---
title: "Use Case & TCO: 80 kWp Gym Rooftop Solar in the US (r9) | Tradvolt"
source_url: "https://tradvolt.com/en/tco/use-case-tco-80-kwp-gym-rooftop-solar-in-the-us-r9-tradvolt/"
lang: "en"
description: "Worked TCO model for an 80 kWp rooftop PV system on a US commercial gym. Vendor-neutral inputs cited, transparent formula, sensitivity, HS code lookup block, and RFQ anchor."
generator: "tradvolt-tier-c-edge-md"
---

[TradVolt](https://tradvolt.com/) &rsaquo; [Use Cases](https://tradvolt.com/use-cases/) &rsaquo; Gym Solar 80 kWp US (r9)

**Verdict (base case, US commercial gym, 80 kWp rooftop PV, 25-year horizon, evidence date 2026-01-15):** Simple payback (undiscounted) = 14.41 years; discounted payback at r = 7.00% = none within the 25-year horizon; NPV @7.00% over 25 years = USD -30,626.50; LCOE = USD 0.1628/kWh. The base case is NPV-negative at the 7% discount rate over 25 years; the project only returns capital within the analysis window on an undiscounted basis. Limitation: vendor-neutral inputs; replace with site-specific yield, tariff, and capex for procurement.

Decision table | Scenario | Capex (USD) | Yield (kWh/kWp/yr) | S (self-use) | T (USD/kWh) | Simple payback (yr, undisc.) | Discounted payback (yr, r=7%) | NPV @7% over 25 yr (USD) | Verdict |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Base case (no ITC) | 184,000 | 1,400 | 0.70 | 0.14 | 14.41 | None (within 25 yr) | -30,626.50 | NPV-negative at 7%; revisit tariff, self-use, or capex. |
| Base case + 30% ITC | 128,800 | 1,400 | 0.70 | 0.14 | (see text) | (see text) | (see text) | Apply ITC only if tax appetite exists; verify eligibility with a tax advisor. |

# Use Case & TCO: 80 kWp Gym Rooftop Solar in the United States (Revision 9)

A commercial gym is an attractive candidate for rooftop PV: daytime HVAC load, lighting baseload, and a flat or low-slope roof that can usually accept 80 kWp without a structural redesign. This page models capex, yield, opex, and payback for an 80 kWp array at a US commercial gym. The model is vendor-neutral: no specific module or inverter OEM is implied. Inputs are cited; the TCO summary and 25-year cashflow below are the computed outputs and are computed. The page is sensitive to installed cost, specific yield, self-consumption share, and retail tariff.

## 1. Computed TCO summary (computed)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 7.00 % |
| Total undiscounted cost (USD) | 228,842.42 |
| Total discounted cost / PV of costs (USD) | 203,536.15 |
| Total undiscounted benefit (USD) | 390,087.69 |
| Total discounted benefit (USD) | 172,909.65 |
| NPV (USD) | -30,626.50 |
| IRR | 0.0520 |
| Simple payback (year) | 14.41 |
| Discounted payback (year) | — |
| LCOE (USD/kWh) | 0.1628 |

## 2. Year-by-year cash flow (computed)

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 184,000.00 | 0.0000 | -184,000.00 | 1.00 | -184,000.00 | 0.0000 |
| 1 | 1,400.00 | 12,992.00 | 11,592.00 | 0.9346 | 10,833.64 | 112,000.00 |
| 2 | 1,428.00 | 13,185.58 | 11,757.58 | 0.8734 | 10,269.53 | 111,440.00 |
| 3 | 1,456.56 | 13,382.05 | 11,925.49 | 0.8163 | 9,734.75 | 110,882.80 |
| 4 | 1,485.69 | 13,581.44 | 12,095.75 | 0.7629 | 9,227.79 | 110,328.39 |
| 5 | 1,515.41 | 13,783.80 | 12,268.40 | 0.7130 | 8,747.20 | 109,776.74 |
| 6 | 1,545.71 | 13,989.18 | 12,443.47 | 0.6663 | 8,291.61 | 109,227.86 |
| 7 | 1,576.63 | 14,197.62 | 12,620.99 | 0.6227 | 7,859.72 | 108,681.72 |
| 8 | 1,608.16 | 14,409.16 | 12,801.00 | 0.5820 | 7,450.30 | 108,138.31 |
| 9 | 1,640.32 | 14,623.86 | 12,983.54 | 0.5439 | 7,062.18 | 107,597.62 |
| 10 | 1,673.13 | 14,841.76 | 13,168.63 | 0.5083 | 6,694.26 | 107,059.63 |
| 11 | 1,706.59 | 15,062.90 | 13,356.31 | 0.4751 | 6,345.48 | 106,524.33 |
| 12 | 1,740.72 | 15,287.34 | 13,546.61 | 0.4440 | 6,014.86 | 105,991.71 |
| 13 | 1,775.54 | 15,515.12 | 13,739.58 | 0.4150 | 5,701.44 | 105,461.75 |
| 14 | 1,811.05 | 15,746.29 | 13,935.24 | 0.3878 | 5,404.33 | 104,934.45 |
| 15 | 1,847.27 | 15,980.91 | 14,133.64 | 0.3624 | 5,122.68 | 104,409.77 |
| 16 | 1,884.22 | 16,219.03 | 14,334.81 | 0.3387 | 4,855.70 | 103,887.72 |
| 17 | 1,921.90 | 16,460.69 | 14,538.79 | 0.3166 | 4,602.61 | 103,368.29 |
| 18 | 1,960.34 | 16,705.95 | 14,745.62 | 0.2959 | 4,362.70 | 102,851.44 |
| 19 | 1,999.54 | 16,954.87 | 14,955.33 | 0.2765 | 4,135.27 | 102,337.19 |
| 20 | 2,039.54 | 17,207.50 | 15,167.97 | 0.2584 | 3,919.69 | 101,825.50 |
| 21 | 2,080.33 | 17,463.89 | 15,383.57 | 0.2415 | 3,715.33 | 101,316.37 |
| 22 | 2,121.93 | 17,724.11 | 15,602.17 | 0.2257 | 3,521.62 | 100,809.79 |
| 23 | 2,164.37 | 17,988.19 | 15,823.82 | 0.2109 | 3,337.99 | 100,305.74 |
| 24 | 2,207.66 | 18,256.22 | 16,048.56 | 0.1971 | 3,163.92 | 99,804.21 |
| 25 | 2,251.81 | 18,528.24 | 16,276.42 | 0.1842 | 2,998.92 | 99,305.19 |

## 3. Inputs (cited; vendor-neutral)

| Parameter | Symbol | Value | Unit | Source |
| --- | --- | --- | --- | --- |
| DC nameplate | Pdc | 80 | kWp | Use case definition, TradVolt gym-solar-80kwp-us r9 |
| Performance ratio | PR | 0.82 | dimensionless | NREL, Best Practices for PV System Performance (PVPMC public guidance): NREL/TP-5K00-85022 |
| Specific yield, base | Y | 1,400 | kWh/kWp/yr | NREL PVWatts, US commercial rooftop reference (PVWatts typical-station output, AC): PVWatts calculator |
| Specific yield, low | Y_lo | 1,200 | kWh/kWp/yr | NREL PVWatts, northern US / lower-irradiance station reference: PVWatts calculator |
| Specific yield, high | Y_hi | 1,500 | kWh/kWp/yr | NREL PVWatts, southwestern US station reference: PVWatts calculator |
| Installed cost, low | C_lo | 1.90 | USD/Wp | NREL, U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks (Ramasamy et al., 2023, commercial-rooftop segment), cited summary report: NREL/TP-5K00-87303 |
| Installed cost, base | C_b | 2.30 | USD/Wp | NREL, U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks (Ramasamy et al., 2023, commercial-rooftop median): NREL/TP-5K00-87303 |
| Installed cost, high | C_hi | 2.50 | USD/Wp | NREL, U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks (Ramasamy et al., 2023, commercial-rooftop upper quartile): NREL/TP-5K00-87303 |
| Self-consumption share, base | S | 0.70 | fraction | TradVolt gym load profile estimate (typical daytime HVAC + lighting) |
| Self-consumption share, low | S_lo | 0.55 | fraction | TradVolt low-occupancy gym profile |
| Self-consumption share, high | S_hi | 0.85 | fraction | TradVolt high-occupancy gym profile |
| Retail tariff, base | T | 0.14 | USD/kWh | U.S. EIA, Commercial sector average electricity price (most recent monthly): EIA Electric Power Monthly, Table 5.1.A |
| Retail tariff, low | T_lo | 0.10 | USD/kWh | EIA, low-rate state reference: EIA Electric Power Monthly, Table 5.1.A |
| Retail tariff, high | T_hi | 0.22 | USD/kWh | EIA, high-rate state reference: EIA Electric Power Monthly, Table 5.1.A |
| Export price | E | 0.06 | USD/kWh | TradVolt bounded assumption for US commercial export compensation; verify with the local utility tariff schedule |
| Tariff escalation | — | 0.02 | fraction/yr | TradVolt bounded assumption (model assumption, not a sourced fact). The computed table uses a uniform 2% annual tariff escalation from index 0. |
| O&M, fixed | Om | 1,400 | USD/yr (Year 1) | TradVolt bounded assumption for 80 kWp commercial rooftop O&M (USD 17.5/kWp/yr in Year 1) |
| O&M escalation | — | 0.02 | fraction/yr | TradVolt bounded assumption (model assumption, not a sourced fact). computed table escalates O&M at 2% per year. |
| Annual degradation | D | 0.005 | fraction/yr | NREL, Best Practices for PV System Performance, degradation-rate reference: NREL/TP-5K00-85022 |
| Analysis horizon | N | 25 | years | Standard PV economic life, matched to computed table |
| Discount rate | r | 0.07 | fraction/yr | TradVolt commercial WACC assumption, matched to computed table |
| Residual value | — | 0.00 | USD at Year 25 | TradVolt bounded assumption (model assumption, not a sourced fact). computed table sets terminal asset value to zero. |

The page is vendor-neutral: no specific module family or inverter OEM is implied. Generic module/inverter performance is used to populate the computed table. Real product references are presented in Section 6 only as illustrative examples of publicly-marketed equipment that an actual gym might substitute; their datasheet performance is not assumed here.

## 4. Formulae (transparent)

Annual energy in year t (kWh):

**E(t) = Pdc &times; Y &times; (1 - D)^(t-1)**

Annual savings in year t (USD), with tariff and O&M escalation at rate g = 0.02:

**Sav(t) = E(t) &times; S &times; T &times; (1 + g)^(t-1) + E(t) &times; (1 - S) &times; Ee &times; (1 + g)^(t-1) - Om &times; (1 + g)^(t-1)**

where Ee is the export price (USD/kWh) and Om is the Year-1 O&M cost.

Capex (USD):

**Capex = Pdc &times; 1000 &times; C**

Simple payback (years): year in which cumulative undiscounted savings first equals Capex. Discounted payback (years): year in which cumulative discounted savings first equals Capex, using discount factor (1 + r)^t. Both are reported in the TCO summary and decision table.

Net Present Value over N years:

**NPV = -Capex + Sum_{t=1..N} Sav(t) / (1 + r)^t**

Note: capex is shown pre-incentive. The US federal Investment Tax Credit (ITC) under the Inflation Reduction Act of 2022 provides a base 30% credit for qualifying commercial PV; bonus adders (domestic content, energy communities, low-income) may apply. The base-case computed table excludes ITC so the underlying economics are visible. Apply ITC by multiplying Capex by (1 - 0.30) for the base credit; the resulting ITC-adjusted simple payback lies between the base-case values and must be verified with a tax professional. ITC must be applied on either the discounted or the undiscounted series, not both, to avoid double-counting.

## 5. Sensitivity table (year-1 net savings)

Each cell shows Sav(1) in USD, recomputed from the stated formula at g = 0:

**Sav(1) = Pdc &times; Y &times; S &times; T + Pdc &times; Y &times; (1 - S) &times; Ee - Om**

| Yield Y (kWh/kWp) | Self-use S | Tariff T (USD/kWh) | Sav(1) (USD) |
| --- | --- | --- | --- |
| 1,200 | 0.55 | 0.10 | 6,472 |
| 1,200 | 0.55 | 0.22 | 12,296 |
| 1,200 | 0.85 | 0.10 | 8,152 |
| 1,200 | 0.85 | 0.22 | 17,048 |
| 1,500 | 0.55 | 0.10 | 8,492 |
| 1,500 | 0.55 | 0.22 | 16,172 |
| 1,500 | 0.85 | 0.10 | 10,592 |
| 1,500 | 0.85 | 0.22 | 22,112 |
| 1,400 | 0.70 | 0.14 | 11,592 |

Worked example for the lowest cell: 80 &times; 1,200 &times; 0.55 &times; 0.10 = 5,280; 80 &times; 1,200 &times; 0.45 &times; 0.06 = 2,592; total 7,872 - 1,400 = **6,472 USD**.

Capex by cost band (USD):

| Cost band | C (USD/Wp) | Capex (USD) |
| --- | --- | --- |
| Low | 1.90 | 152,000 |
| Base | 2.30 | 184,000 |
| High | 2.50 | 200,000 |

## 6. Illustrative equipment references (not assumed in the computed table)

The computed table above is vendor-neutral. The following are real, publicly marketed products that an actual gym-rooftop project might substitute. Their public datasheets or product pages are linked. No claim is made that these products were used in, or are endorsed for, the base case.

- [LONGi](https://www.longi.com/en/) Hi-MO 5 / Hi-MO 6 mono-PERC and back-contact module families; product datasheets published on the LONGi site.

- [JinkoSolar](https://www.jinkosolar.com/en/) Tiger Neo / Tiger Pro module families; product datasheets published on the Jinko site.

- [Trina Solar](https://www.trinasolar.com/us-en) Vertex / Vertex S+ module families; product datasheets published on the Trina site.

- [Sungrow](https://www.sungrowpower.com/en) SG string inverter families (commercial-scale three-phase); product datasheets published on the Sungrow site.

- [Huawei FusionSolar](https://solar.huawei.com/en) SUN2000 string inverter families; product datasheets published on the Huawei site.

- [Growatt](https://www.growatt.com/) commercial string inverter families; product datasheets published on the Growatt site.

Choose equipment only after confirming the model family, datasheet revision, and torque/SOC/voltage limits against the OEM manual at the RFQ stage.

## 7. Mini certification block (informational only; no specific shipment is certified)

- Modules: UL 61730-1 Photovoltaic (PV) Module Safety Qualification - Part 1, and IEC 61215 / IEC 61730 series (issued by UL LLC; verify the certificate number per shipment against the [UL 61730-1 standard page](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1) and the IEC Webstore [IEC catalogue](https://webstore.iec.ch/)).

- Inverters: UL 1741 (issued by UL LLC) and IEEE 1547 series (issued by IEEE); verify certificate number per shipment.

- Installation: NFPA 70 (National Electrical Code, NEC 690) and NFPA 70E; racking UL 2703 (issued by UL LLC). Verify local AHJ adoption.

- Installer: NABCEP PV Installation Professional certification recommended; verify individual certification number on the NABCEP registry.

- Grid interconnection: state PUC rules and the local utility interconnection agreement; verify with the serving utility.

This block is informational. It does not certify any specific shipment, and the absence of a certificate number above is intentional. Always confirm the certificate revision, edition, and issuing body against the standard page linked.

## 8. HS code lookup (PENDING rates; use the linked lookup tool)

| Component | HS code (US HTSUS, indicative) | Description | Duty rate |
| --- | --- | --- | --- |
| Crystalline silicon PV modules | 8541.43.00 | Photovoltaic cells and panels | PENDING - verify via the USITC HTS lookup |
| String inverters | 8504.40.95 | Static converters, other | PENDING - verify via the USITC HTS lookup |
| Mounting structures, aluminum | 7610.90.00 | Aluminum structures and parts | PENDING - verify via the USITC HTS lookup |
| DC cables, PV-rated | 8544.60.60 | Other electric conductors, >1,000 V | PENDING - verify via the USITC HTS lookup |
| Combiner / disconnect | 8536.90.40 | Other apparatus for switching/protecting | PENDING - verify via the USITC HTS lookup |

Lookup instructions:

1. Open the USITC Harmonized Tariff Schedule search: [hts.usitc.gov](https://hts.usitc.gov/).

2. Enter the HTSUS number above and read the current General Duty rate in chapter 99 notes.

3. Confirm Section 201 safeguard tariffs and Section 301 China-origin tariffs where applicable (refer also to [US Customs and Border Protection](https://www.cbp.gov/)).

4. Confirm FTA preference eligibility (USMCA and FTA partners) via [US International Trade Administration](https://www.trade.gov/) if relevant.

5. Verify via a binding Customs ruling or a licensed customs broker before import.

Disclaimer: the duty rates above are marked PENDING and must not be treated as fact. TradVolt does not provide legal or customs advice. Always confirm rates against the [USITC HTS lookup](https://hts.usitc.gov/) and a licensed customs broker.

## 9. RFQ

Single RFQ anchor - request a bound quote for an 80 kWp gym rooftop system, US site, with your interconnection utility and roof survey:

[Request a formal RFQ for the 80 kWp US gym solar package &raquo;](https://tradvolt.com/rfq/)

## 10. Sources cited

- NREL, Best Practices for PV System Performance (PVPMC), NREL/TP-5K00-85022: [https://www.nrel.gov/docs/fy23osti/85022.pdf](https://www.nrel.gov/docs/fy23osti/85022.pdf)

- NREL PVWatts calculator: [https://pvwatts.nrel.gov/](https://pvwatts.nrel.gov/)

- NREL, U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks (Ramasamy et al., 2023), NREL/TP-5K00-87303: [https://www.nrel.gov/docs/fy23osti/87303.pdf](https://www.nrel.gov/docs/fy23osti/87303.pdf)

- U.S. EIA, Electric Power Monthly, Table 5.1.A (Commercial sector average price): [https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_es1a](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_es1a)

- Inflation Reduction Act of 2022, Section 48 ITC (base 30% credit; verify bonus adders with a tax advisor).

- USITC Harmonized Tariff Schedule search: [https://hts.usitc.gov/](https://hts.usitc.gov/)

- US Customs and Border Protection: [https://www.cbp.gov/](https://www.cbp.gov/)

- US International Trade Administration: [https://www.trade.gov/](https://www.trade.gov/)

- UL 61730-1 Photovoltaic (PV) Module Safety Qualification - Part 1 (UL LLC): [https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1)

- IEC Webstore (catalogue for IEC 61215, IEC 61730, IEC 61851-1 and related standards): [https://webstore.iec.ch/](https://webstore.iec.ch/)

TradVolt RFQ form: [https://tradvolt.com/rfq/](https://tradvolt.com/rfq/)
