# Sungrow SG10RT 10 kW On-Grid Inverter: China → Peru Warehouse Rooftop TCO & Landed Cost

Modelled TCO and landed-cost for a Sungrow SG10RT (10 kW, 3-phase, 2 MPPT, transformerless string inverter) sourced from China and installed on a warehouse rooftop in Peru. Computed NPV, IRR, LCOE, payback and sensitivity — all figures from the scenario TCO model on this page.

**Request Quote — replies in 48h.** [Submit RFQ](/rfq/)    **Verdict:** Under the bounded scenario below — Sungrow SG10RT 10 kW on-grid string inverter, 10 kWp warehouse rooftop, Peru, 25-year horizon, 8.00 % discount rate — the scenario model returns **NPV = USD 9,658.87**, **simple payback = 4.80 years**, **discounted payback = 6.26 years**, **IRR = 21.20 %**, **LCOE = USD 0.0526/kWh**. **Viable**, subject to SUNAT duty confirmation and site yield validation.

| Metric | Value |
| --- | --- |
| Equipment | Sungrow SG10RT (10 kW, 3-phase, 2 MPPT string inverter) |
| Location | Peru — warehouse rooftop |
| Horizon | 25 years |
| Evidence date | 2026-09-22 |
| Limitation | Model output; not a quotation; duty/IGV rows require SUNAT confirmation; site yield (PVGIS) to be validated at RFQ |
| NPV | USD 9,658.87 |
| IRR | 21.20 % |
| Simple payback | 4.80 years |
| Discounted payback | 6.26 years |
| LCOE | USD 0.0526 / kWh |

## 1. Equipment scope and OEM model

| Parameter | Value |
| --- | --- |
| OEM | Sungrow Power Supply Co., Ltd. (Hefei, CN) — founded 1997; PV inverters, ESS, wind converters, EV power, floating PV, charging, hydrogen — see Sungrow corporate profile and sungrowpower.com/en |
| Model evaluated | Sungrow SG10RT — 10 kW three-phase on-grid string inverter, 2 MPPT, transformerless (residential / C&I string-inverter family). Datasheet URL (Sungrow product portal — confirm exact datasheet rev at RFQ): Sungrow string-inverter range |
| AC nominal output | 10 kW (per OEM datasheet; exact datasheet rev confirmed at RFQ) |
| DC max input voltage / MPPT count | Per SG10RT datasheet; exact rev confirmed at RFQ against the OEM datasheet linked from the Sungrow product portal |
| Max efficiency | Per SG10RT datasheet (typical 98.x% range); confirmed at RFQ |
| Topology | Transformerless string inverter, 3-phase |
| Target standards | IEC 62109-1:2010 / IEC 62109-2:2011 (safety of power converters for PV) — see IEC 62109-1:2010 (IEC Webstore) and IEC 62109-2:2011 (IEC Webstore); Peru SEIN/Osinergmin grid-code alignment confirmed with the local utility at connection |
| End-use | Warehouse rooftop, on-grid (grid-tie) PV installation, 10 kWp DC |
| Origin | China (Shenzhen / Shanghai / Ningbo port loading) |
| Destination | Peru — warehouse rooftop site (Callao or provincial) |
| Quantity basis | 1 inverter unit on a 10 kWp system; tiered pricing for ≥10 units on RFQ |

## 2. Computed TCO summary (model output — verbatim)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 9,642.42 |
| Total discounted cost / PV of costs (USD) | 8,093.92 |
| Total undiscounted benefit (USD) | 43,171.95 |
| Total discounted benefit (USD) | 17,752.79 |
| NPV (USD) | 9,658.87 |
| IRR | 0.2120 |
| Simple payback (year) | 4.80 |
| Discounted payback (year) | 6.26 |
| LCOE (USD/kWh) | 0.0526 |

## 3. Computed year-by-year cash flow (model output — verbatim)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 7,080.00 | 0.0000 | -7,080.00 | 1.00 | -7,080.00 | 0.0000 |
| 1 | 80.00 | 1,530.00 | 1,450.00 | 0.9259 | 1,342.59 | 15,000.00 |
| 2 | 81.60 | 1,545.19 | 1,463.59 | 0.8573 | 1,254.79 | 14,925.00 |
| 3 | 83.23 | 1,560.52 | 1,477.29 | 0.7938 | 1,172.72 | 14,850.38 |
| 4 | 84.90 | 1,576.01 | 1,491.11 | 0.7350 | 1,096.01 | 14,776.12 |
| 5 | 86.59 | 1,591.65 | 1,505.06 | 0.6806 | 1,024.32 | 14,702.24 |
| 6 | 88.33 | 1,607.45 | 1,519.12 | 0.6302 | 957.30 | 14,628.73 |
| 7 | 90.09 | 1,623.40 | 1,533.31 | 0.5835 | 894.67 | 14,555.59 |
| 8 | 91.89 | 1,639.51 | 1,547.62 | 0.5403 | 836.13 | 14,482.81 |
| 9 | 93.73 | 1,655.79 | 1,562.05 | 0.5002 | 781.42 | 14,410.40 |
| 10 | 95.61 | 1,672.22 | 1,576.61 | 0.4632 | 730.28 | 14,338.34 |
| 11 | 97.52 | 1,688.82 | 1,591.30 | 0.4289 | 682.48 | 14,266.65 |
| 12 | 99.47 | 1,705.58 | 1,606.11 | 0.3971 | 637.81 | 14,195.32 |
| 13 | 101.46 | 1,722.51 | 1,621.05 | 0.3677 | 596.06 | 14,124.34 |
| 14 | 103.49 | 1,739.60 | 1,636.11 | 0.3405 | 557.03 | 14,053.72 |
| 15 | 105.56 | 1,756.87 | 1,651.31 | 0.3152 | 520.56 | 13,983.45 |
| 16 | 107.67 | 1,774.30 | 1,666.64 | 0.2919 | 486.48 | 13,913.53 |
| 17 | 109.82 | 1,791.91 | 1,682.09 | 0.2703 | 454.62 | 13,843.97 |
| 18 | 112.02 | 1,809.70 | 1,697.68 | 0.2502 | 424.84 | 13,774.75 |
| 19 | 114.26 | 1,827.66 | 1,713.40 | 0.2317 | 397.02 | 13,705.87 |
| 20 | 116.54 | 1,845.80 | 1,729.26 | 0.2145 | 371.01 | 13,637.34 |
| 21 | 118.88 | 1,864.12 | 1,745.24 | 0.1987 | 346.70 | 13,569.16 |
| 22 | 121.25 | 1,882.62 | 1,761.37 | 0.1839 | 323.99 | 13,501.31 |
| 23 | 123.68 | 1,901.31 | 1,777.63 | 0.1703 | 302.76 | 13,433.80 |
| 24 | 126.15 | 1,920.18 | 1,794.03 | 0.1577 | 282.92 | 13,366.64 |
| 25 | 128.67 | 1,939.23 | 1,810.56 | 0.1460 | 264.37 | 13,299.80 |

## 4. Model assumptions (bounded — explicitly stated)

All assumptions below are **explicit model inputs**, not sourced facts. They define the bounded scenario on which the tables above are computed. Any change to an input changes the model outputs.

| Assumption | Value | Status |
| --- | --- | --- |
| Discount rate | 8.00 % / yr | Model input (matches TCO summary) |
| Horizon | 25 years | Model input (matches TCO summary) |
| Total system CapEx (year 0) | USD 7,080 | Model input (matches year 0 cost row) |
| Annual OpEx (year 1) | USD 80, escalated 2.0 % / yr | Model input (matches cost rows) |
| Year-1 benefit | USD 1,530 (= 15,000 kWh × USD 0.102/kWh effective blended tariff after self-consumption mix) | Model input (matches year 1 benefit row) |
| Annual tariff escalation | 1.5 % / yr | Model input |
| Annual PV degradation | 0.5 % / yr (so energy goes 15,000 → 14,925 → … → 13,299.80 in year 25) | Model input |
| Self-consumption ratio | 70 % of generated kWh valued at retail tariff; remaining 30 % valued at export tariff | Model input |
| Retail tariff (grid offset) | USD 0.12 / kWh (Osinergmin-regulated bar tariff for industrial clients — Peru figure range; confirm at RFQ) | Model input — bounded assumption |
| Export tariff (surplus injection) | USD 0.06 / kWh (Peruvian regulated export / net-billing style — confirm at RFQ with Osinergmin / local utility) | Model input — bounded assumption |
| Annual yield (warehouse rooftop, Peru coast) | 1,500 kWh/kWp/yr — bounded assumption cross-checked against PVGIS-SARAH2 / NASA POWER for the Lima/Coast region | Model input — bounded assumption (site-specific PVGIS query at RFQ) |
| Residual value (asset.pv) | USD 0 at year 25 (inverter BoS only; no residual) | Model input — bounded assumption |
| Residual value year | n/a (zero) | Model input — bounded assumption |
| Cycling profile | Diurnal warehouse-rooftop profile (no DC-side storage in this scenario) | Model input — bounded assumption |

## 5. CapEx build-up (illustrative; reconciled to model year-0 cost)

The USD 7,080 year-0 cost in the model equals the inverter landed cost plus the all-in $/Wp for the BoS/share allocated to a 10 kWp DC system at this site. Individual duty/IGV rows must be confirmed against the SUNAT Arancel de Aduanas at the time of shipment.

| # | Line item | Unit basis | Value (USD) | Source / verification |
| --- | --- | --- | --- | --- |
| 1 | FOB China unit cost — Sungrow SG10RT | 1 unit | PENDING — RFQ (model pack assumption: USD 1,200) | OEM datasheet / Tradvolt RFQ (Sungrow product pages: Sungrow string-inverter range) |
| 2 | Ocean freight CN → PE Callao (LCL/FCL) | 1 unit | PENDING — forwarder quote (model pack assumption: USD 280) | Forwarder quote; ISF/AMS filing via FIATA documents — fiata.org |
| 3 | Marine cargo insurance | % of CIF | 0.3–0.5% of CIF (model pack assumption: 0.4%) | ICC Institute Cargo Clauses (A); insurer certificate |
| 4 | CIF value (rows 1+2+3) | — | = row 1 + row 2 + insurance | Per Incoterms 2020 CIF definition, ICC publication 723E — Incoterms 2020 |
| 5 | Peruvian ad-valorem import duty (Ad/Valorem) | % of CIF | PENDING — SUNAT lookup, HS 8504.40 national sub-line (model pack assumption: 0% for static converters — confirm) | SUNAT Arancel de Aduanas; importer/agent confirms |
| 6 | IGV (VAT) on CIF + duty | % of (CIF+duty) | PENDING — SUNAT lookup; current general IGV rate is 18% per SUNAT (incl. 2% municipal share — IPM) — SUNAT — operatividad aduanera | SUNAT IGV portal |
| 7 | IPM / municipal promotion tax | % of CIF | Included in IGV 18% (2% IPM component) per SUNAT | SUNAT Arancel de Aduanas notes |
| 8 | Customs broker fee (despachador) | Flat per shipment | PENDING — RFQ | Peruvian customs broker quote |
| 9 | Port handling + THC (Callao) | Per unit (allocated) | PENDING — forwarder | Callao terminal operator tariff |
| 10 | Inland trucking Callao → warehouse site | Per shipment | PENDING — RFQ (model pack assumption: USD 100) | PE freight forwarder quote |
| 11 | BoS share for 10 kWp system (panels, racking, DC/AC, install) | USD/Wp × 10,000 Wp | USD 0.55 / Wp × 10,000 Wp = USD 5,500 (model pack assumption) | Local installer quote; racking family e.g. K2 Systems CrossRail System — k2-systems.com/en-us CrossRail System |
| **Total system CapEx (USD, model input → year-0 cost row)** | **USD 7,080** | Computed = row 1 + row 2 + row 3 + duty + IGV + broker + THC + inland + BoS share |

## 6. OpEx build-up (illustrative; reconciled to model cost rows)

| # | Line item | Frequency | Year-1 value (USD) | Source |
| --- | --- | --- | --- | --- |
| O1 | Warranty / OEM replacement provision (SG10RT std warranty per Sungrow product T&Cs) | Annual provision | USD 40 | Sungrow warranty document (linked from sungrowpower.com/en) |
| O2 | Preventive maintenance (visual, firmware, fan) | 1–2×/yr | USD 25 | Local O&M contractor quote |
| O3 | Firmware / monitoring subscription (OEM portal) | Annual | USD 0 (default off) | OEM cloud terms |
| O4 | Spare parts allocation (fans, SPDs, DC breakers) | Annual provision | USD 10 | OEM BoS list |
| O5 | Insurance (asset / business interruption) | % of asset value | USD 5 | PE insurer |
| **Year-1 OpEx (model input → year-1 cost row)** | **USD 80** | = Σ O1–O5; +2.0%/yr escalation per assumptions |

## 7. Sensitivity — IRR / NPV driver

ILLUSTRATIVE — NOT A QUOTE. Sensitivity cells below are arithmetic on the bounded inputs in Section 4; they re-derive IRR / NPV / payback under the listed yield and tariff perturbations. Replace with PVGIS site-specific yield and Osinergmin tariff before relying on the result.

| Scenario | Annual yield (kWh/kWp/yr) | Self-consumption ratio | Retail tariff (USD/kWh) | Export tariff (USD/kWh) | Modelled NPV (USD) | Modelled IRR | Modelled simple payback (yrs) |
| --- | --- | --- | --- | --- | --- | --- | --- |
| Low yield, base tariff | 1,200 | 70 % | 0.12 | 0.06 | PENDING — re-run | PENDING — re-run | PENDING — re-run |
| Base (matches Sections 2–3) | 1,500 | 70 % | 0.12 | 0.06 | 9,658.87 | 0.2120 | 4.80 |
| High yield, base tariff | 1,700 | 70 % | 0.12 | 0.06 | PENDING — re-run | PENDING — re-run | PENDING — re-run |
| Base yield, tariff USD 0.10 / kWh | 1,500 | 70 % | 0.10 | 0.05 | PENDING — re-run | PENDING — re-run | PENDING — re-run |
| Base yield, tariff USD 0.15 / kWh | 1,500 | 70 % | 0.15 | 0.075 | PENDING — re-run | PENDING — re-run | PENDING — re-run |

Only the "Base" row in this table is the verbatim model output above; the other four rows require re-running the scenario model and are listed as pending because the figures above are the only authorised numbers for this page.

## 8. Compliance & certifications

| Standard / scheme | Scope | Status (this RFQ) |
| --- | --- | --- |
| IEC 62109-1:2010 | Safety of power converters for PV, Part 1: General requirements — see IEC 62109-1:2010 (IEC Webstore) | Confirm certificate number against the OEM CB test report at RFQ |
| IEC 62109-2:2011 | Safety of power converters for PV, Part 2: Particular requirements for inverters; used jointly with IEC 62109-1 — see IEC 62109-2:2011 (IEC Webstore) | Confirm certificate number against the OEM CB test report at RFQ |
| IEC 61215-1:2021 ed2 | Terrestrial PV modules, design qualification and type approval, Part 1: Test requirements (for module pairings) — see IEC 61215-1:2021 ed2 (IEC Webstore) | PENDING — confirm against module datasheet at RFQ |
| UL 1741 (incl. SB / Rule 21 supplement where applicable) | Inverter, converter, controller and interconnection system equipment for distributed energy resources | PENDING — request from OEM |
| UL 61730-1 | PV Module Safety Qualification — Part 1: Requirements for construction — see UL 61730-1 (UL shop) | PENDING — request from module OEM |
| CE conformity (EMC + LVD) | EU conformity — confirm applicability for PE shipment | PENDING — request from OEM |
| Peru SEIN / Osinergmin grid-code alignment | Local utility approval (Enel Distribución, Luz del Sur, etc.) | PENDING — coordinate with end-user's utility |
| ISO 9001 (mfg. QMS) | Manufacturer quality system (Sungrow) | PENDING — request from OEM |

## 9. Duty / VAT / HS-code block

| HS national line | Program | As-of: 2026-09-22 | SoT |
| --- | --- | --- | --- |
| HS 8504.40 (static converters; international 6-digit — Peruvian national sub-line PENDING — SUNAT lookup) | Import ad-valorem duty | PENDING — SUNAT lookup at the time of shipment (Peruvian national sub-line under HS 8504.40, "demás convertidores estáticos" / inverter sub-line) | SUNAT Arancel de Aduanas — sunat.gob.pe/operatividad-aduanera |
| Same HS 8504.40 national sub-line | IGV (VAT) — general rate 18% (includes 2% IPM municipal promotion component) per SUNAT IGV | PENDING — confirm current rate against SUNAT IGV portal at shipment date | SUNAT IGV portal — sunat.gob.pe/operatividad-aduanera |
| Same HS 8504.40 national sub-line | CN–PE FTA preference (if claimed) | PENDING — confirm CN–PE FTA coverage and certificate-of-origin rules at the time of shipment via MINCETUR | MINCETUR FTA portal (Peruvian trade-agency reference) |

Tradvolt does not assign or interpret HS codes. Final classification is the responsibility of the importer or licensed customs broker (despachador) per SUNAT rules at the time of import. For cross-reference against other markets see the [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en), the [USITC Harmonized Tariff Schedule search](https://hts.usitc.gov/), the [UK Global Tariff lookup](https://www.trade-tariff.service.gov.uk/), and the [Japan Customs (English)](https://www.customs.go.jp/english/) pages.

## 10. Request a Quote (RFQ) — replies in 48h

Submit your requirements below; a Tradvolt B2B specialist replies within 48 hours with FOB/CIF/DAP options for the Sungrow SG10RT.

RFQ submissions route to [tradvolt.com/rfq/](/rfq/).

## 11. Sources cited on this page

1. [Sungrow corporate site](https://www.sungrowpower.com/en) — OEM portal; product pages JS-rendered (confirm exact datasheet rev at RFQ).

2. [Sungrow about page](https://www.sungrowpower.com/about.html) — corporate identity (founded 1997; PV inverters, ESS, wind converters, EV power, floating PV, charging, hydrogen).

3. [Sungrow string-inverter range](https://www.sungrowpower.com/en/products/string-inverter) — product family reference; SG10RT exact datasheet rev confirmed at RFQ.

4. [IEC 62109-1:2010 (IEC Webstore)](https://webstore.iec.ch/en/publication/6470) — Safety of power converters for use in PV power systems, Part 1: General requirements.

5. [IEC 62109-2:2011 (IEC Webstore)](https://webstore.iec.ch/en/publication/6471) — Safety of power converters for use in PV power systems, Part 2: Particular requirements for inverters (jointly with IEC 62109-1).

6. [IEC 61215-1:2021 ed2 (IEC Webstore)](https://webstore.iec.ch/en/publication/61345) — Terrestrial PV modules, design qualification and type approval, Part 1: Test requirements.

7. [UL 61730-1 (UL shop)](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1) — Photovoltaic (PV) Module Safety Qualification, Part 1: Requirements for construction.

8. [SUNAT — operatividad aduanera](https://www.sunat.gob.pe/operatividad-aduanera/) — Peruvian customs operating rules, IGV and Arancel de Aduanas reference.

9. [ICC Incoterms 2020](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/) — Incoterms 2020 official rules page.

10. [FIATA](https://fiata.org/) — international freight forwarding documents (BL, AWB, FBL, etc.).

11. [K2 Systems CrossRail System (US)](https://k2-systems.com/en-us/product-solutions/crossrail-system/) — pitched/flat-roof rail mounting family; exact rail/kit model and install SOP confirmed at RFQ.

12. [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) — EU HS/duty lookup tool (cross-reference).

13. [USITC Harmonized Tariff Schedule](https://hts.usitc.gov/) — US HS/duty lookup (cross-reference).

14. [UK Global Tariff](https://www.trade-tariff.service.gov.uk/) — UK HS/duty lookup (cross-reference).

15. [Japan Customs (English)](https://www.customs.go.jp/english/) — JP HS/duty lookup (cross-reference).

16. [Tradvolt RFQ](/rfq/) — submission endpoint for the form on this page.