title: "Supermarket Rooftop Solar 700 kWp (SEA) — Use-Case & TCO | Tradvolt"
source_url: "https://tradvolt.com/en/tco/supermarket-rooftop-solar-700-kwp-sea-use-case-tco-tradvolt/"
lang: "en"
description: "Use-case and total cost of ownership for a 700 kWp rooftop solar PV system on a supermarket in Southeast Asia, with named OEM models, cited standards, and a 25-year discounted cash flow."
generator: "tradvolt-tier-c-edge-md"
---

[Use Cases](/use-cases/) &rsaquo; Supermarket Solar 700 kWp (SEA)

# Supermarket Rooftop Solar 700 kWp (SEA) — Use-Case & TCO

Rooftop PVCommercialRetailGrid-TiedSEA

**Verdict (base case, 700 kWp DC, tropical SEA supermarket rooftop, 25-year horizon, 8.0% WACC):** The system is economically attractive: **NPV ≈ USD 927,827**, **IRR ≈ 26.57%**, **simple payback ≈ 3.88 years**, **discounted payback ≈ 4.81 years**, and **LCOE ≈ USD 0.0515 / kWh** — well below typical SEA commercial tariffs of USD 0.10–0.18 / kWh. Evidence date: 2026-09-22. Limitation: financial figures are scenario outputs from TradVolt's computed cost model; site-specific irradiance, tariff, self-consumption ratio and import duty must be re-validated before any RFQ.

| Decision metric | Base case value | Read |
| --- | --- | --- |
| NPV @ 8.0% WACC, 25 yr | USD 927,827 | Strongly positive — finance ready. |
| IRR | 26.57% | Above SEA commercial project hurdle rates. |
| Simple payback | 3.88 yr | Inside typical supermarket CapEx horizon. |
| Discounted payback | 4.81 yr | Comfortable margin vs. 25-yr asset life. |
| LCOE | USD 0.0515 / kWh | Below SEA commercial tariff band; positive spread. |

## 1. Use-Case Snapshot

- **Site:** Single-storey hypermarket / supermarket, flat concrete roof, ~5,000 m² gross roof footprint.

- **Load profile:** Strong daytime refrigeration and HVAC load — supermarket self-consumption ratio of 70–85% during solar hours.

- **System size:** 700 kWp DC (≈630 kWac after inverter derating).

- **Configuration:** Three-phase 1500 V DC string inverters, Tier-1 mono-PERC modules (550 Wp class), fixed-tilt ~10° (near-flat for low wind load), no trackers.

- **Battery storage:** Not included. PV-only model.

- **Region:** Tropical SEA — solar irradiance of 1,500–1,800 kWh/m²/yr typical.

## 2. Inputs Table (cited)

Inputs used by TradVolt's computed cost model for this scenario. Bounded model assumptions are flagged *(assumption)*; everything else is sourced from the row-numbered citations in Section 8.

| Parameter | Value | Unit | Source |
| --- | --- | --- | --- |
| DC system size (PDC) | 700 | kWp | Use-case definition (TradVolt) |
| Module family | LONGi Hi-MO 5m (LR5-72HBD), 550 Wp class, IEC 61215-1/-2:2021 + IEC 61730-1/-2:2016, TÜV Rheinland certificate family | — | OEM product page (S1) |
| Inverter model class | Huawei SUN2000-330KTL-H1, 330 kW, 1500 V DC, 8 MPPT, three-phase | — | OEM product page (S2) |
| Mounting structure family | K2 Systems S-Rack rail on ballasted low-tilt frame (rooftop kit, manual revision confirmed at RFQ) | — | OEM product page (S3) |
| Performance ratio (PR) | 0.82 | — | IEA-PVPS Trends in PV Applications 2024 — commercial rooftop benchmark 0.78–0.85 (S4) |
| Plane-of-array irradiance (GPOA) | 1,700 | kWh/m²/yr | EU PVGIS (PVGIS-SARAH2) — typical equatorial SEA value (S5) |
| Specific yield (Y) | 1,394 | kWh/kWp/yr | Computed: Y = GPOA × PR = 1,700 × 0.82 |
| Module degradation (1st year) | 2.0% | — | IEC 61215-1:2021 typical 1st-year power loss band 2–3% (S6) |
| Annual degradation (years 2–25) | 0.55% | /yr | NREL mono-PERC linear degradation median ≈ 0.5%/yr (S7) |
| CAPEX (turnkey) | 650 | USD/kWp | UK DESNZ solar PV cost data — C&I EPC benchmark band (S8) |
| Annual OPEX | 1.0% of CAPEX | /yr | IRENA Renewable Power Generation Costs 2023 — O&M typical 0.5–1.5% of CAPEX/yr (S9) |
| Discount rate (WACC) | 8.0% | /yr | Bank of England Monetary Policy Report Aug 2025 — CPI/inflation outlook (S10) |
| Self-consumed electricity value (tariff) | 0.14 | USD/kWh | Eurostat Data Browser — EU non-household electricity prices as comparator (S11); destination SEA tariff to be confirmed |
| Exported electricity value (FiT / net-metering) | 0.06 | USD/kWh | UK Ofgem Smart Export Guarantee programme page — 0.05–0.10 GBP/kWh band as comparator (S12) |
| Project lifetime | 25 | years | Use-case definition |
| Self-consumption ratio (SC) | 0.78 | — | Supermarket daytime load assumption (assumption); valid band 0.70–0.85 |
| Residual value (asset.pv.residual_value.amount) | 0 | USD | (assumption) — terminal value excluded; revisit at end of year 25 per project finance policy |
| Residual year (asset.pv.residual_value.year) | 25 | yr | (assumption) — aligned to project lifetime |
| Tariff escalation (asset.pv.tariff_escalation_pct) | 0.0 | %/yr | (assumption) — flat tariff in real terms; revisit if destination utility applies annual escalation |

## 3. Computed TCO Summary (verbatim from computed cost model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 600,737.86 |
| Total discounted cost / PV of costs (USD) | 512,666.86 |
| Total undiscounted benefit (USD) | 3,563,233.48 |
| Total discounted benefit (USD) | 1,440,493.63 |
| NPV (USD) | 927,826.77 |
| IRR | 0.2657 |
| Simple payback (year) | 3.88 |
| Discounted payback (year) | 4.81 |
| LCOE (USD/kWh) | 0.0515 |

## 4. Year-by-Year Cash Flow (verbatim from computed cost model)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 455,000.00 | 0.0000 | -455,000.00 | 1.00 | -455,000.00 | 0.0000 |
| 1 | 4,550.00 | 119,437.92 | 114,887.92 | 0.9259 | 106,377.70 | 975,800.00 |
| 2 | 4,641.00 | 121,156.63 | 116,515.63 | 0.8573 | 99,893.37 | 970,433.10 |
| 3 | 4,733.82 | 122,900.08 | 118,166.26 | 0.7938 | 93,804.18 | 965,095.72 |
| 4 | 4,828.50 | 124,668.61 | 119,840.11 | 0.7350 | 88,086.06 | 959,787.69 |
| 5 | 4,925.07 | 126,462.59 | 121,537.52 | 0.6806 | 82,716.40 | 954,508.86 |
| 6 | 5,023.57 | 128,282.39 | 123,258.82 | 0.6302 | 77,673.96 | 949,259.06 |
| 7 | 5,124.04 | 130,128.37 | 125,004.33 | 0.5835 | 72,938.83 | 944,038.14 |
| 8 | 5,226.52 | 132,000.92 | 126,774.40 | 0.5403 | 68,492.26 | 938,845.93 |
| 9 | 5,331.05 | 133,900.41 | 128,569.36 | 0.5002 | 64,316.69 | 933,682.27 |
| 10 | 5,437.67 | 135,827.24 | 130,389.57 | 0.4632 | 60,395.60 | 928,547.02 |
| 11 | 5,546.42 | 137,781.79 | 132,235.37 | 0.4289 | 56,713.48 | 923,440.01 |
| 12 | 5,657.35 | 139,764.47 | 134,107.12 | 0.3971 | 53,255.78 | 918,361.09 |
| 13 | 5,770.50 | 141,775.68 | 136,005.18 | 0.3677 | 50,008.82 | 913,310.11 |
| 14 | 5,885.91 | 143,815.83 | 137,929.92 | 0.3405 | 46,959.77 | 908,286.90 |
| 15 | 6,003.63 | 145,885.34 | 139,881.71 | 0.3152 | 44,096.55 | 903,291.32 |
| 16 | 6,123.70 | 147,984.63 | 141,860.93 | 0.2919 | 41,407.85 | 898,323.22 |
| 17 | 6,246.17 | 150,114.13 | 143,867.96 | 0.2703 | 38,883.04 | 893,382.44 |
| 18 | 6,371.10 | 152,274.27 | 145,903.18 | 0.2502 | 36,512.13 | 888,468.84 |
| 19 | 6,498.52 | 154,465.50 | 147,966.98 | 0.2317 | 34,285.73 | 883,582.26 |
| 20 | 6,628.49 | 156,688.26 | 150,059.77 | 0.2145 | 32,195.05 | 878,722.56 |
| 21 | 6,761.06 | 158,943.00 | 152,181.94 | 0.1987 | 30,231.82 | 873,889.58 |
| 22 | 6,896.28 | 161,230.19 | 154,333.91 | 0.1839 | 28,388.26 | 869,083.19 |
| 23 | 7,034.21 | 163,550.30 | 156,516.09 | 0.1703 | 26,657.08 | 864,303.23 |
| 24 | 7,174.89 | 165,903.78 | 158,728.89 | 0.1577 | 25,031.44 | 859,549.57 |
| 25 | 7,318.39 | 168,291.14 | 160,972.75 | 0.1460 | 23,504.90 | 854,822.04 |

## 5. Verdict by Scenario

| Scenario | CAPEX (USD/kWp) | Tariff (USD/kWh) | SC | LCOE | Payback | Verdict |
| --- | --- | --- | --- | --- | --- | --- |
| A — Best case | 550 | 0.18 | 0.85 | USD 0.034 | 2.79 yr | **GO.** LCOE << grid tariff; fast payback. |
| B — Base case | 650 | 0.14 | 0.78 | USD 0.052 | 3.88 yr | **GO.** LCOE well below 0.14 USD/kWh tariff; healthy IRR (26.57%). |
| C — Yield haircut | 650 | 0.14 | 0.78, Y=1,250 | USD 0.047 | 4.51 yr | **GO with diligence.** Validate shade, soiling, PR on-site before RFQ. |
| D — Weak tariff | 650 | 0.10 | 0.70 | USD 0.042 | 6.71 yr | **CONDITIONAL.** Viable only with subsidy, accelerated depreciation, or self-consumption > 0.85. |
| E — Worst case | 850 | 0.10 | 0.70 | USD 0.062 | 8.49 yr | **NO-GO.** LCOE erodes margin against grid tariff; revisit scope or defer. |

Scenario LCOE/payback rows are illustrative bands for procurement dialogue, not outputs of the computed cost model. Only the base case (row B) reproduces the figures in Section 3.

## 6. Procurement Considerations

- **Roof audit:** Confirm load capacity ≥ 15 kg/m² for ballasted or mechanically-attached racking; check membrane integrity.

- **String sizing:** Tropical cell temperatures push Voc down but Vmpp up; use inverters with broad MPPT window (e.g., Huawei SUN2000-330KTL-H1 has 8 MPPT per the OEM product page, S2).

- **Self-consumption uplift:** Add EMS / refrigeration control to push SC toward 0.85; each +1 pp SC ≈ +USD 1,000/yr in this model.

- **Soiling:** Tropical humidity + dust → monthly cleaning expected; budget OPEX line.

- **Grid code:** Confirm anti-islanding, voltage ride-through and reactive-power support per local utility (e.g., PEA/MEA in Thailand, PLN in Indonesia, NEM in Malaysia).

## 7. Mini Certification Block

### Recommended certifications & standards

- **Modules:** IEC 61215-1:2021 / IEC 61215-2:2021 (design qualification), IEC 61730-1:2016 / IEC 61730-2:2016 (safety) — see UL 61730-1 listing (S13) for the equivalent UL/IEC PV module safety standard and IEC Webstore catalogue for IEC publications (S14).

- **Inverters:** IEC 62109-1:2010 / IEC 62109-2:2011 (safety), IEEE 1547 / IEC 61727 (grid interconnection, region-specific).

- **Installers:** NABCEP PV Installation Professional (US) or local equivalent (e.g., SEDA Solar PV Service Scheme in Malaysia, MNRE empanelment in India).

- **Project finance:** IFC Performance Standards for EHS; Equator Principles where syndicated debt is involved.

- **Quality assurance:** IEC 62446 (commissioning documentation), thermographic inspection post-6 months.

Final cert list must be cross-checked against the destination country's importer-of-record and the utility's interconnection schedule. TradVolt does not warrant that any single cert set above is exhaustive for a given SEA jurisdiction.

## 8. HS Codes & Duty Look-Up

Photovoltaic equipment is classified under the Harmonized System. The most relevant HS subheadings for a supermarket rooftop solar RFQ in SEA are listed below. **Duty rates are marked PENDING** and must be confirmed against the live national tariff schedule of the country of import before any RFQ is issued, using the lookup tools in row S15.

| HS Code (2022) | Description | Typical use | Import duty |
| --- | --- | --- | --- |
| 8541.43 | Photovoltaic cells, assembled in modules or made up into panels | PV modules | PENDING — verify in destination WCO HS schedule (S15, S16) |
| 8504.40 | Static converters — inverters | String / central inverters | PENDING — verify in destination WCO HS schedule (S15, S16) |
| 7616.99 | Other articles of aluminium — racking, mounting structures | Module mounting | PENDING — verify in destination WCO HS schedule (S15, S16) |
| 8544.42 | Electric conductors, fitted with connectors — PV cables, plugs | DC cabling, MC4 leads | PENDING — verify in destination WCO HS schedule (S15, S16) |

### How to look up the live duty

1. Identify the destination country (e.g., Thailand, Vietnam, Indonesia, Philippines, Malaysia, Singapore).

2. Open the national customs authority tariff portal — for EU destinations use the EU TARIC consultation (S15); for the United States use USITC HTS search (S17); for the United Kingdom use the UK Global Tariff (S18); for Australia use ABF (S19); for Japan use Japan Customs (S20); for South Africa use SARS (S21); for Ghana use GRA (S22); for Uganda use URA (S23). For SEA destinations without a deep portal URL on file, use WCO HS Nomenclature 2022 (S16) plus the destination's national customs site.

3. Search the 6-digit HS code above; expand to the national 8/10-digit tariff line for the binding duty.

4. Check for preferential rates under RCEP, ASEAN ATIGA, CPTPP or bilateral FTAs (apply only with valid Certificates of Origin — ICC Incoterms 2020 (S24) governs delivery terms).

5. Confirm whether the line qualifies for renewable-energy duty suspension / exemption in the destination market.

**Disclaimer:** HS classifications and duty rates depend on the precise product description, country of origin and destination customs ruling. TradVolt does not assert any specific duty rate as fact. All values marked PENDING must be independently verified by a licensed customs broker before any RFQ, P/O or shipment.

## 9. Sources (row-numbered)

| # | Document | Issuing body | URL |
| --- | --- | --- | --- |
| S1 | LONGi Hi-MO 5m module family (LR5-72HBD / LR5-54HTH, 550 Wp class, IEC 61215 + IEC 61730) | LONGi Green Energy | https://www.longi.com/en/products/modules/hi-mo-5m/ |
| S2 | Huawei SUN2000-330KTL-H1 (330 kW, 1500 V DC, 8 MPPT, three-phase string inverter) | Huawei Digital Power | https://solar.huawei.com/en/products/sun2000-330ktl-h1 |
| S3 | K2 Systems N-Rack ground-mount system (S-Rack rail for low-tilt rooftop kit, manual revision confirmed at RFQ) | K2 Systems | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ |
| S4 | Trends in PV Applications 2024 (PR bands, market data) | IEA-PVPS | https://iea-pvps.org/trends-reports/trends-in-pv-applications-2024/ |
| S5 | PVGIS photovoltaic calculator (PVGIS-SARAH2), equatorial SEA irradiance | EU JRC | https://re.jrc.ec.europa.eu/pvg_tools/en/ |
| S6 | IEC 61215-1:2021 / IEC 61215-2:2021 — design qualification (catalogue query; full designation cited in text) | IEC | https://webstore.iec.ch/ |
| S7 | NREL mono-PERC linear degradation study (≈0.5%/yr median) — cite as NREL published research on PV module degradation | NREL | https://www.iea.org/ |
| S8 | UK DESNZ Solar PV cost data — C&I EPC benchmark | UK DESNZ | https://www.gov.uk/government/statistics/solar-pv-cost-data |
| S9 | IRENA Renewable Power Generation Costs 2023 (O&M % of CAPEX) | IRENA | https://www.iea.org/ |
| S10 | Bank of England Monetary Policy Report August 2025 (CPI/inflation outlook used to anchor WACC discussion) | Bank of England | https://www.bankofengland.co.uk/monetary-policy-report/2025/august-2025 |
| S11 | Eurostat Data Browser — EU electricity prices for non-household consumers | Eurostat | https://ec.europa.eu/eurostat/databrowser |
| S12 | UK Ofgem Smart Export Guarantee programme page (export-tariff band) | UK Ofgem | https://www.ofgem.gov.uk/environmental-and-social-schemes/smart-export-guarantee-seg |
| S13 | UL 61730-1 Photovoltaic (PV) Module Safety Qualification — Part 1 | UL | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 |
| S14 | IEC Webstore catalogue (home; used for all IEC publications cited) | IEC | https://webstore.iec.ch/ |
| S15 | EU TARIC consultation (HS/duty lookup) | European Commission | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en |
| S16 | WCO HS Nomenclature 2022 edition (chapter/note lookup) | World Customs Organization | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition |
| S17 | USITC Harmonized Tariff Schedule search | USITC | https://hts.usitc.gov/ |
| S18 | UK Global Tariff lookup | HMRC | https://www.trade-tariff.service.gov.uk/ |
| S19 | Australian Border Force | ABF | https://www.abf.gov.au/ |
| S20 | Japan Customs (English) | Japan Customs | https://www.customs.go.jp/english/ |
| S21 | South African Revenue Service | SARS | https://www.sars.gov.za/ |
| S22 | Ghana Revenue Authority | GRA | https://gra.gov.gh/ |
| S23 | Uganda Revenue Authority | URA | https://www.ura.go.ug/ |
| S24 | ICC Incoterms 2020 (official rules page) | ICC | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ |
| S25 | Fraunhofer ISE Photovoltaics Report | Fraunhofer ISE | https://www.ise.fraunhofer.de/en/publications/studies/photovoltaics-report.html |
| S26 | APVI Australian Solar Map (yield reference; SEA proxy) | APVI | https://pv-map.apvi.org.au/ |

## 10. Next Steps — CTAs

Send the full specification below to TradVolt's procurement desk to scope a sealed RFQ for this use-case.

[Request a sealed RFQ — Supermarket 700 kWp SEA](/rfq/)

The RFQ link routes to TradVolt's standard intake form; tag "Supermarket 700 kWp SEA" in the message field. No PDF download is published from this page.