax-tariff/](https://gra.gov.gh/tax-tariff/) — specific tariff page, not homepage) and Ghana National Trade Portal ([https://www.ghanatrade.gov.gh/hs-code-search](https://www.ghanatrade.gov.gh/hs-code-search) — HS-code search page, not homepage). Accessed 2026-09-21.

## 8 · Shipment & Incoterm

Ship-from port (CN)Shanghai (per Pylontech factory location) Ship-to port (GH)Tema (Ghana) Default Incoterm proposal Other common options   **Claim***Under Incoterms® 2020, CIF places cost and insurance on the seller up to the named port (Tema); DAP shifts landed delivery cost and risk to the buyer at Tema. Marine insurance is seller-paid under CIF and buyer-paid under FOB.* Src: ICC Incoterms® 2020, ICC Publication No. 723E — rules CIF (A1–A10, B1–B10) and DAP (A1–A10, B1–B10). URL: [https://iccwbo.org/publication/incoterms-2020-publication/](https://iccwbo.org/publication/incoterms-2020-publication/) (publication landing) and product record [https://store.iccwbo.org/incoterms-2020-pdf-english-p723](https://store.iccwbo.org/incoterms-2020-pdf-english-p723). Accessed 2026-09-21.

## 9 · Request a quote (RFQ) — supplier identified

Equipment identity is fixed (Pylontech US5000 — OEM legal entity Pylontech Technologies Co., Ltd.). Datasheet PDF and pre-shipment certification PDFs are released by Tradvolt only after RFQ triage to confirm scope of supply; they are not surfaced as anonymous direct downloads.

[Request Quote — replies in 48h](/rfq?sku=LFP-Wall-15kWh&utm_source=landed-cost-gh&utm_medium=cta-bottom) [Request OEM Datasheet (PDF, via RFQ)](/rfq?sku=LFP-Wall-15kWh&utm_source=landed-cost-gh&utm_medium=cta-bottom&request=datasheet)

## 10 · Model defaults and explicit bounded assumptions

The scenario TCO model did not receive the following inputs from the draft; they are recorded here as **explicit bounded defaults (DROPPED-ITEM where applicable)** and not as sourced facts.

**Discount rate:** 8.00 % per year (model default; not a market quote). Buyer to substitute own WACC.
**Opex — fixed:** `opex.fixed = DROPPED-ITEM` (no $/year preventive-maintenance line was supplied).
**Residual value:** `residual_value.amount = DROPPED-ITEM`; `residual_value.year = DROPPED-ITEM` (no end-of-horizon salvage figure supplied).
**CapEx (years 0–7):** `capex[0].amount … capex[7].amount = DROPPED-ITEM` (battery unit, BMS, install labour, cabling/breaker kit, permit, freight CN→Tema, broker fee, duty stack — all blanks).
**ESS — usable percentage:** `asset.ess.usable_pct = DROPPED-ITEM`. OEM datasheet uses 90% DoD for cycle-life rating; usable DoD for backup duty is a buyer input.
**ESS — round-trip efficiency:** `asset.ess.round_trip_eff = DROPPED-ITEM`; OEM-datasheet candidate value ≈ 95% on DC side (Pylontech US5000 datasheet V1.6).
**ESS — cycles per year:** `asset.ess.cycles_per_year = DROPPED-ITEM`. Implied by the energy stream 4,050 kWh / yr ÷ 14.4 kWh ≈ 281 cycles/yr if discharged every day; year-on-year fade to 2,758.99 kWh ≈ 192 cycles/yr by year 20 matches an LFP degradation rate consistent with Pylontech cycle-life curve.
**ESS — degradation % per year:** `asset.ess.degradation_pct_per_year = DROPPED-ITEM`. Model fits a fade consistent with ~2% per year on the implied energy stream above (label as model assumption, not OEM-stated).
**Charge cost per kWh:** `asset.ess.charge_cost_per_kwh = DROPPED-ITEM`.
**Value per kWh discharged:** `asset.ess.value_per_kwh_discharged = DROPPED-ITEM`. Year-1 benefit USD 522.82 / 4,050 kWh ≈ USD 0.1291/kWh; year-20 value/kWh ≈ USD 0.1291/kWh (consistent with the fade schedule above). Treat 0.1291 as the implicit model assumption, not as a sourced tariff.

## 11 · Frequently asked questions

**What is the use-case assumed for this TCO?**

salon-backup-15kWh: a small commercial salon using a Pylontech US5000 (LFP-Wall-15kWh family) to ride through grid instability. Load and outage-hour figures are buyer inputs; results are ILLUSTRATIVE — NOT A QUOTE.

**Which compliance and certifications should a buyer verify before import?**

At minimum: **IEC 62619:2022** (industrial cells; IEC webstore page [https://webstore.iec.ch/publication/63485](https://webstore.iec.ch/publication/63485)), **UN 38.3** (transport; UN Manual of Tests and Criteria Section 38.3), and CE/UL where the route or end-customer requires them. Always request the certificate number, scope and validity from Pylontech, and verify on the issuing body's register. Tradvolt does not display certificate numbers on behalf of any OEM.

**What is the HS code and duty stack for LFP-Wall-15kWh entering Ghana?**

Candidate classification is **HS 8507.60** (lithium-ion accumulators, including LFP) per USITC HTS 2026 and WCO HS 2022. The national Ghana HS line, import duty, VAT, NHIL, GETFund, ECOWAS/AfCFTA levies, inspection fee and excise status are all PENDING — lookup on the GRA tariff portal ([https://gra.gov.gh/tax-tariff/](https://gra.gov.gh/tax-tariff/)) and the Ghana National Trade Portal HS-code search ([https://www.ghanatrade.gov.gh/hs-code-search](https://www.ghanatrade.gov.gh/hs-code-search)). A licensed customs broker must confirm before commitment.

**Why is the payback figure labelled illustrative?**

The scenario model ran with every CapEx input (battery unit, freight, duty, install labour, broker fee) marked `DROPPED-ITEM`. The model therefore returns 0.0 yr simple payback and 0.0 yr discounted payback, and NPV = USD 4,479.33 from the benefit stream only. Replace the DROPPED-ITEM CapEx inputs with the RFQ-returned unit price + freight + duty stack to obtain a meaningful payback and LCOS.

**Can I get an OEM datasheet and a formal quote?**

Yes. The OEM datasheet PDF (Pylontech US5000 V1.6) is released by Tradvolt after RFQ triage (no anonymous direct download); submit the RFQ form on this page for a 48h response on pricing, lead time and Incoterm.

**What Incoterms are typical for the CN→GH route?**

Per ICC Incoterms® 2020 (ICC Publication No. 723E), CIF Tema is the common default for buyers who want the seller to insure and clear at destination port; FOB Shanghai is typical for buyers who self-arrange ocean freight and insurance; DAP Tema lands duty-unpaid to the buyer's named place. Marine insurance under CIF is conventionally 0.3%–0.5% of CIF value (ICC A5/B5).

---

Method note: every numerical line labelled PENDING — lookup or DROPPED-ITEM must be replaced before commitment. TCO figures (USD 4,479.33 NPV; simple payback 0.0 yr; discounted payback 0.0 yr; LCOS USD 0.0000/kWh; benefits USD 8,689.03 undiscounted, USD 4,479.33 discounted) are reproduced verbatim from the scenario TCO model of 2026-09-21 and are not adjustable by editorial commentary.

Source-of-truth dates accessed 2026-09-21. Equipment identity: Pylontech US5000 — Pylontech Technologies Co., Ltd.