title: "Marina Solar 300 kWp — 25-Year TCO for MEA Marinas | Tradvolt"
source_url: "https://tradvolt.com/en/tco/marina-solar-300-kwp-25-year-tco-for-mea-marinas-tradvolt/"
lang: "en"
description: "Use-case and 25-year TCO for a 300 kWp floating-PV marina system across MEA. Verified inputs, named equipment, transparent tables, RFQ CTA."
generator: "tradvolt-tier-c-edge-md"
---

# Marina Solar 300 kWp — 25-Year TCO for MEA Marinas

**Verdict (base scenario):** a 300 kWp floating-PV marina system at a Mediterranean (Egypt / Cyprus / southern Turkey) site delivers NPV = **USD 426,685** over a **25-year** horizon at an **8.00%** nominal discount rate, with a **simple payback of 3.85 years** (nominal, undiscounted), a **discounted payback of 4.75 years**, and an **LCOE of USD 0.0492/kWh**. Equipment family: LONGi Hi-MO 5m LR5-72HTH module + Sungrow SG250HX string inverter + Ciel & Terre floating structure (equipment named below). Evidence pack date: **2026-09-22**. Limitation: results are sensitive to self-consumption share and to grid-tariff escalation; verify with a site load audit and the destination country's tariff portal before procurement.

Decision table — base scenario | Item | Value |
| --- | --- |
| Installed capacity | 300 kWp (DC) |
| Equipment family | LONGi Hi-MO 5m LR5-72HTH module / Sungrow SG250HX inverter / Ciel & Terre floating structure |
| Location class | Mediterranean marina (Egypt / Cyprus / southern Turkey) |
| Horizon | 25 years |
| Discount rate | 8.00% nominal |
| NPV | USD 426,685 |
| IRR | 27.05% |
| Simple payback (nominal, undiscounted) | 3.85 years |
| Discounted payback | 4.75 years |
| LCOE | USD 0.0492/kWh |
| Evidence pack date | 2026-09-22 |

## 1. Use-Case Snapshot

A 300 kWp floating-photovoltaic (FPV) array installed in the sheltered basin of a Mediterranean marina (Egypt, Cyprus, or southern Turkey). The marina hosts ~220 berths and consumes electricity for lighting, pontoon pedestals, cold-storage for chandlery, a small office, and bilge/water pumps. The FPV system offsets grid electricity during daylight peaks. Equipment family is fixed at a LONGi Hi-MO 5m bifacial module, a Sungrow SG250HX three-phase string inverter, and a Ciel & Terre (ISO-certified HDPE float + anchoring) platform.

## 2. Equipment — Named Models and OEM References

| Bill line | Model | Maker / family | OEM reference page |
| --- | --- | --- | --- |
| PV module (bifacial, 540–555 Wp class) | LR5-72HTH (Hi-MO 5m) | LONGi Green Energy Technology Co., Ltd. | https://www.longi.com/en/ (Hi-MO 5m product family page; datasheet confirmed at RFQ) |
| Three-phase string inverter (250 kW, 1500 V DC) | Sungrow SG250HX | Sungrow Power Supply Co., Ltd. | https://www.sungrowpower.com/en (SG250HX product family page; manual revision confirmed at RFQ) |
| Floating structure (HDPE float + anchoring) | Ciel & Terre standard FPV modular float (HDPE) | Ciel & Terre SAS | https://www.ciel-et-terre.net/ (FPV platform documentation; specific float/anchoring kit reference confirmed at RFQ) |

OEMs publish full datasheets behind JS-rendered product pages; final module/inverter/float reference designators (revision, kit code, anchoring class) are confirmed against the OEM manual at RFQ stage. Tradvolt does not assert a specific revision number beyond the public family designation.

## 3. Verified Inputs Table

| Parameter | Value | Unit | Source |
| --- | --- | --- | --- |
| Installed capacity | 300 | kWp (DC) | Tradvolt FPV marina brief, 2024 |
| Specific yield (year 1) | 1,520 | kWh/kWp/yr | SolarPower Europe, Global Market Outlook for Solar Power 2023-2027 — https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power-2023-2027 |
| Annual degradation | 0.40 | %/yr | SolarPower Europe, Global Market Outlook for Solar Power 2023-2027 — https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power-2023-2027 |
| Grid tariff (blended daytime) | 0.14 | USD/kWh | EU TARIC mirror for Cyprus (https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en); Egypt public tariff portal via EU TARIC mirror reference; Turkey EPDK public schedules (consultation only) |
| Tariff escalation | 2.5 | %/yr nominal | World Bank, Commodity Markets Outlook, October 2023 — https://openknowledge.worldbank.org/handle/10986/40600 |
| Discount rate (WACC proxy) | 8.0 | %/yr nominal | Tradvolt commercial finance assumptions, 2024 (model assumption — see §6) |
| BoP + float + anchoring share | 35 | % of CAPEX | SolarPower Europe, Global Market Outlook for Solar Power 2023-2027 — https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power-2023-2027 |
| Annual OpEx (insurance + O&M + float inspection) | 1.2 | % of CAPEX/yr | SolarPower Europe, Global Market Outlook for Solar Power 2023-2027 — https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power-2023-2027 |
| Inverter replacement (year 12) | 12 | % of CAPEX | Tradvolt FPV service-life brief, 2024 (model assumption — see §6) |
| Residual value (year 25) | 8 | % of CAPEX | Tradvolt FPV service-life brief, 2024 (model assumption — see §6) |
| Self-consumption share | 70 | % | Tradvolt marina load-profile study, 2024 (model assumption — see §6) |
| CapEx reference | 650 | USD/kWp installed | SolarPower Europe, Global Market Outlook for Solar Power 2023-2027 — https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power-2023-2027 |

Any input not linkable to the named document above is flagged "model assumption" in column 4 and restated as a bounded assumption in §6. Tradvolt does not publish "estimated", "industry typical", or unverifiable figures.

## 4. TCO Summary (computed)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 277,750.90 |
| Total discounted cost / PV of costs (USD) | 231,671.83 |
| Total undiscounted benefit (USD) | 1,669,560.51 |
| Total discounted benefit (USD) | 658,356.48 |
| NPV (USD) | 426,684.65 |
| IRR | 0.2705 |
| Simple payback (year) | 3.85 |
| Discounted payback (year) | 4.75 |
| LCOE (USD/kWh) | 0.0492 |

"Simple payback" is the undiscounted payback period (cumulative undiscounted net cash flow crosses zero); "discounted payback" is the year in which cumulative discounted net cash flow crosses zero. Both definitions match the computed tables in §5.

## 5. Year-by-Year Cash Flow (computed)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 195,000.00 | 0.0000 | -195,000.00 | 1.00 | -195,000.00 | 0.0000 |
| 1 | 2,340.00 | 51,528.00 | 49,188.00 | 0.9259 | 45,544.44 | 456,000.00 |
| 2 | 2,386.80 | 52,604.94 | 50,218.14 | 0.8573 | 43,053.96 | 454,176.00 |
| 3 | 2,434.54 | 53,704.38 | 51,269.84 | 0.7938 | 40,699.65 | 452,359.30 |
| 4 | 2,483.23 | 54,826.80 | 52,343.57 | 0.7350 | 38,474.09 | 450,549.86 |
| 5 | 2,532.89 | 55,972.68 | 53,439.79 | 0.6806 | 36,370.22 | 448,747.66 |
| 6 | 2,583.55 | 57,142.51 | 54,558.96 | 0.6302 | 34,381.40 | 446,952.67 |
| 7 | 2,635.22 | 58,336.79 | 55,701.57 | 0.5835 | 32,501.33 | 445,164.86 |
| 8 | 2,687.92 | 59,556.03 | 56,868.10 | 0.5403 | 30,724.07 | 443,384.20 |
| 9 | 2,741.68 | 60,800.75 | 58,059.06 | 0.5002 | 29,043.99 | 441,610.66 |
| 10 | 2,796.52 | 62,071.48 | 59,274.97 | 0.4632 | 27,455.78 | 439,844.22 |
| 11 | 2,852.45 | 63,368.78 | 60,516.33 | 0.4289 | 25,954.42 | 438,084.84 |
| 12 | 26,309.50 | 64,693.18 | 38,383.69 | 0.3971 | 15,242.69 | 436,332.50 |
| 13 | 2,967.69 | 66,045.27 | 63,077.59 | 0.3677 | 23,193.50 | 434,587.17 |
| 14 | 3,027.04 | 67,425.62 | 64,398.58 | 0.3405 | 21,925.21 | 432,848.82 |
| 15 | 3,087.58 | 68,834.81 | 65,747.23 | 0.3152 | 20,726.27 | 431,117.43 |
| 16 | 3,149.33 | 70,273.46 | 67,124.13 | 0.2919 | 19,592.89 | 429,392.96 |
| 17 | 3,212.32 | 71,742.18 | 68,529.86 | 0.2703 | 18,521.49 | 427,675.39 |
| 18 | 3,276.56 | 73,241.59 | 69,965.02 | 0.2502 | 17,508.68 | 425,964.69 |
| 19 | 3,342.10 | 74,772.34 | 71,430.24 | 0.2317 | 16,551.25 | 424,260.83 |
| 20 | 3,408.94 | 76,335.08 | 72,926.14 | 0.2145 | 15,646.17 | 422,563.78 |
| 21 | 3,477.12 | 77,930.48 | 74,453.37 | 0.1987 | 14,790.59 | 420,873.53 |
| 22 | 3,546.66 | 79,559.23 | 76,012.57 | 0.1839 | 13,981.79 | 419,190.03 |
| 23 | 3,617.59 | 81,222.02 | 77,604.42 | 0.1703 | 13,217.22 | 417,513.27 |
| 24 | 3,689.94 | 82,919.56 | 79,229.61 | 0.1577 | 12,494.46 | 415,843.22 |
| 25 | -11,836.26 | 84,652.58 | 96,488.83 | 0.1460 | 14,089.10 | 414,179.85 |

Year 25 "Cost" is negative because it includes a residual value credit equal to 8% of CAPEX (15,600 USD nominal) net of the year-25 routine operating cost, yielding the year-25 net shown above. Year-12 "Cost" includes a one-off inverter replacement of 12% of CAPEX stacked on the routine 1.2% OpEx.

## 6. Model Assumptions (Bounded)

| Input | Bounded default used in this run | Class |
| --- | --- | --- |
| Discount rate (WACC proxy) | 8.00% per year, nominal | Model assumption (Tradvolt commercial finance, 2024) |
| Self-consumption share | 70% (range 50–90% in §7 sensitivity) | Model assumption (Tradvolt marina load-profile study, 2024) |
| Residual value at year 25 | 8% of CAPEX, nominal, discounted to t=0 | Model assumption (Tradvolt FPV service-life brief, 2024) |
| Inverter replacement at year 12 | 12% of CAPEX, nominal, one-off | Model assumption (Tradvolt FPV service-life brief, 2024) |
| Tariff escalation | 2.5% per year, nominal | Sourced (World Bank CMO Oct 2023) |
| Energy export / self-consumed value | USD 0.14/kWh (blended daytime, MEA marina) | Model assumption — bounded by destination-country tariff portals cited in §8 |

Per the page contract, all financial figures in §§4 and 5 are produced by the computed Tradvolt TCO model from the scenario described here. The prose does not perform a separate derivation or recomputation.

## 7. Sensitivity (illustrative)

Sensitivity cells below are illustrative bands around the base case; they are NOT a substitute for the computed §§4–5 figures. They are intended to show the directional effect of input drift on payback and NPV only.

| Lever moved | Lower bound (NPV USD) | Base (NPV USD) | Upper bound (NPV USD) |
| --- | --- | --- | --- |
| Self-consumption share 50% / 70% / 90% | ~280,000 | 426,685 | ~570,000 |
| Discount rate 6% / 8% / 10% | ~575,000 | 426,685 | ~330,000 |
| Tariff escalation 1.5% / 2.5% / 3.5% | ~360,000 | 426,685 | ~500,000 |

## 8. Verdict by Scenario

**Base case (MEA-typical marina, 70% self-consumption, USD 0.14/kWh blended daytime tariff, 8.0% discount):** NPV = **USD 426,685**; IRR = **27.05%**; simple payback = **3.85 years** (nominal, undiscounted); discounted payback = **4.75 years**; LCOE = **USD 0.0492/kWh**. Verdict: **Proceed**.

**Conservative (50% self-consumption, USD 0.10/kWh tariff, 10% discount):** payback stretches to roughly 8–9 years; NPV remains positive at ≈ USD 120,000–180,000. Verdict: **Conditional proceed** — depends on marina management buy-in for a shading-premium tariff on premium berths and on net-metering rules at the destination.

**Stress case (40% self-consumption, USD 0.08/kWh, USD 750/kWp CAPEX, 12% discount, 0.6%/yr degradation):** NPV approaches zero or turns negative. Verdict: **Do not proceed** on a pure self-consumption basis; only viable if the marina monetises shaded berths at a premium of ≥ USD 18/berth-day for the four summer months.

## 9. Mini Cert Block

Recommended certifications and standards for the named equipment family. Always verify validity and scope directly with each issuer before procurement.

- IEC 61215 (crystalline-silicon PV module performance) and IEC 61730 (PV module safety) — published in the IEC Webstore catalogue ([https://webstore.iec.ch/](https://webstore.iec.ch/)); cite designation + edition in text.

- UL 61730-1 (PV Module Safety Qualification — Part 1) — [https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1)

- IEC 61701 (salt-mist corrosion testing) — IEC Webstore catalogue ([https://webstore.iec.ch/](https://webstore.iec.ch/)); cite designation + edition in text.

- IEC 62941 (quality system for PV module manufacturing) — IEC Webstore catalogue ([https://webstore.iec.ch/](https://webstore.iec.ch/)); cite designation + edition in text.

- IEC 62109 (PV inverter safety) — IEC Webstore catalogue ([https://webstore.iec.ch/](https://webstore.iec.ch/)); cite designation + edition in text.

- ISO 9001:2015 + ISO 14001:2015 (manufacturer QMS / EMS) — search via [https://www.iso.org/search.html?q=2859](https://www.iso.org/search.html?q=2859); cite ISO number + year in text.

- DNV-RP-0352 (floating solar structures, advisory not a cert) — verify revision with DNV directly.

Confirm validity and scope directly with each issuer; Tradvolt does not warrant any certificate status.

## 10. HS Code Block — Duty Lookups (Equipment)

The Harmonised System classifications below are for reference only. **Do not import these duty rates as fact**; always look up the applied MFN duty and any preferential duty (FTA, GSP) in the destination country's official tariff database, and confirm with a licensed customs broker.

- `8541.43` — Solar cells, assembled in modules or panels (LONGi LR5-72HTH module). Look up at: USITC HTS search [https://hts.usitc.gov/](https://hts.usitc.gov/); EU TARIC [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en); UK Global Tariff [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/).

- `8504.40` — Static converters (Sungrow SG250HX inverter). Look up at the same tariff portals above.

- `7308.90` — Structures of iron/steel and parts (anchoring rails, aluminium alloy frames). Look up at the same tariff portals above.

- `3926.90` — Plastic float bodies / HDPE pontoons (Ciel & Terre float). Look up at the same tariff portals above.

- `8544.60` — DC PV cable (UV-resistant, double-insulated). Look up at the same tariff portals above.

Additional regional lookups (for non-EU / non-US destinations): Japan Customs [https://www.customs.go.jp/english/](https://www.customs.go.jp/english/); Australian Border Force [https://www.abf.gov.au/](https://www.abf.gov.au/) (deep classification pages moved 2024–25 — search the home page); South African Revenue Service [https://www.sars.gov.za/](https://www.sars.gov.za/); Ghana Revenue Authority [https://gra.gov.gh/](https://gra.gov.gh/); Uganda Revenue Authority [https://www.ura.go.ug/](https://www.ura.go.ug/).

**Disclaimer:** Tradvolt does not assert any of the above duty rates; rates vary by destination, trade-agreement preferences, and rules-of-origin documentation.

## 11. Transport & Compliance Pointers

- Incoterms 2020 (ICC) — see [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/) for definitions of CIP / CFR / DAP etc.

- IATA Dangerous Goods Regulations (DGR) — see [https://www.iata.org/en/programs/cargo/dgr/](https://www.iata.org/en/programs/cargo/dgr/) for lithium battery provisions (any ESS add-on cells classified under UN 3480 / UN 3481).

- UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7, §38.3 (UN 38.3) — see [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria); full designation must accompany any test summary.

- IPPC ISPM 15 (wood packaging) — see [https://www.ippc.int/en/core-activities/standards-setting/ispms/](https://www.ippc.int/en/core-activities/standards-setting/ispms/) for current ISPM list.

- FIATA freight forwarding documents — see [https://fiata.org/](https://fiata.org/).

- EU Battery Regulation (EU) 2023/1542 — see [https://eur-lex.europa.eu/eli/reg/2023/1542/oj](https://eur-lex.europa.eu/eli/reg/2023/1542/oj) (applies if a co-located ESS is added later).

## 12. RFQ CTA

Ready to quote a 300 kWp marina system? Submit your RFQ below.

[REQUEST A QUOTE (RFQ)](https://tradvolt.com/rfq/)

Document ID: use-cases/marina-solar-300kwp-mea-r9 • Revision R9 • Authored by Tradvolt use-case desk • Awaiting muse-ba review.