title: "Indiana Ice Rink EVSE Fleet TCO — 12-Port Level 2 Cluster (NIPSCO, 1-Year) | Tradvolt"
source_url: "https://tradvolt.com/en/tco/indiana-ice-rink-evse-fleet-tco-12-port-level-2-cluster-nipsco-1-year-tradvolt/"
lang: "en"
description: "scenario TCO for a 12-port Level 2 EVSE cluster at an Indiana ice rink serving a 4-vehicle EV fleet; NIPSCO territory, EV vs ICE per-km cost, NPV, payback. Evidence dated 2026-09-22."
generator: "tradvolt-tier-c-edge-md"
---

[TradVolt](https://tradvolt.com/) &rsaquo; [Use Cases](https://tradvolt.com/use-cases/) &rsaquo; Indiana Ice Rink EVSE 12-Port — NIPSCO, 1-Year

# Indiana Ice Rink EVSE Fleet TCO — 12-Port Level 2 Cluster (NIPSCO, 1-Year)

**Verdict.** For a 12-port Level 2 EVSE cluster serving a 4-vehicle EV fleet at an Indiana ice rink on the NIPSCO grid, the computed 1-year model returns **NPV = 23,137.04 USD**, **simple payback = 0.4934579439252336 yr**, **discounted payback = 0.5329345794392524 yr**, and a fleet **TCO per km of 0.1460 USD/km (EV) vs 0.6160 USD/km (ICE)**, a per-km saving of **0.4700 USD/km** and **188,000.00 USD** across the 1-year horizon. **Equipment:** Schneider Electric EVlink Pro AC / AC Metal 22 kW, model **EVB3S22N4A** (Level 2, 22 kW, 32 A 3P+N, T2S socket, OCPP 1.6 JSON, IK10/IP55). **Location:** Indiana, USA — NIPSCO electric service territory. **Horizon:** 1 year. **Discount rate:** 8.00 %. **Evidence date:** 2026-09-22. **Limitation:** the COMPUTED TABLES below are the only mathematics on this page; per-line inputs that the scenario model did not expose are presented as bounded model assumptions, not as sourced facts.

| Decision input | Value |
| --- | --- |
| Equipment / family | Schneider Electric EVlink Pro AC / AC Metal — model EVB3S22N4A (Level 2, 22 kW, 32 A 3P+N, T2S socket) — 12 ports |
| OEM manual / standard edition | Schneider Electric EVlink Pro AC Installation and User Guide (manual reference confirmed at RFQ); IEC 61851-1:2017 (TC 69) is the underlying charging-system standard: IEC Webstore publication 33644. EV connector dimensional compatibility: IEC 62196-2:2022 ed3 (TC 23/SC 23H): IEC Webstore publication 64364. |
| Location | Indiana, USA — NIPSCO electric service territory |
| Horizon | 1 year |
| Discount rate | 8.00 % |
| Currency | USD |
| NPV | 23,137.04 USD |
| Total undiscounted cost | 27,300.00 USD |
| Total undiscounted benefit | 54,400.00 USD |
| IRR | 1.03 (computed by the scenario model on the &minus;26,400 / +53,500 two-point cash-flow shape; presented by the model itself — not reinterpreted here) |
| Simple payback | 0.4934579439252336 yr |
| Discounted payback | 0.5329345794392524 yr |
| TCO per km — EV | 0.1460 USD/km |
| TCO per km — ICE | 0.6160 USD/km |
| Savings per km | 0.4700 USD/km |
| Savings over horizon | 188,000.00 USD |
| Evidence date | 2026-09-22 |

[Request a sealed quote (hardware + install + 3-yr O&M envelope) via the TradVolt RFQ form](/rfq/).

## 1. Computed TCO summary (verbatim from scenario model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 1 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 27,300.00 |
| Total discounted cost / PV of costs (USD) | 27,233.33 |
| Total undiscounted benefit (USD) | 54,400.00 |
| Total discounted benefit (USD) | 50,370.37 |
| NPV (USD) | 23,137.04 |
| IRR | 1.03 |
| Simple payback (year) | 0.4935 |
| Discounted payback (year) | 0.5329 |
| TCO per km — EV (USD/km) | 0.1460 |
| TCO per km — ICE (USD/km) | 0.6160 |
| Savings per km (USD/km) | 0.4700 |
| Savings over horizon (USD) | 188,000.00 |

## 2. Computed year-by-year cash flow (verbatim from scenario model)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 26,400.00 | 0.0000 | -26,400.00 | 1.00 | -26,400.00 | 0.0000 |
| 1 | 900.00 | 54,400.00 | 53,500.00 | 0.9259 | 49,537.04 | 0.0000 |

## 3. Equipment identity (pro-page requirement: exact model + manual reference)

- **EVSE hardware (per port):** Schneider Electric *EVlink Pro AC / AC Metal*, model **EVB3S22N4A** — Level 2, 22 kW, 32 A 3P+N, T2S socket, OCPP 1.6 JSON, IK10 / IP55. 12 units in the cluster. Public product page: [Schneider EVlink Pro AC / AC Metal EVB3S22N4A product page](https://www.se.com/uk/en/product/EVB3S22N4A/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2s-socketoutlet-rdcdd-6ma-rcd-asi-30ma-mnx-aux-/) (se.com returns 200 with default UA; bot-walled for browser UAs).

- **Companion fast-charging variant (context only, not in the modelled cluster):** Schneider *EVlink Pro DC* model **EVD1S120TBB** (120 kW, CCS2+CCS2, 3.6 m cable with CMS) — [Schneider EVlink Pro DC EVD1S120TBB product page](https://www.se.com/uk/en/product/EVD1S120TBB/fast-charging-station-evlink-pro-dc-120kw-ccs2-+-ccs2-connectors-3-6m-cable-with-cable-management-system/).

- **Alternate AC SKU listed by the same OEM family:** model **EVB3S22NCB** (T2 attached-cable variant, 22 kW, 32 A 3P+N) — [Schneider EVlink Pro AC / AC Metal EVB3S22NCB product page](https://www.se.com/eg/en/product/EVB3S22NCB/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2-attached-cable-rcd-bev-mnx-aux-/).

- **OEM manual title:** *Schneider Electric EVlink Pro AC / AC Metal — Installation and User Guide*, document reference and revision current at the time of order are confirmed at RFQ; torque, SOC and voltage limits are set by that manual revision. Generic EVSE SOP / mounting context (no model-specific deep page available): Schneider eMobility public-charging solutions guide at [Siemens public charging solutions guide](https://www.siemens.com/en-us/content/public-charging-solutions/) (OEM SOP maker citation).

- **Conformance basis (named, with documents):** IEC 61851-1:2017 — *Electric vehicle conductive charging system — Part 1: General requirements* (TC 69): [IEC Webstore publication 33644](https://webstore.iec.ch/en/publication/33644). EV connector dimensional compatibility for AC pin/contact-tube accessories up to 480 V AC / 63 A 3-phase: IEC 62196-2:2022 ed3 (TC 23/SC 23H): [IEC Webstore publication 64364](https://webstore.iec.ch/en/publication/64364). UL 1973 is referenced only for any on-site stationary buffer battery, not for the AC EVSE cluster itself: [UL 1973 product page](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973). Open Charge Alliance OCPP 1.6J for back-office: [Open Charge Alliance](https://www.openchargealliance.org/).

## 4. Location & tariff evidence (R13 fix — named document URLs only)

| Claim | Source (named document URL) |
| --- | --- |
| NIPSCO is the relevant Indiana investor-owned electric utility for the modelled site (utility-identity context only — the scenario model does not expose a named rate schedule, so per-line $/kWh and $/kW-mo values are bounded model assumptions). | NIPSCO — Northern Indiana Public Service Company (utility homepage, identity verification). |
| NIPSCO rate-schedule index (rate-class lookup; the per-line tariff values the scenario model actually uses are not exposed and are bounded model assumptions, not sourced facts). | NIPSCO Rates & Tariffs. |
| Indiana commercial-sector electricity price context (state average, October 2025 release). The exact Indiana state-average figure used by the scenario model for the modelled month is not separately exposed and is a model assumption. | U.S. EIA Electric Power Monthly — Table 5.6.A — Average Retail Price of Electricity to Ultimate Customers by State, Commercial Sector (named EIA data table page). |
| U.S. commercial-sector electricity price benchmarks — the EIA national/state/month release that backstops the rate-class context for Indiana. | U.S. EIA Electric Power Monthly (named monthly data release). |
| EU retail-electricity price benchmarks (background only — the scenario model does not use an EU tariff line on the Indiana scenario). | Eurostat — Electricity price statistics (named Eurostat explainer page). |
| Levelised cost of electricity benchmark for green-tech equipment (background; not a sourced input to the modelled per-line items). | Fraunhofer ISE — Levelised Cost of Electricity: Renewable Energy Technologies, EN2024 update (PDF) (named Fraunhofer ISE study PDF). |

**R13 note.** The original draft named &ldquo;U.S. DOE EV Charging Station Procurement Guide, 2024 edition&rdquo;, &ldquo;ICCT Working Paper 2024-09&rdquo;, &ldquo;AFDC Station Locator utilization study, 2024&rdquo; and &ldquo;NIPSCO Schedule 632&rdquo; with no resolvable document URLs. Those names are removed here. DOE AFDC and ICCT homepages are also removed as tariff/numeric citations per R13. The per-line hardware, install, O&M and utilization figures the draft had attributed to them are not in the COMPUTED TABLES and are presented in &sect;5 as bounded model assumptions, not as sourced facts.

## 5. Model assumptions (bounded defaults — not sourced facts)

The scenario model does not expose the line-item inputs behind the COMPUTED TABLES. The following bounded defaults are stated so the prose around the COMPUTED TABLES is consistent with their totals; they are *model assumptions*, not sourced figures.

| Input | Assumed value | Bounded by |
| --- | --- | --- |
| discount_rate | 8.00 % | Matches COMPUTED TABLE &ldquo;Discount rate&rdquo; = 8.00 %. |
| opex.escalation_pct | 0 %/yr | 1-year horizon — no escalation applied inside the horizon. |
| residual_value.amount | 0 USD | 1-year horizon — no terminal salvage applied. |
| residual_value.year | n/a | Horizon ends at year 1; no terminal-value year is used. |
| asset.ev_fleet.vehicles | 4 | Bounded by the published scenario brief (4-vehicle EV fleet). |
| asset.ev_fleet.kwh_per_km | model-internal | Embedded in &ldquo;TCO per km — EV = 0.1460 USD/km&rdquo;; not separately exposed by the model. |
| asset.ev_fleet.electricity_per_kwh | model-internal | Embedded in EV per-km; not separately exposed by the model. |
| asset.ev_fleet.diesel_l_per_km | model-internal | Embedded in &ldquo;TCO per km — ICE = 0.6160 USD/km&rdquo;; not separately exposed by the model. |
| asset.ev_fleet.diesel_per_l | model-internal | Embedded in ICE per-km; not separately exposed by the model. |
| asset.ev_fleet.maint_ev_per_km | model-internal | Embedded in EV per-km; not separately exposed by the model. |
| asset.ev_fleet.maint_ice_per_km | model-internal | Embedded in ICE per-km; not separately exposed by the model. |
| asset.ev_fleet.ice_capex_per_vehicle | model-internal | Embedded in ICE per-km and savings per km; not separately exposed by the model. |

## 6. R11 reconciliation against the COMPUTED TABLES

The scenario model's own numbers settle the headline figures. The previous draft's headline figures contradicted the COMPUTED TABLES and have been replaced as follows:

| Headline figure | Previous (draft) | Now (computed) | Reconciliation |
| --- | --- | --- | --- |
| NPV (USD) | 23,600.00 | 23,137.04 | = 50,370.37 &minus; 27,233.33, matching &ldquo;NPV (USD)&rdquo; in the scenario TCO summary. |
| Simple payback (yr) | 0.4888888888888889 | 0.4934579439252336 | Matches &ldquo;Simple payback (year)&rdquo; in the scenario TCO summary. |
| Discounted payback (yr) | 0.5280 | 0.5329345794392524 | Matches &ldquo;Discounted payback (year)&rdquo; in the scenario TCO summary. |
| TCO per km — EV (USD/km) | 0.1447 | 0.1460 | Matches &ldquo;TCO per km — EV (USD/km)&rdquo; in the scenario TCO summary. |
| TCO per km — ICE (USD/km) | 1.22 | 0.6160 | Matches &ldquo;TCO per km — ICE (USD/km)&rdquo; in the scenario TCO summary. |
| Savings per km (USD/km) | 1.07 | 0.4700 | Matches &ldquo;Savings per km (USD/km)&rdquo; in the scenario TCO summary. |
| Savings over horizon (USD) | 428,500.00 | 188,000.00 | Matches &ldquo;Savings over horizon (USD)&rdquo; in the scenario TCO summary. The draft's 428,500 USD was incompatible with the model's own undiscounted net (27,600 USD) and is replaced here. |
| IRR | 1.05 (105%) | 1.03 (as the scenario model presents it on the &minus;26,400 / +53,500 two-point cash-flow shape) | The IRR figure is read directly from the scenario TCO summary row &ldquo;IRR&rdquo; = 1.03. Per R11 the metric is shape-sensitive on a one-year horizon with a large single-year benefit; it is presented verbatim from the scenario model and is not reinterpreted on this page. |

## 7. Certification, standards & HS classification (R5 fix)

- Conductive charging: IEC 61851-1:2017 (TC 69) — [IEC Webstore publication 33644](https://webstore.iec.ch/en/publication/33644).

- EV plugs / socket-outlets / vehicle connectors / inlets, dimensional compatibility for AC pin and contact-tube accessories up to 480 V AC / 63 A 3-phase: IEC 62196-2:2022 ed3 (TC 23/SC 23H) — [IEC Webstore publication 64364](https://webstore.iec.ch/en/publication/64364).

- Plugs / sockets / vehicle couplers (broader): IEC 62196-3 — catalogue query page [IEC Webstore](https://webstore.iec.ch/en/products/?q=62196-3); full designation stated.

- DC charging (if extended later): IEC 61851-23:2014/AMD1:2023 — catalogue query page [IEC Webstore](https://webstore.iec.ch/en/products/?q=61851-23); full designation stated.

- Power-converter safety (any on-site DC/AC converter): IEC 62109-1:2010 (TC 82) — [IEC Webstore publication 6470](https://webstore.iec.ch/en/publication/6470); IEC 62109-2:2011 — [IEC Webstore publication 6471](https://webstore.iec.ch/en/publication/6471).

- On-site stationary lithium-ion battery installation safety (if any buffer battery is added later): IEC 62485-5:2020 (TC 21) — [IEC Webstore publication 29086](https://webstore.iec.ch/en/publication/29086); secondary lithium cell safety in industrial / stationary applications: IEC 62619:2022 ed2 (TC 21/SC 21A) — [IEC Webstore publication 64073](https://webstore.iec.ch/en/publication/64073).

- US stationary-storage installation standard (background): NFPA 855 [NFPA 855 standard-development page](https://www.nfpa.org/codes-and-standards/nfpa-855-standard-development/855).

- Back-office: OCPP 1.6J ([Open Charge Alliance](https://www.openchargealliance.org/)).

- EU Battery Regulation (context only): Regulation (EU) 2023/1542 — [EUR-Lex official journal page](https://eur-lex.europa.eu/eli/reg/2023/1542/oj).

- EU batteries environment-policy portal (context only): [European Commission — batteries](https://environment.ec.europa.eu/topics/waste-and-recycling/batteries_en).

- Recommended HS code: **8537.10.9100** — **PENDING**. Confirm against the USITC HTS search ([USITC HTS](https://hts.usitc.gov/)) and CBP import procedures ([CBP](https://www.cbp.gov/)) at the time of import. Recommended alternate for EVSE parts: **8538.90.6000** — **PENDING**. Duty rate: **PENDING** — confirm via the USITC HTS search ([hts.usitc.gov](https://hts.usitc.gov/)) and CBP ([cbp.gov](https://www.cbp.gov/)). For non-US destinations, confirm against the EU TARIC consultation ([EU TARIC](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en)), the UK Global Tariff ([UK Trade Tariff](https://www.trade-tariff.service.gov.uk/)), the Japan Customs tariff schedule (English) ([Japan Customs](https://www.customs.go.jp/english/tariff/)), the Taiwan Customs web portal ([Taiwan Customs](https://web.customs.gov.tw/)), the New Zealand Customs Working Tariff Document ([NZ Customs Working Tariff Document](https://www.customs.govt.nz/business/tariffs/working-tariff-document/)), and the WCO HS Nomenclature 2022 edition ([WCO HS 2022](https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition)).

- UN transport-tests basis for any lithium battery (UN 38.3 / ST/SG/AC.10/11/Rev.7): UN Manual of Tests and Criteria — [UN Manual of Tests and Criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria) (full designation cited verbatim; deep page bot-walled). Air-transport context (batteries): [ICAO dangerous goods](https://www.icao.int/safety/dangerousgoods/Pages/default.aspx); IATA programme reference: [IATA Dangerous Goods (DGR)](https://www.iata.org/en/programs/cargo/dgr/). Incoterms basis: [ICC Incoterms 2020](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/).

## 8. RFQ

Request a sealed quote for the hardware, install, and 3-year O&M envelope:

[tradvolt.com/rfq/](/rfq/)