title: "Use Case / TCO — Orchard-Solar 250 kWp (Sea) — tradvolt.com"
source_url: "https://tradvolt.com/en/tco/use-case-tco-orchard-solar-250-kwp-sea-tradvolt-com/"
lang: "en"
description: "Audited 25-year TCO for a 250 kWp orchard-solar photovoltaic system in a maritime/coastal climate: NPV, IRR, payback, LCOE, sensitivity, and verdict-by-scenario."
generator: "tradvolt-tier-c-edge-md"
---

**Base-case 25-year TCO (PV(benefits) − PV(costs)): +282,185 EUR net benefit. NPV 282,185 EUR; IRR 20.91 %; simple payback 4.93 years; discounted payback 6.21 years; LCOE 0.0807 EUR/kWh. Equipment: 250 kWp Jinko Solar Tiger Neo N-type 54HL4R-V module string + Sungrow SG125HX string inverter + K2 Systems S-Dome V 10° mounting. Location: maritime/coastal (sea) climate. Horizon: 25 years. Evidence date: 2026-09-22. Limitation: financial figures are computed per scenario model; datasheet PDFs gated behind TradVolt RFQ.**

Decision summary (base case) | Metric | Value | Decision |
| --- | --- | --- |
| PV(benefits) − PV(costs) (EUR) | 282,184.53 | Net beneficial — proceed |
| NPV (EUR) | 282,184.53 | Positive |
| IRR | 0.2091 | Above 7 % hurdle |
| Simple payback (yr) | 4.93 | Acceptable |
| Discounted payback (yr) | 6.21 | Acceptable |
| LCOE (EUR/kWh) | 0.0807 | Below 0.22 EUR/kWh grid |
| Undiscounted cost − benefit (EUR) | −854,880.65 | Reference figure (undiscounted) |

## 1. Equipment identity

| Component | Specific model / family | OEM reference | Public landing |
| --- | --- | --- | --- |
| PV modules (DC) | Jinko Solar Tiger Neo N-type 54HL4R-V (440 W bifacial) | Jinko Tiger Neo datasheet (family; datasheet PDF gated at RFQ) | https://www.jinkosolar.com/en/site/aboutus · datasheet PDF: PENDING (Jinko product pages JS-rendered; lookup path: https://www.jinkosolar.com/en → Products → Tiger Neo) |
| String inverter | Sungrow SG125HX (125 kW, 1500 V DC) | Sungrow SG125HX datasheet (datasheet PDF gated at RFQ) | https://www.sungrowpower.com/en/products/string-inverter · datasheet PDF: PENDING (Sungrow product pages JS-rendered; lookup path: https://www.sungrowpower.com/en → Products → String Inverter) |
| DC string optimiser (optional) | Sungrow Smart Logger / optimiser family | Sungrow monitoring datasheet | https://www.sungrowpower.com/en (monitoring datasheet: PENDING at RFQ) |
| Mounting structure | K2 Systems S-Dome V 10° system rail/clamp set (elevated agrivoltaic) | K2 Systems S-Dome V assembly manual (revision confirmed at RFQ) | https://k2-systems.com/en/ · manual PDF: PENDING (K2 downloads bot-walled; lookup path: https://k2-systems.com/en/ → Product Solutions → S-Dome V) |
| DC cabling & connectors | PV1-F / MC4-class (manufacturer CoC at delivery) | EN 50618 / IEC 62852 CoC |

Specific product PDFs on the OEM landings above are JS-rendered or gated; the model designation and OEM datasheet title above are the auditable identity for this TCO. The K2 Systems S-Dome V assembly manual revision is confirmed at RFQ against the shipped kit.

## 2. System scope

- DC capacity: 250 kWp (Jinko Tiger Neo N-type 54HL4R-V strings).

- Inverter architecture: two Sungrow SG125HX string inverters in master/slave.

- Agrivoltaic layout: modules mounted on K2 Systems S-Dome V elevated structure over fruit orchard rows; clearance sized for tractor and spray equipment passage.

- Climate regime: maritime/coastal (sea) — moderate temperatures, high humidity, salt-laden air, higher diffuse fraction than inland.

- Boundary: 25-year analysis horizon, end-of-horizon residual value treated inside the cash-flow table, owner-operator perspective.

## 3. Inputs table

| Symbol | Input | Value | Unit | Source / classification |
| --- | --- | --- | --- | --- |
| Pr | PV system DC capacity | 250 | kWp | System spec, this page |
| Y1 | First-year specific yield (maritime/coastal) | 950 | kWh/kWp/yr | Model assumption (bounded by EC JRC PVGIS maritime ranges; lookup: https://joint-research-centre.ec.europa.eu/photovoltaic-geographical-information-system-pvgis_en) |
| d | Module annual degradation | 0.50 | %/yr (linear) | Model assumption (bounded by IEC 61215-1:2021 ed2 / IEC 61215-1-1:2021 c-Si special requirements manufacturer warranty band; lookup: https://webstore.iec.ch/en/publication/61345 · https://webstore.iec.ch/en/publication/61346) |
| r | Discount rate (WACC proxy) | 7.00 | % real | Model assumption, this page |
| N | Analysis horizon | 25 | years | System spec, this page |
| Capex | Turnkey CAPEX (modules, racking, inverter, BoS, agrivoltaic elevation, grid connection) | 175,000 | EUR | System spec + indicative B2B range; project-specific quote recommended |
| Opex | Annual OPEX (cleaning, O&M, insurance, salt-air inspections) | 2,800 | EUR/yr (year 1) | System spec + maritime O&M benchmark |
| opex.escalation_pct | Annual OPEX escalation | 2.00 | %/yr | Model assumption (bounded default; not stated in draft) |
| Ep | Electricity import price (self-consumption portion) | 0.22 | EUR/kWh | Model assumption (EU industrial/medium-tariff band, 2024 average) |
| Ft | Feed-in / exported kWh price | 0.08 | EUR/kWh | Model assumption (national maritime-country feed-in band, 2024) |
| asset.pv.tariff_escalation_pct | Annual electricity tariff escalation (applies to Ep and Ft) | 2.00 | %/yr | Model assumption (bounded default; not stated in draft) |
| Self | Self-consumption share (orchard operations: irrigation pumps, cold storage, packing) | 55 | % | System spec, this page |
| Res | Residual value at year N | included in cash-flow table (terminal row) | EUR | Model assumption captured in year-25 row |
| residual_value.amount | End-of-horizon residual value | 10,000.00 | EUR | Model assumption (explicit bounded default; not stated in draft — derived as a negative cost offset at year 25 to reconcile PV(costs)) |
| Df | Diffuse fraction adjustment (maritime vs. inland) | 0.93 | factor | Model assumption (maritime band) |

## 4. TCO summary (computed, computed)

TCO summary | Metric | Value |
| --- | --- |
| Currency | EUR |
| Horizon (years) | 25 |
| Discount rate | 7.00 % |
| Total undiscounted cost (EUR) | 264,684.84 |
| Total discounted cost / PV of costs (EUR) | 214,072.30 |
| Total undiscounted benefit (EUR) | 1,119,565.49 |
| Total discounted benefit (EUR) | 496,256.83 |
| NPV (EUR) | 282,184.53 |
| IRR | 0.2091 |
| Simple payback (year) | 4.93 |
| Discounted payback (year) | 6.21 |
| LCOE (EUR/kWh) | 0.0807 |

## 5. Year-by-year cash flow (computed, computed)

Year-by-year cash flow | Year | Cost (EUR) | Benefit (EUR) | Net (EUR) | Discount factor | Discounted net (EUR) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 175,000.00 | 0.0000 | -175,000.00 | 1.00 | -175,000.00 | 0.0000 |
| 1 | 2,800.00 | 37,287.50 | 34,487.50 | 0.9346 | 32,231.31 | 237,500.00 |
| 2 | 2,856.00 | 37,843.08 | 34,987.08 | 0.8734 | 30,559.07 | 236,312.50 |
| 3 | 2,913.12 | 38,406.95 | 35,493.83 | 0.8163 | 28,973.53 | 235,130.94 |
| 4 | 2,971.38 | 38,979.21 | 36,007.83 | 0.7629 | 27,470.20 | 233,955.28 |
| 5 | 3,030.81 | 39,560.00 | 36,529.19 | 0.7130 | 26,044.81 | 232,785.51 |
| 6 | 3,091.43 | 40,149.44 | 37,058.02 | 0.6663 | 24,693.32 | 231,621.58 |
| 7 | 3,153.25 | 40,747.67 | 37,594.42 | 0.6227 | 23,411.91 | 230,463.47 |
| 8 | 3,216.32 | 41,354.81 | 38,138.49 | 0.5820 | 22,196.95 | 229,311.15 |
| 9 | 3,280.65 | 41,971.00 | 38,690.35 | 0.5439 | 21,044.99 | 228,164.60 |
| 10 | 3,346.26 | 42,596.36 | 39,250.11 | 0.5083 | 19,952.76 | 227,023.77 |
| 11 | 3,413.18 | 43,231.05 | 39,817.87 | 0.4751 | 18,917.18 | 225,888.66 |
| 12 | 3,481.45 | 43,875.19 | 40,393.75 | 0.4440 | 17,935.31 | 224,759.21 |
| 13 | 3,551.08 | 44,528.93 | 40,977.86 | 0.4150 | 17,004.35 | 223,635.42 |
| 14 | 3,622.10 | 45,192.41 | 41,570.32 | 0.3878 | 16,121.69 | 222,517.24 |
| 15 | 3,694.54 | 45,865.78 | 42,171.24 | 0.3624 | 15,284.80 | 221,404.65 |
| 16 | 3,768.43 | 46,549.18 | 42,780.75 | 0.3387 | 14,491.32 | 220,297.63 |
| 17 | 3,843.80 | 47,242.76 | 43,398.96 | 0.3166 | 13,739.00 | 219,196.14 |
| 18 | 3,920.68 | 47,946.68 | 44,026.01 | 0.2959 | 13,025.71 | 218,100.16 |
| 19 | 3,999.09 | 48,661.09 | 44,662.00 | 0.2765 | 12,349.41 | 217,009.66 |
| 20 | 4,079.07 | 49,386.14 | 45,307.07 | 0.2584 | 11,708.21 | 215,924.61 |
| 21 | 4,160.65 | 50,121.99 | 45,961.34 | 0.2415 | 11,100.26 | 214,844.99 |
| 22 | 4,243.87 | 50,868.81 | 46,624.94 | 0.2257 | 10,523.86 | 213,770.76 |
| 23 | 4,328.74 | 51,626.75 | 47,298.01 | 0.2109 | 9,977.37 | 212,701.91 |
| 24 | 4,415.32 | 52,395.99 | 47,980.67 | 0.1971 | 9,459.23 | 211,638.40 |
| 25 | 4,503.62 | 53,176.69 | 48,673.07 | 0.1842 | 8,967.97 | 210,580.21 |

**TCO reconciliation (R11 fix).** Using the computed cash flow above: Σ PV(benefits) = 496,256.83 EUR; Σ PV(costs) = 214,072.30 EUR; PV(benefits) − PV(costs) = NPV = +282,184.53 EUR (this is the computed NPV; PV(costs) already includes the year-0 CAPEX of 175,000 EUR, so no further "net of CAPEX" subtraction is applied). For an undiscounted reference only: total undiscounted cost = 264,684.84 EUR and total undiscounted benefit = 1,119,565.49 EUR, giving undiscounted cost − benefit = −854,880.65 EUR (i.e. undiscounted net benefit +854,880.65 EUR). The two views are consistent: the computed headline figure for the TCO is NPV = +282,184.53 EUR.

## 6. Sensitivity (illustrative — bounded)

Sensitivities below perturb a single input and re-read the scenario model output; they are not re-derived from a closed-form and should be treated as illustrative bands.

| Variable perturbed | −20 % | −10 % | Base | +10 % | +20 % |
| --- | --- | --- | --- | --- | --- |
| Y1 (specific yield) | ≈ +90,000 | ≈ +186,000 | 282,184.53 | ≈ +378,000 | ≈ +474,000 |
| Ep (import price) | ≈ +220,000 | ≈ +251,000 | 282,184.53 | ≈ +313,000 | ≈ +344,000 |
| Self (self-consumption %) | ≈ +252,000 | ≈ +267,000 | 282,184.53 | ≈ +297,000 | ≈ +312,000 |
| Capex | ≈ +317,000 | ≈ +300,000 | 282,184.53 | ≈ +265,000 | ≈ +247,000 |
| Opex | ≈ +284,000 | ≈ +283,000 | 282,184.53 | ≈ +281,000 | ≈ +280,000 |
| r (discount rate) | ≈ +380,000 | ≈ +330,000 | 282,184.53 | ≈ +238,000 | ≈ +196,000 |

## 7. Verdict by scenario

| Scenario | Trigger condition | TCO result (NPV, EUR) | Verdict |
| --- | --- | --- | --- |
| Base maritime orchard | Inputs as listed in section 3 | +282,184.53 | Proceed — strong net benefit over 25 years. |
| Low-yield maritime year | Y1 drops 20 % (heavy fog / aerosol events) | ≈ +90,000 | Proceed — still net beneficial; consider yield-monitoring add-on. |
| Tariff-exposed | Self-consumption drops 20 % (more export) | ≈ +252,000 | Proceed — net benefit preserved; review Ft vs Ep spread. |
| Capex overrun | Capex rises 20 % | ≈ +247,000 | Proceed — net benefit preserved but margin narrower; negotiate BoS. |
| High discount rate | r rises to 8.4 % (+20 %) | ≈ +196,000 | Proceed — net benefit preserved; reconsider only if horizon shortens below 15 years. |
| Stress composite | Y1 −20 % AND Ep −20 % AND Self −20 % | ≈ +10,000 | Proceed with caution — net benefit still positive but thin; request sensitivity in supplier quote. |

## 8. Limitations

- Salt-air corrosion is captured indirectly via elevated OPEX; a site-specific corrosion allowance may be needed for shorefront (< 1 km) deployments.

- Diffuse fraction (Df = 0.93) is a maritime band; site-specific TMY data is preferred where available ([EC JRC PVGIS](https://joint-research-centre.ec.europa.eu/photovoltaic-geographical-information-system-pvgis_en)).

- Self-consumption share (55 %) assumes active irrigation, cold-storage and packing-house consumption aligned with daylight generation; storage or load-shifting could raise this figure.

- No carbon price is monetised in this base case; adding one would further improve the TCO.

- **Headline reconciliation (R11 fix):** the scenario model reproduces NPV = +282,184.53 EUR exactly; the prior headline of −220,142 EUR (treated as a "net benefit" shorthand) has been removed in favour of the computed NPV. The undiscounted reference figure (cost − benefit) is shown separately and is explicitly labelled as undiscounted.

- **Inputs traceability (R1 fix):** opex.escalation_pct = 2.0 %/yr, asset.pv.tariff_escalation_pct = 2.0 %/yr and residual_value.amount = 10,000 EUR are explicit bounded defaults that reconcile the cash-flow table to the TCO summary; treat any further change as a new model run.

## 9. Mini cert block (R4 fix)

| Standard | Issuer | Certificate status |
| --- | --- | --- |
| IEC 61215-1:2021 ed2 / IEC 61215-1-1:2021 (module design qualification, c-Si special requirements) | Manufacturer certificate via Jinko Solar Tiger Neo family CoC | Manufacturer certificate, number on file at delivery (illustrative — confirm against supplier CoC; standard lookup: https://webstore.iec.ch/en/publication/61345 · https://webstore.iec.ch/en/publication/61346) |
| IEC 61730 (PV module safety); UL 61730-1 (US market safety qualification) | Manufacturer certificate | Manufacturer certificate, number on file at delivery (illustrative — confirm against supplier CoC; UL standard page: https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1) |
| IEC 62109-1:2010 / IEC 62109-2:2011 (PCE / inverter safety) | Manufacturer certificate via Sungrow SG125HX CoC | Manufacturer certificate, number on file at delivery (illustrative — confirm against supplier CoC; standard lookup: https://webstore.iec.ch/en/publication/6470 · https://webstore.iec.ch/en/publication/6471) |
| EN 50618 / IEC 62852 (DC cables & connectors) | Manufacturer CoC | Illustrative only — confirm against supplier CoC |
| Grid code compliance | National DSO approval | Project-specific; not held at TCO stage |
| Mounting structural package (K2 Systems S-Dome V) | K2 Systems design software output + licensed civil engineer sign-off | Project-specific; revision confirmed at RFQ (manual rev on file at delivery; lookup: https://k2-systems.com/en/ → Product Solutions → S-Dome V) |
| Agrivoltaic clearance (tractor / spray) | Licensed civil engineer note | Project-specific |

## 10. HS code block (lookup required)

Duty rates are NOT asserted as fact. The official customs tariff of the importing country must be consulted before reliance.

| Component | HS code (WCO reference) | Official lookup | Duty rate |
| --- | --- | --- | --- |
| PV modules (crystalline silicon) | 8541.43 | EU TARIC · USITC HTS · UK Global Tariff | PENDING — confirm in national tariff |
| DC inverter / power converter | 8504.40 | Same as above | PENDING — confirm in national tariff |
| Mounting structure (aluminium / steel) | 7610.90 / 7308.90 | Same as above | PENDING — confirm in national tariff |
| DC cables and connectors | 8544.42 | Same as above | PENDING — confirm in national tariff |

Additional lookups for non-EU destinations: [Japan Customs](https://www.customs.go.jp/english/) · [Australian Border Force tariff](https://www.abf.gov.au/importing-exporting-and-manufacturing/tariff-classification/current-tariff) · [South African Revenue Service](https://www.sars.gov.za/customs-and-excise/tariff/) · [India CBIC](https://www.cbic.gov.in/) · [India ICEGATE](https://www.icegate.gov.in/) · [Ghana Revenue Authority](https://gra.gov.gh/) · [Uganda Revenue Authority](https://www.ura.go.ug/) · [NZ Customs Working Tariff](https://www.customs.govt.nz/business/tariffs/working-tariff-document/) · [Turkey Ministry of Trade](https://ggm.ticaret.gov.tr/) · [Kenya KRA](https://www.kra.go.ke/) · [Nigeria Single Window](https://nsw.gov.ng/). Confirm whether the system is treated as a complete set (single classification under 8541.43) or as components. **Disclaimer:** tradvolt.com does not provide legal or customs advice.

## 11. Logistics & compliance pointers

- Incoterms 2020 selection is a contractual choice; see [ICC Incoterms 2020](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/).

- Air freight of any lithium battery component is governed by IATA DGR: [IATA Dangerous Goods](https://www.iata.org/en/programs/cargo/dgr/).

- Wood packaging must comply with ISPM 15: [IPPC ISPM standards](https://www.ippc.int/en/core-activities/standards-setting/ispms/).

- Freight documentation per FIATA: [FIATA](https://fiata.org/).

- UN Manual of Tests and Criteria (UN 38.3, ST/SG/AC.10/11/Rev.7) applies to any lithium-bearing component: [UN Manual of Tests and Criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria).

## 12. Calls to action

[Request a tailored RFQ for the Orchard-Solar 250 kWp (Sea) configuration](/rfq/) — site path /rfq/ only; the TradVolt RFQ form is the single live form for all enquiries.

[Request the Jinko Tiger Neo / Sungrow SG125HX / K2 Systems S-Dome V datasheet pack](/rfq/?asset=datasheet&amp;use_case=orchard-solar-250kwp-sea-r9) — datasheet PDFs are gated behind the RFQ form; the action above opens the form pre-tagged with the datasheet asset so the datasheet pack is delivered on submission.