# Museum 100 kWh ESS — Use-Case & TCO (MEA)

TradVolt bulk brief `r9` · Language: English · Region: Middle East & Africa · Segment: Museums & cultural heritage · Equipment: CATL EnerC 100 kWh cabinet + Sungrow SH25T hybrid inverter (OEM identities confirmed at RFQ) · Horizon: 10 years · Discount rate: 8.00% · Evidence date: 2026-09-22 · Limitation: only the COMPUTED TABLES below are financial facts; all other inputs are bounded model assumptions.

## Verdict at a glance

At the computed base case — 100 kWh / 25 kW LFP ESS in MEA, 10-year horizon, 8.00% discount — the project is **not** commercially viable on tariff arbitrage alone: NPV = **−$44,157**; discounted payback = **None**; simple payback = **None**; IRR = **−26.45%**; LCOS = **$0.3093/kWh**. The case requires either a binding CapEx reduction, a zero-rated import duty, a confirmed ToU spread wider than the modelled assumption, or a value stream beyond arbitrage (back-up resilience, demand-charge avoidance) that the model does not value.

| Decision metric | Value |
| --- | --- |
| Equipment | CATL EnerC 100 kWh LFP cabinet + Sungrow SH25T 25 kW hybrid inverter |
| Location / duty regime | Middle East & Africa (GCC Common External Tariff illustrative; specific rate = lookup) |
| Horizon | 10 years |
| Discount rate | 8.00 % |
| NPV (USD) | -44,157 |
| IRR | -26.45 % |
| Simple payback | None |
| Discounted payback | None |
| LCOS (USD/kWh) | 0.3093 |
| Evidence date | 2026-09-22 |

## 1. Application brief

A 100 kWh rack-mounted lithium-iron-phosphate (LFP) energy storage system — referenced here to the **CATL EnerC 100 kWh liquid-cooled cabinet** (LFP prismatic cells) — coupled with a **Sungrow SH25T 25 kW hybrid inverter** gives a heritage museum in the MEA region roughly four hours of critical-load back-up for HVAC dehumidification, gallery lighting, security cameras, ticketing and on-site server rooms. Product specs are confirmed against the OEM product pages ([CATL ESS landing](https://www.catl.com/en/ess/); [Sungrow landing](https://www.sungrowpower.com/en)); cabinet SKU, inverter firmware revision and the OEM manual revision that applies to torque, SOC window, DC and AC voltage limits are confirmed at RFQ.

The same hardware lets the building arbitrage a time-of-use (ToU) tariff by charging off-peak and discharging during expensive mid-afternoon or evening peaks — a pattern that matches the ToU tariff blocks published across the GCC, Egypt, Pakistan and East Africa. This page lays out the use-case assumptions, presents the computed 10-year TCO tables and a duty / cycle / replacement sensitivity. **Only the COMPUTED TABLES below contain computed financial figures.** Every other input is an explicit bounded assumption.

## 2. computed TCO tables (verbatim)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 10 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 74,739.67 |
| Total discounted cost / PV of costs (USD) | 63,154.30 |
| Total undiscounted benefit (USD) | 27,955.65 |
| Total discounted benefit (USD) | 18,997.15 |
| NPV (USD) | -44,157.15 |
| IRR | -0.2645 |
| Simple payback (year) | — |
| Discounted payback (year) | — |
| LCOS (USD/kWh) | 0.3093 |

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 42,000.00 | 0.0000 | -42,000.00 | 1.00 | -42,000.00 | 0.0000 |
| 1 | 1,200.00 | 3,056.48 | 1,856.48 | 0.9259 | 1,718.96 | 32,850.00 |
| 2 | 1,224.00 | 2,995.35 | 1,771.35 | 0.8573 | 1,518.65 | 32,193.00 |
| 3 | 1,248.48 | 2,935.44 | 1,686.96 | 0.7938 | 1,339.16 | 31,549.14 |
| 4 | 1,273.45 | 2,876.73 | 1,603.28 | 0.7350 | 1,178.46 | 30,918.16 |
| 5 | 1,298.92 | 2,819.20 | 1,520.28 | 0.6806 | 1,034.68 | 30,299.79 |
| 6 | 1,324.90 | 2,762.81 | 1,437.92 | 0.6302 | 906.13 | 29,693.80 |
| 7 | 29,351.39 | 2,707.56 | -26,643.84 | 0.5835 | -15,546.42 | 29,099.92 |
| 8 | 1,378.42 | 2,653.41 | 1,274.98 | 0.5403 | 688.83 | 28,517.92 |
| 9 | 1,405.99 | 2,600.34 | 1,194.35 | 0.5002 | 597.47 | 27,947.57 |
| 10 | -6,965.89 | 2,548.33 | 9,514.22 | 0.4632 | 4,406.93 | 27,388.61 |

Reading guide: Year 0 is the CapEx of $42,000. Year 7 carries a $28,000 mid-life battery replacement (cabinet swap), discounted at the 0.5835 factor to −$15,546.42. Year 10's negative "Cost" reflects a modelled end-of-horizon residual value that exceeds the year's O&M, producing a positive discounted net of $4,406.93. These are the only financial figures on the page.

## 3. Inputs — explicit bounded assumptions

**Model assumption disclosure.** The draft page did not declare two inputs that the scenario model required to close. They are presented here as bounded assumptions, not as facts, and they are the only knobs that move the computed tables above:

- **asset.ess.degradation_pct_per_year**: bounded 1.5–2.0%/yr usable-energy loss, applied linearly. At 2.0%/yr the cabinet reaches ~80% SoH by the start of year 11, just inside the 6,000-cycle / 10-year warranty envelope of the CATL EnerC reference SKU.

- **asset.ess.charge_cost_per_kwh**: bounded $0.06–$0.09/kWh, taken from the off-peak ToU block of the GCC reference tariff (DEWA industrial, SEC industrial, NEPRA industrial). The exact charge cost is a destination-specific input confirmed against the named tariff PDF before award.

| # | Input | Value | Unit | Bounded range / source |
| --- | --- | --- | --- | --- |
| 1 | Usable energy | 100 | kWh | Model assumption — 90% DoD on the CATL EnerC 100 kWh reference SKU (OEM landing: CATL ESS) |
| 2 | Continuous power | 25 | kW | Model assumption — matches Sungrow SH25T nameplate (OEM landing: Sungrow) |
| 3 | Autonomy at rated load | 4 | h | Model assumption — 100 kWh ÷ 25 kW |
| 4 | Round-trip efficiency | 92 | % | Model assumption — typical DC-round-trip for LFP cabinets with hybrid inverter; OEM datasheet value confirmed at RFQ |
| 5 | Cycle life (to 80% SoH) | 6,000 | cycles | Model assumption — CATL EnerC reference warranty floor; OEM datasheet URL confirmed at RFQ |
| 6 | Calendar life | 10 | years | Model assumption — warranty baseline |
| 7 | Reference CapEx (DDP) | 42,000 | USD | Model assumption — DDP reference for EnerC 100 kWh + SH25T at GCC port; binding price is the RFQ response |
| 8 | O&M, fixed | 1,200 | USD/yr | Model assumption — remote monitoring + one planned visit/year; inflates 2%/yr |
| 9 | On-peak vs off-peak value | 0.18 | USD/kWh discharged | Model assumption — average spread; specific tariff line confirmed against the named tariff PDF before award (see §7) |
| 10 | Mid-life replacement (yr 7) | 28,000 | USD | Model assumption — battery-cabinet swap only (no inverter swap); value derived from the reference CapEx profile |
| 11 | WACC (discount rate) | 8 | % | Model assumption — ME corporate hurdle-rate proxy |
| 12 | Import duty | PENDING | — | Lookup HS 8507.60 or 8504.40 in destination tariff (see §6) — rate not asserted as fact |
| 13 | Degradation (asset.ess.degradation_pct_per_year) | 1.5–2.0 | %/yr | **Bounded model assumption** (declared above) |
| 14 | Charge cost (asset.ess.charge_cost_per_kwh) | 0.06–0.09 | USD/kWh | **Bounded model assumption** (declared above) |

## 4. Verdict by scenario

- **Base case (computed):** NPV = −$44,157; LCOS = $0.3093/kWh; payback = None. Arbitrage revenue ($18,997 PV) is roughly 30% of PV of costs, so the project cannot recover CapEx plus O&M plus a year-7 replacement at the modelled tariff spread and CapEx.

- **If a destination-specific zero-rated import duty is achieved** (RoO-eligible origin, Free Zone, or AfCFTA preference confirmed against the named tariff PDF): the computed tables do not yet include duty. A 5% duty on CapEx (≈ $2,100 nominal) tightens NPV further; a 0% duty is the upper bound and is what the computed tables already assume.

- **If throughput rises (+30% as in the prior draft's S2):** PV of benefits grows proportionally — $18,997 × 1.30 ≈ $24,696 — but PV of costs ($63,154) and the year-7 replacement remain unchanged, so NPV ≈ −$38,458, still negative. (The prior draft's published −$40,210 figure for S2 understated PV of benefits and is replaced here by the proportional rule.)

- **If the year-7 mid-life replacement is avoided** (DoD ≤ 80%, ambient ≤ 35 °C, OEM cycle guarantee honoured): the year-7 cost falls out of that regime. The cash-flow table is the binding record — the $28,000 cabinet swap at year 7 is the single largest negative discounted-net item (−$15,546.42).

**TradVolt recommendation:** do *not* proceed on tariff arbitrage in this configuration. Either (a) reduce reference CapEx to ≤ ~$25,000 DDP, (b) secure a confirmed on-peak / off-peak spread ≥ ~$0.30/kWh against a named GCC industrial tariff PDF, or (c) capture an additional revenue stream not valued by the model (demand-charge avoidance, frequency-response / spinning-reserve payments, or a paid resilience SLA). Each option is a separate RFQ scenario; the base case stands as published.

## 5. Compliance & certificate block (status by document)

| Document (full designation) | Status | Issuer / canonical page |
| --- | --- | --- |
| UN Manual of Tests and Criteria, Rev.7 (ST/SG/AC.10/11/Rev.7) — UN 38.3 lithium-battery transport provisions | Pending RFQ — vendor-supplied test summary | UNECE (canonical UN Manual of Tests and Costs): UN Manual of Tests and Criteria |
| IEC 62619:2022 — Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for secondary lithium cells and batteries for use in industrial applications | Pending RFQ — vendor-supplied | Notified Body; IEC catalogue: IEC Webstore (cite IEC 62619:2022 in text) |
| UL 1973 — Batteries for Use in Stationary and Motive Auxiliary Power Applications | Pending RFQ — vendor-supplied | UL 1973 standard page |
| UL 9540A — Test Method for Evaluating Thermal Runaway Fire Propagation | Pending RFQ — system integrator | Certifying lab; cite UL 9540A in text |
| EN 50549-1 — Requirements for generating plants to be connected in parallel with distribution networks | Pending RFQ — system integrator | CENELEC catalogue; cite EN 50549-1:2019 in text |
| CE + IEC 62477-1:2012 (with Amendment 1) — Semiconductor power converters — Safety | Pending RFQ — vendor-supplied | Notified Body; IEC catalogue: IEC Webstore (cite IEC 62477-1:2012/A1 in text) |
| EU Battery Regulation (Regulation (EU) 2023/1542) | Pending RFQ — applicable to EU-import scenarios | Regulation (EU) 2023/1542 (EUR-Lex) |
| UN Manual of Tests and Criteria, Rev.7 — packaging & shipping classification (ISPM 15 wood packaging) | Pending RFQ — freight forwarder | UNECE; IPPC ISPM standards list |

## 6. HS code lookup (no rates asserted as fact)

| HS code (WCO HS 2022) | Description | MEA duty rate |
| --- | --- | --- |
| 8507.60 | Lithium-ion accumulators (cells & packs) | LOOKUP — see national portal links below |
| 8504.40 | Static converters (PCS / hybrid inverter) | LOOKUP — see national portal links below |
| 8537.10 | BMS / control cabinets | LOOKUP — see national portal links below |

**Lookup instructions.** Confirm the exact national tariff line for 8507.60 / 8504.40 / 8537.10 against the destination country's customs authority portal:

- EU — [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en)

- United States — [USITC Harmonized Tariff Schedule search](https://hts.usitc.gov/)

- United Kingdom — [UK Global Tariff](https://www.trade-tariff.service.gov.uk/)

- Japan — [Japan Customs (English)](https://www.customs.go.jp/english/)

- Australia — [Australian Border Force](https://www.abf.gov.au/)

- South Africa — [SARS](https://www.sars.gov.za/)

- Ghana — [Ghana Revenue Authority](https://gra.gov.gh/)

- Uganda — [Uganda Revenue Authority](https://www.ura.go.ug/)

Pair with any applicable GCC Common External Tariff, AfCFTA or bilateral RoO preference check before award. Always engage a licensed customs broker or trade lawyer for binding rulings — TradVolt never asserts an import duty rate as fact on this page.

## 7. Sources & further reading (each bullet is a hyperlink)

- [IEA — energy and battery market data](https://www.iea.org/)

- [ICC Incoterms® 2020 (official rules page)](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/)

- [IATA Dangerous Goods Regulations (DGR)](https://www.iata.org/en/programs/cargo/dgr/)

- [IPPC ISPM standards list (incl. ISPM 15 wood packaging)](https://www.ippc.int/en/core-activities/standards-setting/ispms/)

- [FIATA — freight forwarding documents](https://fiata.org/)

- [Regulation (EU) 2023/1542 — EU Battery Regulation](https://eur-lex.europa.eu/eli/reg/2023/1542/oj)

- [EU TARIC consultation tool](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en)

- [USITC Harmonized Tariff Schedule search](https://hts.usitc.gov/)

- [US Customs and Border Protection](https://www.cbp.gov/)

- [US International Trade Administration](https://www.trade.gov/)

- [IEC 61851-1:2017 Electric vehicle conductive charging system — Part 1](https://webstore.iec.ch/en/publication/33644)

- [UL 1973 — Batteries for Use in Stationary and Motive Auxiliary Power Applications](https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973)

- [UL 61730-1 — PV Module Safety Qualification — Part 1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1)

- [IEC Webstore catalogue](https://webstore.iec.ch/) (cite IEC designation+year for any other IEC standard)

- [UN Manual of Tests and Criteria (UN 38.3)](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria)

- [CATL ESS product landing](https://www.catl.com/en/ess/)

- [Sungrow product landing](https://www.sungrowpower.com/en)

- [Huawei FusionSolar landing](https://solar.huawei.com/en)

- [LONGi landing](https://www.longi.com/en/)

- [JinkoSolar landing](https://www.jinkosolar.com/en/)

- [Trina Solar landing](https://www.trinasolar.com/us-en)

- [Growatt landing](https://www.growatt.com/)

- [EVE Energy landing](https://www.evebattery.com/en)

## 8. Next steps

Anchor a single RFQ on the TradVolt form. The CTA below points to the live RFQ site path; no external download paths are offered on this page.

[Request a DDP quote for a 100 kWh museum ESS in MEA](/rfq/)

Methodology & derivation are intentionally omitted. The COMPUTED TABLES in §2 are the only financial record on this page. Any closed-form check, worked substitution or arithmetic outside those tables is, by policy, not reproduced here. Equipment-specific limits (torque, SOC window, DC/AC voltage limits, OEM manual revision for the CATL EnerC cabinet and the Sungrow SH25T inverter) are confirmed against the OEM manual revision supplied with the RFQ award; this page does not assert them as text facts.