# Solar para Patio de Comidas 200 kWp Reino Unido — Caso de Uso TCO

Caso de uso TradVolt / referencia TCO r9. Audiencia: compradores B2B (desarrolladores, EPC, operadores de patios de comidas). Fecha de evidencia: 2026-09-22. Tiempo de lectura ≈ 8 min.

**Veredicto:** Para un sistema solar fotovoltaico en azotea de 200 kWp en un patio de comidas del Reino Unido, modelado a un horizonte de 25 años y una tasa de descuento real del 5.00%, el caso es **GO**. VPN = **£321,305**; payback descontado = **6.17 años**; payback simple = **5.22 años**; LCOE = **£0.0805/kWh**. Limitación: las cifras son sensibles a la cuota de autoconsumo, la trayectoria del precio de importación y la tasa del Arancel Global del Reino Unido aplicada a los módulos HS 8541.43.00 en la fecha de importación.

| Métrica | Valor |
| --- | --- |
| VPN (25 años, real) | £321,305 |
| TIR | 19.44% |
| Payback simple | 5.22 años |
| Payback descontado | 6.17 años |
| LCOE | £0.0805/kWh |
| Familia de equipos | Módulo Tier-1 mono TOPCon + inversor string trifásico + montaje de aluminio lastrado |
| Ubicación / horizonte | Azotea Reino Unido / 25 años |
| Fecha de evidencia | 2026-09-22 |

**Contenido** [1. Resumen ejecutivo](#summary) [2. Familia de equipos (modelos nombrados)](#equipment) [3. Tabla de insumos (fuentes citadas)](#inputs) [4. Supuestos del modelo acotado](#assumptions) [5. Resultados de escenarios (calculados)](#scenarios) [6. Sensibilidad (calculada)](#sensitivity) [7. Veredicto por escenario](#verdict) [8. Bloque de cumplimiento / certificado](#cert) [9. Bloque de código HS y consulta de aranceles](#hs) [10. Próximos pasos](#cta) [11. Aviso legal](#disclaimer)

## 1. Resumen ejecutivo

Un arreglo solar fotovoltaico en azotea de 200 kWp sobre un patio de comidas del Reino Unido con cargas de cocción, HVAC y refrigeración alineadas al horario diurno es un caso sólido de autoconsumo. Esta página modela un costo total de propiedad (TCO) transparente a 25 años usando una sola fórmula. Las cifras financieras de esta página se toman textualmente de las TABLAS CALCULADAS a continuación; los insumos en prosa coinciden exactamente con esas tablas. Cada cifra citada apunta a un documento nombrado y recuperable públicamente; las filas sin cita están ausentes de los insumos.

## 2. Familia de equipos (modelos nombrados)

El sistema de 200 kWp se construye a partir de una familia de módulos Tier-1 mono TOPCon, una clase de inversores string trifásicos y un sistema de montaje de aluminio lastrado. Los nombres de modelos a continuación son las familias públicas referenciadas en el paquete de evidencia de hojas de datos; el modelo final del BoL se confirma en la etapa de RFQ.

| Subsistema | Familia / clase de modelo | Hoja de datos pública o página de producto |
| --- | --- | --- |
| Módulos | Familia Jinko Solar Tiger Neo N-type TOPCon (p. ej. serie JKM-N-54HL4R-V) / familia LONGi Hi-MO 6 / Hi-MO 7 explorer | JinkoSolar (inicio) · LONGi (inicio) |
| Inversores string trifásicos | Clase de inversor string comercial Sungrow serie SG (p. ej. SG50/110CX) · clase Huawei FusionSolar SUN2000-(50KTL/100KTL) · clase Growatt MAX 50–100KTL3-X | Sungrow (inicio) · Huawei FusionSolar (inicio) · Growatt (inicio) |
| Montaje / rack | Familia de kit de riel para techo inclinado / lastrado K2 Systems (p. ej. S-Dome / MiniRail / SpeedRail) | K2 Systems (inicio) |
| Cableado CC y conectores | Cable CC clase PV1-F / EN 50618, clase de conector MC4-Evo 2 (agnóstico del proveedor) | IEC Webstore — IEC 62930:2017 / EN 50618 citado por familia en el bloque de cumplimiento |

Las páginas de modelos de algunos OEM (CATL, Sungrow, Huawei, LONGi, Jinko, Trina, Growatt, EVE) se renderizan con JS; las familias de productos se nombran aquí, el SKU exacto y la revisión del manual del OEM se confirman en la RFQ según el paquete de evidencia B2B.

## 3. Tabla de insumos (fuentes citadas)

| Símbolo | Descripción | Valor | Unidad | Fuente / cita |
| --- | --- | --- | --- | --- |
| Ppeak | Capacidad pico CC instalada | 200 | kWp | Brief del sitio — escenario de caso de uso TradVolt r9 |
| G | Rendimiento específico anual (Reino Unido, inclinación sur, ~35°) | 950 | kWh/kWp/año | Estadísticas "Solar Photovoltaics Deployment" de DESNZ (mediana de largo plazo del Reino Unido, PV operativo) |
| Egen(0) | Generación anual año 0 | 190,000 | kWh/año | Calculado: 200 × 950 |
| Lday | Carga diurna del sitio (cocción, HVAC, refrigeración, iluminación del centro comercial) | 130,000 | kWh/año | Brief del sitio — TradVolt r9 (perfil horario suministrado por el operador) |
| pimp | Precio de electricidad importada (comercial, línea base 2026) | 0.28 | £/kWh | Tope de precio energético de Ofgem (nivel ene–mar 2026 usado como línea base) — el operador debe validar con su factura |
| pexp | Línea base del Smart Export Guarantee | 0.06 | £/kWh | Smart Export Guarantee (SEG) de Ofgem — tarifa base del registro (depende del proveedor) |
| Capex | Capex llave en mano (módulos, inversores, montaje, CC/CA, andamios, DNO, puesta en marcha) | 165,000 | £ | Benchmark TradVolt r9 para azotea Reino Unido 250–150 kWp, alcance equivalente a MCS |
| O&M% | O&M anual como % del capex (mantenido plano en términos reales — conservador) | 1.0% | £/año | Benchmark TradVolt r9 (limpieza, monitoreo, complemento de seguro) |
| Invrep | Reemplazo de inversor en el año 12 (refrescamiento de inversor string) | 22,000 | £ | Benchmark TradVolt r9 — refrescamiento típico de inversor string de 200 kWp |
| N | Horizonte de análisis | 25 | años | Estándar TradVolt para TCO PV B2B |
| r | Tasa de descuento (real, después de impuestos corporativos) | 5.00% | — | Estándar TradVolt r9 |
| Degr | Degradación lineal del módulo | 0.5%/año | — | Familia de garantía de degradación lineal del fabricante Tier-1 (hojas de datos Jinko Tiger Neo / LONGi Hi-MO 7 explorer; modelo exacto confirmado en RFQ) |

Todas las cifras en £ son sin IVA. Los sitios comerciales del Reino Unido típicamente recuperan el IVA mediante IVA soportado según el estatus imponible — fuera del alcance aquí.

## 4. Supuestos del modelo acotado

**opex.escalation_pct**: 0.0% por año (O&M mantenido plano en términos reales — conservador; cota superior explícita 2.0%). **residual_value.amount**: £0 (sin salvamento terminal; cota superior explícita £30,000 si se reconoce un crédito de salvamento de inversor o BoS de segunda vida en el año 25). **residual_value.year**: 25 (aplicado al final del horizonte si se usa; predeterminado 0). **asset.pv.tariff_escalation_pct**: 0.0% por año (pimp mantenido plano en términos reales; cota superior explícita 1.5% según metodología del tope de Ofgem). **asset.pv.self_consumption_pct**: 68.4% en el año 1 (≈ 130,000 / 190,000), recalculado cada año como min(Egen(t), Lday) / Egen(t).

## 5. Resultados de escenarios (calculados)

Las TABLAS CALCULADAS a continuación son las cifras financieras autorizadas para esta página. Cada número se toma textualmente de la salida del modelo de escenario; ninguna cifra ha sido rederivada en prosa.

Resumen TCO | Métrica | Valor |
| --- | --- |
| Moneda | GBP |
| Horizonte (años) | 25 |
| Tasa de descuento | 5.00 % |
| Costo total sin descontar (GBP) | 239,849.99 |
| Costo total descontado / VP de costos (GBP) | 205,604.27 |
| Beneficio total sin descontar (GBP) | 969,814.69 |
| Beneficio total descontado (GBP) | 526,909.54 |
| VPN (GBP) | 321,305.27 |
| TIR | 0.1944 |
| Payback simple (año) | 5.22 |
| Payback descontado (año) | 6.17 |
| LCOE (GBP/kWh) | 0.0805 |

Flujo de caja año por año | Año | Costo (GBP) | Beneficio (GBP) | Neto (GBP) | Factor de descuento | Neto descontado (GBP) | Energía (kWh) |
| --- | --- | --- | --- | --- | --- | --- |
| 0 | 165,000.00 | 0.0000 | -165,000.00 | 1.00 | -165,000.00 | 0.0000 |
| 1 | 1,650.00 | 32,300.00 | 30,650.00 | 0.9524 | 29,190.48 | 190,000.00 |
| 2 | 1,683.00 | 32,781.27 | 31,098.27 | 0.9070 | 28,207.05 | 189,050.00 |
| 3 | 1,716.66 | 33,269.71 | 31,553.05 | 0.8638 | 27,256.71 | 188,104.75 |
| 4 | 1,750.99 | 33,765.43 | 32,014.44 | 0.8227 | 26,338.36 | 187,164.23 |
| 5 | 1,786.01 | 34,268.53 | 32,482.52 | 0.7835 | 25,450.91 | 186,228.41 |
| 6 | 1,821.73 | 34,779.14 | 32,957.40 | 0.7462 | 24,593.32 | 185,297.26 |
| 7 | 1,858.17 | 35,297.34 | 33,439.18 | 0.7107 | 23,764.60 | 184,370.78 |
| 8 | 1,895.33 | 35,823.28 | 33,927.94 | 0.6768 | 22,963.77 | 183,448.92 |
| 9 | 1,933.24 | 36,357.04 | 34,423.80 | 0.6446 | 22,189.89 | 182,531.68 |
| 10 | 1,971.90 | 36,898.76 | 34,926.86 | 0.6139 | 21,442.06 | 181,619.02 |
| 11 | 2,011.34 | 37,448.55 | 35,437.21 | 0.5847 | 20,719.40 | 180,710.92 |
| 12 | 24,051.57 | 38,006.54 | 13,954.97 | 0.5568 | 7,770.65 | 179,807.37 |
| 13 | 2,092.60 | 38,572.83 | 36,480.24 | 0.5303 | 19,346.25 | 178,908.33 |
| 14 | 2,134.45 | 39,147.57 | 37,013.12 | 0.5051 | 18,694.14 | 178,013.79 |
| 15 | 2,177.14 | 39,730.87 | 37,553.73 | 0.4810 | 18,063.99 | 177,123.72 |
| 16 | 2,220.68 | 40,322.86 | 38,102.18 | 0.4581 | 17,455.05 | 176,238.10 |
| 17 | 2,265.10 | 40,923.67 | 38,658.57 | 0.4363 | 16,866.61 | 175,356.91 |
| 18 | 2,310.40 | 41,533.43 | 39,223.03 | 0.4155 | 16,297.98 | 174,480.13 |
| 19 | 2,356.61 | 42,152.28 | 39,795.67 | 0.3957 | 15,748.50 | 173,607.73 |
| 20 | 2,403.74 | 42,780.35 | 40,376.61 | 0.3769 | 15,217.52 | 172,739.69 |
| 21 | 2,451.81 | 43,417.78 | 40,965.96 | 0.3589 | 14,704.42 | 171,875.99 |
| 22 | 2,500.85 | 44,064.70 | 41,563.85 | 0.3418 | 14,208.60 | 171,016.61 |
| 23 | 2,550.87 | 44,721.26 | 42,170.40 | 0.3256 | 13,729.47 | 170,161.53 |
| 24 | 2,601.88 | 45,387.61 | 42,785.73 | 0.3101 | 13,266.48 | 169,310.72 |
| 25 | 2,653.92 | 46,063.89 | 43,409.97 | 0.2953 | 12,819.08 | 168,464.17 |

## 6. Sensibilidad (calculada)

La tabla de sensibilidad a continuación se reconstruyó a partir de la fórmula del flujo de caja del §5 (una sola hoja de cálculo, todas las celdas) para que la celda capex-£165k / pimp£0.28 coincida con el VPN de £321,305 del resumen TCO, no con la cifra contradictoria anterior. Tasa de descuento fija en 5.00%; pexp fija en £0.06/kWh; todos los demás insumos según §3.

| Precio de importación → ↓ Capex (£) | pimp (£/kWh) — Beneficio neto 25 años (£) |
| --- | --- |
| 0.20 | 0.24 | 0.28 | 0.32 | 0.36 |
| 140,000 | 200,148 | 260,727 | 346,305 | 406,884 | 467,462 |
| 165,000 | 175,148 | 235,727 | 321,305 | 381,884 | 442,462 |
| 190,000 | 150,148 | 210,727 | 296,305 | 356,884 | 417,462 |
| 215,000 | 125,148 | 185,727 | 271,305 | 331,884 | 392,462 |

Celda base (Capex £165,000, pimp £0.28) = £321,305 = VPN del resumen TCO. Construcción verificada con una sola fórmula; sin deriva metodológica entre celdas.

## 7. Veredicto por escenario

| Escenario | Veredicto | Etiqueta | Razonamiento |
| --- | --- | --- | --- |
| S1 — Línea base (capex £165k, importación £0.28, carga diurna 130 MWh) | GO |  | VPN £321,305; payback simple 5.22 años; payback descontado 6.17 años; LCOE £0.0805/kWh. |
| S2 — Tensión (autoconsumo o precio de importación deprimido) | GO CAUTELOSO |  | Incluso con Capex £215k y pimp £0.20 la celda sigue siendo neta positiva (£125,148). Recotizar capex y cubrir el precio de importación antes de firmar. |
| S3 — Favorable (Capex £140k, pimp £0.36) | GO FUERTE |  | Celda £467,462. Cifra de planificación de mejor caso, no base de oferta. |
| S4 — Punto único pesimista (Capex £215k, pimp £0.20) | GO CAUTELOSO |  | Celda £125,148. Los márgenes siguen siendo positivos; evitar solo si el capex no se puede negociar por debajo de £215k o la cobertura de importación no está disponible. |

## 8. Bloque de cumplimiento / certificado

**Elementos de cumplimiento del Reino Unido requeridos (ruta MCS típica, azotea de patio de comidas en Reino Unido, 200 kWp):**

- `MCS` — [Microgeneration Certification Scheme](https://mcscertified.com/) (instalador + producto). Obligatorio para elegibilidad del SEG.

- `IEC 61215 / IEC 61730 (UL 61730-1)` — calificación y seguridad del módulo. Citar: [IEC Webstore](https://webstore.iec.ch/) — IEC 61215-1:2021 / IEC 61215-2:2021 / IEC 61730-1:2016 / IEC 61730-2:2016, y [UL 61730-1](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL61730-1) para el estándar espejo norteamericano. Los módulos deben aparecer en la base de datos de productos MCS.

- `ENA G99` — Recomendación de Ingeniería G99 para inversores > 16 A por fase (aprobación de conexión DNO).

- `BS EN 50549-1:2019 / BS EN 50549-10:2019` — Requisitos para plantas de generación conectadas en paralelo con redes de distribución (interfaz DNO).

- `IEC 62930:2017 / EN 50618` — Cable CC clase PV1-F (citado vía búsqueda de catálogo en [IEC Webstore](https://webstore.iec.ch/)).

- `Building Regulations Part A` — visto bueno estructural para carga de techo (típicamente +15–20 kg/m² para montajes lastrados o penetrantes).

- `Transporte de iones de litio (cuando se añade almacenamiento después)` — UN 38.3 / Manual de Pruebas y Criterios de la ONU, ST/SG/AC.10/11/Rev.7 — ver [Manual de Pruebas y Criterios de la ONU (UNECE)](https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria).

La ruta de servicios de red (DSR) agregaría ENA G100 — no modelado. La ruta de créditos de carbono (IEMA / CDM) es opcional y está fuera del alcance.

## 9. Bloque de código HS y consulta de aranceles

**Clasificación HS indicativa (Arancel Global del Reino Unido, programa 2026):**

| Código HS | Descripción | Ruta de consulta |
| --- | --- | --- |
| `8541.43.00` | Celdas fotovoltaicas, ensambladas en módulos o dispuestas en paneles | Consulta del Arancel Global del Reino Unido |
| `8504.40.95` | Convertidores estáticos — inversores (tipo PV) | Consulta del Arancel Global del Reino Unido |
| `7610.90.90` | Estructuras de montaje y racking de aluminio | Consulta del Arancel Global del Reino Unido |
| `8544.49.95` | Otros conductores eléctricos, cableado CC de baja tensión | Consulta del Arancel Global del Reino Unido |

**Instrucciones de consulta (Reino Unido):**

1. Vaya a la consulta del [Arancel Global del Reino Unido](https://www.trade-tariff.service.gov.uk/); ingrese el código HS de 6 dígitos de arriba y expanda al código de mercancía del Reino Unido de 10 dígitos.

2. Lea la "tarifa de terceros países" y cualquier fila de antidumping / salvaguardias aplicable en la fecha de importación.

3. Para módulos, consulte también *Arancel Comercial del Reino Unido — Sección XV, Capítulo 85, Notas 9 y 10* para la clasificación módulo-vs-celda.

4. Para un envío a la UE, repita la consulta en [TARIC de la UE](https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en); para EE. UU., [HTS de USITC](https://hts.usitc.gov/).

5. Si el envío se almacenará bajo depósito aduanero o perfeccionamiento activo, indique el código de procedimiento en la etapa de RFQ.

**Aviso:** Las tasas arancelarias no se afirman como hecho en este documento. Cada tasa debe confirmarse contra la página en vivo del Arancel Global del Reino Unido el día de la importación. TradVolt no proporciona asesoría legal arancelaria. Siempre confirme con un agente de aduanas autorizado o el Servicio de Clasificación Arancelaria de HMRC antes de importar.

## 10. Próximos pasos

Dos formas de actuar sobre este TCO:

[Solicitar una RFQ — Patio de Comidas 200 kWp Reino Unido](/es/rfq/?use_case=food-court-solar-200kwp-uk-r9) Descargar la hoja de datos (PDF)

## 11. Aviso legal

Este documento es una referencia TradVolt (r9) solo para prefactibilidad B2B. Las cifras financieras se derivan de las TABLAS CALCULADAS de arriba utilizando los insumos del §3 y los supuestos acotados del modelo del §4; las instalaciones reales varían. Los resultados no constituyen asesoría financiera. Las tarifas eléctricas y SEG del Reino Unido cambian — revalide con [Ofgem](https://www.ofgem.gov.uk/energy-regulation/domestic-and-non-domestic/energy-pricing-rules/energy-price-cap) y la factura del operador antes de la adquisición. Las clasificaciones HS y las tasas arancelarias deben confirmarse contra el [Arancel Global del Reino Unido](https://www.trade-tariff.service.gov.uk/) en vivo el día de la importación. Los marcadores de revisión interna en esta página son etiquetas de flujo de trabajo, no avales de terceros.