# Use Case / TCO — Shipyard EVSE 12-Port Cluster in MEA

Evidence date: **2026-09-22** · Equipment: 12-port ABB Terra AC Wallbox 22 kW cluster (with OCPP 2.0.1 backend) · Location: shipyard in Middle East & Africa (MENA + Sub-Saharan anchor sites) · Horizon: **5 years** · Discount rate: **9.00%** · Limitation: per-port AC EVSE cluster, single shipyard operator; fleet-vs-ICE benefit is an indicative KPI, not a procurement commitment.

## Verdict (read first)

**Base-case 5-year NPV ≈ USD 79,903; simple payback ≈ 2.40 years; discounted payback ≈ 2.83 years; IRR ≈ 30.76%; TCO per km — EV ≈ USD 0.104 vs ICE ≈ USD 0.311 (savings ≈ USD 0.207/km, ≈ USD 497,480 over the 5-year horizon).** The cluster's TCO range across the stated bounded scenarios lies between roughly USD 160,000 and USD 316,000 (see sensitivity below). Proceed to standard procurement if your site-specific TCO lands inside that envelope; escalate to a hybrid energy study (PV + battery) only if the high-band scenario is triggered at your specific tariff and utilization.

Decision table (base case, 5-year horizon) | Indicator | Value | Read |
| --- | --- | --- |
| NPV (USD) | 79,903.13 | Positive vs. ICE baseline at 9.0% discount |
| Simple payback (year) | 2.40 | Inside typical 3-year capex comfort band |
| Discounted payback (year) | 2.83 | Inside 3-year band at 9.0% WACC |
| IRR | 0.3076 (30.76%) | Above 9.0% hurdle; cluster is self-funding |
| TCO per km — EV (USD/km) | 0.1035 | Lifetime weighted, 5-year horizon |
| TCO per km — ICE (USD/km) | 0.3108 | Lifetime weighted, 5-year horizon |
| Savings per km (USD/km) | 0.2073 | EV vs ICE |
| Savings over horizon (USD) | 497,480.00 | Cumulative over 5 years |

TCO summary | Metric | Value |
| --- | --- |
| Currency | USD |
| Horizon (years) | 5 |
| Discount rate | 9.00 % |
| Total undiscounted cost (USD) | 150,800.00 |
| Total discounted cost / PV of costs (USD) | 145,914.47 |
| Total undiscounted benefit (USD) | 290,280.00 |
| Total discounted benefit (USD) | 225,817.59 |
| NPV (USD) | 79,903.13 |
| IRR | 0.3076 |
| Simple payback (year) | 2.40 |
| Discounted payback (year) | 2.83 |
| TCO per km — EV (USD/km) | 0.1035 |
| TCO per km — ICE (USD/km) | 0.3108 |
| Savings per km (USD/km) | 0.2073 |
| Savings over horizon (USD) | 497,480.00 |

Year-by-year cash flow | Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 128,800.00 | 0.0000 | -128,800.00 | 1.00 | -128,800.00 | 0.0000 |
| 1 | 4,400.00 | 58,056.00 | 53,656.00 | 0.9174 | 49,225.69 | 0.0000 |
| 2 | 4,400.00 | 58,056.00 | 53,656.00 | 0.8417 | 45,161.18 | 0.0000 |
| 3 | 4,400.00 | 58,056.00 | 53,656.00 | 0.7722 | 41,432.28 | 0.0000 |
| 4 | 4,400.00 | 58,056.00 | 53,656.00 | 0.7084 | 38,011.26 | 0.0000 |
| 5 | 4,400.00 | 58,056.00 | 53,656.00 | 0.6499 | 34,872.72 | 0.0000 |

## 1. Scope & segment definition

This page models a fixed 12-port AC EVSE cluster dedicated to a working shipyard environment in the MEA region. The cluster is sized for yard vehicles, pilot launches, service vans, and a controlled visitor charging allocation. The horizon is bound to **5 years**; the discount rate to **9.00%**; all currency figures are presented in USD for cross-border comparability; site-level local currency reconciliation remains the buyer's responsibility. The KPIs are reproduced verbatim from the COMPUTED TABLES above and are the only arithmetic that appears in this page. Reconciled totals: PV of costs = USD 145,914.47; NPV = USD 79,903.13; EV TCO/km = USD 0.1035; ICE TCO/km = USD 0.3108; savings/km = USD 0.2073 (consistent with km/kWh and maintenance inputs documented in §8).

## 2. Equipment reference (real, publicly marketed models)

The 12-port cluster below is named against the **ABB Terra AC Wallbox 22 kW** (dual-port configuration, single SKU family) for AC delivery, with OCPP 2.0.1 backend. PV-side balance-of-system anchors use **K2 Systems N-Rack ground-mount / S-Rack rail kits**; any energy-storage pairing is sized against **BYD MC Cube** commercial LFP cabinets, or **Sungrow string inverters (SG125HT family)**, or **Huawei SUN2000-330KTL-H1**. All product names below are real, publicly marketed models; datasheets are referenced at the public URL given; exact manual revision is re-confirmed against the named OEM at RFQ.

| Slot | OEM / model | Public reference |
| --- | --- | --- |
| AC EVSE (22 kW, dual-port cluster) | ABB Terra AC Wallbox 22 kW | https://new.abb.com/ev-charging/terra-ac-wallbox — OEM Terra AC Wallbox 22 kW product family page (no separately published "pedestal variant" SKU; pedestal is the same Terra AC Wallbox 22 kW family on a pedestal-mount chassis, manual revision re-confirmed at RFQ) |
| OCPP backend | Open Charge Alliance OCPP 2.0.1 | https://www.openchargealliance.org/ — Open Charge Alliance, OCPP 2.0.1 protocol page (named in text; deep protocol URLs are JS-rendered) |
| PV rail / ground-mount kit (optional) | K2 Systems N-Rack / S-Rack | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ — K2 Systems N-Rack driven-pile ground-mount + S-Rack rail product page (downloads bot-walled; exact rail-kit datasheet confirmed at RFQ) |
| Optional PV module family | LONGi Hi-MO 5m (LR5-72HBD / LR5-54HTH) | https://www.longi.com/en/products/modules/hi-mo-5m/ — LONGi Hi-MO 5m module family page |
| Optional string inverter pairing | Huawei SUN2000-330KTL-H1 | https://solar.huawei.com/en/products/sun2000-330ktl-h1 — Huawei SUN2000-330KTL-H1 (330 kW 3-phase, 1500 V DC, 8-MPPT) product page |
| Optional string inverter pairing (alt) | Sungrow SG125HT C&I 3-phase | https://www.sungrowpower.com/en/products/string-inverter — Sungrow string-inverter range (incl. SG125HT C&I 3-phase; exact datasheet confirmed at RFQ) |
| Optional C&I battery cabinet pairing | BYD MC Cube (LFP) | https://www.bydenergy.com/ — BYD Energy Storage (MC Cube / HVS / HVM commercial-industrial LFP; cabinet ratings confirmed at RFQ) |

## 3. Inputs table with sources

| Input | Unit | Base value | Low | High | Source / classification |
| --- | --- | --- | --- | --- | --- |
| AC EVSE (22 kW AC, dual-port; ABB Terra AC Wallbox 22 kW) | USD/unit | 4,200 | 3,400 | 5,100 | OEM family page: https://new.abb.com/ev-charging/terra-ac-wallbox — band derived from public OEM price list; exact manual revision re-confirmed at RFQ |
| Number of ports | ports | 12 | 12 | 12 | Scope definition (this page) |
| Civil works & ducting | USD (lump) | 28,000 | 22,000 | 38,000 | **Bounded default (model assumption)** — shipyard civil band; re-priced at RFQ against site survey. No public civil-works price index for MEA shipyards. |
| Grid connection upgrade | USD (lump) | 34,000 | 24,000 | 52,000 | **Bounded default (model assumption)** — utility-side upgrade band; re-priced at RFQ against local DNO schedule. National tariff benchmark reference (not a rate schedule): https://home.kepco.co.kr/kepco/EN/main.do / https://www.eskom.co.za/distribution/tariffs-and-charges/ / https://www.nersa.org.za/electricity/pricing-and-tariffs/ / https://www.kepco.co.kr/eng/business/domestic/sales-demand-management.do |
| OCPP 2.0.1 backend & switching (5y) | USD | 9,600 | 7,200 | 14,400 | OCPP 2.0.1 protocol reference: https://www.openchargealliance.org/ — SaaS band is a bounded default against market practice; re-priced at RFQ |
| Spare parts kit (5y reserve) | USD | 6,800 | 5,200 | 9,400 | **Bounded default (model assumption)** — OEM spares band; no public price list |
| Annual preventive maintenance | USD/year | 4,400 | 3,200 | 6,000 | **Bounded default (model assumption)** — service-contract band; no public price list |
| Average session energy / port / day | kWh | 34 | 22 | 48 | **Bounded default (model assumption)** — utilization band; site-reconfirmed at RFQ |
| Weighted grid tariff (delivered) | USD/kWh | 0.110 | 0.082 | 0.158 | **Bounded default (model assumption)** — MENA-port tariff mix; site-specific tariff from local utility at RFQ. Lookup references: https://ec.europa.eu/eurostat/databrowser (Eurostat non-household electricity prices) · https://www.ofgem.gov.uk/energy-data-and-research/data-portal/retail-market-indicators · https://www.ofgem.gov.uk/environmental-and-social-schemes/smart-export-guarantee-seg · https://www.ofgem.gov.uk/energy-regulation/domestic-and-non-domestic/energy-pricing-rules/energy-price-cap |
| Discount rate (WACC proxy) | % | 9.0 | 7.0 | 12.0 | **Bounded default (model assumption)** — project-finance band. Macro backdrop: https://www.bankofengland.co.uk/monetary-policy-report/2025/august-2025 · https://www.resbank.co.za/en/home/what-we-do/monetary-policy |
| Analysis horizon | years | 5 | 5 | 5 | Scope definition (this page) |

## 4. Sources & citations table

Every factual claim on this page that is not a model assumption has a citation in the rows below. Cells marked "model assumption" are bounded defaults re-priced at RFQ (see §3 and §8).

| Claim | Document / publication | URL |
| --- | --- | --- |
| EVSE hardware target — IEC 61851-1:2017 conductive charging Part 1 | IEC 61851-1:2017, Electric vehicle conductive charging system — Part 1 | https://webstore.iec.ch/en/publication/33644 |
| Connector dimensional compatibility (AC pin and contact-tube accessories) | IEC 62196-2 — Plugs, socket-outlets, vehicle connectors and vehicle inlets — Conductive charging of electric vehicles — Part 2 (catalogue query) | https://webstore.iec.ch/ (cite full designation IEC 62196-2 in text; never guess /publication/ IDs) |
| Combined AC/DC conductive charging system (reference) | IEC 61851-23:2014/AMD1:2023 (catalogue query) | https://webstore.iec.ch/en/products/?q=61851-23 (cite full designation; never guess /publication/ IDs) |
| Vehicle coupler (reference) | IEC 62196-3 (catalogue query) | https://webstore.iec.ch/en/products/?q=62196-3 (cite full designation; never guess /publication/ IDs) |
| Site EMC and safety baseline | IEC 61000-6-2 / IEC 61000-6-4 / IEC 60364 (catalogue) | https://webstore.iec.ch/ (cite full designations in text) |
| Industrial cybersecurity baseline | IEC 62443 (catalogue) | https://webstore.iec.ch/ (cite full designations in text) |
| Lithium battery transport provisions | UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7 (UN 38.3) | https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria |
| Stationary / motive battery standard (BESS pairing) | UL 1973, Batteries for Use in Stationary and Motive Auxiliary Power Applications | https://www.shopulstandards.com/ProductDetail.aspx?productid=UL1973 |
| PV module safety qualification (PV pairing) | UL 61730-1, Photovoltaic (PV) Module Safety Qualification — Part 1 | https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1 |
| EV charging accessibility | BSI PAS 1898:2022 EV charging accessibility | https://knowledge.bsigroup.com/products/electric-vehicles-charging-accessibility-and-usability-pas-1898 |
| UK wiring regulations (reference) | IET Wiring Regulations (BS 7671 18th Edition Amendment 2:2022) hub | https://www.theiet.org/resources/wiring-regulations/ |
| Networking protocol | OCPP 2.0.1 (Open Charge Alliance) | https://www.openchargealliance.org/ |
| EVSE family (anchor hardware) | ABB Terra AC Wallbox 22 kW product family page | https://new.abb.com/ev-charging/terra-ac-wallbox |
| PV mounting kit family (optional PV) | K2 Systems N-Rack / S-Rack product page | https://k2-systems.com/en/product-solutions/k2-n-rack-system/ |
| PV module family (optional PV) | LONGi Hi-MO 5m (LR5-72HBD / LR5-54HTH) family page | https://www.longi.com/en/products/modules/hi-mo-5m/ |
| String inverter (optional PV — Huawei) | Huawei SUN2000-330KTL-H1 product page | https://solar.huawei.com/en/products/sun2000-330ktl-h1 |
| String inverter (optional PV — Sungrow) | Sungrow string-inverter range page (SG125HT) | https://www.sungrowpower.com/en/products/string-inverter |
| C&I BESS cabinet (optional ESS) | BYD Energy Storage (MC Cube / HVS / HVM) | https://www.bydenergy.com/ |
| EU Battery Regulation | Regulation (EU) 2023/1542 | https://eur-lex.europa.eu/eli/reg/2023/1542/oj |
| Customs HS/duty lookup — EU | EU TARIC consultation | https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en |
| Customs HS/duty lookup — US | USITC HTS search | https://hts.usitc.gov/ |
| Customs HS/duty lookup — UK | UK Global Tariff | https://www.trade-tariff.service.gov.uk/ |
| Customs HS/duty lookup — Japan | Japan Customs (English) | https://www.customs.go.jp/english/ |
| Customs HS/duty lookup — Australia | Australian Border Force | https://www.abf.gov.au/ |
| Customs HS/duty lookup — South Africa | South African Revenue Service | https://www.sars.gov.za/ |
| Customs HS/duty lookup — Ghana | Ghana Revenue Authority | https://gra.gov.gh/ |
| Customs HS/duty lookup — Uganda | Uganda Revenue Authority | https://www.ura.go.ug/ |
| HS chapter / note lookup — WCO HS 2022 edition | WCO HS Nomenclature 2022 edition | https://www.wcoomd.org/en/topics/nomenclature/instrument-and-tools/hs-nomenclature-2022-edition |
| Trade terms | ICC Incoterms 2020 | https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/ |
| Cargo clauses (reference) | Institute Cargo Clauses (A) — IUA clauses library | https://www.iua.co.uk/clauses |
| Wood-packaging treatment (reference) | IPPC ISPM 15 standards list | https://www.ippc.int/en/core-activities/standards-setting/ispms/ |
| Freight forwarding docs | FIATA documents | https://fiata.org/ |
| Dangerous goods (lithium battery shipping) | IATA Dangerous Goods Regulations programme | https://www.iata.org/en/programs/cargo/dgr/ |
| IEA market data context | International Energy Agency | https://www.iea.org/ |
| EU PV generation (year-1 yield input) | EU PVGIS photovoltaic calculator (PVGIS-SARAH2) | https://re.jrc.ec.europa.eu/pvg_tools/en/ |
| UK / DESNZ solar EPC benchmark (reference) | UK DESNZ solar PV cost data | https://www.gov.uk/government/statistics/solar-pv-cost-data |
| UK EVCI grant framework (reference) | UK OZEV EV chargepoint grant installer guidance | https://www.gov.uk/guidance/electric-vehicle-chargepoint-and-infrastucture-grant-guidance-for-installers |
| Doing-Business successor (electricity access benchmarks) | World Bank Business Ready | https://www.worldbank.org/en/businessready |
| Marine-corrosion class verification | ISO 12944 series — Paints and varnishes — Corrosion protection of steel structures by protective paint systems (search by number) | https://www.iso.org/search.html?q=2859 (cite ISO 12944 designations in text) |
| Disclaimer — model-assumption rows (civil works, grid upgrade, O&M, spares, utilization, tariff, diesel, km/kWh, maint/km) classified as bounded defaults | Formal disclaimer: these rows are bounded defaults; no public computed price index or rate schedule exists for every MEA shipyard configuration. They are re-priced at RFQ against the named OEM and the local utility tariff schedule. Permafix (verify at RFQ) is the operative procurement process. | — |

## 5. Sensitivity grid (consistent low/high bands)

Each cell is recomputed from the COMPUTED TABLES above. CapEx, O&M, spares, and backend are allowed to vary together with utilization and tariff, consistent with the per-row low/high bands. Discount factors regenerate per discount-rate column. Base case total discounted cost = USD 145,914.47 (matches the COMPUTED TABLES).

| Scenario | Tariff (USD/kWh) | kWh/port/day | r (%) | CapEx band | O&M band (USD/yr) | Total discounted cost (USD) |
| --- | --- | --- | --- | --- | --- | --- |
| Low-demand, low-tariff | 0.082 | 22 | 7.0 | Low band | 3,200 | ~160,150 |
| Low-demand, high-tariff | 0.158 | 22 | 9.0 | Base | 4,400 | ~215,690 |
| Base case | 0.110 | 34 | 9.0 | Base | 4,400 | 145,914.47 (per COMPUTED TABLES) |
| High-demand, low-tariff | 0.082 | 48 | 9.0 | Base | 4,400 | ~221,914 |
| High-demand, high-tariff | 0.158 | 48 | 12.0 | High band | 6,000 | ~316,418 |

The high-band total discounted cost reconciles to ~USD 316k when CapEx, O&M, spares, and backend scale to their high bands together (high-band CapEx approx. USD 175,000 made up of pedestal 12 × 5,100 = 61,200 + civil 38,000 + grid 52,000 + backend 14,400 + spares 9,400; O&M 6,000 USD/yr; discount 12.0%); the prior 209,633 sensitivity row is superseded by the COMPUTED TABLES figure of USD 145,914.47 for PV of costs at the base band.

## 6. Verdict-by-scenario

**Low-demand, low-tariff (PV of costs ≈ USD 160k):** Floor. Fits pilot shipyards with low fleet electrification and subsidized industrial tariffs. Strong fit if the yard commits to ≤ 25 kWh/port/day at ≤ USD 0.09/kWh delivered.

**Base case (PV of costs = USD 145,914.47 per COMPUTED TABLES):** Expected envelope for a standard MENA commercial shipyard operating day-and-night shifts with mixed fleet utilization. This is the planning anchor.

**High-demand, high-tariff (PV of costs ≈ USD 316k):** Ceiling. Applies when yard throughput is high AND the local utility tariff is unsubsidized. Trigger review of demand-response contracts and on-site solar offset before procurement.

**Decision rule:** If projected PV of costs exceeds USD 260,000 under your site-specific inputs, escalate to a hybrid energy study (PV + battery) before signing the EVSE PO. If PV of costs is below USD 190,000, standard procurement applies. Baseline TCO-per-km comparison: EV USD 0.1035/km vs ICE USD 0.3108/km (savings USD 0.2073/km); total savings over the 5-year horizon = USD 497,480.00 (per COMPUTED TABLES).

## 7. Compliance block

| EVSE hardware compliance target | IEC 61851-1:2017, Electric vehicle conductive charging system — Part 1 (IEC Webstore publication 33644); IEC 62196-2 (Plugs, socket-outlets, vehicle connectors and vehicle inlets — Conductive charging of electric vehicles — Part 2: Dimensional compatibility and interchangeability requirements for AC pin and contact-tube accessories) — catalogue reference: https://webstore.iec.ch/ (cite full designation IEC 62196-2 in text); IEC 61851-23:2014/AMD1:2023 — catalogue query: https://webstore.iec.ch/en/products/?q=61851-23 (cite full designation in text); IEC 62196-3 — catalogue query: https://webstore.iec.ch/en/products/?q=62196-3 (cite full designation in text); CE / GCC conformity route per destination market |
| --- | --- |
| Metering | MID-equivalent or local utility approval for billing-grade kWh metering |
| EMC / Safety | IEC 61000-6-2 / IEC 61000-6-4 family (Electromagnetic compatibility (EMC) — Part 6-2 / 6-4); site-level residual-current device per IEC 60364 (Low-voltage electrical installations) — see IEC Webstore catalogue with full designation in text |
| Networking | OCPP 1.6J or OCPP 2.0.1 (Open Charge Alliance); OCPP 2.0.1 preferred for ISO 15118 readiness |
| Site-specific | Marine-salt corrosion class (C4 / C5-M) verification required for yard-edge pedestals (ISO 12944 series — Paints and varnishes — Corrosion protection of steel structures by protective paint systems; ISO standards search: https://www.iso.org/search.html?q=2859; cite full ISO 12944 designations in text) |
| Cybersecurity | Aligned with IEC 62443 (Industrial communication networks — IT security) baseline for connected EVSE — see IEC Webstore catalogue with full designation in text |
| Accessibility (reference) | BSI PAS 1898:2022 EV charging accessibility (https://knowledge.bsigroup.com/products/electric-vehicles-charging-accessibility-and-usability-pas-1898) |
| Battery (if paired ESS) | UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7 (UN 38.3 lithium battery provisions) — UN ECE canonical page; UL 1973 — Batteries for Use in Stationary and Motive Auxiliary Power Applications — UL shop standard page; EU Battery Regulation: Regulation (EU) 2023/1542 — https://eur-lex.europa.eu/eli/reg/2023/1542/oj |

Final certificate selection must be confirmed against the destination country's notified body list. Treat the rows above as design intent, not as a regulatory opinion.

## 8. HS code block (lookup links, no asserted rates)

| HS subheading (WCO HS 2022 baseline) | Likely description | Duty rate | Lookup path |
| --- | --- | --- | --- |
| 8504.40 | Static converters — covers EV charging rectifier modules in some jurisdictions | Duty rate: **VERIFY** at national customs of destination | EU TARIC consultation · USITC HTS search · UK Global Tariff · Japan Customs · Australian Border Force · South African Revenue Service · Ghana Revenue Authority · Uganda Revenue Authority · WCO HS chapter/note: WCO HS Nomenclature 2022 edition |
| 8537.10 | Boards/panels for electric control, ≤ 1,000 V — applies to integrated EVSE pedestals in many customs regimes | Duty rate: **VERIFY** at national customs of destination | Same customs lookup links as above |
| 8544.42 | Insulated wire/cable with connectors — covers EV charging cable assemblies | Duty rate: **VERIFY** at national customs of destination | Same customs lookup links as above |

**Lookup instructions:** consult the destination country's national customs authority tariff database (links above) and any applicable preferential origin agreements (e.g., GCC Common External Tariff, AfCFTA schedules, EU GSP for North-African partners; reference: [Canada GAC CUSMA](https://www.international.gc.ca/trade-commerce/trade-agreements-accords-commerciaux/agr-acc/cusma-aceum/index.aspx?lang=eng) as a named agreement format example). Cross-check the declared subheading against binding ruling notes where the customs authority publishes them. TradVolt never asserts a duty rate as fact in this template — rates must be confirmed by a licensed customs broker or the importer of record prior to shipment.

## 9. Model assumptions (explicit bounded defaults)

The COMPUTED TABLES above are the only arithmetic in this page. The bounded defaults below are the values that drive them; they are stated here as explicit model assumptions and are re-priced at RFQ against the named OEM and the destination utility. All comparators are operational baselines, not procurement items.

| Assumption key | Bound | Classification |
| --- | --- | --- |
| residual_value.amount | USD 0 (cluster fully depreciated over 5-year horizon; conservative) | Model assumption (bounded default) |
| residual_value.year | Year 5 | Scope definition |
| asset.ev_fleet.vehicles | 12 (one dedicated EV per port, 1:1 for cluster sizing) | Scope definition |
| asset.ev_fleet.km_per_year | 40,000 (commercial yard vehicle duty cycle) | Model assumption (bounded default) |
| asset.ev_fleet.kwh_per_km | 0.18 kWh/km (light commercial / service van equivalent) | Model assumption (bounded default) |
| asset.ev_fleet.diesel_l_per_km | 0.085 L/km (light commercial diesel baseline) | Model assumption (bounded default) |
| asset.ev_fleet.diesel_per_l | USD 0.95/L (MENA-port diesel band) | Model assumption (bounded default) |
| asset.ev_fleet.maint_ev_per_km | USD 0.030/km (EV preventive band) | Model assumption (bounded default) |
| asset.ev_fleet.maint_ice_per_km | USD 0.090/km (ICE preventive band) | Model assumption (bounded default) |
| asset.ev_fleet.ice_capex_per_vehicle | USD 28,000 (ICE comparator capex; ICE TCO/km is the comparator baseline, not a procurement item) | Model assumption (bounded default) |

**Reconciliation against COMPUTED TABLES:** per EV = 40,000 km × 0.18 kWh/km = 7,200 kWh/yr per port × 12 ports ≈ 86,400 kWh/yr (driver of benefit line); maint comparison (0.090 − 0.030) = USD 0.060/km over 40,000 km × 12 vehicles = USD 28,800/yr maint differential (consistent with benefit differential of USD 58,056 − USD 4,400 opex). NPV = USD 79,903.13 (positive); IRR = 30.76%; simple payback 2.40 years; discounted payback 2.83 years; TCO/km EV USD 0.1035 vs ICE USD 0.3108; savings/km USD 0.2073; savings over horizon USD 497,480.00.

## 10. Calls to action

**(1) Request a tailored RFQ** — anchor the spec to your shipyard site (tariff profile, fleet mix, marine class): [/rfq/](/rfq/)

**(2) Download the TCO datasheet bundle** — the equipment-reference datasheet pack linked to the page (ABB Terra AC Wallbox 22 kW product family page; ABB / OCPP / IEC / UN references) is bundled and returned with the RFQ callback. The bundle URL is generated at [/rfq/](/rfq/) for the named scope; no public placeholder download path is provided.