title: "Textile Solar 2 MWp India Use Case & TCO | Tradvolt"
source_url: "https://tradvolt.com/en/tco/textile-solar-2-mwp-india-use-case-tco-tradvolt/"
lang: "en"
description: "Use-case and total-cost-of-ownership analysis for a 2 MWp textile-mill solar installation in India, with sensitivity tables and scenario verdicts."
generator: "tradvolt-tier-c-edge-md"
---

[TradVolt](https://tradvolt.com) &rsaquo; [Use Cases](https://tradvolt.com/use-cases/) &rsaquo; Textile Solar 2 MWp India

# Textile Solar 2 MWp in India — Use Case & Total Cost of Ownership

## Verdict (read first)

**Answer:** NPV **INR 168,846,062** (positive); discounted payback **2.19 years**; simple payback **1.86 years**; LCOE **2.20 INR/kWh**; IRR **55.55%**. Equipment scope: 2 MWp DC rooftop + captive-ground-mount hybrid PV plant (crystalline-silicon modules, string inverters, aluminium mounting). Location: textile spinning/weaving cluster, India. Horizon: 25 years. Evidence date: 2026-02-15. Limitation: figures are scenario-bound and computed only within the computed cash flow; tariff escalation, capex, and yield assumptions are stated below and any change materially shifts NPV.

Decision table | Indicator | Value | Unit |
| --- | --- | --- |
| NPV | 168,846,062 | INR |
| IRR | 55.55 | % |
| Simple payback | 1.86 | years |
| Discounted payback | 2.19 | years |
| LCOE | 2.20 | INR/kWh |
| Discount rate | 11.00 | %/yr |
| Horizon | 25 | years |

## 1. Use-Case Profile

A 2 MWp DC rooftop and captive-ground-mount hybrid solar PV system serving a textile spinning and weaving cluster in India. The plant offsets grid electricity consumed by ring frames, winding machines, humidification plant, and lighting loads.

## 2. Equipment Identification

| Item | Model / family (named for RFQ scoping) | Public product page | OEM manual revision |
| --- | --- | --- | --- |
| PV module (LONGi) | LONGi Hi-MO 9 (back-contact HPBC 2.0, up to 670 W, up to 24.8% efficiency; bifaciality up to 80%) | https://www.longi.com/en/products/modules/hi-mo-9/ | PENDING — datasheet rev locked at RFQ; look up trail dated 2026-02-15 |
| PV module (Jinko) | Jinko Solar Tiger Neo 3.0 N-type (JKM650-670N-66QL6-BDV-F1-EN) | https://jinkosolarcdn.shwebspace.com/uploads/Tiger%20Neo%203.0%20Flyer.pdf | PENDING — datasheet rev locked at RFQ; look up trail dated 2026-02-15 |
| PV module (alternate) | Canadian Solar TopHiKu6 (up to 620 W, up to 23.0%) | https://www.canadiansolar.com/na/tophiku6/ | PENDING — datasheet rev locked at RFQ; look up trail dated 2026-02-15 |
| String inverter (Sungrow) | Sungrow SG125HT C&I 3-phase string inverter | https://www.sungrowpower.com/en/products/string-inverter | PENDING — user-manual rev locked at RFQ; look up trail dated 2026-02-15 |
| String inverter (Huawei) | Huawei SUN2000-330KTL-H1 (300 kW class) — FusionSolar | https://solar.huawei.com/en | PENDING — user-manual rev locked at RFQ; look up trail dated 2026-02-15 |
| String inverter (SMA, alt.) | SMA Sunny Tripower CORE1 (33-US / 50-US / 62-US; 6 MPP trackers; 150-1000 V) | https://www.sma-america.com/products/solarinverters/sunny-tripower-core1 | PENDING — user-manual rev locked at RFQ; look up trail dated 2026-02-15 |
| Mounting structure | K2 Systems S-Dome 6 (aluminium rail system for trapezoidal/flat roofs) | https://k2-systems.com/en/ | PENDING — installation-manual rev locked at RFQ; look up trail dated 2026-02-15 |
| Mounting alt. | K2 Systems N-Rack ground-mount system (driven-pile) | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ | PENDING — installation-manual rev locked at RFQ; look up trail dated 2026-02-15 |

Exact BOM, OEM manual revision, torque values, max system voltage, and SOC limits (if BESS added later) are locked at the RFQ stage against the chosen supplier's datasheet pack.

## 3. TCO Inputs (Scenario-Bound)

| Parameter | Value | Unit | Source |
| --- | --- | --- | --- |
| Plant capacity (DC) | 2.0 | MWp | Use-case scope (TradVolt) |
| Specific yield (year 1) | 1,450 | kWh/kWp/yr | Model assumption (state-weighted, MNRE Solar Energy Statistics 2023 narrative) |
| Module cost | 9.50 | INR/Wp | Model assumption (consistent with recent Indian C&I pricing reports) |
| Inverter cost | 1.20 | INR/Wp | Model assumption |
| Balance-of-System | 4.80 | INR/Wp | Model assumption |
| EPC + civil | 3.00 | INR/Wp | Model assumption |
| Developer overhead | 1.00 | INR/Wp | Model assumption |
| Annual O&M | 0.45 | INR/Wp/yr | Model assumption |
| Insurance | 0.05 | INR/Wp/yr | Model assumption |
| Inverter replacement (year 12) | 0.60 | INR/Wp | Model assumption (nominal; cash flow uses escalated figure) |
| Module degradation | 0.50 | %/yr | Model assumption (linear) |
| Tariff (grid import avoidance) | 7.50 | INR/kWh | Model assumption (CEA industrial narrative) |
| Tariff escalation | 3.00 | %/yr | Model assumption |
| O&M escalation | 5.00 | %/yr | Model assumption |
| Discount rate (WACC) | 11.00 | %/yr | Model assumption |
| Analysis horizon | 25 | years | Use-case scope |
| Residual value (asset end of horizon) | 0 | INR | Model assumption (bounded default; ZERO-AS-MISSING) |
| Self-consumption share | 100 | % | Model assumption (captive textile-mill load; bounded default) |
| Export tariff (excess export) | 0 | INR/kWh | Model assumption (no export credit; bounded default ZERO-AS-MISSING) |

*All inputs above are scenario-bound assumptions, not sourced market facts. Only the computed numbers in the COMPUTED TABLES below are computed.*

## 4. TCO Summary (computed)

TCO summary | Metric | Value |
| --- | --- |
| Currency | INR |
| Horizon (years) | 25 |
| Discount rate | 11.00 % |
| Total undiscounted cost (INR) | 87,927,098.82 |
| Total discounted cost / PV of costs (INR) | 51,855,290.51 |
| Total undiscounted benefit (INR) | 741,489,686.31 |
| Total discounted benefit (INR) | 220,701,352.02 |
| NPV (INR) | 168,846,061.51 |
| IRR | 0.5555 |
| Simple payback (year) | 1.86 |
| Discounted payback (year) | 2.19 |
| LCOE (INR/kWh) | 2.20 |

## 5. Year-by-Year Cash Flow (computed)

Year-by-year cash flow | Year | Cost (INR) | Benefit (INR) | Net (INR) | Discount factor | Discounted net (INR) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 39,000,000.00 | 0.0000 | -39,000,000.00 | 1.00 | -39,000,000.00 | 0.0000 |
| 1 | 1,000,000.00 | 21,750,000.00 | 20,750,000.00 | 0.9009 | 18,693,693.69 | 2,900,000.00 |
| 2 | 1,050,000.00 | 22,290,487.50 | 21,240,487.50 | 0.8116 | 17,239,256.15 | 2,885,500.00 |
| 3 | 1,102,500.00 | 22,844,406.11 | 21,741,906.11 | 0.7312 | 15,897,494.36 | 2,871,072.50 |
| 4 | 1,157,625.00 | 23,412,089.61 | 22,254,464.61 | 0.6587 | 14,659,705.15 | 2,856,717.14 |
| 5 | 1,215,506.25 | 23,993,880.03 | 22,778,373.78 | 0.5935 | 13,517,856.17 | 2,842,433.55 |
| 6 | 1,276,281.56 | 24,590,127.95 | 23,313,846.39 | 0.5346 | 12,464,534.33 | 2,828,221.38 |
| 7 | 1,340,095.64 | 25,201,192.63 | 23,861,096.99 | 0.4817 | 11,492,898.06 | 2,814,080.28 |
| 8 | 1,407,100.42 | 25,827,442.27 | 24,420,341.85 | 0.4339 | 10,596,633.38 | 2,800,009.88 |
| 9 | 1,477,455.44 | 26,469,254.21 | 24,991,798.76 | 0.3909 | 9,769,913.22 | 2,786,009.83 |
| 10 | 1,551,328.22 | 27,127,015.18 | 25,575,686.96 | 0.3522 | 9,007,359.98 | 2,772,079.78 |
| 11 | 1,628,894.63 | 27,801,121.50 | 26,172,226.88 | 0.3173 | 8,304,010.88 | 2,758,219.38 |
| 12 | 2,910,339.36 | 28,491,979.37 | 25,581,640.01 | 0.2858 | 7,312,277.05 | 2,744,428.28 |
| 13 | 1,795,856.33 | 29,200,005.06 | 27,404,148.73 | 0.2575 | 7,056,958.96 | 2,730,706.14 |
| 14 | 1,885,649.14 | 29,925,625.19 | 28,039,976.04 | 0.2320 | 6,505,129.33 | 2,717,052.61 |
| 15 | 1,979,931.60 | 30,669,276.97 | 28,689,345.37 | 0.2090 | 5,996,197.89 | 2,703,467.35 |
| 16 | 2,078,928.18 | 31,431,408.50 | 29,352,480.32 | 0.1883 | 5,526,843.22 | 2,689,950.01 |
| 17 | 2,182,874.59 | 32,212,479.01 | 30,029,604.42 | 0.1696 | 5,094,000.37 | 2,676,500.26 |
| 18 | 2,292,018.32 | 33,012,959.11 | 30,720,940.79 | 0.1528 | 4,694,841.05 | 2,663,117.76 |
| 19 | 2,406,619.23 | 33,833,331.14 | 31,426,711.91 | 0.1377 | 4,326,755.43 | 2,649,802.17 |
| 20 | 2,526,950.20 | 34,674,089.42 | 32,147,139.23 | 0.1240 | 3,987,335.28 | 2,636,553.16 |
| 21 | 2,653,297.71 | 35,535,740.54 | 32,882,442.84 | 0.1117 | 3,674,358.43 | 2,623,370.39 |
| 22 | 2,785,962.59 | 36,418,803.70 | 33,632,841.11 | 0.1007 | 3,385,774.44 | 2,610,253.54 |
| 23 | 2,925,260.72 | 37,323,810.97 | 34,398,550.25 | 0.0907 | 3,119,691.34 | 2,597,202.27 |
| 24 | 3,071,523.76 | 38,251,307.67 | 35,179,783.91 | 0.0817 | 2,874,363.42 | 2,584,216.26 |
| 25 | 3,225,099.94 | 39,201,852.67 | 35,976,752.72 | 0.0736 | 2,648,179.94 | 2,571,295.18 |

All values in INR except where labelled. Discount rate is per year; tariff escalation and opex escalation are per year. PV of costs = INR 51,855,290.51; PV of benefits = INR 220,701,352.02; NPV = PV(benefits) &minus; PV(costs) = INR 168,846,061.51.

Download the year-by-year cash flow (CSV)

## 6. Compliance & Standards Reference

| Domain | Standard / scheme | Reference URL | Status |
| --- | --- | --- | --- |
| PV module safety qualification (c-Si) | IEC 61215-1:2021 ed2 — Terrestrial photovoltaic (PV) modules — Design qualification and type approval — Part 1: Test requirements (TC 82) | https://webstore.iec.ch/en/publication/61345 | PENDING — confirm supplier test certificate |
| PV module safety qualification (c-Si, special) | IEC 61215-1-1:2021 — Special requirements for c-Si modules (TC 82) | https://webstore.iec.ch/en/publication/61346 | PENDING — confirm supplier test certificate |
| PV module safety qualification | UL 61730-1 — Photovoltaic (PV) Module Safety Qualification — Part 1 | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 | PENDING — confirm supplier test certificate |
| PCE (inverter) safety — general | IEC 62109-1:2010 — Safety of power converters for use in photovoltaic power systems — Part 1: General requirements (TC 82) | https://webstore.iec.ch/en/publication/6470 | PENDING — confirm supplier test certificate |
| PCE (inverter) safety — inverter particular | IEC 62109-2:2011 — Safety of power converters for use in photovoltaic power systems — Part 2: Particular requirements for inverters (use jointly with IEC 62109-1) (TC 82) | https://webstore.iec.ch/en/publication/6471 | PENDING — confirm supplier test certificate |
| Module & inverter standards catalogue | IEC Webstore (catalogue for IEC 61215, IEC 61730, IEC 62109, and related) | https://webstore.iec.ch/ | PENDING — confirm supplier test certificate |
| BoS / module quality order (India) | MNRE Approved List of Models and Manufacturers (ALMM) — India | https://almm.ureda.com.in/ (official ALMM portal; full listing PDF confirmed at RFQ) | PENDING — confirm ALMM listing |
| EHS (EPC contractor) | ISO 45001 (search via ISO catalogue) | https://www.iso.org/search.html?q=2859 | PENDING — confirm audit certificate |
| HS / duty lookup (India import) | Indian Customs ICEGATE — Tariff / ITC-HS chapter search | https://www.icegate.gov.in/ | PENDING — confirm applicable BCD/IGST notification (HS 8541.40) |
| HS / duty lookup (India customs parent) | Central Board of Indirect Taxes and Customs (CBIC) | https://www.cbic.gov.in/ | PENDING — confirm applicable BCD/IGST notification |

Standard designations above are cited verbatim with edition or scheme name. Where a deep document URL is gated (e.g., ALMM listing PDF, ICEGATE chapter PDF), the portal home is cited and the exact document is confirmed at RFQ stage.

## 7. Logistics & Trade Reference

| Topic | Reference | URL |
| --- | --- | --- |
| Incoterms (delivery terms) | ICC Incoterms 2020 | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ |
| Lithium battery transport (UN 38.3) | UN Manual of Tests and Criteria (ST/SG/AC.10/11/Rev.7) | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria |
| Wood packaging (ISPM 15) | IPPC ISPMs (incl. ISPM 15) | https://www.ippc.int/en/core-activities/standards-setting/ispms/ |
| Air freight (DG rules for Li-ion) | IATA Dangerous Goods Regulations | https://www.iata.org/en/programs/cargo/dgr/ |
| Sea freight documentation | FIATA freight forwarding documents | https://fiata.org/ |

## 8. Sources Table

| Topic | Reference | URL | Use on this page |
| --- | --- | --- | --- |
| EU Battery Regulation (if BESS added later) | Regulation (EU) 2023/1542 | https://eur-lex.europa.eu/eli/reg/2023/1542/oj | Reference only (this scope is PV-only) |
| EU duty / HS lookup | European Commission TARIC consultation | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en | Reference only (export-route HS) |
| US duty / HS lookup | USITC Harmonized Tariff Schedule | https://hts.usitc.gov/ | Reference only (export-route HS) |
| UK duty lookup | UK Global Tariff | https://www.trade-tariff.service.gov.uk/ | Reference only |
| Japan duty lookup | Japan Customs (English) | https://www.customs.go.jp/english/ | Reference only |
| Australia duty lookup | Australian Border Force — Tariff classification — Current tariff | https://www.abf.gov.au/importing-exporting-and-manufacturing/tariff-classification/current-tariff | Reference only |
| South Africa duty lookup | South African Revenue Service — Customs and Excise Tariff | https://www.sars.gov.za/customs-and-excise/tariff/ | Reference only |
| Ghana duty lookup | Ghana Revenue Authority | https://gra.gov.gh/ | Reference only |
| Uganda duty lookup | Uganda Revenue Authority | https://www.ura.go.ug/ | Reference only |
| US trade & CBP | US Customs and Border Protection | https://www.cbp.gov/ | Reference only |
| US trade promotion | US International Trade Administration | https://www.trade.gov/ | Reference only |
| Market data (general) | International Energy Agency | https://www.iea.org/ | Reference only |
| EV charging protocol (if e-mobility added later) | Open Charge Alliance (OCPP) | https://www.openchargealliance.org/ | Reference only (out of scope) |
| PV module OEM (LONGi) | LONGi Green Energy Technology Co., Ltd. — Hi-MO 9 product page | https://www.longi.com/en/products/modules/hi-mo-9/ | Equipment identification |
| PV module OEM (Jinko) | JinkoSolar Tiger Neo 3.0 datasheet (PDF) | https://jinkosolarcdn.shwebspace.com/uploads/Tiger%20Neo%203.0%20Flyer.pdf | Equipment identification |
| PV module OEM (Trina) | Trina Solar product catalogue | https://www.trinasolar.com/us-en | Equipment identification (alternate) |
| PV module OEM (Canadian Solar) | Canadian Solar TopHiKu6 | https://www.canadiansolar.com/na/tophiku6/ | Equipment identification (alternate) |
| String inverter OEM (Sungrow) | Sungrow string inverter range | https://www.sungrowpower.com/en/products/string-inverter | Equipment identification |
| String inverter OEM (Huawei) | Huawei FusionSolar | https://solar.huawei.com/en | Equipment identification |
| String inverter OEM (SMA, alt.) | SMA Sunny Tripower CORE1 | https://www.sma-america.com/products/solarinverters/sunny-tripower-core1 | Equipment identification (alternate) |
| String inverter OEM (Growatt) | Growatt product catalogue | https://www.growatt.com/ | Equipment identification (alternate) |
| Mounting OEM (K2 Systems) | K2 Systems S-Dome / N-Rack product range | https://k2-systems.com/en/ | Equipment identification |
| Mounting OEM (K2 Systems ground mount) | K2 Systems N-Rack ground-mount system | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ | Equipment identification (ground-mount) |
| EV-conductive charging standard (not in scope) | IEC 61851-1:2017 — Electric vehicle conductive charging system, Part 1: General requirements (TC 69) | https://webstore.iec.ch/en/publication/33644 | Reference only |
| Stationary battery standard (not in scope) | UL 1973 — Batteries for Use in Stationary and Motive Auxiliary Power Applications | https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973 | Reference only |
| PV module safety (UL) | UL 61730-1 — Photovoltaic (PV) Module Safety Qualification — Part 1 | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 | Standards reference |
| PV module qualification (IEC) | IEC 61215-1:2021 ed2 — Terrestrial PV modules, design qualification and type approval, Part 1: Test requirements (TC 82) | https://webstore.iec.ch/en/publication/61345 | Standards reference |
| PCE (inverter) safety (IEC) | IEC 62109-1:2010 — Safety of power converters for use in PV power systems, Part 1: General requirements (TC 82) | https://webstore.iec.ch/en/publication/6470 | Standards reference |

All other named organisations in this page (MNRE Solar Energy Statistics 2023, CEA industrial-demand narrative, RBI CPI/WACC narrative, ALMM portal) are referenced for context only; the computed financial figures in Sections 4 and 5 do not depend on any single named statistic.

## 9. Call to Action

[Request a quotation (RFQ) for a 2 MWp textile-mill solar project in India](/rfq/)

After submitting the RFQ, a TradVolt sourcing specialist will lock the OEM model, manual revision, torque/SOC/voltage limits, ALMM status, and applicable HS-code duty rate (via [Indian Customs ICEGATE](https://www.icegate.gov.in/) and [CBIC](https://www.cbic.gov.in/)) before purchase order release.

Supporting asset: textile-solar-2mwp-in-r9-tco-200.csv (year-by-year cash flow).