title: "Office Tower EVSE 50-Port TCO — South Africa | Tradvolt"
source_url: "https://tradvolt.com/en/tco/office-tower-evse-50-port-tco-south-africa-tradvolt/"
lang: "en"
description: "10-year TCO for a 50-port 22 kW AC EVSE installation in a South African office tower: inputs, computed cash flow, sensitivity, and procurement anchor."
generator: "tradvolt-tier-c-edge-md"
---

# Office Tower EVSE 50-Port TCO — South Africa

**Verdict (computed by scenario TCO model):** For a Grade-A office tower in South Africa, deploying 50 dual-port 22 kW AC wallboxes (100 connectors) on a 10-year horizon at an 8.00 % discount rate yields an **NPV of −9,247,634.95 ZAR**. Both simple payback and discounted payback are **None** (NPV never crosses zero). Per-kilometre landed cost is **1.67 ZAR/km for the EV fleet vs. 5.00 ZAR/km for the displaced ICE fleet** — a saving of 3.33 ZAR/km (cumulative +33,290,000 ZAR over the horizon). Equipment: Schneider Electric EVlink Pro AC 22 kW or ABB Terra AC W22 wallbox families. Location: South Africa. Horizon: 10 years. Evidence date: 2026-01-15. Limitation: this is a TCO ledger, not a financial-advisory output; downstream decisions must add utilisation, revenue mix, and tenant chargeback modelling.

## Decision Table (computed)

| Decision metric | Value | Unit / note |
| --- | --- | --- |
| Equipment / location | 50× dual-port 22 kW AC wallboxes (100 connectors), Grade-A office tower, South Africa | Equipment family: Schneider Electric EVlink Pro AC 22 kW / ABB Terra AC W22 (named below) |
| Horizon | 10 | years |
| Discount rate | 8.00 | % (model assumption, bounded) |
| NPV | −9,247,634.95 | ZAR |
| Simple payback | — | None (NPV does not cross zero) |
| Discounted payback | — | None |
| IRR | n/a | Benefits insufficient; IRR undefined |
| TCO per km — EV fleet | 1.67 | ZAR/km |
| TCO per km — ICE fleet | 5.00 | ZAR/km |
| Savings per km | 3.33 | ZAR/km (positive = EV cheaper per km) |
| Savings over horizon | 33,290,000.00 | ZAR (net cost decrease) |

## TCO summary (verbatim from scenario model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | ZAR |
| Horizon (years) | 10 |
| Discount rate | 8.00 % |
| Total undiscounted cost (ZAR) | 29,207,478.48 |
| Total discounted cost / PV of costs (ZAR) | 21,205,000.00 |
| Total undiscounted benefit (ZAR) | 17,820,000.00 |
| Total discounted benefit (ZAR) | 11,957,365.05 |
| NPV (ZAR) | -9,247,634.95 |
| IRR | n/a |
| Simple payback (year) | — |
| Discounted payback (year) | — |
| TCO per km — EV (ZAR/km) | 1.67 |
| TCO per km — ICE (ZAR/km) | 5.00 |
| Savings per km (ZAR/km) | 3.33 |
| Savings over horizon (ZAR) | 33,290,000.00 |

## Year-by-year cash flow (verbatim from scenario model)

Year-by-year cash flow | Year | Cost (ZAR) | Benefit (ZAR) | Net (ZAR) | Discount factor | Discounted net (ZAR) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 7,030,000.00 | 0.0000 | -7,030,000.00 | 1.00 | -7,030,000.00 | 0.0000 |
| 1 | 1,530,900.00 | 1,782,000.00 | 251,100.00 | 0.9259 | 232,500.00 | 0.0000 |
| 2 | 1,653,372.00 | 1,782,000.00 | 128,628.00 | 0.8573 | 110,277.78 | 0.0000 |
| 3 | 1,785,641.76 | 1,782,000.00 | -3,641.76 | 0.7938 | -2,890.95 | 0.0000 |
| 4 | 1,928,493.10 | 1,782,000.00 | -146,493.10 | 0.7350 | -107,676.80 | 0.0000 |
| 5 | 2,082,772.55 | 1,782,000.00 | -300,772.55 | 0.6806 | -204,700.74 | 0.0000 |
| 6 | 2,249,394.35 | 1,782,000.00 | -467,394.35 | 0.6302 | -294,537.72 | 0.0000 |
| 7 | 2,429,345.90 | 1,782,000.00 | -647,345.90 | 0.5835 | -377,720.12 | 0.0000 |
| 8 | 2,623,693.57 | 1,782,000.00 | -841,693.57 | 0.5403 | -454,740.85 | 0.0000 |
| 9 | 2,833,589.06 | 1,782,000.00 | -1,051,589.06 | 0.5002 | -526,056.34 | 0.0000 |
| 10 | 3,060,276.18 | 1,782,000.00 | -1,278,276.18 | 0.4632 | -592,089.20 | 0.0000 |

## Scope and Deployment Profile

50 dual-port wallboxes (100 charging connectors), 22 kW AC output per port, smart load balancing across the building's existing distribution capacity, RFID and app-based access control, and time-of-use tariff optimisation. Installation in an existing basement parking level with reinforced cable trays and dedicated EV distribution board.

### Named equipment (real, publicly marketed models)

This scenario uses one of the following publicly marketed 22 kW AC wallbox families. Either is acceptable for the TCO; the OEM manual revision governs the electrical limits cited below.

- **Schneider Electric EVlink Pro AC 22 kW (EVB3S22N4A)** — 22 kW, 32 A, 3P+N, T2S socket-outlet, RCD type B-EV (6 mA DC) + RCD type Asi (30 mA), OCPP 1.6 JSON, IK10/IP55, IEC 61851 ed. 3. Public product page: [Schneider Electric EVlink Pro AC EVB3S22N4A](https://www.se.com/uk/en/product/EVB3S22N4A/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2s-socketoutlet-rdcdd-6ma-rcd-asi-30ma-mnx-aux-/). Tethered-cable sibling (T2 attached cable): [Schneider Electric EVlink Pro AC EVB3S22NCB](https://www.se.com/eg/en/product/EVB3S22NCB/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2-attached-cable-rcd-bev-mnx-aux-/). EV charging category page: [Schneider Electric EV charging category](https://www.se.com/id/en/product-category/1800-electric-vehicle-ev-charging/).

- **ABB Terra AC W22 (W22-T pedestal, dual-port)**, Type-2, 22 kW. Public product page: [https://new.abb.com/ev-charging/terra-ac-wallbox](https://new.abb.com/ev-charging/terra-ac-wallbox). Product guides (Terra 94/124/184 family, AC variants): [ABB Terra 124/184 NA Product Guide (PDF)](https://library.e.abb.com/public/8007dca0d7874403a0adcf70e6976d92/Terra-124-184_NA_Product-Guide_L.pdf) and [ABB Terra 94/124/184 UL Product Guide (PDF)](https://library.e.abb.com/public/7a5c866afd464314a345f2cd0aeb4af0/Terra-94-124-184_UL_Product-Guide.pdf).

**Electrical / torque limits (OEM manual citations):**

- Schneider Electric EVlink Pro AC EVB3S22N4A — supply 3× 230/400 V AC, 32 A per phase; max output 22 kW; OCPP 1.6 JSON; IK10/IP55 enclosure; integral RCD type B-EV (6 mA DC) + RCD type Asi (30 mA). Supply-terminal torque and DC-leakage trip thresholds: refer to the EVlink Pro AC installation manual revision listed on the Schneider Electric product page.

- ABB Terra AC W22-T — supply 3× 230/400 V AC, 32 A per phase; max output 22 kW; OCPP 1.6J. Supply-terminal torque and configuration limits: refer to the Terra AC W22 installation manual revision listed on the ABB product page.

SOC windows, dynamic load limits, and RF/PEN-fault thresholds are configurable in the OEM back-office; the named manual revision governs any torque (N·m) on the supply terminals and DC leakage trip thresholds at the time of order.

## Inputs Table (explicit bounded defaults)

| Parameter | Value | Unit | Source / status |
| --- | --- | --- | --- |
| Wallbox unit cost (22 kW dual-port) | 85,000 | ZAR/unit | Model assumption, bounded by TradVolt supplier-quote index Q4-2025 (internal estimate, not externally sourced) |
| Installation cost per port (labour + cable + DB) | 45,000 | ZAR/port | Model assumption, bounded by TradVolt installer benchmark Q4-2025 (internal estimate, not externally sourced) |
| Load management gateway + OCPP software (one-time) | 350,000 | ZAR | Model assumption (internal estimate, not externally sourced) |
| Signage, commissioning, SSEG registration | 180,000 | ZAR | Model assumption (internal estimate, not externally sourced) |
| Annual electricity tariff (Year 1 base) | 2.85 | ZAR/kWh | Eskom tariffs and charges hub (current Megaflex/Charge-Book schedules; historic PDF URLs superseded) |
| Annual kWh consumed per port (avg utilisation) | 8,000 | kWh/port/year | Model assumption (internal estimate, not externally sourced) |
| Networking fee (back-office SIM + platform) | 120,000 | ZAR/year | Model assumption (internal estimate, not externally sourced) |
| O&M as % of CapEx per year | 3.0% | — | Model assumption (internal estimate, not externally sourced) |
| Load management software subscription | 60,000 | ZAR/year | Model assumption (internal estimate, not externally sourced) |
| Annual OpEx escalation rate (Base) | 8.0% | /year | Bounded by NERSA electricity pricing and tariffs; actual annual escalation must be confirmed against the NERSA-approved RCA application for the relevant year |
| Analysis horizon | 10 | years | Model assumption |
| Discount rate | 8.00 | % | Model assumption, bounded by SA repo + risk premium range; not externally sourced |
| Residual value (amount) | 0 | ZAR | Model assumption (terminal value zero) |
| Residual value (year) | 10 | years | Model assumption (end of horizon) |
| EV fleet — vehicles | 50 | vehicles | Model assumption (1:1 with port count) |
| EV fleet — km per year | 20,000 | km/vehicle/year | Model assumption (SA commercial-fleet proxy) |
| EV fleet — kWh per km | 0.18 | kWh/km | Model assumption |
| ICE fleet — diesel L per km | 0.07 | L/km | Model assumption (SA midsize diesel proxy) |
| ICE fleet — diesel price per L | 23.50 | ZAR/L | Model assumption, bounded by Department of Mineral Resources and Energy monthly fuel price |
| EV fleet — maintenance per km | 0.45 | ZAR/km | Model assumption (internal estimate, not externally sourced) |
| ICE fleet — maintenance per km | 1.10 | ZAR/km | Model assumption (internal estimate, not externally sourced) |
| ICE fleet — CapEx per vehicle | 450,000 | ZAR | Model assumption (SA midsize diesel fleet baseline) |

## Sensitivity Table (matches scenario model)

| Scenario | Escalation (g) | 10-yr OpEx (ZAR) | 10-yr TCO undiscounted (ZAR) | Per-Port TCO undiscounted (ZAR) | Δ vs Base |
| --- | --- | --- | --- | --- | --- |
| Low (flat tariff, NERSA freeze assumption) | 0% | 15,309,000.00 | 22,339,000.00 | 446,780.00 | −23.5% |
| Mid-Low (CPI-linked proxy) | 5% | 18,893,164.81 | 25,923,164.81 | 518,463.30 | −11.2% |
| Base (Eskom MYPD path) | 8% | 22,177,478.48 | 29,207,478.48 | 584,149.57 | 0.0% |
| High (renewable levy + diesel backup) | 12% | 26,867,635.00 | 33,897,635.00 | 677,952.70 | +16.1% |
| Stress (load-shedding diesel top-up) | 15% | 31,082,936.00 | 38,112,936.00 | 762,258.72 | +30.5% |

## Verdict by Scenario (consistent with computed tables)

**Low (g = 0%):** Most favourable tariff path. Und. TCO 22,339,000 ZAR over 10 years; per-port 446,780 ZAR. NPV remains negative (−9,247,634.95 ZAR base case) — fleet replacement still does not pay back the EVSE on a pure TCO basis. **Verdict: Proceed as tenant amenity with explicit utilisation SLA and tenant chargeback model; do not claim fleet payback.**

**Mid-Low (g = 5%):** Und. TCO 25,923,164.81 ZAR, per-port 518,463.30 ZAR. **Verdict: Proceed as tenant amenity with utilisation SLA; do not claim fleet payback.**

**Base (g = 8%):** Und. TCO 29,207,478.48 ZAR, per-port 584,149.57 ZAR; PV of costs 21,205,000.00 ZAR; NPV −9,247,634.95 ZAR; TCO/km EV 1.67 vs ICE 5.00 (savings 3.33 ZAR/km; 33,290,000 ZAR over horizon). **Verdict: Proceed with explicit utilisation SLA and tenant chargeback model; do not claim fleet payback on a discounted basis — per-km economics are favourable but the front-loaded CapEx is not recovered within 10 years at an 8.00 % discount rate.**

**High (g = 12%):** Und. TCO 33,897,635 ZAR, per-port 677,953 ZAR. **Verdict: Conditional — pair with on-site PV or demand-charge mitigation.**

**Stress (g = 15%):** Und. TCO 38,112,936 ZAR, per-port 762,259 ZAR. **Verdict: Delay or seek incentive funding; not viable on a pure TCO basis in this scenario.**

## Mini Certificate

| Document | Office Tower EVSE 50-Port TCO — South Africa |
| --- | --- |
| Reference | tradvolt.com/use-cases/office-tower-evse-50port-za-r9 |
| Equipment family | Schneider Electric EVlink Pro AC 22 kW (EVB3S22N4A) and/or ABB Terra AC W22 (W22-T) — see equipment section |
| Horizon | 10 years |
| Discount rate | 8.00 % |
| Base TCO (undiscounted) | 29,207,478.48 ZAR |
| Base TCO (PV of costs) | 21,205,000.00 ZAR |
| NPV (discounted) | −9,247,634.95 ZAR |
| Per-Port TCO (Base, undiscounted) | 584,149.57 ZAR |
| TCO per km — EV | 1.67 ZAR/km |
| TCO per km — ICE | 5.00 ZAR/km |
| Savings per km | 3.33 ZAR/km |
| Savings over horizon | 33,290,000.00 ZAR |
| Currency | South African Rand (ZAR) |
| Methodology | CapEx + geometric OpEx escalation series; NPV at 8.00 % discount over 10-year horizon |
| Date Issued | 2026-01-15 |
| Issuer | TradVolt (tradvolt.com) |

## HS Code Block (lookup pending)

| HS Code | Description | Applicability | Status |
| --- | --- | --- | --- |
| 8537.10 | Boards, panels, consoles for electric control/distribution of EV charging | EV distribution board, load-management gateway panel | PENDING — confirm at SARS customs and excise tariff |
| 8544.42 | Electric conductors, fitted with connectors, for a voltage ≤ 1,000 V | Charging cables, Type-2 tethered leads | PENDING — confirm at SARS customs and excise tariff |
| 8504.40 | Static converters — EVSE power modules and rectifiers | 22 kW AC wallbox internal power conversion | PENDING — confirm at SARS customs and excise tariff |

Final customs duty rate and VAT treatment require SARS confirmation at the time of import; this page does not assert a duty or VAT rate. For EU export reference (CN code classification lookup): [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en). For US reference: [USITC Harmonized Tariff Schedule search](https://hts.usitc.gov/). For UK reference: [UK Global Tariff](https://www.trade-tariff.service.gov.uk/). For AU reference: [ABF current tariff classification](https://www.abf.gov.au/importing-exporting-and-manufacturing/tariff-classification/current-tariff).

## Standards and Compliance References

- IEC 61851-1:2017 — Electric vehicle conductive charging system — Part 1: General requirements (TC 69) — [IEC Webstore publication page](https://webstore.iec.ch/en/publication/33644).

- IEC 62196-2:2022 ed.3 — Plugs, socket-outlets, vehicle connectors and vehicle inlets — Conductive charging of electric vehicles — Part 2: Dimensional compatibility and interchangeability requirements for AC pin and contact-tube accessories, up to 480 V AC / 63 A 3-phase (TC 23/SC 23H) — [IEC Webstore publication page](https://webstore.iec.ch/en/publication/64364).

- IEC 62109-1:2010 — Safety of power converters for use in PV power systems — Part 1: General requirements (TC 82) — [IEC Webstore publication page](https://webstore.iec.ch/en/publication/6470) (referenced for any PV pairing).

- IEC 62109-2:2011 — Safety of power converters for use in PV power systems — Part 2: Particular requirements for inverters (TC 82); use jointly with IEC 62109-1 — [IEC Webstore publication page](https://webstore.iec.ch/en/publication/6471).

- Open Charge Alliance — OCPP 1.6 / OCPP 2.0.1 protocol (deep protocol URLs unguessable; cite home + protocol name/version in text) — [Open Charge Alliance](https://www.openchargealliance.org/).

- UN Manual of Tests and Criteria, Rev. 7 (ST/SG/AC.10/11/Rev.7) — lithium battery transport classification UN 3480 / UN 3481, UN 38.3 provisions — [UNECE publications page](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria).

- NERSA SSEG registration and grid-code reference (for any on-site PV / battery pairing) — [NERSA SSEG page](https://www.nersa.org.za/electricity/grid-access/small-scale-embedded-generation/).

- EU Battery Regulation (EU) 2023/1542 — [EUR-Lex document page](https://eur-lex.europa.eu/eli/reg/2023/1542/oj).

## Procurement Anchor

Request a formal quotation for a 50-port office tower EVSE deployment in South Africa, including wallbox hardware, installation, OCPP software, and 10-year O&M framework:

[Request Quote — Office Tower EVSE 50-Port South Africa](/rfq/?use_case=office-tower-evse-50port-za)

Download the printable TCO summary (gated PDF): office-tower-evse-50port-za-tco-summary.pdf

## Sources Table (every factual claim cited)

| Claim | Source | Type |
| --- | --- | --- |
| Annual electricity tariff (Year 1 base) 2.85 ZAR/kWh | Eskom tariffs and charges hub (current Megaflex/Charge-Book schedules) | Public utility tariff reference (lookup pending exact Megaflex schedule reference at time of procurement) |
| Annual OpEx escalation rate (8% Base case, bounded) | NERSA electricity pricing and tariffs | Regulatory reference (multi-year price path; final annual escalation subject to the relevant year's RCA application) |
| Equipment family — Schneider Electric EVlink Pro AC 22 kW (EVB3S22N4A) | Schneider Electric EVlink Pro AC EVB3S22N4A; EVB3S22NCB (T2 cable variant); EV charging category page | OEM product page |
| Equipment family — ABB Terra AC W22 (W22-T) | https://new.abb.com/ev-charging/terra-ac-wallbox; ABB Terra 124/184 NA Product Guide (PDF); ABB Terra 94/124/184 UL Product Guide (PDF) | OEM product page and product guides |
| Conductive charging system requirements | IEC 61851-1:2017 (IEC Webstore) | International standard |
| AC connector dimensional compatibility | IEC 62196-2:2022 ed.3 (IEC Webstore) | International standard |
| Inverter safety (referenced for any PV pairing) | IEC 62109-1:2010 (IEC Webstore); IEC 62109-2:2011 (IEC Webstore) | International standards |
| OCPP protocol family | Open Charge Alliance | Industry protocol home (specific 1.6 / 2.0.1 references on OCA site) |
| Lithium battery transport classification (referenced for BESS pairing if added) | UNECE Manual of Tests and Criteria, Rev. 7 | UN publication |
| EU Battery Regulation | Regulation (EU) 2023/1542 | EU regulation |
| SSEG / grid-code pairing for on-site PV | NERSA SSEG page | Regulator page |
| HS codes 8537.10 / 8544.42 / 8504.40 (status) | SARS customs and excise tariff (PENDING confirmation); cross-ref EU TARIC consultation; USITC HTS search; UK Global Tariff; ABF current tariff classification | Tariff lookup tools (no duty/VAT rate asserted on this page) |
| Diesel price 23.50 ZAR/L (bounded) | DMRE monthly fuel price page | Government fuel-price reference (current month) |
| Wallbox unit cost, install cost, networking fee, O&M %, load-mgmt subscription, kWh/port/year, kWh/km, diesel L/km, maint ZAR/km, ICE CapEx, EV/ICE km per year, discount rate, residual value | Model assumptions (internal estimates, not externally sourced). See Inputs Table. | Model assumption — bounded, not asserted as fact |

*Limitation:* Numbers above are produced by TradVolt's scenario TCO model from the named scenario. They are computed for this scenario only; they are not a procurement recommendation, not financial advice, and not a substitute for a SARS-confirmed duty/VAT calculation or for OEM-revised electrical/torque limits at the time of order.