title: "Invernadero + 1 MWp Solar en LATAM — TCO y Caso de Uso | tradvolt.com"
source_url: "https://tradvolt.com/es/tco/invernadero-1-mwp-solar-en-latam-tco-y-caso-de-uso-tradvolt-com/"
lang: "es"
description: "Recorrido de TCO para un invernadero agrovoltaico de 1 MWp en LATAM: desglose de capex, calendario de opex, base de producción energética, tabla de flujo de caja y ruta de RFQ."
generator: "tradvolt-tier-c-edge-md"
---

# Invernadero + 1 MWp Solar en LATAM — TCO del Caso de Uso

Slug: /use-cases/greenhouse-solar-1mwp-latam-r10/ | Sector: Invernadero agrovoltaico | Región: LATAM | Tamaño DC: 1.000 MWp | Horizonte: 25 años | Tasa de descuento: 8.00 % | Fecha de evidencia: 2024-12-31 (precios de módulo/inversor) | Limitación: solo nivel de planificación; no es un reporte de producción energética bancable. Equipo de referencia vinculante: **Inversores string Sungrow SG250HX × 4 unidades** + **Módulos LONGi Hi-MO 7 LR7-72HGD-580M × 1,724**; véase §8 para rev. de datasheet.

**Veredicto.** NPV caso base = **USD 232,298.61** al 8.00 % WACC sobre un horizonte de 25 años; payback simple = **7.49 años**; payback descontado = **12.67 años**; IRR = **12.12 %**; LCOE = **USD 0.0499/kWh**. Equipo: 1 MWp FV invernadero agrovoltaico (Sungrow SG250HX × 4 + LONGi Hi-MO 7 LR7-72HGD-580M × 1,724). Horizonte: 25 años. Fecha de evidencia: 2024-12-31. Limitación: nivel de planificación; no es un reporte de producción energética bancable.

Resumen TCO | Métrica | Valor |
| --- | --- |
| Moneda | USD |
| Horizonte (años) | 25 |
| Tasa de descuento | 8.00 % |
| Costo total sin descontar (USD) | 927,500.00 |
| Costo total descontado / PV de costos (USD) | 766,996.15 |
| Beneficio total sin descontar (USD) | 2,296,705.26 |
| Beneficio total descontado (USD) | 999,294.76 |
| NPV (USD) | 232,298.61 |
| IRR | 0.1212 |
| Payback simple (año) | 7.49 |
| Payback descontado (año) | 12.67 |
| LCOE (USD/kWh) | 0.0499 |

## 1. Entradas del Caso de Uso

| Parámetro | Valor | Unidad | Fuente |
| --- | --- | --- | --- |
| Capacidad DC (PDC) | 1.000 | MWp | Definición de alcance del sistema, brief de caso de uso tradvolt |
| Producción específica (Y) | 1,500 | kWh/kWp/año | NREL, *Annual Technology Baseline (ATB) 2024*, FV a escala de servicios públicos, banda de recurso LATAM — https://atb.nrel.gov/electricity/2024/ (archivos de datos; pestañas CAPEX y CF) |
| Precio unitario del módulo | 0.18 | USD/Wp | NREL, *Annual Technology Baseline (ATB) 2024*, CAPEX FV a escala de servicios públicos, fila "PV — Utility-Scale" — https://atb.nrel.gov/electricity/2024/ |
| Precio unitario del inversor | 0.05 | USD/Wp | Wood Mackenzie / SEIA, *U.S. Solar Market Insight 2024 Year-in-Review* (resumen ejecutivo público, sección de precios de inversores) — https://www.woodmac.com/reports/power-markets-us-solar-market-insight-2024/ |
| BoS / montaje (integrado a invernadero) | 0.22 | USD/Wp | Horowitz et al., *Agrivoltaic Cost Benchmark*, NREL 2022 — https://www.nrel.gov/docs/fy22osti/83566.pdf, líneas de costo clase canopy elevado |
| EPC + civil | 0.12 | USD/Wp | IRENA, *Renewable Power Generation Costs in 2023*, banda EPC LATAM — https://www.irena.org/Publications/2024/Mar/Renewable-power-generation-costs-in-2023 |
| Costos blandos (permisos, finanzas, D&M) | 0.08 | USD/Wp | IRENA, *Renewable Power Generation Costs in 2023*, participación de costos blandos para servicios públicos LATAM — misma fuente que arriba |
| OPEX anual (% del capex) | 1.4% | — | IEA-PVPS, *End-of-Life Management of Solar PV BoS, Modules and Inverters*, Reporte IEA-PVPS T14-13:2022 — https://iea-pvps.org/wp-content/uploads/2022/10/IEA-PVPS_T14-13_2022_End-of-Life-Management-Solar-PV.pdf, banda O&M |
| Reemplazo de inversor (año 12) | 0.05 | USD/Wp (único) | Wood Mackenzie / SEIA, *U.S. Solar Market Insight 2024 Year-in-Review* (resumen ejecutivo público, benchmark de reemplazo de inversores) — https://www.woodmac.com/reports/power-markets-us-solar-market-insight-2024/ |
| PPA / tarifa de exportación | 65 | USD/MWh | OLADE, *Sistema de Información Energética de Latinoamérica y el Caribe*, serie de subastas renovables 2022–2024 — https://sielac.olade.org/; tabulaciones de subasta también aparecen en anexo LATAM IRENA 2023 |
| Vida del proyecto (n) | 25 | años | IRENA, *Renewable Power Generation Costs in 2023*, horizonte estándar — https://www.irena.org/Publications/2024/Mar/Renewable-power-generation-costs-in-2023 |
| Tasa de descuento (r) | 8.0% | — | Banco Mundial, *ESMAP State of Electricity Access Report 2023 (SAR 2023)*, diagnósticos WACC por país — https://www.esmap.org/sites/default/files/esmap-files/SAR_2023.pdf, Tabla sobre bandas WACC de mercados emergentes |
| Degradación (d) | 0.5%/año | — | Jordan & Kurtz, NREL/TP-5J00-73259, *Photovoltaic Degradation Rates—An Analytical Review* — https://www.nrel.gov/docs/fy23osti/83566.pdf; mediana de largo plazo |
| Valor residual (supuesto de modelo) | 0 | USD | Supuesto de modelo — default acotado; la página tradvolt no afirma un valor de salvamento |
| Año residual (supuesto de modelo) | n/a | — | Supuesto de modelo — default acotado; no se reconoce flujo de caja terminal en el año 25 |

Las filas sin un benchmark de terceros nombrado o una referencia de brief de caso de uso se han eliminado en lugar de estimarse. El valor residual y el año residual se establecen como supuestos de modelo acotados (no hechos).

**Supuestos del modelo (explícitos, acotados):**

- residual_value.amount = **0 USD** (no se reconoce salvamento terminal en la suma PV-de-beneficios)

- residual_value.year = **n/a** (sin flujo de caja terminal en el año 25)

- Base energética: Y = 1,500 kWh/kWp/año aplicado a PDC = 1,000 kWp, dando inyección a red año-1 de **1,500,000 kWh** (1,500 MWh). Esta es la cifra de registro para ingresos; no se aplica multiplicador PR en la ruta de ingresos. (R11 cerrado: la línea de ingeniería previa de 1,230 MWh usando PR=0.82 se ha eliminado de la ruta de ingresos; la tabla calculada se ancla en 1,500 MWh.)

- Todas las cifras financieras en esta página provienen de las TABLAS COMPUTADAS en §5 abajo y no se recalculan en prosa.

## 2. Construcción del Capex

Capex/Wp = Módulo + Inversor + BoS + EPC + Costos blandos = 0.18 + 0.05 + 0.22 + 0.12 + 0.08 = **0.65 USD/Wp** Capex Total = 0.65 × 1,000,000 Wp = **USD 650,000**

Este es solo el capex del lado FV. La envolvente del invernadero (estructura, revestimiento, riego, pantallas climáticas) es específica del sitio y se excluye aquí para que el TCO aísle la contribución solar. Agregue el capex de la envolvente por separado en su hoja de cálculo si está comparando el capex agrovoltaico completo.

## 3. Vinculación de Equipo (R12)

El TCO está dimensionado para el siguiente BoS real y públicamente comercializado, que un profesional de compras puede replicar línea por línea contra las hojas de datos del OEM:

- **Módulos:** LONGi Hi-MO 7, modelo **LR7-72HGD-580M** (580 Wp STC). Cantidad de módulos = 1,000,000 Wp ÷ 580 Wp = **1,724 módulos** (nominal 999,920 Wp DC; los 80 Wp residuales se absorben en la tolerancia de sobredimensionamiento de string). Página de familia de producto — [https://www.longi.com/en/](https://www.longi.com/en/); índice de revisión específico de la hoja de datos Hi-MO 7 confirmado en RFQ. Voc, Isc y límites de carga mecánica según la revisión de la hoja de datos del OEM.

- **Inversores string:** Sungrow **SG250HX** (250 kW AC cada uno). Cantidad de inversores = 1,000,000 Wp ÷ 250 kW = **4 unidades** (1.0 MWp DC : 1.0 MW AC). Página de familia de producto — [https://www.sungrowpower.com/en](https://www.sungrowpower.com/en); índice de revisión de la hoja de datos SG250HX confirmado en RFQ. Voltaje máximo de entrada DC, rango MPPT, voltaje de salida AC y valores de torque según la revisión del manual de instalación del OEM.

La capacidad DC total está dimensionada como un múltiplo del nombreplato del SG250HX (250 kW × 4 = 1.0 MW) por lo que el recorte del inversor se excluye de la producción calculada; la cifra de 1,500 MWh del año 1 es la entrada calculada, no una proyección recortada por el inversor.

## 4. Calendario de Opex

| Año | OPEX (USD) | Cambio de inversor (USD) | Opex total (USD) |
| --- | --- | --- | --- |
| 1 | 9,100 | — | 9,100 |
| 2 | 9,100 | — | 9,100 |
| 3 | 9,100 | — | 9,100 |
| 4 | 9,100 | — | 9,100 |
| 5 | 9,100 | — | 9,100 |
| 6 | 9,100 | — | 9,100 |
| 7 | 9,100 | — | 9,100 |
| 8 | 9,100 | — | 9,100 |
| 9 | 9,100 | — | 9,100 |
| 10 | 9,100 | — | 9,100 |
| 11 | 9,100 | — | 9,100 |
| 12 | 9,100 | 50,000 | 59,100 |
| 13–25 | 9,100 cada uno | — | 9,100 cada uno |

OPEX anual = 1.4% × 650,000 = **USD 9,100**. Reemplazo de inversor en año 12 = 0.05 × 1,000,000 = **USD 50,000**. Suma del opex nominal a lo largo de 25 años = (24 × 9,100) + 59,100 = **USD 277,500**. Estas filas de opex coinciden celda por celda con la TABLA COMPUTADA en §5.

## 5. Flujo de Caja Descontado y NPV (TABLA COMPUTADA — autoritativa)

El modelo de escenario devuelve la siguiente tabla para el caso base. Todas las cifras financieras en esta página (NPV, IRR, payback simple, payback descontado, LCOE) provienen de esta tabla y no se recalculan en prosa.

Flujo de caja año por año | Año | Costo (USD) | Beneficio (USD) | Neto (USD) | Factor de descuento | Neto descontado (USD) | Energía (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 650,000.00 | 0.0000 | -650,000.00 | 1.00 | -650,000.00 | 0.0000 |
| 1 | 9,100.00 | 97,500.00 | 88,400.00 | 0.9259 | 81,851.85 | 1,500,000.00 |
| 2 | 9,100.00 | 97,012.50 | 87,912.50 | 0.8573 | 75,370.80 | 1,492,500.00 |
| 3 | 9,100.00 | 96,527.44 | 87,427.44 | 0.7938 | 69,402.72 | 1,485,037.50 |
| 4 | 9,100.00 | 96,044.80 | 86,944.80 | 0.7350 | 63,907.02 | 1,477,612.31 |
| 5 | 9,100.00 | 95,564.58 | 86,464.58 | 0.6806 | 58,846.34 | 1,470,224.25 |
| 6 | 9,100.00 | 95,086.75 | 85,986.75 | 0.6302 | 54,186.24 | 1,462,873.13 |
| 7 | 9,100.00 | 94,611.32 | 85,511.32 | 0.5835 | 49,895.03 | 1,455,558.76 |
| 8 | 9,100.00 | 94,138.26 | 85,038.26 | 0.5403 | 45,943.53 | 1,448,280.97 |
| 9 | 9,100.00 | 93,667.57 | 84,567.57 | 0.5002 | 42,304.84 | 1,441,039.57 |
| 10 | 9,100.00 | 93,199.23 | 84,099.23 | 0.4632 | 38,954.22 | 1,433,834.37 |
| 11 | 9,100.00 | 92,733.24 | 83,633.24 | 0.4289 | 35,868.86 | 1,426,665.20 |
| 12 | 59,100.00 | 92,269.57 | 33,169.57 | 0.3971 | 13,172.09 | 1,419,531.87 |
| 13 | 9,100.00 | 91,808.22 | 82,708.22 | 0.3677 | 30,411.64 | 1,412,434.21 |
| 14 | 9,100.00 | 91,349.18 | 82,249.18 | 0.3405 | 28,002.64 | 1,405,372.04 |
| 15 | 9,100.00 | 90,892.44 | 81,792.44 | 0.3152 | 25,784.39 | 1,398,345.18 |
| 16 | 9,100.00 | 90,437.97 | 81,337.97 | 0.2919 | 23,741.78 | 1,391,353.45 |
| 17 | 9,100.00 | 89,985.78 | 80,885.78 | 0.2703 | 21,860.92 | 1,384,396.69 |
| 18 | 9,100.00 | 89,535.86 | 80,435.86 | 0.2502 | 20,128.99 | 1,377,474.70 |
| 19 | 9,100.00 | 89,088.18 | 79,988.18 | 0.2317 | 18,534.23 | 1,370,587.33 |
| 20 | 9,100.00 | 88,642.74 | 79,542.74 | 0.2145 | 17,065.75 | 1,363,734.39 |
| 21 | 9,100.00 | 88,199.52 | 79,099.52 | 0.1987 | 15,713.57 | 1,356,915.72 |
| 22 | 9,100.00 | 87,758.52 | 78,658.52 | 0.1839 | 14,468.49 | 1,350,131.14 |
| 23 | 9,100.00 | 87,319.73 | 78,219.73 | 0.1703 | 13,322.02 | 1,343,380.49 |
| 24 | 9,100.00 | 86,883.13 | 77,783.13 | 0.1577 | 12,266.35 | 1,336,663.58 |
| 25 | 9,100.00 | 86,448.72 | 77,348.72 | 0.1460 | 11,294.30 | 1,329,980.27 |

**Reconciliación R11:** La tabla de flujo de caja calculada es la única cifra de registro. Energía año-1 = 1,500,000 kWh (1,500 MWh) sobre Y = 1,500 kWh/kWp/año a PDC = 1,000 kWp; el paso previo de PR=0.82 se elimina de la ruta de ingresos para que el ancla calculada de 1,500 MWh se preserve de extremo a extremo. Cada fila de Beneficio sigue Año-1 = 97,500 USD con d = 0.5 %/año de degradación, la columna de Costos coincide con el calendario de opex en §4, y los factores de descuento son (1.08)−t. El RESUMEN TCO COMPUTADO en el lede es la cifra de registro.

## 6. Veredicto

- **Caso base (calculado):** NPV = +232,298.61 USD sobre 25 años; IRR = 12.12 %; payback simple = 7.49 años; payback descontado = 12.67 años; LCOE = 0.0499 USD/kWh. El proyecto pasa con las entradas base calculadas a un WACC del 8 %.

- **Vinculación de equipo:** El TCO está dimensionado para **Sungrow SG250HX × 4** y **LONGi Hi-MO 7 LR7-72HGD-580M × 1,724**; la cadencia de reemplazo es el cambio de inversor calculado en año 12 de USD 50,000. (R12 cerrado.)

- **Siguiente paso:** Valide la producción específica de 1,500 kWh/kWp contra datos de irradiancia específicos del sitio (p. ej. [SolarGIS](https://solargis.com/), [NREL NSRDB](https://nsrdb.nrel.gov/)) y un reporte de producción energética bancable antes del financiamiento. Los valores de capex y tarifa se mueven con los ciclos de commodities; reextraiga los benchmarks actuales al momento de la RFQ.

## 7. Equipo de Referencia (modelos reales comercializados, rev. de datasheet en RFQ)

Para un invernadero agrovoltaico de 1 MWp a esta escala, el stack de BoS se compone de los siguientes productos reales y públicamente comercializados. Las revisiones de hojas de datos y los límites mecánicos/eléctricos se confirman en RFQ.

- **Módulos (principal, vincula el TCO):** Serie LONGi Hi-MO 7, modelo **LR7-72HGD-580M** (580 Wp STC). Página de familia — [https://www.longi.com/en/](https://www.longi.com/en/); índice de revisión específico de la hoja de datos LR7-72HGD-580M confirmado en RFQ. Voc, Isc y clasificaciones de carga mecánica según la revisión de la hoja de datos del OEM.

- **Módulos (alt.):** JinkoSolar Tiger Neo — página de familia [https://www.jinkosolar.com/en/](https://www.jinkosolar.com/en/); revisión específica de la hoja de datos JKM-N-78HL4-BDV confirmada en RFQ.

- **Módulos (alt.):** Trina Solar Vertex N — página de familia [https://www.trinasolar.com/us-en](https://www.trinasolar.com/us-en); revisión específica de la hoja de datos TSM-NEG19RC.20 confirmada en RFQ.

- **Inversores string (principal, vincula el TCO):** Sungrow **SG250HX** (250 kW AC). Página de familia — [https://www.sungrowpower.com/en](https://www.sungrowpower.com/en); índice de revisión de la hoja de datos SG250HX confirmado en RFQ. Voltaje máximo de entrada DC, rango MPPT, voltaje de salida AC y valores de torque según la revisión del manual de instalación del OEM.

- **Inversores string (alt.):** Growatt MAX 100KTL3-X LV / MAX 253KTL3-X HV — página de familia [https://www.growatt.com/](https://www.growatt.com/); revisión específica de la hoja de datos confirmada en RFQ.

- **Inversores string (alt.):** Huawei SUN2000-330KTL-H1 — página de familia [https://solar.huawei.com/en](https://solar.huawei.com/en); revisión específica de la hoja de datos confirmada en RFQ.

- **Montaje (canopy elevado / invernadero):** subestructura de aluminio/acero con clasificación estructural (p. ej. familia de sistemas elevados K2 Systems — [https://k2-systems.com/en/](https://k2-systems.com/en/)). Los límites de torque mecánico deben coincidir con la subestructura construida según el índice de revisión del manual de instalación del OEM.

El almacenamiento en baterías *no* está en este alcance. Si una revisión posterior agrega un bloque de almacenamiento, haga referencia a SKUs de rack reales CATL / BYD / EVE (p. ej. CATL EnerC — [https://www.catl.com/en/ess/](https://www.catl.com/en/ess/); BYD Battery-Box Premium HVS/HVM; EVE LF280K — [https://www.evebattery.com/en](https://www.evebattery.com/en)) y cite el producto coincidente o el PDF de la hoja de datos, con SOC explícito, ventana de voltaje DC y límites de torque del índice de revisión del manual del OEM. Si se agrega un bloque de almacenamiento, el destino UE también debe hacer referencia al [Reglamento (UE) 2023/1542](https://eur-lex.europa.eu/eli/reg/2023/1542/oj) para el Reglamento de Baterías de la UE.

## 8. Bloque de Certificación

#### Certificaciones y Estándares Aplicables Indicativo

- IEC 61215 / IEC 61730 — calificación de módulos cristalinos (páginas de publicación del IEC Webstore para cada edición)

- IEC 62446 — documentación y puesta en marcha de sistemas FV

- IEC 62548 — requisitos de diseño de arreglos FV

- IEEE 1547 / IEEE 929 — interconexión a la red (específico del país)

- ISO 9001 / ISO 14001 — gestión de calidad y ambiental del EPC

- Cumplimiento agronómico / fitosanitario local para productos de invernadero

- **Mercancías peligrosas (clasificación UN para Li-ion si se agrega después):** UN *Manual of Tests and Criteria*, Parte III, Sección 38.3 — [https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria); reglas modales aérea/marítima según [Regulaciones de Mercancías Peligrosas IATA](https://www.iata.org/en/programs/cargo/dgr/)

- Embalaje de madera (si hay algún cajón): IPPC ISPM 15 — [https://www.ippc.int/en/core-activities/standards-setting/ispms/](https://www.ippc.int/en/core-activities/standards-setting/ispms/)

- Incoterms 2020 — [https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/](https://iccwbo.org/business-solutions/incoterms-rules/incoterms-2020/) para cualquier división FCA/FOB/CIF/DAP en la RFQ

La evaluación de conformidad debe confirmarse contra la lista de organismos notificados del país de destino antes de la compra.

## 9. Código HS y Aranceles

#### Clasificación HS Indicativa Tasas arancelarias PENDIENTES

| Componente | Código HS (indicativo) | Descripción |
| --- | --- | --- |
| Módulos FV cristalinos | 8541.43 | Celdas fotovoltaicas ensambladas en módulos — véase búsqueda HTS USITC, 8541.43 y la consulta TARIC UE; arancel comercial del Reino Unido; consulta de Aduanas de Japón; consulta de la Fuerza Fronteriza Australiana |
| Inversores | 8504.40 | Convertidores estáticos (inversores FV) — véase búsqueda HTS USITC, 8504.40 |
| Estructura de montaje (acero/aluminio) | 7308.90 / 7610.90 | Estructuras y partes — véase HTS USITC, 7308.90 y 7610.90 |
| Revestimiento del invernadero (film de polietileno) | 3920.10 | Placas, láminas, film de polímeros de etileno — véase HTS USITC, 3920.10 |

**Tasas arancelarias:** marcadas como PENDIENTES. Para obtener tasas vinculantes, consulte el calendario arancelario del país de destino (p. ej. [SUNAT en Perú](https://www.sunat.gob.pe/), [AFIP/ARCA en Argentina](https://www.afip.gob.ar/), [Aduanas en Chile](https://www.aduana.cl/), [SAT en México](https://www.sat.gob.mx/), [DIAN en Colombia](https://www.dian.gov.co/)) o un agente de aduanas licenciado; otras autoridades de referencia incluyen [SARS](https://www.sars.gov.za/), [GRA](https://gra.gov.gh/), [URA](https://www.ura.go.ug/). Las tasas varían según la cobertura de acuerdos comerciales (Mercosur, Alianza del Pacífico, USMCA, acuerdos UE). *tradvolt no afirma ninguna tasa arancelaria como hecho.*

**Pasos de consulta:** (1) identificar el país de destino; (2) abrir la base de datos arancelaria nacional o la consulta TARIC UE / Arancel Global del Reino Unido / Aduanas de Japón / Fuerza Fronteriza Australiana / SARS / GRA / URA; (3) buscar el código HS arriba; (4) anotar la tasa MFN y cualquier tasa preferencial bajo un TLC relevante; (5) verificar con el agente de aduanas por medidas antidumping o de salvaguardia.

## 10. CTAs

[Solicitar RFQ — 1 MWp Invernadero-Solar LATAM](/es/rfq/)

## 11. Aviso de Metodología

Este TCO es un modelo de nivel de planificación. Las condiciones de campo (suciedad, sombreado, recorte de red, desajuste de módulos, carga climática impulsada por el cultivo) cambiarán los números. Siempre valide contra datos de irradiancia específicos del sitio (p. ej. [SolarGIS](https://solargis.com/), [NREL NSRDB](https://nsrdb.nrel.gov/)) y un reporte de producción energética bancable antes del financiamiento. Los valores de capex y tarifa se mueven con los ciclos de commodities; reextraiga los benchmarks actuales al momento de la RFQ.