title: "Office-Tower 50-Port AC EVSE TCO | MEA | Tradvolt"
source_url: "https://tradvolt.com/en/tco/office-tower-50-port-ac-evse-tco-mea-tradvolt/"
lang: "en"
description: "Office tower 50-port AC EVSE TCO for MEA: NPV=-AED 5,070,169 over 10 years; discounted payback=None. Model based on Sungrow/Solis/GoodWe AC chargers and Huawei LUNA2000 reference inputs."
generator: "tradvolt-tier-c-edge-md"
---

# Office-Tower 50-Port AC EVSE TCO — MEA

**Verdict:** NPV = **-AED 5,070,169** over 10 years at 8.00% discount; simple payback = None; discounted payback = None. TCO per km: EV = AED 0.1888 vs ICE = AED 0.3160; savings per km = AED 0.1273; savings over horizon = AED 2,545,000. Horizon: 10 years. Equipment: 50-port AC EVSE array (Sungrow AC011E-01 reference charger, GoodWe HCA-G1 series equivalent). Location: UAE office tower. Evidence date: 2026-09-27. Limitation: 10-year discount horizon; OPEX escalates at 2% p.a.; 80% utilization applied to BOTH energy cost and revenue consistently per R11.

| Decision factor | Value |
| --- | --- |
| NPV (10y, 8.00%) | -AED 5,070,168.95 |
| PV of costs / PV of benefits | AED 5,955,899.70 / AED 885,730.74 |
| Simple payback / Discounted payback | None / None |
| TCO per km (EV vs ICE) | AED 0.1888 vs 0.3160 (savings 0.1273) |
| Equipment basis | Sungrow AC011E-01 AC charger, 50 dual-port units |
| Standards cited | IEC 61851-1:2017, IEC 62196-3 |

## 1. Scope and equipment basis

Scenario: 50 dual-port AC EVSE array serving an office tower in the UAE. Hardware basis: **Sungrow AC011E-01** 11 kW dual-port AC charger (OCPP 1.6J), with equivalent-class fallback options **GoodWe HCA-G1 series** and **Solis S6-EH3P(8-12)K-LV-ND-H** hybrid-inverter-bundled AC outlet reference. Networking and back-office software per OCPP 1.6J (Open Charge Alliance protocol reference: [openchargealliance.org](https://www.openchargealliance.org/)). Standards cited for AC EVSE interoperability: **IEC 61851-1:2017** Electric vehicle conductive charging system — Part 1: General requirements (IEC Webstore publication 33644) and **IEC 62196-3** Plugs, socket-outlets, vehicle connectors and vehicle inlets — Conductive charging of electric vehicles — Part 3: Dimensional compatibility and interchangeability requirements for DC and AC/DC pin and contact-tube vehicle couplers.

## 2. Decision table — headline metrics

TCO summary | Metric | Value |
| --- | --- |
| Currency | AED |
| Horizon (years) | 10 |
| Discount rate | 8.00 % |
| Total undiscounted cost (AED) | 8,593,100.79 |
| Total discounted cost / PV of costs (AED) | 5,955,899.70 |
| Total undiscounted benefit (AED) | 1,320,000.00 |
| Total discounted benefit (AED) | 885,730.74 |
| NPV (AED) | -5,070,168.95 |
| IRR | n/a |
| Simple payback (year) | — |
| Discounted payback (year) | — |
| TCO per km — EV (AED/km) | 0.1888 |
| TCO per km — ICE (AED/km) | 0.3160 |
| Savings per km (AED/km) | 0.1273 |
| Savings over horizon (AED) | 2,545,000.00 |

## 3. Year-by-year cash flow

Year-by-year cash flow | Year | Cost (AED) | Benefit (AED) | Net (AED) | Discount factor | Discounted net (AED) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 775,000.00 | 0.0000 | -775,000.00 | 1.00 | -775,000.00 | 0.0000 |
| 1 | 714,000.00 | 132,000.00 | -582,000.00 | 0.9259 | -538,888.89 | 0.0000 |
| 2 | 728,280.00 | 132,000.00 | -596,280.00 | 0.8573 | -511,213.99 | 0.0000 |
| 3 | 742,845.60 | 132,000.00 | -610,845.60 | 0.7938 | -484,908.93 | 0.0000 |
| 4 | 757,702.51 | 132,000.00 | -625,702.51 | 0.7350 | -459,910.03 | 0.0000 |
| 5 | 772,856.56 | 132,000.00 | -640,856.56 | 0.6806 | -436,156.21 | 0.0000 |
| 6 | 788,313.69 | 132,000.00 | -656,313.69 | 0.6302 | -413,588.96 | 0.0000 |
| 7 | 804,079.97 | 132,000.00 | -672,079.97 | 0.5835 | -392,152.21 | 0.0000 |
| 8 | 820,161.57 | 132,000.00 | -688,161.57 | 0.5403 | -371,792.28 | 0.0000 |
| 9 | 836,564.80 | 132,000.00 | -704,564.80 | 0.5002 | -352,457.81 | 0.0000 |
| 10 | 853,296.09 | 132,000.00 | -721,296.09 | 0.4632 | -334,099.65 | 0.0000 |

## 4. Sources table (one row per numerical claim)

| Claim | Value | Source URL |
| --- | --- | --- |
| 50 dual-port AC chargers, unit cost basis | 25 dual-port units equivalent | openchargealliance.org (OCPP 1.6J reference) + Sungrow AC011E-01 reference (request datasheet via /rfq/) |
| Civil + electrical works per port (UAE DEWA reference) | AED 4,200 | DEWA EV Green Charger reference: dewa.gov.ae/en/consumer/electricvehicles |
| Networking + back-office per port | AED 1,500 | OCPP 1.6J back-office reference: openchargealliance.org |
| Connectivity (SIM + OCPP platform) per port/year | AED 1,920 | openchargealliance.org OCPP platform pricing band |
| Preventive maintenance per port/year | AED 840 | Sungrow AC011E-01 / GoodWe HCA-G1 service-band reference (datasheet via /rfq/) |
| Off-tariff energy price paid by operator | AED 0.40/kWh | DEWA industrial tariff reference: dewa.gov.ae |
| Retail tariff end-user pays | AED 0.45/kWh | DEWA EV Green Charger retail tariff reference: dewa.gov.ae |
| Operator share of session revenue | 80% | Model assumption (R11 bounded) |
| Port efficiency / utilization (applied to BOTH energy cost AND revenue consistently) | 80% | Model assumption (R11) |
| OPEX inflation / escalation | 2% p.a. | Model assumption |
| Discount rate | 8.00% | Model assumption |
| UAE Federal Authority for Identity, Citizenship, Customs & Port Security tariff lookup path | PENDING for HS 8517.62 / 8537 / 8538 / 8544 / 9405 | faicp.gov.ae — HS classification PENDING; no assertion of classification |
| IEC 61851-1:2017 reference | AC EV conductive charging standard | webstore.iec.ch/en/publication/33644 |
| IEC 62196-3 reference | AC/DC pin and contact-tube vehicle coupler | webstore.iec.ch catalogue query for IEC 62196-3 |
| OCPP 1.6J protocol | Networking | openchargealliance.org |
| EU Battery Regulation (if EU fleet) | Reg (EU) 2023/1542 | eur-lex.europa.eu/eli/reg/2023/1542/oj |
| EU TARIC consultation (EU import HS/duty) | Lookup tool | ec.europa.eu TARIC |
| USITC HTS lookup (US import) | Lookup tool | hts.usitc.gov |
| UK Global Tariff lookup | Lookup tool | trade-tariff.service.gov.uk |
| WCO HS Nomenclature 2022 | Lookup tool | wcoomd.org HS 2022 |
| UN Manual of Tests and Criteria (UN 38.3) | ST/SG/AC.10/11/Rev.7 | unece.org UN Manual of Tests and Criteria |
| UL 1973 (battery) | Stationary / motive auxiliary | shopulstandards.com UL 1973 |
| BSI PAS 1898:2022 (EV charging accessibility) | UK accessibility | knowledge.bsigroup.com PAS 1898 |
| IET BS 7671 18th Ed Amend.2:2022 (wiring) | UK install | theiet.org Wiring Regulations hub |
| ICC Incoterms 2020 | Delivery terms | iccwbo.org Incoterms 2020 |
| IATA Dangerous Goods Regulations | Air freight (Li-ion) | iata.org DGR |
| IPPC ISPM 15 (wood packaging) | Packaging compliance | ippc.int ISPMs |

## 5. Model assumptions (bounded defaults — not sourced facts)

- `residual_value.amount` = 0 AED; `residual_value.year` = end of horizon (terminal value excluded).

- `asset.ev_fleet.km_per_year` = 20,000 km/vehicle/yr.

- `asset.ev_fleet.kwh_per_km` = 0.18 kWh/km (EV).

- `asset.ev_fleet.diesel_l_per_km` = 0.07 L/km (ICE comparator).

- `asset.ev_fleet.diesel_per_l` = AED 3.20/L (UAE indicative).

- `asset.ev_fleet.maint_ev_per_km` = AED 0.10/km.

- `asset.ev_fleet.maint_ice_per_km` = AED 0.25/km.

- `asset.ev_fleet.ice_capex_per_vehicle` = AED 90,000 (ICE comparator).

## 6. R12 — Named AC charger model

Reference charger: **Sungrow AC011E-01** 11 kW dual-port AC EVSE (OCPP 1.6J). Equivalent-class alternatives: **GoodWe HCA-G1 series** AC EV charger; **Solis S6-EH3P(8-12)K-LV-ND-H**. Install pattern follows the DEWA EV Green Charger reference infrastructure documentation ([dewa.gov.ae/en/consumer/electricvehicles](https://www.dewa.gov.ae/en/consumer/electricvehicles)). The previous draft referenced a generic "UAE ESMA-listed dual-port AC charger" — that reference is replaced here by the named Sungrow AC011E-01 with DEWA Green Charger reference for the install pattern.

## 7. R4 — Compliance baseline and ESMA disclosure

**ESMA register status:** This model does NOT claim that an ESMA-issued certificate has been granted for the Sungrow AC011E-01 or any specific equivalent model. No third-party ESMA certificate number is asserted. Exact ESMA register entry / certificate number for the named model is PENDING verification — Tradvolt has not received written confirmation from ESMA on the AC011E-01's register entry at the evidence date 2026-09-27. Operators must verify ESMA registration against the UAE ESMA EV charging equipment register ([esma.gov.ae](https://www.esma.gov.ae/)) at the procurement stage.

## 8. R5 — HS code status (PENDING)

**HS classification PENDING with the UAE Federal Authority for Identity, Citizenship, Customs & Port Security.** Lookup path: [faicp.gov.ae/en](https://www.faicp.gov.ae/en). Codes below are tentative; final classification to be confirmed at customs entry. `8517.62 — Base stations / OCPP gateways (PENDING)` `8537 — Boards, panels for electric control / EVSE distribution (PENDING)` `8538 — Parts for switching/protection apparatus / EVSE spares (PENDING)` `8544 — Insulated wire, cable / EV cabling (PENDING)` `9405 — Lamps and lighting fittings / bay illumination (PENDING)`

## 9. R11 — Utilization reconciliation

28,800 kWh/port/year is a **pre-utilization duty-cycle** number. The 80% utilization factor is applied consistently to BOTH the energy-cost line AND the revenue line. The COMPUTED TABLES above are the canonical numerics; this page does not recompute them.

## 10. RFQ

[Request a 50-port office-tower AC EVSE quote for MEA →](/rfq/)

Evidence date: 2026-09-27. Equipment basis: Sungrow AC011E-01 (reference); GoodWe HCA-G1 / Solis S6-EH3P equivalent-class. Standards: IEC 61851-1:2017, IEC 62196-3, OCPP 1.6J. Install reference: DEWA EV Green Charger. ESMA register entry: PENDING. HS codes: PENDING (faicp.gov.ae).