# Use-Case & TCO: 150 kWp Solar PV for Botanical Gardens in the US (Reference Design r9)

## Answer-first summary

**Verdict (decide):** Proceed at Base inputs over a 25-year horizon. **Equipment:** 150 kWp DC grid-connected photovoltaic (PV) system using Jinko Solar Tiger Neo 3.0 modules and Sungrow SG125HV string inverters, on vendor-neutral roof/carport mounting. **Location:** United States, botanical garden site (reference design, site-agnostic irradiation band). **Horizon:** 25 years. **Evidence date:** 2026-01-15. **Key figures (scenario model):** NPV = USD 29,899.42; Simple payback = 11.81 yr; Discounted payback = 21.68 yr; LCOE = USD 0.1695 / kWh; IRR = 7.85 %. **Limitation:** Reference design only; no structural, single-line, AHJ, shading, or storage work; override WACC and yield with site-specific computed values before procurement.

Decision table — computed TCO summary (Base case, computed) | Metric | Value |
| --- | --- |
| Net Present Value (NPV) | USD 29,899.42 |
| Internal Rate of Return (IRR) | 7.85 % |
| Simple payback | 11.806443565159412 yr |
| Discounted payback | 21.682237989675443 yr |
| Levelized Cost of Electricity (LCOE) | USD 0.1695 / kWh |
| Total undiscounted cost | USD 405,000.00 |
| Total discounted cost (PV of costs) | USD 368,964.67 |
| Total undiscounted benefit | USD 930,697.40 |
| Total discounted benefit (PV of benefits) | USD 398,864.09 |

## 1. Scope and intended reader

This reference design models a grid-connected, roof- or carport-mounted photovoltaic system sized at 150 kWp (DC) installed at a botanical garden in the United States. The intended readers are B2B procurement managers, facilities engineers, sustainability officers, and EPC contractors evaluating greenfield solar procurement for horticultural, educational, and visitor-center facilities.

All headline numbers on this page are copied verbatim from the project's scenario model. The two computed tables below (TCO summary and Year-by-year cash flow) are the only mathematics in the page; everything else is inputs, assumption labels, equipment references, and procurement guidance.

## 2. Reference equipment

The reference design uses the following real, publicly marketed equipment families. Cite-by-reference only; full datasheet must be confirmed against the OEM manual at RFQ stage.

| Item | Model family | Source |
| --- | --- | --- |
| PV module | Jinko Solar Tiger Neo 3.0 (N-type TOPCon, family JKM-N-66QL6-BDV; STC output up to 670 Wp per JinkoSolar Tiger Neo 3.0 flyer; model page https://www.jinkosolar.com/en/site/tigerneo_3) | Tiger Neo 3.0 flyer (PDF); JinkoSolar Tiger Neo 3.0 product page |
| String inverter | Sungrow SG125HV (125 kW, 1500 V DC, C&I 3-phase string inverter family) — see Sungrow SG125HV product page and the Sungrow string-inverter range page | https://en.sungrowpower.com/Product-SG125HV.html; https://www.sungrowpower.com/en/products/string-inverter |
| Mounting | Ballasted or penetrating rooftop/carport mounting; reference: K2 Systems CrossRail System (or K2 SingleRail 36) — vendor-neutral reference; site-specific selection by EPC | https://k2-systems.com/en-us/product-solutions/crossrail-system/ |

## 3. Inputs table

| Input | Symbol | Value (Base) | Source / classification |
| --- | --- | --- | --- |
| System size (DC) | P | 150 kWp | Reference design r9 brief (assumption) |
| Specific annual yield | Y | 1,300 kWh/kWp/yr | Reference-design band; verify with EC JRC PVGIS or NREL PVWatts at RFQ stage |
| Capex per Wp (installed) | C | USD 2.25 / Wp | NREL/TP-7A40-87810 — U.S. Solar PV and Storage Cost Benchmarks (Q1 2024 indicator) |
| Annual O&M per kWp | O | USD 18 / kWp/yr | NREL/TP-7A40-80686 — PV O&M Costs |
| Effective avoided-cost rate (grid import displaced) | p | USD 0.14 / kWh (model input) — derived from computed Year-1 benefit of USD 27,300 / 195,000 kWh. The USD 0.14 / kWh figure is the latest EIA all-sector retail band (EIA Electric Power Monthly Table 5.6.A) and is the rate applied in this model. | EIA Electric Power Monthly Table 5.6.A — retail band applied as this model's avoided-cost rate |
| Annual electricity price escalator | e | 3.0 % / yr | EIA Annual Energy Outlook 2024 — commercial electricity price CAGR projection band |
| Discount rate (project WACC proxy) | r | 7.0 % / yr | tradvolt.com reference-design assumption; override with project WACC |
| Project horizon | N | 25 yr | NREL Standard Scenarios / EIA cost-and-performance convention |
| Annual module degradation | d | 0.5 % / yr | NREL/TP-5J00-72155 — Jordan & Kurtz PV degradation meta-analysis |
| Self-consumption share of generation | — | 100 % (model assumption; all generation displaces grid imports at p) | Model assumption (bounded): asset.pv.self_consumption_pct = 100 |
| Export tariff (if any) | — | USD 0.00 / kWh (model assumption; no export revenue) | Model assumption (bounded): asset.pv.export_tariff_per_kwh = 0 (ZERO-AS-MISSING) |
| Residual value | — | USD 0 at year 25 (model assumption) | Model assumption (bounded): residual_value.amount = 0; residual_value.year = 25 |
| Inverter replacement in horizon | — | None modeled in Base; replacement cost line item omitted | Model assumption (bounded): replacements[0].amount = DROPPED-ITEM |

The scenario model is consistent internally: with input p = USD 0.14/kWh at r = 7.0 % / yr over N = 25 yr, the cashflow table below reproduces the scenario TCO summary exactly. The USD 0.14/kWh figure from [EIA Table 5.6.A](https://www.eia.gov/electricity/monthly/epm_table_5_06_a.html) is reported as a retail-band reference only and is not a model input.

## 4. Computed TCO summary (computed)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 7.00 % |
| Total undiscounted cost (USD) | 405,000.00 |
| Total discounted cost / PV of costs (USD) | 368,964.67 |
| Total undiscounted benefit (USD) | 930,697.40 |
| Total discounted benefit (USD) | 398,864.09 |
| NPV (USD) | 29,899.42 |
| IRR | 0.0785 |
| Simple payback (year) | 11.81 |
| Discounted payback (year) | 21.68 |
| LCOE (USD/kWh) | 0.1695 |

## 5. Year-by-year cash flow (computed)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 337,500.00 | 0.0000 | -337,500.00 | 1.00 | -337,500.00 | 0.0000 |
| 1 | 2,700.00 | 27,300.00 | 24,600.00 | 0.9346 | 22,990.65 | 195,000.00 |
| 2 | 2,700.00 | 27,978.41 | 25,278.41 | 0.8734 | 22,079.14 | 194,025.00 |
| 3 | 2,700.00 | 28,673.67 | 25,973.67 | 0.8163 | 21,202.25 | 193,054.88 |
| 4 | 2,700.00 | 29,386.21 | 26,686.21 | 0.7629 | 20,358.78 | 192,089.60 |
| 5 | 2,700.00 | 30,116.46 | 27,416.46 | 0.7130 | 19,547.55 | 191,129.15 |
| 6 | 2,700.00 | 30,864.85 | 28,164.85 | 0.6663 | 18,767.43 | 190,173.51 |
| 7 | 2,700.00 | 31,631.84 | 28,931.84 | 0.6227 | 18,017.30 | 189,222.64 |
| 8 | 2,700.00 | 32,417.89 | 29,717.89 | 0.5820 | 17,296.08 | 188,276.53 |
| 9 | 2,700.00 | 33,223.48 | 30,523.48 | 0.5439 | 16,602.75 | 187,335.14 |
| 10 | 2,700.00 | 34,049.08 | 31,349.08 | 0.5083 | 15,936.28 | 186,398.47 |
| 11 | 2,700.00 | 34,895.20 | 32,195.20 | 0.4751 | 15,295.71 | 185,466.48 |
| 12 | 2,700.00 | 35,762.35 | 33,062.35 | 0.4440 | 14,680.08 | 184,539.14 |
| 13 | 2,700.00 | 36,651.04 | 33,951.04 | 0.4150 | 14,088.47 | 183,616.45 |
| 14 | 2,700.00 | 37,561.82 | 34,861.82 | 0.3878 | 13,520.01 | 182,698.37 |
| 15 | 2,700.00 | 38,495.23 | 35,795.23 | 0.3624 | 12,973.84 | 181,784.87 |
| 16 | 2,700.00 | 39,451.84 | 36,751.84 | 0.3387 | 12,449.12 | 180,875.95 |
| 17 | 2,700.00 | 40,432.22 | 37,732.22 | 0.3166 | 11,945.05 | 179,971.57 |
| 18 | 2,700.00 | 41,436.96 | 38,736.96 | 0.2959 | 11,460.87 | 179,071.71 |
| 19 | 2,700.00 | 42,466.66 | 39,766.66 | 0.2765 | 10,995.81 | 178,176.35 |
| 20 | 2,700.00 | 43,521.96 | 40,821.96 | 0.2584 | 10,549.17 | 177,285.47 |
| 21 | 2,700.00 | 44,603.48 | 41,903.48 | 0.2415 | 10,120.24 | 176,399.04 |
| 22 | 2,700.00 | 45,711.88 | 43,011.88 | 0.2257 | 9,708.35 | 175,517.05 |
| 23 | 2,700.00 | 46,847.82 | 44,147.82 | 0.2109 | 9,312.84 | 174,639.46 |
| 24 | 2,700.00 | 48,011.99 | 45,311.99 | 0.1971 | 8,933.10 | 173,766.27 |
| 25 | 2,700.00 | 49,205.08 | 46,505.08 | 0.1842 | 8,568.52 | 172,897.43 |

Discount factors shown use (1+r)-(t-1) with r = 7 %; the table convention labels the Year-1 factor as 0.9346 in line with the scenario model.

## 6. Procurement guidance (model inputs reassigned)

The scenario model fixes the avoided-cost rate at USD 0.14/kWh (Year-1 benefit of USD 27,300 on 195,000 kWh of Year-1 generation). For procurement, override this with a site-specific avoided-cost study, the local utility tariff, and any net-metering/PV-export compensation at the point of interconnection. EIA's retail-band reference of USD 0.14/kWh ([EIA Table 5.6.A](https://www.eia.gov/electricity/monthly/epm_table_5_06_a.html)) and Ofgem's retail-market indicators ([Ofgem retail market indicators](https://www.ofgem.gov.uk/energy-data-and-research/data-portal/retail-market-indicators)) may be used as cross-checks at RFQ stage but do not replace a tariff-class-specific avoided-cost rate.

## 7. Call to action

Request a binding RFQ for a 150 kWp botanical-garden solar PV reference design at [tradvolt.com/rfq/](/rfq/). (Logged-in supplier accounts receive a sealed PDF datasheet pack by return email.)

## 8. Certification block (third-party)

| Equipment safety certification | UL LLC (UL 61730-1 PV modules; UL 1741 inverters) — see UL solar PV services for the certification scheme and certificate registry. Module safety standard: UL 61730-1. |
| --- | --- |
| Standards basis (PV modules) | IEC 61215-1:2021 ed2 (terrestrial PV modules — design qualification, Part 1: test requirements, TC 82) and IEC 61215-1-1:2021 (c-Si special requirements, TC 82). See IEC Webstore catalogue. |
| Standards basis (inverters) | IEC 62109-1:2010 (safety of power converters for use in PV power systems — general requirements, TC 82) and IEC 62109-2:2011 (particular requirements for inverters, TC 82). |
| Model version | r9 |
| Issue date | 2026-01-15 |
| Scope | Use-case and TCO for 150 kWp rooftop/carport solar PV at a US botanical garden; reference design only |
| Out of scope | Structural load calculations, electrical single-line diagrams, permit-specific AHJ coordination, detailed shading analysis, battery storage sizing |

## 9. Harmonized System code block

| HS / HTS code | Description | How to look up US import duty |
| --- | --- | --- |
| 8541.43 | Photovoltaic cells, assembled in modules or made up into panels | Look up General, Special, and Column 2 rates at USITC HTS — heading 8541.43. Verify any Section 201 / 232 / 301 measures at the time of importation. |
| 8541.40 | Photovoltaic cells, not assembled in modules or made up into panels | Look up at USITC HTS — heading 8541.40. |
| 8504.40 | Static converters (inverters for PV) | Look up at USITC HTS — heading 8504.40. |
| 8537.10 | Boards, panels, consoles for electric control/distribution | Look up at USITC HTS — heading 8537.10. |

For EU imports, look up the CN heading and any measures at [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en). For UK imports, use [UK Global Tariff lookup](https://www.trade-tariff.service.gov.uk/). Duty rates are not asserted as facts in this document; verify at the time of importation and account for any Section 201, 232, 301, EU CBAM, anti-dumping or safeguard measures.

## 10. Provenance and audit trail

- [JinkoSolar Tiger Neo 3.0 flyer (PDF)](https://jinkosolarcdn.shwebspace.com/uploads/Tiger%20Neo%203.0%20Flyer.pdf) — module family and STC output range.

- [JinkoSolar Tiger Neo 3.0 product page](https://www.jinkosolar.com/en/site/tigerneo_3) — module family landing.

- [Sungrow SG125HV product page](https://en.sungrowpower.com/Product-SG125HV.html) — reference inverter family.

- [Sungrow string-inverter range page](https://www.sungrowpower.com/en/products/string-inverter) — reference inverter family.

- [K2 Systems CrossRail System (US)](https://k2-systems.com/en-us/product-solutions/crossrail-system/) — mounting reference.

- [NREL PVWatts](https://pvwatts.nrel.gov/) — reference for US-average specific annual yield band.

- [EC JRC PVGIS](https://joint-research-centre.ec.europa.eu/photovoltaic-geographical-information-system-pvgis_en) — site-specific yield lookup.

- [NREL/TP-7A40-87810 — U.S. Solar PV and Storage Cost Benchmarks](https://www.nrel.gov/docs/fy24osti/87810.pdf) — capex per Wp.

- [NREL/TP-7A40-80686 — PV O&M Costs](https://www.nrel.gov/docs/fy22osti/80686.pdf).

- [EIA Electric Power Monthly, Table 5.6.A](https://www.eia.gov/electricity/monthly/epm_table_5_06_a.html) — retail band applied as this model's avoided-cost rate.

- [EIA Annual Energy Outlook 2024](https://www.eia.gov/outlooks/aeo/) — electricity price CAGR band.

- [NREL/TP-5J00-72155 — PV degradation meta-analysis (Jordan & Kurtz)](https://www.nrel.gov/docs/fy19osti/72155.pdf).

- [Ofgem retail-market indicators](https://www.ofgem.gov.uk/energy-data-and-research/data-portal/retail-market-indicators) — UK retail tariff series for cross-check.

- [UL solar PV certification services](https://www.ul.com/services/solar-photovoltaic-services).

- [UL 61730-1 product page](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1).

- [IEC 61215-1:2021 ed2 (TC 82)](https://webstore.iec.ch/en/publication/61345).

- [IEC 61215-1-1:2021 (TC 82)](https://webstore.iec.ch/en/publication/61346).

- [IEC 62109-1:2010 (TC 82)](https://webstore.iec.ch/en/publication/6470).

- [IEC 62109-2:2011 (TC 82)](https://webstore.iec.ch/en/publication/6471).

- [USITC Harmonized Tariff Schedule](https://hts.usitc.gov/) — HS / HTS classification lookup.

- [EU TARIC consultation](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en) — CN duty and measures lookup.

- [UK Global Tariff lookup](https://www.trade-tariff.service.gov.uk/).

Internal assumptions (not source-asserted; bounded defaults from the model): discount rate 7 %, project horizon 25 yr, self-consumption 100 %, export tariff 0 (ZERO-AS-MISSING), residual value 0 at year 25, no inverter replacement in horizon, effective avoided-cost rate USD 0.14/kWh. Override all of the above with project-specific computed values before procurement.