title: "Industrial Rooftop 700 W Solar Panel from China to Uruguay — TCO & Landed-Cost Brief | Tradvolt"
source_url: "https://tradvolt.com/en/tco/industrial-rooftop-700-w-solar-panel-from-china-to-uruguay-tco-landed-cost-brief-tradvolt/"
lang: "en"
description: "Use-case TCO brief: importing 700 W industrial-rooftop solar panels from China to Uruguay. Scenario model outputs (NPV USD 772,332; simple payback 2.21 yr; discounted payback 2.53 yr; LCOE 0.0316 USD/kWh) with cited sources and Uruguay customs duty stack."
generator: "tradvolt-tier-c-edge-md"
---

[Tradvolt](/)   Use-case · B2B · CN → Uruguay

# Import Solar Panel 700 W from China to Uruguay — Industrial Rooftop TCO

Vertical: industrial rooftop. scenario TCO brief for a 700 W-class PV module landed in Montevideo / free-zone deployment. Model results below are computed from the scenario and are computed; rates and yields remain model assumptions until confirmed by a live RFQ.

[Request Quote — replies in 48h](#rfq) [Download Spec & Datasheet](/rfq)   **Verdict (500 kWp reference, Montevideo, 25-yr horizon, 8.00% discount, USD):** Indicative landed CapEx ~USD 0.27–0.52/Wp, computed **NPV ≈ USD 772,332**, **simple payback ≈ 2.21 yr**, **discounted payback ≈ 2.53 yr**, **LCOE ≈ 0.0316 USD/kWh**, **IRR ≈ 46.29%**. A binding landed-cost offer requires an RFQ with current DNA/DGI duty and VAT lookup plus UTE tariff confirmation — see §8.

| Decision metric | Value | Horizon | Discount rate | Currency |
| --- | --- | --- | --- | --- |
| NPV | USD 772,332.41 | 25 yr | 8.00% | USD |
| IRR | 0.4629 (46.29%) | 25 yr | 8.00% | USD |
| Simple payback | 2.21 yr | 25 yr | 8.00% | USD |
| Discounted payback | 2.53 yr | 25 yr | 8.00% | USD |
| LCOE | 0.0316 USD/kWh | 25 yr | 8.00% | USD |

Evidence date: 2026-09-21. Limitation: DNA import duty, DGI IVA rate, UTE avoided-import tariff and UTE export tariff are model assumptions pending official lookup (see §6); module price range is sourced from BloombergNEF / InfoLink tier-1 indexes; yield from PVGIS (JRC).

## 1. Scope and Module Definition

Reference module class: 700 W-class monocrystalline bifacial / TOPCon PV module intended for industrial-rooftop arrays in Uruguay. Tradvolt treats this as an **unbranded reference class** for the TCO model; specific OEM SKUs are bound to the RFQ and to the OEM datasheets listed in §9. Reference candidates used to ground the price index and datasheet-style limits:

- Jinko Solar — Tiger Neo 3.0 / N-type TOPCon, 700 W-class data sheet: [https://www.jinkosolar.com/uploads/2024/Tiger-Neo-3-0-Datasheet.pdf](https://www.jinkosolar.com/uploads/2024/Tiger-Neo-3-0-Datasheet.pdf)

- Trina Solar — Vertex N 700 W-class TOPCon data sheet: [https://www.trinasolar.com/sites/default/files/2024-04/DA08_UM_EN_2024_A.pdf](https://www.trinasolar.com/sites/default/files/2024-04/DA08_UM_EN_2024_A.pdf)

- LONGi — Hi-MO 7 / Hi-MO X6 (HPBC / TOPCon) product family page: [https://www.longi.com/en/products/modules/](https://www.longi.com/en/products/modules/)

**Module class**: 700 Wp nominal, monocrystalline silicon, bifacial, industrial-rooftop framing.
**Use-case**: grid-connected industrial rooftop, self-consumption + surplus export to UTE grid.
**Origin**: China (CN). **Destination**: Uruguay (UY), port of Montevideo (UYMVD) unless otherwise stated.

## 2. Compliance and Certifications

Uruguay's main off-taker, UTE (Administración Nacional de Usinas y Transmisiones Eléctricas), defines technical requirements for grid-connected PV equipment. The standards typically referenced for PV modules, and the issuing body portals, are:

- IEC 61215-1:2021 / IEC 61215-2:2021 — Crystalline silicon PV modules — Design qualification, IEC Webstore publication page: [https://webstore.iec.ch/en/publication/61350](https://webstore.iec.ch/en/publication/61350)

- IEC 61730-1:2016 / IEC 61730-2:2016 — PV module safety qualification, IEC Webstore publication page: [https://webstore.iec.ch/en/publication/26170](https://webstore.iec.ch/en/publication/26170)

- IEC 61701:2020 — Salt-mist corrosion testing (recommended for coastal Uruguayan sites), IEC Webstore publication page: [https://webstore.iec.ch/en/publication/31414](https://webstore.iec.ch/en/publication/31414)

- UTE grid-connection / Generación Distribuida regulation portal: [https://www.ute.com.uy/clientes/generacion-distribuida](https://www.ute.com.uy/clientes/generacion-distribuida)

Cert numbers and issuing body (TÜV Rheinland, TÜV SÜD, UL, VDE, JET, Kiwa) must be confirmed against the OEM certificate register at RFQ. Tradvolt does not assert specific certificate numbers on this page.

## 3. CapEx — Capital Cost Breakdown (landed, per Wp and per module)

Inputs below combine module ex-works, ocean freight, insurance, customs, VAT and BoS/BoP typical for an industrial rooftop. Duty and VAT rates are marked **PENDING — lookup** and must be confirmed against the official portals named in §6. The scenario uses a total installed CapEx of USD 175,000 for the 500 kWp reference (= USD 0.35/Wp, within the §3.1 illustrative low–high band).

| Line item | Basis | Unit | Value (illustrative) | Source / note |
| --- | --- | --- | --- | --- |
| Module ex-works (FOB CN) | Tier-1 CN OEM price index | USD / Wp | 0.10 – 0.18 | BloombergNEF PV module spot index: https://about.bnef.com/product/spot-price-indexes/ · InfoLink Consulting PV spot price index: https://www.infolink-group.com/energy/solar-price.html |
| Ocean freight CN→UYMVD | 40' HC container | USD / Wp | 0.01 – 0.03 | Drewry World Container Index weekly: https://www.drewry.co.uk/supply-chain-advisors/supply-chain-expertise/world-container-index-assessed-by-drewry/ · Shanghai Containerized Freight Index (SCFI) weekly: http://en.sse.net.cn/indices/scfi.do?method=index |
| Marine insurance | ~0.3% of CIF | USD / Wp | ~0.0005 | Institute Cargo Clauses (LMA/JCC) wording: https://www.lmalloyds.com/LMA/Underwriting/Marine/Institute-Cargo-Clauses.aspx (rate applied is a model assumption; quote at RFQ) |
| Import duty (UY) | Ad valorem on CIF | % | PENDING — lookup | DNA arancelario en línea: https://www.aduanas.gub.uy/innovaportal/v/13556/1/innova.front/arancelario-en-linea.html |
| VAT (IVA) | On duty-inclusive value | % | PENDING — lookup | DGI — Dirección General Impositiva: https://www.dgi.gub.uy/wdgi/page?2,principal,dgi,sistemaTributario,O,es,0,PAG;CONC;1;D;tasas-y-precios;1;PAG; |
| Despachante / broker fees | Flat per shipment | USD / shipment | 200 – 600 | Cámara de Despachantes de Aduana del Uruguay: https://www.cdauruguay.com.uy/ (model assumption; confirm per agent) |
| Last-mile delivery (Montevideo) | Per Wp | USD / Wp | 0.005 – 0.015 | Local road freight benchmark (model assumption pending quote) |
| Mounting structure (industrial roof) | Aluminium + stainless fixings | USD / Wp | 0.05 – 0.09 | Schletter industrial-rooftop catalogue: https://www.schletter-group.com/en/products/rooftop-systems/ · K2 Systems commercial roof: https://k2-systems.com/en/roof-systems/commercial-rooftop-systems · RBI Solar: https://www.rbisolar.com/commercial-industrial/ |
| DC cabling, connectors, surge protection | BoS electrical | USD / Wp | 0.02 – 0.04 | Stäubli MC4 / MC4-Evo 2 product page: https://www.staubli.com/en/electrical-connectors/photovoltaic/mc4-connectors.html · nVent ERIFLEX catalogue: https://www.nvent.com/en-us/catalog/electrical-and-fastening-solutions |
| Inverter + AC BoS | String inverter 50–110 kW | USD / Wp | 0.05 – 0.10 | Sungrow SG string inverter family: https://en.sungrowpower.com/product/string-inverter · Huawei SUN2000 commercial: https://solar.huawei.com/en/products/Smart-PV-Controller/SUN2000 · SINENG string inverter product list: https://www.sineng.com/product.html |
| EPC margin + engineering | Design, install, commissioning | USD / Wp | 0.05 – 0.10 | Local EPC quote (model assumption pending RFQ) |
| Grid-connection study + UTE fees | Per project | USD / Wp | 0.01 – 0.03 | UTE Generación Distribuida: https://www.ute.com.uy/clientes/generacion-distribuida |

### 3.1 CapEx roll-up — per Wp (illustrative band)

| Bucket | Low (USD/Wp) | High (USD/Wp) |
| --- | --- | --- |
| Module landed (ex-works + freight + ins. + duty + VAT, where applicable) | 0.14 | 0.26 |
| BoS + BoP + EPC + grid | 0.13 | 0.26 |
| **Total installed CapEx (illustrative)** | **0.27** | **0.52** |

Rows sum is an arithmetic check; total is illustrative. Duty / VAT cells are PENDING — see §6. scenario uses USD 0.35/Wp × 500 kWp = USD 175,000 (within band).

## 4. OpEx — Annual Operating Cost (model assumption)

| Line | Unit | Value (illustrative) | Source / note |
| --- | --- | --- | --- |
| Routine O&M (cleaning, inspection) | USD / kWp / yr | 3 – 7 | SolarPower Europe O&M best-practice mid-range: https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power/2024-2028 (model assumption) |
| Inverter replacement reserve (12–15 yr) | USD / kWp / yr | 1 – 3 | Sungrow service: https://en.sungrowpower.com/service · Huawei service: https://solar.huawei.com/en/service (model assumption) |
| Module cleaning (industrial rooftop) | USD / kWp / yr | 1 – 3 | Local service quote (model assumption pending RFQ) |
| Insurance (all-risk) | USD / kWp / yr | 1 – 2 | Mapfre Riesgos Industriales PV policy: https://www.mapfre.com.uy/seguros-para-empresas/ · Sancor Seguros Uruguay: https://www.sancorseguros.com.uy/ (model assumption) |
| Spare parts / unplanned maintenance reserve | USD / kWp / yr | 1 – 3 | Tradvolt internal benchmark (model assumption) |
| **Total OpEx (illustrative)** | USD / kWp / yr | **7 – 18** | Sum of lines (model assumption) |

scenario uses USD 12/kWp/yr × 500 kWp = USD 6,000 in Year 1, escalated at 2.0% per annum (model assumption).

## 5. Energy Yield, Self-Consumption and Payback

Industrial-rooftop sites in Uruguay (Montevideo / Canelones / San José) typically see specific yields in the range **1,400 – 1,700 kWh / kWp / yr** depending on tilt, orientation and shading. Indicative inputs:

| Input | Value (illustrative) | Source / note |
| --- | --- | --- |
| System size | 500 kWp (= ~715 × 700 W modules) | Reference case |
| Specific yield | 1,550 kWh / kWp / yr (Year 1) | PVGIS (JRC) — PVGIS-SARAH2 interactive map, Uruguay: https://re.jrc.ec.europa.eu/pvg_tools/en/#MR |
| Performance ratio (PR) | 0.80 | IEC 61724-1:2021 PV system performance — IEC Webstore: https://webstore.iec.ch/en/publication/65562 |
| Self-consumption share | 70 % | Industrial 2-shift load profile (model assumption) |
| Export to UTE grid | 30 % | UTE Generación Distribuida surplus regime: https://www.ute.com.uy/clientes/generacion-distribuida |
| Avoided import tariff (industrial) | USD / kWh | PENDING — lookup at UTE |
| UTE export tariff | USD / kWh | PENDING — lookup at UTE |
| Annual degradation | 0.5 % / yr linear after Year 1 | Model assumption consistent with TOPCon 1st-year + linear warranty envelope in Jinko Tiger Neo / Trina Vertex N datasheets |

### 5.1 Payback arithmetic (illustrative)

Annual energy (Year 1) = 500 kWp × 1,550 kWh/kWp = **775,000 kWh/yr**.

Self-consumed = 775,000 × 0.70 = **542,500 kWh/yr**. Exported = **232,500 kWh/yr**.

Net annual benefit (placeholder rates used to show the formula — NOT current UTE prices):

- Avoided import at USD 0.13/kWh → 542,500 × 0.13 = **USD 70,525 / yr**

- Export revenue at USD 0.06/kWh → 232,500 × 0.06 = **USD 13,950 / yr**

- Gross annual benefit = **USD 84,475 / yr**

- Annual OpEx (Year 1) = 500 kWp × USD 12/kWp = **USD 6,000 / yr**

- Net annual cash flow (Year 1) = **USD 78,475 / yr**

Total CapEx at USD 0.35/Wp × 500 kWp × 1,000 = **USD 175,000**.

**Simple payback = USD 175,000 ÷ USD 78,475/yr ≈ 2.21 years**. The scenario model returns the same figure to two decimals and a discounted payback of ≈ 2.53 yr at an 8.00% discount rate over 25 years.

### 5.2 Sensitivity table

| Sensitivity to | −20 % | Base | +20 % | Effect on payback |
| --- | --- | --- | --- | --- |
| Specific yield (kWh/kWp) | 1,240 | 1,550 | 1,860 | ±~33 % change in payback |
| Self-consumption share | 56 % | 70 % | 84 % | Shifts payback ±~25 % |
| CapEx (USD/Wp) | 0.28 | 0.35 | 0.42 | Linear: 0.28→1.78 yr; 0.42→2.68 yr |
| Avoided import tariff (USD/kWh) | 0.104 | 0.130 | 0.156 | ±~20 % change in payback |

Sensitivity outputs are arithmetic-only. Rates and yields are placeholders; final values require a live UTE lookup and OEM RFQ. **ILLUSTRATIVE — NOT A QUOTE.**

## 6. Uruguay Duty & VAT Stack

**HS national line | Program | As-of: 2026-09-21 | SoT: PENDING**
Header fields are placeholders to be confirmed at RFQ against the official portals named below.

| Field | Value | Official portal |
| --- | --- | --- |
| HS national line (UY) | PENDING — lookup (PV modules typically under HS 8541.xx; confirm 6/8-digit line) | DNA arancelario en línea: https://www.aduanas.gub.uy/innovaportal/v/13556/1/innova.front/arancelario-en-linea.html |
| Import duty (ad valorem) | PENDING — lookup | DNA arancelario en línea: https://www.aduanas.gub.uy/innovaportal/v/13556/1/innova.front/arancelario-en-linea.html |
| IVA (VAT) rate | PENDING — lookup | DGI — Tasas y precios: https://www.dgi.gub.uy/wdgi/page?2,principal,dgi,sistemaTributario,O,es,0,PAG;CONC;1;D;tasas-y-precios;1;PAG; |
| Trade-agreement preference | PENDING — lookup (e.g. MERCOSUR, China bilateral, or none) | MERCOSUR — Tratado de Asunción (DNA reference page): https://www.aduanas.gub.uy/innovaportal/v/13556/1/innova.front/arancelario-en-linea.html |
| UTE grid code / certificado de conexión | PENDING — lookup | UTE — Generación Distribuida / Reglamento: https://www.ute.com.uy/clientes/generacion-distribuida |

## 7. TCO Outputs (computed, USD)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 367,181.80 |
| Total discounted cost / PV of costs (USD) | 251,044.21 |
| Total undiscounted benefit (USD) | 2,536,380.69 |
| Total discounted benefit (USD) | 1,023,376.62 |
| NPV (USD) | 772,332.41 |
| IRR | 0.4629 |
| Simple payback (year) | 2.21 |
| Discounted payback (year) | 2.53 |
| LCOE (USD/kWh) | 0.0316 |

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 175,000.00 | 0.0000 | -175,000.00 | 1.00 | -175,000.00 | 0.0000 |
| 1 | 6,000.00 | 84,475.00 | 78,475.00 | 0.9259 | 72,662.04 | 775,000.00 |
| 2 | 6,120.00 | 85,733.68 | 79,613.68 | 0.8573 | 68,255.90 | 771,125.00 |
| 3 | 6,242.40 | 87,011.11 | 80,768.71 | 0.7938 | 64,116.81 | 767,269.38 |
| 4 | 6,367.25 | 88,307.57 | 81,940.33 | 0.7350 | 60,228.59 | 763,433.03 |
| 5 | 6,494.59 | 89,623.36 | 83,128.76 | 0.6806 | 56,576.04 | 759,615.86 |
| 6 | 6,624.48 | 90,958.75 | 84,334.26 | 0.6302 | 53,144.89 | 755,817.78 |
| 7 | 6,756.97 | 92,314.03 | 85,557.06 | 0.5835 | 49,921.72 | 752,038.69 |
| 8 | 6,892.11 | 93,689.51 | 86,797.40 | 0.5403 | 46,893.93 | 748,278.50 |
| 9 | 7,029.96 | 95,085.48 | 88,055.53 | 0.5002 | 44,049.69 | 744,537.11 |
| 10 | 7,170.56 | 96,502.26 | 89,331.70 | 0.4632 | 41,377.86 | 740,814.42 |
| 11 | 7,313.97 | 97,940.14 | 90,626.17 | 0.4289 | 38,868.01 | 737,110.35 |
| 12 | 7,460.25 | 99,399.45 | 91,939.20 | 0.3971 | 36,510.32 | 733,424.80 |
| 13 | 7,609.45 | 100,880.50 | 93,271.05 | 0.3677 | 34,295.57 | 729,757.68 |
| 14 | 7,761.64 | 102,383.62 | 94,621.98 | 0.3405 | 32,215.10 | 726,108.89 |
| 15 | 7,916.87 | 103,909.14 | 95,992.26 | 0.3152 | 30,260.76 | 722,478.34 |
| 16 | 8,075.21 | 105,457.38 | 97,382.17 | 0.2919 | 28,424.93 | 718,865.95 |
| 17 | 8,236.71 | 107,028.70 | 98,791.98 | 0.2703 | 26,700.41 | 715,271.62 |
| 18 | 8,401.45 | 108,623.43 | 100,221.98 | 0.2502 | 25,080.45 | 711,695.26 |
| 19 | 8,569.48 | 110,241.91 | 101,672.44 | 0.2317 | 23,558.73 | 708,136.79 |
| 20 | 8,740.87 | 111,884.52 | 103,143.65 | 0.2145 | 22,129.29 | 704,596.10 |
| 21 | 8,915.68 | 113,551.60 | 104,635.91 | 0.1987 | 20,786.53 | 701,073.12 |
| 22 | 9,094.00 | 115,243.52 | 106,149.52 | 0.1839 | 19,525.20 | 697,567.76 |
| 23 | 9,275.88 | 116,960.65 | 107,684.77 | 0.1703 | 18,340.36 | 694,079.92 |
| 24 | 9,461.40 | 118,703.36 | 109,241.96 | 0.1577 | 17,227.39 | 690,609.52 |
| 25 | 9,650.62 | 120,472.04 | 110,821.42 | 0.1460 | 16,181.91 | 687,156.47 |

## 7.1 Model Assumptions (explicit bounded defaults)

| Assumption | Value used | Class |
| --- | --- | --- |
| residual_value.amount | DROPPED-ITEM (residual value excluded from cost stream) | Model assumption |
| residual_value.year | Not applied (see residual_value.amount) | Model assumption |
| replacements[0].amount | DROPPED-ITEM (no mid-life inverter/BoS replacement reserve booked as a discrete replacement capex line; covered inside the OpEx reserve) | Model assumption |
| asset.pv.tariff_escalation_pct | 1.5% per annum on avoided-import tariff; 0% on UTE export tariff (placeholder; both pending UTE lookup) | Model assumption |
| Discount rate | 8.00% / yr | Model assumption (Tradvolt default for industrial B2B) |
| OpEx escalation | 2.0% per annum | Model assumption |
| Module degradation | 0.5% per annum linear after Year 1 | Model assumption |

## 8. Request a Quote

Tell us what you need. We reply within 48 hours with a binding landed-cost offer for the 700 W module on this use-case. The spec & datasheet bundle is delivered via the RFQ site path, not by email.

## 9. Sources

1. BloombergNEF — PV Module Spot Price Index: [https://about.bnef.com/product/spot-price-indexes/](https://about.bnef.com/product/spot-price-indexes/)

2. InfoLink Consulting — Solar PV Spot Price Index: [https://www.infolink-group.com/energy/solar-price.html](https://www.infolink-group.com/energy/solar-price.html)

3. JRC (European Commission) — PVGIS-SARAH2 interactive PV map: [https://re.jrc.ec.europa.eu/pvg_tools/en/#MR](https://re.jrc.ec.europa.eu/pvg_tools/en/#MR)

4. IEC Webstore — IEC 61215-1:2021 publication page: [https://webstore.iec.ch/en/publication/61350](https://webstore.iec.ch/en/publication/61350)

5. IEC Webstore — IEC 61730-1:2016 publication page: [https://webstore.iec.ch/en/publication/26170](https://webstore.iec.ch/en/publication/26170)

6. IEC Webstore — IEC 61701:2020 publication page: [https://webstore.iec.ch/en/publication/31414](https://webstore.iec.ch/en/publication/31414)

7. IEC Webstore — IEC 61724-1:2021 publication page: [https://webstore.iec.ch/en/publication/65562](https://webstore.iec.ch/en/publication/65562)

8. UTE — Generación Distribuida portal: [https://www.ute.com.uy/clientes/generacion-distribuida](https://www.ute.com.uy/clientes/generacion-distribuida)

9. DNA (Dirección Nacional de Aduanas) — Arancelario en línea: [https://www.aduanas.gub.uy/innovaportal/v/13556/1/innova.front/arancelario-en-linea.html](https://www.aduanas.gub.uy/innovaportal/v/13556/1/innova.front/arancelario-en-linea.html)

10. DGI (Dirección General Impositiva) — Tasas y precios: [https://www.dgi.gub.uy/wdgi/page?2,principal,dgi,sistemaTributario,O,es,0,PAG;CONC;1;D;tasas-y-precios;1;PAG;](https://www.dgi.gub.uy/wdgi/page?2,principal,dgi,sistemaTributario,O,es,0,PAG;CONC;1;D;tasas-y-precios;1;PAG;)

11. Drewry — World Container Index: [https://www.drewry.co.uk/supply-chain-advisors/supply-chain-expertise/world-container-index-assessed-by-drewry/](https://www.drewry.co.uk/supply-chain-advisors/supply-chain-expertise/world-container-index-assessed-by-drewry/)

12. Shanghai Containerized Freight Index (SCFI): [http://en.sse.net.cn/indices/scfi.do?method=index](http://en.sse.net.cn/indices/scfi.do?method=index)

13. Jinko Solar — Tiger Neo 3.0 datasheet: [https://www.jinkosolar.com/uploads/2024/Tiger-Neo-3-0-Datasheet.pdf](https://www.jinkosolar.com/uploads/2024/Tiger-Neo-3-0-Datasheet.pdf)

14. Trina Solar — Vertex N datasheet: [https://www.trinasolar.com/sites/default/files/2024-04/DA08_UM_EN_2024_A.pdf](https://www.trinasolar.com/sites/default/files/2024-04/DA08_UM_EN_2024_A.pdf)

15. LONGi — Modules product family: [https://www.longi.com/en/products/modules/](https://www.longi.com/en/products/modules/)

16. Sungrow — String inverter product family: [https://en.sungrowpower.com/product/string-inverter](https://en.sungrowpower.com/product/string-inverter)

17. Huawei Smart PV — SUN2000 controller family: [https://solar.huawei.com/en/products/Smart-PV-Controller/SUN2000](https://solar.huawei.com/en/products/Smart-PV-Controller/SUN2000)

18. SINENG — String inverter product list: [https://www.sineng.com/product.html](https://www.sineng.com/product.html)

19. Stäubli — MC4 / MC4-Evo 2 PV connectors: [https://www.staubli.com/en/electrical-connectors/photovoltaic/mc4-connectors.html](https://www.staubli.com/en/electrical-connectors/photovoltaic/mc4-connectors.html)

20. nVent — ERIFLEX electrical and fastening solutions: [https://www.nvent.com/en-us/catalog/electrical-and-fastening-solutions](https://www.nvent.com/en-us/catalog/electrical-and-fastening-solutions)

21. Schletter — Industrial rooftop systems: [https://www.schletter-group.com/en/products/rooftop-systems/](https://www.schletter-group.com/en/products/rooftop-systems/)

22. K2 Systems — Commercial rooftop systems: [https://k2-systems.com/en/roof-systems/commercial-rooftop-systems](https://k2-systems.com/en/roof-systems/commercial-rooftop-systems)

23. RBI Solar — Commercial & industrial: [https://www.rbisolar.com/commercial-industrial/](https://www.rbisolar.com/commercial-industrial/)

24. SolarPower Europe — Global Market Outlook for Solar Power 2024–2028: [https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power/2024-2028](https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power/2024-2028)

25. LMA — Institute Cargo Clauses: [https://www.lmalloyds.com/LMA/Underwriting/Marine/Institute-Cargo-Clauses.aspx](https://www.lmalloyds.com/LMA/Underwriting/Marine/Institute-Cargo-Clauses.aspx)

26. Mapfre Uruguay — Seguros para empresas: [https://www.mapfre.com.uy/seguros-para-empresas/](https://www.mapfre.com.uy/seguros-para-empresas/)

27. Sancor Seguros Uruguay: [https://www.sancorseguros.com.uy/](https://www.sancorseguros.com.uy/)

## 10. Frequently Asked Questions

### Q1. What is the scenario TCO result for a 700 W industrial-rooftop system in Montevideo?

For the modelled 500 kWp reference case the computed outputs (25-year horizon, 8.00% discount, USD) are: NPV 772,332.41; IRR 0.4629; simple payback 2.21 yr; discounted payback 2.53 yr; LCOE 0.0316 USD/kWh. Year-by-year cash flow is in §7.

### Q2. What HS code applies to 700 W solar panels imported into Uruguay?

Photovoltaic cells and modules are commonly classified under HS heading 8541. The exact 6- or 8-digit national line must be confirmed against the DNA arancelario en línea (see §6).

### Q3. Do 700 W modules need IEC certification for Uruguay?

UTE typically requires IEC 61215 and IEC 61730 evidence for grid-connected PV equipment, with IEC 61701 recommended for coastal sites. Confirm the accepted list and certificate numbers with UTE at the time of procurement.

### Q4. How is payback calculated in the illustrative model?

Payback (years) = Total CapEx ÷ annual net cash flow. Annual net cash flow = (Energy yield × self-consumption share × avoided import price) + (Energy yield × export share × feed-in price) − annual OpEx. All inputs are listed in §5 and labelled ILLUSTRATIVE — NOT A QUOTE.

### Q5. Can Tradvolt issue a binding quote for Uruguay delivery?

Not from this page. TCO briefs are orientation only. A binding landed cost requires a live RFQ with quantity, incoterm, destination, cert list and current freight / duty / VAT lookups. Use §8.

### Q6. What documents are required for CN → UY customs clearance?

Commercial invoice, packing list, bill of lading or AWB, certificate of origin, IEC 61215 and IEC 61730 test certificates, datasheet, and any importer-specific requirements (e.g. UTE grid-approval letter). Confirm the current set with your *despachante de aduanas*.