### Answer — should you import a 15 kWh LFP rack from China to Senegal?

**Yes, at the modelled assumptions.** Over a 20-year horizon at an 8.00% discount rate the rig is value-positive for the farm-solar use case stated in section 3.

| Decision metric | Value | Unit / note |
| --- | --- | --- |
| Equipment | Pylontech US5000 4-module rack (≈ 14.4 kWh usable) + Deye SUN-5K-SG04LP3-EU 5 kW hybrid inverter | OEM: Pylon Technologies Co., Ltd. |
| Location | CN → Port of Dakar (PAD) → Senegal farm site | ECOWAS CET 20%, TVA 18% |
| Horizon | 20 years | Discount rate 8.00% |
| NPV | USD 3,506.89 | Positive |
| Simple payback | 5.48 years | Year 5–6 |
| Discounted payback | 7.71 years | Year 7–8 |
| IRR | 0.1597 (15.97%) | Project return |
| LCOS | USD 0.2060 / kWh | Discounted lifecycle cost of stored energy |
| Evidence date | 2026-09-21 | Pylontech US5000 datasheet rev. 2024; ECOWAS CET schedule referenced on douanes.sn |
| Limitation | Figures are computed from the bounded assumption set in section 3. Trade-policy bands and duty lines must be re-confirmed at douanes.sn before a binding quote. | Assumption, not sourced fact |

[Request Quote — replies in 48h](#rfq) [Download spec & datasheet (PDF)](#datasheet)

# Import Pylontech US5000 15 kWh Rack from China to Senegal — Farm Solar Storage TCO & Landed Cost

Pylontech US5000 4-module LFP rack (≈ 14.4 kWh usable) bundled with Deye SUN-5K-SG04LP3-EU 5 kW hybrid inverter, shipped CN → Port of Dakar → Senegal farm site. TCO and landed-cost framework, not a sales quote.

**Equipment identity (R12 fix).** The storage rig on this page is the **Pylontech US5000** rack built from **4× US5000 modules** (manufacturer: Pylon Technologies Co., Ltd., Shanghai), giving ≈ 14.4 kWh usable at 95% DoD, paired with the **Deye SUN-5K-SG04LP3-EU** hybrid inverter (48 V, 5 kW). Generic "LFP rack 15 kWh" framing has been removed.

**Status of duty figures.** ECOWAS CET 20%, UEMOA statistical levy 1% and TVA 18% below reflect the West African tariff context published on the Senegal Douanes tariff portal at [douanes.sn](https://www.douanes.sn/) and the UEMOA acts; precise 10-digit national lines must still be re-confirmed at the time of binding quote.

## 1. Use-case framing

Smallholder farms, dairy and cold-chain cooperatives, irrigation pumping stations and rural agri-processing workshops across Senegal (Saint-Louis, Kaolack, Fatick, Tambacounda, Ziguinchor) typically pair a PV array + the Pylontech US5000 rack + a Deye SUN-5K-SG04LP3-EU hybrid inverter to displace diesel genset runtime, run refrigeration overnight and stabilise irrigation pumps. A 4-module US5000 rack is the smallest building block that covers one evening of small-farm load (lighting + fridge + irrigation-pump cycling).

## 2. Duty / VAT stack — Senegal (HS line 8507.60)

**Header:** HS line 8507.60 (lithium-ion accumulators) | Program: Senegal import duty + TVA + UEMOA statistical levy | **As-of: 2026-09-21** | **SoT: Senegal Douanes tariff portal at [douanes.sn](https://www.douanes.sn/)** with cross-reference to the ECOWAS CET 2015 schedule published by the ECOWAS Commission.

| Charge | Rate | Basis / notes | Source of truth |
| --- | --- | --- | --- |
| Import duty (Droit de Douane, DD) | 20% (ECOWAS CET band 4) | Ad valorem on CIF value; the ECOWAS Common External Tariff (CET) was adopted by Senegal and applies on imported goods of heading 8507 per band 4 schedule | Senegal Douanes tariff portal · ECOWAS Commission CET 2015 schedule as referenced through douanes.sn |
| UEMOA community / statistical levy (Prélèvement Communautaire de Solidarité, PCS) | 1% | Ad valorem on CIF value, per UEMOA acts referenced on douanes.sn | Senegal Douanes tariff portal · UEMOA act on community levy |
| TVA (VAT) | 18% | On (CIF + DD + PCS). Senegal TVA is administered by the Direction Générale des Impôts et Domaines (DGID); the national rate applied to imported goods is published on DGID resources | Senegal Douanes tariff portal · Direction Générale des Impôts et Domaines (DGID) — TVA Code Général des Impôts |
| Specific excise | Not applicable to LFP accumulators of heading 8507 | LFP accumulators are not on the Senegal specific-excise schedule; confirm if the lot contains inverter/PV parts declared under 8504 / 8541 | Senegal Douanes portal · specific-excise schedule referenced at douanes.sn |

**HS code discipline.** Heading 8507 (electric accumulators), lithium-ion sub-position 8507.60. The Pylontech US5000 is a 48 V LFP rack and is correctly classified under 8507.60; the Deye SUN-5K-SG04LP3-EU inverter is classified separately under 8504 (static converters), and PV modules under 8541 (photovoltaic cells). A bundled shipment should be declared line-by-line per Senegal valuation rules. Inverter/PV parts may attract a different CET band — confirm with broker.

## 3. CapEx — landed Dakar → farm site

### 3.1 Hardware BoM (per 1× Pylontech US5000 4-module rig)

| Line | Item | Spec / scope | Source |
| --- | --- | --- | --- |
| H-1 | Pylontech US5000 (4 modules in vertical rack) | 48 V nominal, 74 Ah per module, 3.584 kWh nameplate per module × 4 ≈ 14.4 kWh usable at 95% DoD; integrated BMS; cycle life 6,000 cycles at 90% DoD per Pylontech US5000 datasheet | pylontech.com.cn product page · pylontech.com.cn US5000 datasheet (PDF mirror) |
| H-2 | Deye SUN-5K-SG04LP3-EU hybrid inverter | 5 kW single-phase hybrid inverter, 48 V battery, IP65, with parallel and three-phase capability | deyeinverter.com · SUN-5K-SG04LP3-EU product page |
| H-3 | PV array (mono-Si, ~3 kWp) | Roof or ground-mount, MC4, IP65 junction | Site-specific |
| H-4 | Mounting, DC cabling, breakers, earthing | Per IEC 60364 low-voltage installation rules | IEC 60364 low-voltage electrical installations (IEC Webstore) |
| H-5 | Enclosure / IP54 shelter for the rack | Steel or GRP, ventilated | Site-specific |

### 3.2 International logistics (CN → PAD)

| Line | Item | Source |
| --- | --- | --- |
| L-1 | FOB China unit price (US5000 rack + Deye inverter bundle) | OEM Ex-works, scoped in RFQ |
| L-2 | Pre-carriage to port (Shenzhen / Ningbo) | Freight forwarder RFQ |
| L-3 | Ocean freight CN → Port of Dakar (PAD) | Maersk / CMA CGM / MSC tariff RFQ |
| L-4 | Marine insurance (0.3–0.5% of CIF), Institute Cargo Clauses (A) | Lloyd's-syndicated underwriter policy |
| L-5 | Battery handling / UN 3480 Class 9 surcharge | Per IMO IMDG Code for lithium batteries; UN 38.3 test summary required (Pylontech US5000 datasheet section "Transport") |

### 3.3 Senegal clearance & last mile

| Line | Item | Source |
| --- | --- | --- |
| D-1 | DD 20% (ECOWAS CET band 4 on CIF) | Senegal Douanes portal · ECOWAS CET 2015 |
| D-2 | UEMOA statistical levy 1% (PCS) on CIF | Senegal Douanes portal |
| D-3 | TVA 18% on (CIF + DD + PCS) | Senegal Douanes portal · DGID Code Général des Impôts |
| D-4 | Customs broker fees + ASYCUDA processing | Senegal Douanes broker schedule |
| D-5 | Port handling at PAD (THC, ISPS) | Port Autonome de Dakar tariff |
| D-6 | Last-mile transport PAD → farm site | Freight forwarder RFQ |
| D-7 | OEM commissioning & operator training | Tradvolt service rate card |

## 4. OpEx — annual operating cost (per US5000 4-module rig)

| Line | Item | Frequency |
| --- | --- | --- |
| O-1 | Routine inspection, torque checks on DC terminals per Deye SUN-5K-SG04LP3-EU user manual, firmware updates | 1× / year |
| O-2 | BMS telemetry / remote monitoring subscription | Monthly |
| O-3 | PV array cleaning (dust-season impact, ~Mar–Jun Harmattan) | 4× / year |
| O-4 | Insurance (asset all-risk, local underwriter) | Annual |
| O-5 | Spare parts reserve (DC fuses, cooling fans, contactor) | Annual provision |
| O-6 | Decommissioning / recycling provision (LFP) | Annual accrual against 20-yr life |

## 5. Payback & sensitivity (computed from the bounded assumption set)

**Method.** Year-by-year cashflow with discount factor 1/(1+0.08)t; the OpEx line escalates at 2.00% per year; benefits decline with battery degradation (round-trip efficiency 92%, usable depth 95%, 2.00% capacity fade per year). Sensitivity recomputes each cell with its own displaced-kWh × price − OpEx cashflow.

### 5.1 Bounded inputs

| Symbol | Meaning | Value |
| --- | --- | --- |
| C₀ | Total landed CapEx (US5000 4-module rack + Deye SUN-5K-SG04LP3-EU + PV + BoM + freight + duty stack + install) | USD 6,200 per site |
| Pd | Displaced diesel cost (Senegal farm-gate) | USD 0.38 / kWh (diesel + maintenance) |
| Euse,0 | Year-1 kWh displaced from diesel | 5,032 kWh (≈ 13.79 kWh/day) |
| Degradation | Asset ESS capacity fade per year | 2.00% per year |
| DoD / RTE | Usable DoD / round-trip efficiency | 95% / 92% |
| Cop,0 | Year-1 OpEx | USD 220 / yr |
| OpEx escalation | o_m.escalation_pct | 2.00% per year |
| r | Discount rate (finance) | 8.00% |
| R | Discount rate (model) | 8.00% |
| Residual value | amount / year | USD 0 / 20 (terminal value excluded for conservatism) |
| Asset ESS charge cost per kWh | Per-kWh charge cost (PV marginal) | USD 0.00 / kWh (PV-sourced) |
| Avoided CO₂ (info) | Annual | ≈ 2.6 t CO₂/yr at ~0.71 kg CO₂/kWh diesel-equivalent |

### 5.2 TCO summary (verbatim computed figures)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 20 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 11,545.42 |
| Total discounted cost / PV of costs (USD) | 8,697.71 |
| Total undiscounted benefit (USD) | 23,674.55 |
| Total discounted benefit (USD) | 12,204.59 |
| NPV (USD) | 3,506.89 |
| IRR | 0.1597 |
| Simple payback (year) | 5.48 |
| Discounted payback (year) | 7.71 |
| LCOS (USD/kWh) | 0.2060 |

### 5.3 Year-by-year cash flow (verbatim computed figures)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 6,200.00 | 0.0000 | -6,200.00 | 1.00 | -6,200.00 | 0.0000 |
| 1 | 220.00 | 1,424.50 | 1,204.50 | 0.9259 | 1,115.27 | 4,927.50 |
| 2 | 224.40 | 1,396.01 | 1,171.61 | 0.8573 | 1,004.46 | 4,828.95 |
| 3 | 228.89 | 1,368.09 | 1,139.20 | 0.7938 | 904.33 | 4,732.37 |
| 4 | 233.47 | 1,340.72 | 1,107.26 | 0.7350 | 813.87 | 4,637.72 |
| 5 | 238.14 | 1,313.91 | 1,075.77 | 0.6806 | 732.15 | 4,544.97 |
| 6 | 242.90 | 1,287.63 | 1,044.73 | 0.6302 | 658.36 | 4,454.07 |
| 7 | 247.76 | 1,261.88 | 1,014.12 | 0.5835 | 591.73 | 4,364.99 |
| 8 | 252.71 | 1,236.64 | 983.93 | 0.5403 | 531.59 | 4,277.69 |
| 9 | 257.77 | 1,211.91 | 954.14 | 0.5002 | 477.31 | 4,192.13 |
| 10 | 262.92 | 1,187.67 | 924.75 | 0.4632 | 428.34 | 4,108.29 |
| 11 | 268.18 | 1,163.92 | 895.74 | 0.4289 | 384.17 | 4,026.13 |
| 12 | 273.54 | 1,140.64 | 867.10 | 0.3971 | 344.34 | 3,945.60 |
| 13 | 279.01 | 1,117.83 | 838.81 | 0.3677 | 308.43 | 3,866.69 |
| 14 | 284.59 | 1,095.47 | 810.88 | 0.3405 | 276.07 | 3,789.36 |
| 15 | 290.29 | 1,073.56 | 783.27 | 0.3152 | 246.92 | 3,713.57 |
| 16 | 296.09 | 1,052.09 | 756.00 | 0.2919 | 220.67 | 3,639.30 |
| 17 | 302.01 | 1,031.05 | 729.03 | 0.2703 | 197.04 | 3,566.51 |
| 18 | 308.05 | 1,010.43 | 702.37 | 0.2502 | 175.77 | 3,495.18 |
| 19 | 314.21 | 990.22 | 676.00 | 0.2317 | 156.64 | 3,425.28 |
| 20 | 320.50 | 970.41 | 649.91 | 0.2145 | 139.44 | 3,356.77 |

### 5.4 Sensitivity (one-variable, recomputed with its own displaced-kWh × price − OpEx cashflow)

| Variable | −20% case | Base | +20% case | Simple payback range (yr) | NPV range (USD) |
| --- | --- | --- | --- | --- | --- |
| Displaced diesel price Pd (USD/kWh) | 0.304 | 0.38 | 0.456 | 7.06 / 5.48 / 4.51 | −50 / 3,507 / 6,961 |
| Annual kWh displaced Euse,0 (kWh/yr, year-1) | 4,025.6 | 5,032.0 | 6,038.4 | 6.81 / 5.48 / 4.58 | 1,068 / 3,507 / 5,946 |
| Land-cost CapEx C₀ (USD) | 4,960 | 6,200 | 7,440 | 4.39 / 5.48 / 6.58 | 4,747 / 3,507 / 2,267 |
| Annual OpEx Cop,0 (USD/yr) | 176 | 220 | 264 | 5.42 / 5.48 / 5.54 | 3,587 / 3,507 / 3,427 |

Payback is most sensitive to **diesel price** and **annual kWh displaced** (farm load profile and irradiation year-on-year). Battery degradation at 2.00% per year is consistent with the Pylontech US5000 cycle-life claim of 6,000 cycles at 90% DoD; the model does not credit any residual asset value at year 20.

## 6. Compliance & certifications

| Standard / scheme | Scope | Status |
| --- | --- | --- |
| IEC 62619 | Secondary lithium cells for industrial applications (incl. stationary storage) | Pylontech US5000 is supplied with an IEC 62619 test certificate; certificate number and issuer appear on the Pylontech US5000 datasheet PDF |
| UN 38.3 | Transport of lithium batteries (T1 altitude, T2 thermal, T3 vibration, T4 shock, T5 external short circuit, T6 impact, T7 overcharge, T8 forced discharge) | Pylontech US5000 datasheet includes the UN 38.3 test summary; transport classification **UN 3480, Class 9**, per IMO IMDG Code |
| IEC 62133-2 | Secondary lithium cells for portable applications (safety) | Pylontech US5000 datasheet also references IEC 62133-2; cite the certificate number on request |
| CE marking (EMC + LVD) | Deye SUN-5K-SG04LP3-EU inverter subassembly | CE Declaration of Conformity is issued with the inverter (Deye SUN-5K-SG04LP3-EU product page) |
| ECOWAS harmonised standards list | Acceptance for Senegal / UEMOA market access | ECOWAS CET 2015 schedule is the operative band classification for HS heading 8507 |
| Shipment classification | UN 3480 (lithium batteries, standalone) Class 9, per IMO IMDG Code | Required for sea-freight booking — confirmed via carrier dangerous-goods form |

Certificate numbers are quoted on the Pylontech US5000 datasheet (PDF) and are not repeated as "No.1" / "verified supplier" claims on this page.

## 7. Spec & datasheet download

Download the Tradvolt product sheet (Pylontech US5000 4-module rig + Deye SUN-5K-SG04LP3-EU inverter, OEM datasheet mirror, UN 38.3 test summary, IEC 62619 certificate to be inserted once verified):

[Download Pylontech US5000 datasheet (PDF)](https://www.pylontech.com.cn/upload/US5000_Datasheet.pdf) Download Tradvolt TCO pack (PDF)

The first link resolves to Pylontech's US5000 datasheet PDF on pylontech.com.cn. The TCO pack is sent together with the RFQ reply.

## 8. Request a quote

**Request Quote — replies in 48h.** All fields below are required so that the duty-stack block can be filled with real numbers and the datasheet customised to your destination.

## 9. FAQ

### 9.1 What HS code applies to LFP batteries imported into Senegal?

Heading 8507 (electric accumulators), lithium-ion sub-position 8507.60. Senegal applies a 20% CET duty under the ECOWAS Common External Tariff on this line (band 4 of the CET 2015 schedule). The precise Senegal national 10-digit line and any chapter-note exception must be confirmed on the [Senegal Douanes tariff portal](https://www.douanes.sn/) before quotation.

### 9.2 What duties and taxes are payable on a Pylontech US5000 imported into Senegal?

Senegal applies the ECOWAS CET 20% duty (band 4) on HS 8507.60, the UEMOA statistical levy (PCS) 1% on CIF, and TVA 18% on (CIF + duty + levies), per the [Senegal Douanes portal](https://www.douanes.sn/) and the UEMOA acts. Verify each line on douanes.sn before a binding quote is issued.

### 9.3 Which certifications should I request from the OEM?

At minimum: **IEC 62619** (secondary lithium cells for industrial applications) and **UN 38.3** (lithium battery transport, UN 3480 Class 9, per the IMO IMDG Code) on the Pylontech US5000 datasheet. For the Deye SUN-5K-SG04LP3-EU inverter: a **CE marking** Declaration of Conformity (EMC + LVD). Certificate numbers and issuing bodies appear on the OEM datasheet PDF.

### 9.4 Is the payback shown on this page a real quote?

No. NPV USD 3,506.89, simple payback 5.48 yr, discounted payback 7.71 yr and LCOS USD 0.2060/kWh are computed from the bounded assumption set in section 5.1 (placeholder landed CapEx USD 6,200, displaced diesel USD 0.38/kWh, discount rate 8.00%, 2.00%/yr OpEx escalation, 2.00%/yr battery degradation, 95% DoD, 92% round-trip efficiency). A binding quote is produced only after the RFQ form is submitted.

### 9.5 What is the typical landed-cost composition for a 15 kWh LFP rack into Dakar?

Typical composition for a CN → Dakar shipment: OEM unit price (FOB), pre-carriage to Chinese port, ocean freight to Port of Dakar, marine insurance, ECOWAS CET 20% DD on CIF, UEMOA 1% statistical levy on CIF, TVA 18% on (CIF + DD + PCS), customs broker fees (ASYCUDA), port handling at PAD (THC, ISPS), last-mile transport to farm site, OEM commissioning. See sections 2, 3 and 6 for line items, rates and sources.