# AC Destination & Workplace EVSE (11 kW / 22 kW / 43 kW) vs DC Fast Chargers (120 kW / 180 kW): Hardware Specs & TCO Comparison

## Executive Verdict (Answer-First Summary)

**Vehicle dwell time, onboard AC charger limits, and daily kWh throughput — not hardware unit price — determine whether an EV charging deployment achieves positive NPV.**  For multi-hour residential, workplace, and hotel parking (4–10 hours dwell), **11 kW and 22 kW Mode 3 AC wallboxes** deliver the lowest capital risk: a **Sungrow AC011E-01 (11 kW, 400 V / 16 A)** starts at **€430 FOB China (€3,000 total installed CapEx, €333/yr OpEx)** and achieves a **0.18-year simple payback** and **+€63,177.03 5-year NPV** in a Danish residential complex (**€0.0874/km EV TCO vs €0.4490/km ICE**) , while a **Schneider Electric EVlink Pro AC EVB3S22N4A (22 kW, 32 A 3P+N)** at a Finnish hotel destination site yields **€0.0800/km EV TCO vs €0.2660/km ICE** (**+€53,410.72 20-year NPV** on the bounded benefit model) .

Conversely, **43 kW three-phase AC chargers (Starcharge EVDC43-EU, $2,400 FOB / $4,330 landed CapEx, $447/yr OpEx)** face limited vehicle-side 43 kW AC onboard rectifier adoption; in a low-utilization Nigerian parking garage scenario ($460/yr benefit), the unit returns a negative **25-year NPV of -$5,084.90 with no payback** despite a **$0.1283/km EV vs $0.2290/km ICE** vehicle cost . When fleet turnover requires sub-hour charging across **200–1,000 V DC** traction packs, **120 kW and 180 kW integrated CCS2 DC fast chargers ($65,000 landed/installed CapEx)** dominate: the **Sungrow IDC120E (120 kW)** at **600 kWh/day** highway-service throughput in Georgia achieves a **0.48-year simple payback** and **+$1,371,368.03 25-year NPV** (**$0.0542/km EV vs $0.2055/km ICE**) , while the **Sungrow IDC180E (180 kW)** at **800 kWh/day** in a Turkish fleet depot returns a **1.69-year simple payback**, **58.67% IRR**, and **+$322,628.25 25-year NPV** (**$0.0681/km EV vs $0.2180/km ICE**) .

## 1. Architectural Boundary: Mode 3 AC vs Mode 4 Integrated DC Charging

Per the [Tradvolt EV charging TCO methodology](/methods/ev-charging-tco/), charger hardware is only one component of total site cost alongside electrical connection capacity, civil works, back-office operation, and utilization . Choosing between AC and DC power classes hinges on where AC-to-DC rectification occurs:

- **Mode 3 AC Conductive Charging (11 kW, 22 kW, 43 kW — IEC 61851-1:2017 & IEC 62196-2:2022 ed. 3):**  The EVSE supplies three-phase 380–415 V AC (up to 480 V AC / 63 A three-phase under IEC 62196-2 Type 2)  directly to the vehicle's onboard charger (OBC). Because passenger EVs typically cap their OBC at 11 kW (16 A/phase) or 22 kW (32 A/phase), stepping up to a 43 kW AC charger (63 A/phase) only benefits commercial vehicles equipped with 43 kW AC onboard rectifiers.

- **Mode 4 DC Fast Charging (120 kW, 180 kW — IEC 61851-1:2017, IEC 61851-23, IEC 62196-3 CCS2 & ISO 15118):**   Stacked AC/DC rectifier modules inside the cabinet convert three-phase grid power into **200–1,000 V DC** at **≥95% peak efficiency**, bypassing the vehicle OBC and feeding the traction battery via dual CCS2 cables . Both AC and DC units classify under **HS 8504.40** (e.g., CN **8504.40.55.00** in EU TARIC or **8504.40 / 8504.90**)  .

## 2. Side-by-Side Technical Specification Table (11 kW to 180 kW)

Technical Specifications: AC (11 kW / 22 kW / 43 kW) vs Integrated DC (120 kW / 180 kW) EVSE         | Specification | Sungrow AC011E-01 (11 kW AC) | Schneider EVB3S22N4A (22 kW AC) | Starcharge EVDC43-EU (43 kW AC) | Sungrow IDC120E (120 kW DC) | Sungrow IDC180E (180 kW DC) |
| --- | --- | --- | --- | --- | --- |
| Corpus Dossier | CN → Denmark Residential | CN → Finland Hotel | CN → Nigeria Garage | CN → Georgia Highway | CN → Turkey Depot |
| Rated Power & Envelope | 11 kW AC (3P, 400 V, 16 A, Mode 3) | 22 kW AC (3P+N, 32 A, Mode 3) | 43 kW AC (3P Mode 3; up to 480 VAC / 63 A) | 120 kW DC; 200–1,000 V DC; ≥95% eff. | 180 kW DC continuous; CCS2 envelope |
| Connector & Protection | Type 2 (IEC 62196-2); IP65; 6 mA DC leakage; 12 kg class | 380–415 V AC T2S shuttered socket; RCD-DD 6 mA + iID 40 A 30 mA Type A-SI + MNx; IK10/IP55 | Type 2 (IEC 62196-2:2022 ed. 3) | Dual CCS2 DC fast charging; IP65/IK10 | CCS2 (IEC 62196-3); air/liquid-cooled SKU options |
| Protocols & Network | OCPP 1.6J (JSON), SIM / Wi-Fi | OCPP 1.6J JSON, dual Ethernet + Modbus / cellular | OCPP 1.6 / 2.0.1, cellular SIM | ISO 15118-1, OCPP 1.6 / 2.0.1, OTA | ISO 15118 (PLC), OCPP 1.6J / 2.0.1, 4G/Wi-Fi |
| Standards & HS Code | CE (LVD/EMC/RED/RoHS), IEC 61851-1; CN 8504.40.55.00 | CE, IEC 61851-1:2017, IEC 62196-2:2022 | IEC 61851-1, SONCAP/MANCAP; HS 8504.40/90 | IEC 61851-1, ISO 15118-1, CE; HS 8504.40 | CE, IEC 61851-1/-23, EN 55011; HS 8504.40/90 |

## 3. Landed CapEx, Annual OpEx, Payback, and Fleet TCO/km Comparison

Financial and TCO Comparison: AC Wallboxes/Post Chargers vs Integrated DC Fast Chargers         | Financial Metric | 11 kW AC (DK, EUR) | 22 kW AC (FI, EUR) | 43 kW AC (NG, USD) | 120 kW DC (GE, USD) | 180 kW DC (TR, USD) |
| --- | --- | --- | --- | --- | --- |
| FOB China Unit Price | €430.00 | PENDING at RFQ | $2,400.00 ($2,870 CIF) | In $65,000 CapEx | In $65,000 CapEx |
| Installed CapEx (Year 0) | **€3,000.00 / point** | €0.0000 default | **$4,330.00 / unit** | **$65,000.00 / unit** | **$65,000.00 / unit** |
| Year-1 OpEx | **€333.00 / yr** (+2%/yr) | €0.0000 default (8-yr life) | **$447.00 / yr** (+2%/yr) | **$4,500.00 / yr** (+2%/yr) | **$12,000.00 / yr** (+2%/yr) |
| Throughput & Benefit | 250 kWh/mo; €16,920/yr | €5,440.00/yr benefit | $460.00/yr benefit | 600 kWh/day; $139,900/yr | 800 kWh/day; $50,560/yr |
| Horizon & Discount Rate | 5 yr / 8.00% | 20 yr / 8.00% | 25 yr / 8.00% | 25 yr / 8.00% | 25 yr / 8.00% |
| PV of Total Costs | €4,379.63 | €0.0000 default | $9,995.29 | $122,033.16 | $217,088.43 |
| Net Present Value (NPV) | **+€63,177.03** | **+€53,410.72** | **-$5,084.90** | **+$1,371,368.03** | **+$322,628.25** |
| Simple / Disc. Payback | **0.18 yr** / 0.20 yr | 0.00 yr (artefact) | **None (—)** | **0.48 yr** / 0.52 yr | **1.69 yr** / 1.89 yr (58.67% IRR) |
| TCO/km (EV vs ICE) | **€0.0874** vs €0.4490 | **€0.0800** vs €0.2660 | **$0.1283** vs $0.2290 | **$0.0542** vs $0.2055 | **$0.0681** vs $0.2180 |

## 4. Decision Guide: When to Choose 11/22 kW AC vs 43 kW AC vs 120/180 kW DC

### Choose 11 kW / 22 kW AC When:

Vehicles park for 4–12 hours at residential complexes, offices, or hotels, and existing 16 A or 32 A three-phase distribution avoids transformer upgrades.

### Avoid 43 kW AC Unless:

You operate a captive fleet confirmed to carry 63 A three-phase onboard AC rectifiers; otherwise, passenger EVs derate a 43 kW AC post down to 11–22 kW.

### Choose 120 kW / 180 kW DC When:

Commercial vans, buses, or highway-service fleets require 30–60 minute turnarounds and daily energy throughput exceeds 600–800 kWh per charger.

### 4.1 11 kW and 22 kW AC Destination & Workplace Chargers (Low CapEx, Dwell-Driven)

In residential and hotel parking, low hardware CapEx insulates operators against utilization swings. In the [Denmark 11 kW residential model](/en/tco/import-evse-ac-11kw-from-china-to-denmark-residential-complex-tco-sungrow-ac011e-01-reference-tradvolt/), the Sungrow AC011E-01 costs **€430.00 FOB China**, sitting inside a **€3,000.00/point** installed CapEx allocation (including **€850.00** electrical installation, **€45.00** sea freight, and **€120.00** brokerage) and **€333.00/socket/yr** OpEx . For hotels needing vandal resistance (**IK10 / IP55**) and built-in protection (**RCD-DD 6 mA DC + 30 mA Type A-SI + MNx trip**), the [Schneider Electric EVlink Pro AC EVB3S22N4A 22 kW](/en/tco/evse-ac-22-kw-schneider-evlink-pro-ac-evb3s22n4a-finland-hotel-destination-charger-tco-landed-cost-illustrative-tradvolt/) doubles AC speed while holding EV cost to **€0.0800/km vs €0.2660/km ICE** (saving **€148,800.00** over 20 years) .

### 4.2 The 43 kW Three-Phase AC Trap Under Low Utilization

The [Nigeria 43 kW parking-garage study](/en/tco/import-evse-ac-43kw-starcharge-evdc43-eu-from-china-to-nigeria-parking-garage-43-kw-tco-landed-cost-tradvolt/) shows why higher AC power ratings do not guarantee returns. Importing a **Starcharge EVDC43-EU (43 kW AC)** entails **$2,400 FOB hardware** (**$2,870 CIF** with OCPP, spares, and freight) and **$4,330.00 total landed/installed CapEx**, plus **$447.00/yr Year-1 OpEx** (+2.00%/yr) . At a low **$460.00/yr** benefit stream, escalating OpEx overtakes benefit in Year 3 (**$465.06 vs $460.00**), resulting in a **-$5,084.90 NPV** and no payback .

### 4.3 120 kW and 180 kW Integrated DC Fast Chargers (High-Throughput Fleet Duty)

Stepping up to a **120 kW or 180 kW integrated DC charger** raises Year-0 CapEx to **$65,000.00** and Year-1 OpEx to **$4,500.00/yr** in the [Georgia Sungrow IDC120E highway model](/en/tco/import-120-kw-dc-evse-sungrow-idc120e-from-china-to-georgia-highway-service-fleet-tco/) (with **$6,500** Year-8/16 refurbishment) or **$12,000.00/yr** in the [Turkey Sungrow IDC180E depot model](/en/tco/import-sungrow-idc180e-dc-evse-from-china-to-turkey-fleet-depot-tco-tradvolt/)  . Serving high-mileage fleets (**600 kWh/day** / **$139,900.00/yr** benefit in Georgia; **800 kWh/day** / **$50,560.00/yr** benefit in Turkey), they pay back in **0.48 years** and **1.69 years** respectively  .

## 5. Related EVSE TCO Dossiers & Methodology Guides

- [Import EVSE AC 11kW from China to Denmark — Residential-Complex TCO (Sungrow AC011E-01)](/en/tco/import-evse-ac-11kw-from-china-to-denmark-residential-complex-tco-sungrow-ac011e-01-reference-tradvolt/)

- [EVSE AC 22 kW — Schneider EVlink Pro AC EVB3S22N4A — Finland Hotel Destination Charger TCO](/en/tco/evse-ac-22-kw-schneider-evlink-pro-ac-evb3s22n4a-finland-hotel-destination-charger-tco-landed-cost-illustrative-tradvolt/)

- [Import EVSE-AC-43kW (Starcharge EVDC43-EU) from China to Nigeria — Parking-Garage 43 kW TCO](/en/tco/import-evse-ac-43kw-starcharge-evdc43-eu-from-china-to-nigeria-parking-garage-43-kw-tco-landed-cost-tradvolt/)

- [Import 120 kW DC EVSE (Sungrow IDC120E) from China to Georgia — Highway-Service Fleet TCO](/en/tco/import-120-kw-dc-evse-sungrow-idc120e-from-china-to-georgia-highway-service-fleet-tco/)

- [Import Sungrow IDC180E 180 kW DC EVSE from China to Turkey — Fleet Depot TCO](/en/tco/import-sungrow-idc180e-dc-evse-from-china-to-turkey-fleet-depot-tco-tradvolt/)

- [How EV Charging TCO Is Modelled — Tradvolt Methodology](/methods/ev-charging-tco/)