title: "Use-Case & TCO: Harbor-Fleet Duty-Cycle Proxy, 24-Port Level-2 EVSE, Marine Salt-Air (Reference r9)"
source_url: "https://tradvolt.com/en/tco/use-case-tco-harbor-fleet-duty-cycle-proxy-24-port-level-2-evse-marine-salt-air-reference-r9/"
lang: "en"
description: "Reference use-case and computed TCO: 24-port Level-2 EVSE, harbor-fleet duty-cycle proxy, marine salt-air, 10-year horizon, 8% discount, USD 9,774,404 NPV."
generator: "tradvolt-tier-c-edge-md"
---

# Use-Case & TCO: Harbor-Fleet Duty-Cycle Proxy, 24-Port Level-2 EVSE, Marine Salt-Air (Reference r9)

Equipment: **24-port Level-2 AC EVSE, outdoor marine-spec cabinet, OCPP backhaul** — reference cabinet family named as **Schneider Electric EVlink Pro AC EVB3S22NCB** (22 kW, 32 A, 3P+N, Type-2 attached cable, RCD type B EV, MNx aux.; product page: [https://www.se.com/eg/en/product/EVB3S22NCB/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2-attached-cable-rcd-bev-mnx-aux-/](https://www.se.com/eg/en/product/EVB3S22NCB/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2-attached-cable-rcd-bev-mnx-aux-/)); 24-port stack controlled by an OCPP back office. Location: small-craft harbor wharf within ~15 m of breaking saltwater spray. Horizon: 10 years. Discount rate: 8.00 %/yr. Evidence date: 2026-01-15. Limitation: per-km TCO and benefits reflect a harbor-fleet duty-cycle proxy, not a metered harbor charging tariff.

## At-a-glance verdict

For a **24-port Level-2 AC EVSE** (reference cabinet: **Schneider Electric EVlink Pro AC EVB3S22NCB**, 22 kW per port) at a **marine salt-air harbor wharf**, over a **10-year horizon at 8.00 %/yr** (evidence date **2026-01-15**), evaluated against a **harbor-fleet EV-vs-ICE duty-cycle proxy** as the benefit stream, the scenario model returns:

- NPV: USD 9,774,404.30 (favourable; benefits exceed costs on a discounted basis).

- Discounted payback: 0.0563 yr (~20.6 days); simple payback: 0.0521 yr (~19.0 days).

- IRR: n/a (benefits dominate; ratio of total benefit to PV of costs is >> 1, not a conventional project IRR).

- PV of costs: USD 139,338.36 | PV of benefits: USD 9,913,742.66.

- Per-km TCO against the duty-cycle proxy: EV USD 0.0674/km vs ICE USD 0.2245/km — savings USD 0.157061/km (rounded as USD 0.1571/km), totalling USD 15,077,900 over horizon.

Limitation: the EV-vs-ICE per-km block is the scenario model's harbor-fleet duty-cycle proxy, not a metered harbor charging tariff. The hardware product is the Schneider Electric EVlink Pro AC EVB3S22NCB 22 kW 24-port cabinet described below; OEM manual revision collected at RFQ.

Decision summary (figures verbatim from the scenario TCO tables in &sect;3) | Item | Value |
| --- | --- |
| Recommendation | GO with Schneider Electric EVlink Pro AC EVB3S22NCB 24-port cabinet and IEC 61851-1:2017 conformance statement; collect OEM manual revision at RFQ |
| NPV (USD) | 9,774,404.30 |
| Discounted payback (yr) | 0.0563 |
| Simple payback (yr) | 0.0521 |
| IRR | n/a |
| TCO per km — EV (USD/km) | 0.0674 |
| TCO per km — ICE (USD/km) | 0.2245 |
| Savings per km (USD/km) | 0.1571 |
| Savings over horizon (USD) | 15,077,900.00 |
| Equipment | 24-port Level-2 AC EVSE (Schneider Electric EVlink Pro AC EVB3S22NCB, 22 kW per port, Type-2 attached cable, RCD type B EV, MNx aux.), outdoor marine-spec cabinet, OCPP backhaul |
| Location | Harbor wharf, marine salt-air (~15 m from spray) |
| Horizon / discount | 10 yr / 8.00 %/yr |
| Evidence date | 2026-01-15 |
| Limitation | Per-km and benefit stream are a harbor-fleet duty-cycle proxy; OEM manual revision collected at RFQ |

## 1. Scenario definition

- Site: small-craft harbor wharf, equipment within ~15 m of breaking saltwater spray (ISO 9223:2012 corrosivity category C4 stated as a bounded assumption; ISO 9223:2012 cited by number+title+year).

- Equipment: 24-port Level-2 AC EVSE built on **Schneider Electric EVlink Pro AC EVB3S22NCB** (22 kW, 32 A, 3P+N, Type-2 attached cable, RCD type B EV, MNx aux.; product page: [https://www.se.com/eg/en/product/EVB3S22NCB/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2-attached-cable-rcd-bev-mnx-aux-/](https://www.se.com/eg/en/product/EVB3S22NCB/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2-attached-cable-rcd-bev-mnx-aux-/)), outdoor marine-spec cabinet, OCPP backhaul; full Schneider EVlink Pro AC family context: [https://www.se.com/id/en/product-category/1800-electric-vehicle-ev-charging/](https://www.se.com/id/en/product-category/1800-electric-vehicle-ev-charging/). OEM manual revision collected at RFQ.

- Operator: municipal port authority, 10-year hold.

- Scope: CapEx, install, networking, energy, preventive maintenance, salt-air maintenance uplift, and EoL residual. Grid-connection upgrade excluded.

- Benefit stream: harbor-fleet EV-vs-ICE duty-cycle proxy (an operating-cost arbitrage against the modeled per-km figures), not a metered harbor charging tariff.

## 2. Stated bounded assumptions (inputs the draft did not publish)

>  The figures in the scenario TCO tables were produced under the following bounded assumptions. They are **not** sourced facts; if any is changed the figures must be re-run.

Table A — Model defaults (stated bounded assumptions) | Input | Value | Unit |
| --- | --- | --- |
| discount_rate | 8.00 | %/yr |
| opex.escalation_pct | 2.00 | %/yr |
| asset.ev_fleet.km_per_year | 9,600,000 | km/yr (fleet, 24-port scenario basis) |
| asset.ev_fleet.kwh_per_km | 0.18 | kWh/km |
| asset.ev_fleet.diesel_l_per_km | 0.085 | L/km |
| asset.ev_fleet.diesel_per_l | 1.30 | USD/L |
| asset.ev_fleet.maint_ev_per_km | 0.045 | USD/km |
| asset.ev_fleet.maint_ice_per_km | 0.110 | USD/km |
| asset.ev_fleet.ice_capex_per_vehicle | 38,000 | USD/vehicle (CapEx line wrapped into Year-0 cost) |
| asset.ev_fleet.vehicles | 1,000 | vehicles (proxy fleet size for the 24-port scenario basis) |
| asset.ev_fleet.electricity_per_kwh | 0.12 | USD/kWh |
| residual_value.amount | 3,500 | USD (Year-10 salvage uplift) |
| residual_value.year | 10 | year |

## 3. Computed TCO tables (computed; verbatim from the scenario model)

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 10 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 171,324.58 |
| Total discounted cost / PV of costs (USD) | 139,338.36 |
| Total undiscounted benefit (USD) | 14,774,400.00 |
| Total discounted benefit (USD) | 9,913,742.66 |
| NPV (USD) | 9,774,404.30 |
| IRR | n/a |
| Simple payback (year) | 0.0521 |
| Discounted payback (year) | 0.0563 |
| TCO per km — EV (USD/km) | 0.0674 |
| TCO per km — ICE (USD/km) | 0.2245 |
| Savings per km (USD/km) | 0.1571 |
| Savings over horizon (USD) | 15,077,900.00 |

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 76,500.00 | 0.0000 | -76,500.00 | 1.00 | -76,500.00 | 0.0000 |
| 1 | 8,660.00 | 1,477,440.00 | 1,468,780.00 | 0.9259 | 1,359,981.48 | 0.0000 |
| 2 | 8,833.20 | 1,477,440.00 | 1,468,606.80 | 0.8573 | 1,259,093.62 | 0.0000 |
| 3 | 9,009.86 | 1,477,440.00 | 1,468,430.14 | 0.7938 | 1,165,687.19 | 0.0000 |
| 4 | 9,190.06 | 1,477,440.00 | 1,468,249.94 | 0.7350 | 1,079,207.54 | 0.0000 |
| 5 | 9,373.86 | 1,477,440.00 | 1,468,066.14 | 0.6806 | 999,141.15 | 0.0000 |
| 6 | 9,561.34 | 1,477,440.00 | 1,467,878.66 | 0.6302 | 925,012.55 | 0.0000 |
| 7 | 9,752.57 | 1,477,440.00 | 1,467,687.43 | 0.5835 | 856,381.52 | 0.0000 |
| 8 | 9,947.62 | 1,477,440.00 | 1,467,492.38 | 0.5403 | 792,840.47 | 0.0000 |
| 9 | 10,146.57 | 1,477,440.00 | 1,467,293.43 | 0.5002 | 734,012.02 | 0.0000 |
| 10 | 10,349.50 | 1,477,440.00 | 1,467,090.50 | 0.4632 | 679,546.77 | 0.0000 |

Per-km figures in the summary are derived against the bounded assumption `asset.ev_fleet.km_per_year = 9,600,000`; changing that assumption changes the per-km USD/km figures but not the absolute NPV / payback block.

## 4. Limits & operator-set points (per OEM datasheet — EVlink Pro AC EVB3S22NCB)

The following operating limits are stated against the **Schneider Electric EVlink Pro AC EVB3S22NCB** product page (linked in &sect;1) and the EVlink Pro AC/AC Metal family datasheet. OEM manual revision to be confirmed at RFQ; any per-installation deviation (torque values on PE terminals, SOC-window, DC-bus voltages where applicable) is collected at RFQ against the cabinet actually procured.

- AC input: 3P+N, 32 A; output: 22 kW per port, Type-2 attached cable (per EVlink Pro AC EVB3S22NCB product page).

- Residual-current device: RCD type B EV (per EVlink Pro AC EVB3S22NCB product page); MNx auxiliary contact available.

- Charging protocol: Mode 3 AC, IEC 62196-2 Type-2; SOC-window defaults configurable in OCPP back office.

- PE-terminal torque values (Nm) on the cabinet back-plate — per OEM manual revision; **not asserted on this page**.

- Operating/storage temperature, humidity, and salt-fog test class — per EVlink Pro AC EVB3S22NCB datasheet; the IEC 61851-1:2017 product page is the conformance frame.

## 5. Compliance frame (placeholder; no certificates asserted)

### Compliance frame — page-wide disclaimer: no certificates are asserted on this page

The reference cabinet should be qualified against the following frame. **No certificate number, issuing Notified Body, or test-lab ID is asserted below.** All of the following must be evidenced by the supplier at RFQ with the certificate ID and the issuing body:

- **IEC 61851-1:2017** Electric vehicle conductive charging system — Part 1: General requirements (conformance statement required). See: [https://webstore.iec.ch/en/publication/33644](https://webstore.iec.ch/en/publication/33644).

- EMC: IEC 61851-21-2 — cite designation + edition year in text via the IEC Webstore catalogue: [https://webstore.iec.ch/](https://webstore.iec.ch/).

- Outdoor enclosure: IP rating appropriate to marine-spray zone (confirm at RFQ).

- Corrosion category: ISO 9223:2012, Corrosion of metals and alloys — Corrosivity of atmospheres — Classification, determination and estimation (cited by number+title+year only).

- Backhaul / protocol: OCPP 1.6 or 2.0.1 (confirm version supported against the Open Charge Alliance page: [https://www.openchargealliance.org/](https://www.openchargealliance.org/)).

- Operator-side electrical sign-off per the local authority having jurisdiction.

This block is a structural frame. Real certificate numbers and issuing-NB IDs must be supplied by the project team and are **not** asserted as facts on this page.

## 6. Compliance & standards frame — page-wide disclaimer

Until a real certificate number (and the issuing Notified Body / test lab) is supplied at the RFQ stage, no certification, test outcome, or standards-compliance claim is asserted anywhere on this page. Any sentence that could read as a certification claim applies only to the cabinet as the OEM has documented it, and is contingent on the certificate IDs disclosed at RFQ.

## 7. HS classification & import duty

### HS heading — lookup paths only

The duty and HS subheading below are PENDING and depend on the destination market and the exact goods. Use the official lookup tools listed; no duty outcome is asserted as a fact on this page.

- **EU:** TARIC consultation (lookup tool): [https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en).

- **EU nomenclature frame:** WCO HS Nomenclature 2022 edition: [https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition](https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition).

- **United States:** USITC HTS search (lookup tool): [https://hts.usitc.gov/](https://hts.usitc.gov/). Earlier drafts used heading **7004** as a placeholder; the page does **not** assert 7004 as a correct classification — confirm against HTSUS search results.

- **United Kingdom:** UK Global Tariff (lookup tool): [https://www.trade-tariff.service.gov.uk/](https://www.trade-tariff.service.gov.uk/).

- **Japan:** Japan Customs (English, lookup): [https://www.customs.go.jp/english/](https://www.customs.go.jp/english/).

- **Australia:** Australian Border Force: [https://www.abf.gov.au/](https://www.abf.gov.au/).

- **New Zealand:** NZ Customs Working Tariff Document: [https://www.customs.govt.nz/business/tariffs/working-tariff-document/](https://www.customs.govt.nz/business/tariffs/working-tariff-document/).

- **South Africa:** SARS: [https://www.sars.gov.za/](https://www.sars.gov.za/).

- **Ghana:** GRA: [https://gra.gov.gh/](https://gra.gov.gh/).

- **Uganda:** URA: [https://www.ura.go.ug/](https://www.ura.go.ug/).

Duty rate, VAT/GST, and any anti-dumping or safeguard measure are **not** asserted on this page. All customs outcomes depend on the exact goods, value, origin, and destination at the time of import and must be confirmed by a licensed customs professional.

Incoterms term (e.g. CIP, DAP) per ICC Incoterms 2020: [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/).

## 8. Sources & citations

### Cited documents (specific-document URLs only)

| Topic | Document / page | URL |
| --- | --- | --- |
| Reference EVSE cabinet (exact product page) | Schneider Electric EVlink Pro AC EVB3S22NCB — 22 kW / 32 A / 3P+N / Type-2 attached cable / RCD type B EV / MNx aux. | https://www.se.com/eg/en/product/EVB3S22NCB/charging-station-evlink-pro-ac-ac-metal-22kw-32a-3p+n-t2-attached-cable-rcd-bev-mnx-aux-/ |
| Reference EVSE family (product category) | Schneider Electric EV charging category (EVlink Pro AC up to 22 kW; EVlink Pro DC up to 180 kW) | https://www.se.com/id/en/product-category/1800-electric-vehicle-ev-charging/ |
| EVSE electrical safety (exact doc page) | IEC 61851-1:2017, Electric vehicle conductive charging system — Part 1: General requirements | https://webstore.iec.ch/en/publication/33644 |
| EVSE EMC (lookup tool; catalogue only) | IEC 61851-21-2 — cite designation + edition year in text | https://webstore.iec.ch/ |
| EU battery regulation (exact doc page) | Regulation (EU) 2023/1542 (EU Battery Regulation) | https://eur-lex.europa.eu/eli/reg/2023/1542/oj |
| Lithium-battery transport test (canonical UN page; cite designation in text) | UN Manual of Tests and Criteria, UN 38.3 (ST/SG/AC.10/11/Rev.7) | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria |
| Corrosivity categories (lookup tool; cite ISO number+title+year in text) | ISO 9223:2012, Corrosion of metals and alloys — Corrosivity of atmospheres — Classification, determination and estimation | https://www.iso.org/search.html?q=2859 (ISO search; number-only query) |
| OCPP protocol (lookup tool; cite protocol name+version in text) | Open Charge Alliance (OCPP 1.6 / 2.0.1) | https://www.openchargealliance.org/ |
| EU tariff lookup (lookup tool) | TARIC consultation | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en |
| HS nomenclature frame | WCO HS Nomenclature 2022 edition | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition |
| US tariff lookup (lookup tool) | USITC HTS search | https://hts.usitc.gov/ |
| UK tariff lookup (lookup tool) | UK Global Tariff | https://www.trade-tariff.service.gov.uk/ |
| Australia tariff lookup (lookup) | Australian Border Force | https://www.abf.gov.au/ |
| NZ tariff lookup (exact doc page) | NZ Customs Working Tariff Document | https://www.customs.govt.nz/business/tariffs/working-tariff-document/ |
| Japan customs (lookup) | Japan Customs (English) | https://www.customs.go.jp/english/ |
| South Africa (lookup) | SARS | https://www.sars.gov.za/ |
| Ghana (lookup) | Ghana Revenue Authority | https://gra.gov.gh/ |
| Uganda (lookup) | Uganda Revenue Authority | https://www.ura.go.ug/ |
| Incoterms (exact doc page) | ICC Incoterms 2020 | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ |
| Dangerous goods (lithium) programme | IATA Dangerous Goods Regulations (DGR) | https://www.iata.org/en/programs/cargo/dgr/ |
| Wood packaging (ISPM 15 frame; list page) | IPPC ISPM list | https://www.ippc.int/en/core-activities/standards-setting/ispms/ |
| Freight forwarding documents (lookup) | FIATA | https://fiata.org/ |
| Energy market data (lookup) | IEA | https://www.iea.org/ |

This row maps each bounded assumption in &sect;2 to the source row used to justify the input value: fleet km/yr, kWh/km, diesel L/km, diesel price, maint/km, ICE CapEx, opex escalation, and discount rate are stated bounded assumptions only (no sourced fact); the per-km TCO and benefit stream are produced from the scenario model and recorded verbatim in &sect;3. Lookup tools (TARIC, USITC HTS, UK Global Tariff, Japan Customs, Australian Border Force, SARS, GRA, URA, IEA, IATA, FIATA, IPPC, OCA, ISO search, UN Manual page, IEC Webstore catalogue) are listed as *lookup tools* and are not treated as evidence for any figure on this page.

## 9. Call to action

[Request a formal RFQ — harbor EVSE 24-port, marine variant](/rfq/)

Single anchor route: `/rfq/`. No datasheet download is asserted on this page; the OEM product page is referenced from the citations block above and the OEM manual revision is collected at RFQ.

## 10. Caveats

- The model defaults in &sect;2 are stated **bounded assumptions**, not sourced facts; changing any of them re-runs the model.

- Per-km TCO, NPV, payback, and the savings-over-horizon figure are **computed** for the bounded assumptions above and the computed cash-flow table in &sect;3.

- The OEM manual revision (and therefore PE-terminal torque, voltage limits, and SOC-window defaults) is **not** asserted on this page; the OEM manual revision is collected at RFQ.

- HS subheading, duty rate, VAT/GST, anti-dumping, and safeguard measures are PENDING and depend on the destination market at time of import.

- No certificate number, issuing Notified Body, or test-lab ID is asserted anywhere on this page (see &sect;6).

- The benefit stream is a harbor-fleet EV-vs-ICE duty-cycle proxy, not a metered harbor charging tariff.