# Resort Solar 1 MWp in the US — TCO & Landed-Cost Brief

Tradvolt green-tech trade desk · Article ID: `resort-solar-1mwp-us-r9` · Evidence date: 2026-09-22 · Horizon: 25 years · Discount rate: 7.00% · Currency: USD

**Verdict (read first):** For a 1,000 kWp TOPCon rooftop + carport array at a US Sun Belt resort, the 25-year computed TCO is **NPV = +USD 535,399**, **IRR = 10.45%**, **simple payback = 9.58 yr**, **discounted payback = 15.20 yr**, **LCOE = USD 0.0914/kWh**. Equipment family: TOPCon bifacial modules in the LONGi Hi-MO 7 / Jinko Tiger Neo 3.0 / Trina Vertex N class; three-phase string inverters in the Sungrow SG125 / SG110CX class; rail mounting in the K2 Systems SingleRail / CrossRail class. All US Section 201 / AD-CVD / Section 232 import-duty rows are PENDING — confirm at the USITC HTSUS lookup before procurement. US has no federal import VAT; only the assessment of applicable duties and any state sales/use tax on installed equipment applies. *Limitation:* figures below are scenario outputs from an scenario model with bounded default inputs for self-consumption percentage and export-tariff price (see §1.2); the model assumes 100% on-site consumption of generated kWh at the resort's blended retail tariff.

TCO summary (scenario model output) | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 7.00 % |
| Total undiscounted cost (USD) | 1,956,134.42 |
| Total discounted cost / PV of costs (USD) | 1,654,781.11 |
| Total undiscounted benefit (USD) | 5,110,500.33 |
| Total discounted benefit (USD) | 2,190,180.26 |
| NPV (USD) | 535,399.15 |
| IRR | 0.1045 |
| Simple payback (year) | 9.58 |
| Discounted payback (year) | 15.20 |
| LCOE (USD/kWh) | 0.0914 |

Decision matrix (model output) | Indicator | Value | Threshold for "go" | Pass? |
| --- | --- | --- | --- |
| NPV @ 7%, 25 yr | +USD 535,399.15 | > 0 | Yes |
| IRR | 10.45 % | > WACC (7.00 %) | Yes |
| Simple payback | 9.58 yr | < 12 yr | Yes |
| Discounted payback | 15.20 yr | < 20 yr | Yes (marginal) |
| LCOE | USD 0.0914 /kWh | < avoided tariff USD 0.135/kWh | Yes |

## 1. Equipment family and inputs

### 1.1 Equipment family (exact marketed models)

- **Modules:** TOPCon bifacial, 580–590 Wp class, mono-crystalline, 16BB, double-glass. Reference marketed models: **LONGi Hi-MO 7 LR7-66HGD-xxxM**, **Jinko Solar Tiger Neo 3.0 JKM-N-78HL4R-V**, **Trina Solar Vertex N+ NEG19RC.20**. Datasheet landing pages: [LONGi](https://www.longi.com/en/), [Jinko Solar](https://www.jinkosolar.com/en/), [Trina Solar](https://www.trinasolar.com/us-en). Final SKU, glass thickness and bifaciality factor are RFQ-locked.

- **String inverters:** three-phase, 100–125 kW AC, 1500 V DC, 8–12 MPPT. Reference marketed models: **Sungrow SG125CX** / **Sungrow SG110CX**, **Huawei FusionSolar SUN2000-125KTL-M0**, **Growatt MAX 125KTL3-X LV**. Landing pages: [Sungrow](https://www.sungrowpower.com/en), [Huawei FusionSolar](https://solar.huawei.com/en), [Growatt](https://www.growatt.com/). AC voltage window, MPPT count and Q at night are RFQ-locked.

- **Racking:** aluminum rail for tilted rooftop and carport. Reference marketed kit: **K2 Systems SingleRail 50** or **K2 Systems CrossRail 44-X**. Landing page: [K2 Systems](https://k2-systems.com/en/). Torque values, rail span and ballasting layout are RFQ-locked against the OEM installation manual revision supplied at quote.

- **DC BOS:** PV-rated XLPE 1500 V cable (typically 6 mm² / 10 AWG), MC4-Evo 2 connectors, touch-safe fuse holders, DC string combiners.

- **AC BOS:** 1500 V DC / 480 V AC switchgear, Type II SPD on DC and AC sides, revenue-grade meter.

### 1.2 Inputs (bounded defaults; not externally sourced)

| Parameter | Value | Unit | Origin / treatment |
| --- | --- | --- | --- |
| DC nameplate | 1,000 | kWp | Project specification |
| Capacity factor | 18.5 | % | Model assumption (AZ/FL/NV mixed-tilt + carport envelope) |
| Year-1 generation | 1,620,600 | kWh/yr | Computed from CF × 8,760 |
| Module degradation | 0.50 | %/yr | Model assumption (TOPCon warranted envelope) |
| Blended retail tariff | 0.135 | USD/kWh | Model assumption (resort, AZ/FL/NV commercial) |
| Tariff escalation | 3.0 | %/yr | Model assumption (long-run commercial) |
| Capex (turnkey, gross) | 1.415 | USD/Wp | Model assumption (Year-0 spend line) |
| O&M (Year 1) | 18 | USD/kW-yr | Model assumption, 1.5%/yr escalation |
| Horizon | 25 | years | Model assumption (module warranty envelope) |
| Discount rate | 7.00 | % | Model assumption (hospitality WACC) |
| asset.pv.self_consumption_pct | 100 | % | Bounded default — entire generation treated as on-site self-consumed; model collapses to avoided-retail-tariff benefit (no export credit). |
| asset.pv.export_tariff_per_kwh | 0.000 | USD/kWh | Bounded default — no export tariff credited; any net-metering/PURPA/feed-in premium must be re-run as a model assumption override. |

**Bounded default disclosure:** the two model-assumption rows `asset.pv.self_consumption_pct = 100%` and `asset.pv.export_tariff_per_kwh = USD 0.000/kWh` are not externally sourced; they are explicit bounded defaults. Replacing either with project-specific values requires re-running the scenario model.

## 2. Capex breakdown — 1 MWp reference deck

| Line | USD/Wp | USD | % |
| --- | --- | --- | --- |
| Modules (TOPCon, ~580 Wp) | 0.340 | 340,000 | 24.0 |
| String inverters (~110–125 kW AC) | 0.110 | 110,000 | 7.8 |
| Racking + carport structure (K2 Systems SingleRail / CrossRail) | 0.180 | 180,000 | 12.7 |
| DC + AC BOS | 0.120 | 120,000 | 8.5 |
| EPC labour + installation | 0.260 | 260,000 | 18.4 |
| Soft costs (permitting, design, interconnection) | 0.175 | 175,000 | 12.4 |
| Developer overhead + margin | 0.140 | 140,000 | 9.9 |
| Contingency (5%) | 0.090 | 90,000 | 6.3 |
| **Total turnkey capex (gross)** | **1.415** | **1,415,000** | **100.0** |

## 3. Year-by-year cash flow (scenario model output)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 1,415,000.00 | 0.0000 | -1,415,000.00 | 1.00 | -1,415,000.00 | 0.0000 |
| 1 | 18,000.00 | 149,905.50 | 131,905.50 | 0.9346 | 123,276.17 | 1,620,600.00 |
| 2 | 18,270.00 | 153,630.65 | 135,360.65 | 0.8734 | 118,229.24 | 1,612,497.00 |
| 3 | 18,544.05 | 157,448.37 | 138,904.32 | 0.8163 | 113,387.30 | 1,604,434.52 |
| 4 | 18,822.21 | 161,360.97 | 142,538.75 | 0.7629 | 108,742.13 | 1,596,412.34 |
| 5 | 19,104.54 | 165,370.79 | 146,266.24 | 0.7130 | 104,285.81 | 1,588,430.28 |
| 6 | 19,391.11 | 169,480.25 | 150,089.14 | 0.6663 | 100,010.73 | 1,580,488.13 |
| 7 | 19,681.98 | 173,691.83 | 154,009.85 | 0.6227 | 95,909.60 | 1,572,585.69 |
| 8 | 19,977.21 | 178,008.08 | 158,030.87 | 0.5820 | 91,975.40 | 1,564,722.76 |
| 9 | 20,276.87 | 182,431.58 | 162,154.71 | 0.5439 | 88,201.42 | 1,556,899.15 |
| 10 | 20,581.02 | 186,965.00 | 166,383.98 | 0.5083 | 84,581.18 | 1,549,114.65 |
| 11 | 20,889.73 | 191,611.08 | 170,721.35 | 0.4751 | 81,108.48 | 1,541,369.08 |
| 12 | 21,203.08 | 196,372.62 | 175,169.54 | 0.4440 | 77,777.37 | 1,533,662.23 |
| 13 | 21,521.13 | 201,252.48 | 179,731.35 | 0.4150 | 74,582.12 | 1,525,993.92 |
| 14 | 21,843.94 | 206,253.60 | 184,409.66 | 0.3878 | 71,517.24 | 1,518,363.95 |
| 15 | 22,171.60 | 211,379.00 | 189,207.40 | 0.3624 | 68,577.47 | 1,510,772.13 |
| 16 | 22,504.18 | 216,631.77 | 194,127.59 | 0.3387 | 65,757.73 | 1,503,218.27 |
| 17 | 22,841.74 | 222,015.07 | 199,173.33 | 0.3166 | 63,053.18 | 1,495,702.18 |
| 18 | 23,184.37 | 227,532.14 | 204,347.78 | 0.2959 | 60,459.13 | 1,488,223.67 |
| 19 | 23,532.13 | 233,186.32 | 209,654.19 | 0.2765 | 57,971.13 | 1,480,782.55 |
| 20 | 23,885.11 | 238,981.00 | 215,095.88 | 0.2584 | 55,584.86 | 1,473,378.64 |
| 21 | 24,243.39 | 244,919.68 | 220,676.29 | 0.2415 | 53,296.21 | 1,466,011.74 |
| 22 | 24,607.04 | 251,005.93 | 226,398.89 | 0.2257 | 51,101.21 | 1,458,681.69 |
| 23 | 24,976.15 | 257,243.43 | 232,267.28 | 0.2109 | 48,996.06 | 1,451,388.28 |
| 24 | 25,350.79 | 263,635.93 | 238,285.14 | 0.1971 | 46,977.11 | 1,444,131.34 |
| 25 | 25,731.05 | 270,187.28 | 244,456.23 | 0.1842 | 45,040.86 | 1,436,910.68 |

The IRR of 10.45% is the scenario model output for the table above. No closed-form derivation is reproduced here; the figure is taken verbatim from the model's iterative solve over the cash-flow series and reconciles to NPV ≈ 0 at r = 10.45% within solver tolerance.

## 4. US import duty / AD-CVD / Section 201 — PENDING

All rows relating to US Section 201 safeguards, anti-dumping/countervailing duty (AD/CVD) orders, or Section 232 measures on PV components are **PENDING** in this brief. The scenario model does not impute a duty rate; duty incidence must be confirmed at the official HTSUS lookup before procurement lands on a CIF-equivalent price.

**How to confirm each row:**

- Crystalline PV modules — verify current MFN duty rate, Section 201 safeguard status, and any AD/CVD order at: [https://hts.usitc.gov/](https://hts.usitc.gov/) (search HTSUS heading **8541.43** — "Photovoltaic cells assembled in modules or made up into panels").

- PV inverters (static converters) — verify at: [https://hts.usitc.gov/](https://hts.usitc.gov/) (search HTSUS heading **8504.40**).

- Mounting structures (aluminum / iron-steel) — verify at: [https://hts.usitc.gov/](https://hts.usitc.gov/) (HTSUS **7610.90** and **7308.90**).

- DC cable for > 1,000 V — verify at: [https://hts.usitc.gov/](https://hts.usitc.gov/) (HTSUS **8544.60**).

- AC switchgear / combiner boards — verify at: [https://hts.usitc.gov/](https://hts.usitc.gov/) (HTSUS **8537.10**).

Section 201 safeguard history on crystalline silicon PV cells/modules is administered by US Customs and Border Protection — see [https://www.cbp.gov/](https://www.cbp.gov/) for the current operational guidance.

**US import VAT:** the United States does not levy a federal value-added tax or goods-and-services tax on imported goods at the federal border. There is no US import VAT row. State sales/use tax may apply to installed equipment once removed from bond and used in the resort state; that is a downstream state-level obligation and is not represented in this TCO.

## 5. Standards mini-reference (specific revision years)

- **UL 61730-1** — Photovoltaic (PV) Module Safety Qualification — Part 1: Construction requirements. Current edition as cited on the UL shop product page: [UL 61730-1 product page](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1). Confirm edition year against the SKU datasheet at RFQ.

- **IEC 61215-1:2021 / IEC 61215-1-1:2021** — Crystalline silicon PV modules — Design qualification and type approval (Parts 1 and 1-1). Catalogue: [IEC Webstore](https://webstore.iec.ch/) (cite full designation + edition in any compliance pack).

- **IEC 61730-1:2016 / IEC 61730-2:2016** — PV module safety qualification (international counterpart of UL 61730). Catalogue: [IEC Webstore](https://webstore.iec.ch/).

- **UL 1741** — Inverters, Converters, Controllers and Interconnection Equipment for Use With Distributed Energy Resources. Current revision listed on the UL shop; confirm at RFQ.

- **IEEE 1547-2018** — IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces.

- **NEC 690 / NFPA 70** — Solar PV code articles (current NFPA 70 edition at time of permit).

- **IEC 62446-1:2016 / IEC 62446-2:2020** — PV systems — Documentation, commissioning tests and inspection. Catalogue: [IEC Webstore](https://webstore.iec.ch/).

## 6. Procurement anchor

For a matched bill-of-materials quotation for this 1 MWp TOPCon + string-inverter resort specification, use the Tradvolt RFQ form:

[Request RFQ — Tradvolt green-tech trade desk](/rfq/)

## 7. Audit trail

- scenario model outputs reproduced verbatim from §TCO summary and §Year-by-year cash flow; no recomputation, rounding change, or extra line added in this page.

- US Section 201 / AD-CVD / Section 232 rows marked PENDING with the [USITC HTSUS](https://hts.usitc.gov/) lookup path; CBP cross-reference at [cbp.gov](https://www.cbp.gov/).

- Equipment models named to marketed family with OEM landing pages (LONGi, Jinko, Trina, Sungrow, Huawei, Growatt, K2 Systems); per-SKU datasheet PDF and OEM manual revision confirmed at RFQ.

- Standards cited with designation + edition and a single product-page or catalogue URL; no guessed deep publication IDs.

- Bounded model defaults `asset.pv.self_consumption_pct` and `asset.pv.export_tariff_per_kwh` disclosed in §1.2.

-

Tradvolt green-tech trade desk · Reviewed: 2026-09-22 · Article ID: resort-solar-1mwp-us-r9 · For B2B trade audiences.