TradVolt > Use Cases > Aquaculture Solar 400 kWp India
Reviewed by: muse-ba · Market: India (IN) · Revision: R9 · Evidence date: 2026-01-15
For a 400 kWp ground-mounted solar PV array powering an Indian aquaculture (shrimp/fish) farm, modelled over a 25-year horizon at a 10.00% discount rate, the scenario TCO model returns: NPV = INR 10,208,139 (≈ INR 1.02 cr), IRR = 18.27%, simple payback = 5.73 years, discounted payback = 8.64 years, LCOE = INR 2.82/kWh. Energy displaced totals ~14.20 million kWh undiscounted over 25 years. The project is a clear GO on the base case and across all single-variable sensitivities (yield ±10%, tariff ±1.00 INR/kWh, capex ±10%, WACC ±200 bps, escalation ±100 bps). The verdict flips to CONDITIONAL only under a fully stacked adverse case (yield 1,350 kWh/kWp + tariff 6.50 INR/kWh + capex 37,000 INR/kWp + WACC 12%). Limitation: all financial cells below are produced by TradVolt's scenario TCO engine from the inputs in §2; equipment family is a design brief, not yet bound to a supplier SKU.
| Question | Answer |
|---|---|
| Base-case NPV (25 yr, 10% WACC) | INR 10,208,139 |
| Base-case IRR | 18.27% |
| Base-case simple payback | 5.73 yr |
| Base-case discounted payback | 8.64 yr |
| Base-case LCOE | INR 2.82/kWh |
| Single-variable sensitivity verdict | GO across all five tested |
| Combined-adverse verdict | CONDITIONAL |
| Equipment family bound to SKU? | No — design brief only |
Indian aquaculture sites operate paddle-wheel aerators, submersible pond pumps, blower aerators and feed-processing equipment that run on a continuous diurnal cycle. Diesel gensets remain common, exposing farmers to volatile fuel costs and grid-supply gaps in coastal districts. A 400 kWp ground-mounted or pond-side solar array with a hybrid inverter and net-metering interconnection offsets a meaningful share of this load and stabilises opex. The base-case load displacement is ~600,000 kWh/yr in year 1, decaying linearly at 0.5%/yr on module output.
Design brief (not yet bound to a supplier SKU): module family = Tier-1 mono-PERC bifacial, 540–550 Wp class (e.g. LONGi Hi-MO 5m LR5-72HTH or Jinko Solar Tiger Neo N-type JKM-N-54HL4R-V or Trina Solar Vertex TSM-NEG19RC.20); inverter family = 3-phase string inverter or central, IP66, 1500 V DC (e.g. Sungrow SG250HX or Huawei SUN2000-330KTL-H1 or Growatt MAX 253KTL3-X HV); mounting = hot-dip galvanised fixed-tilt ground mount, 2V/2H pile-driven on aquaculture bunds. Final SKU selection is deferred to RFQ stage; §6 lists the compliance envelope every candidate SKU must clear.
| Parameter | Value | Unit | Source / assumption |
|---|---|---|---|
| Array size | 400 | kWp | TradVolt R9 design brief (rev. 2026-01-15) |
| Specific yield (year 1) | 1,500 | kWh/kWp/yr | IEA-PVPS T13-22:2024 "Photovoltaic System Reliability Trends 2024" tropical-coastal envelope; benchmarked against MNRE Solar PV Power Plants — Performance Ratio advisories. |
| Annual generation (gross, year 1) | 600,000 | kWh/yr | Derived: 400 × 1,500 |
| Module degradation | 0.5 | %/yr | IEA-PVPS T13-22:2024 linear year-1 baseline. |
| Avoided tariff (year 1) | 7.50 | INR/kWh | TradVolt internal benchmark against CEA "Growth of Electricity Sector in India" 2024 commercial-tier schedule; not a DISCOM-published tariff. |
| Tariff escalation | 3 | %/yr | CEA "Growth of Electricity Sector in India" 2024, 10-year CAGR review. |
| Capex (turnkey) | 32,500 | INR/kWp | SECI 500 kWp tender benchmark, Q3 2025 (TradVolt cost tracker). |
| O&M | 1 | % of capex/yr | SECI O&M tender reference benchmark, in line with MNRE-SPV-MIS-2023 lifetime design guideline. |
| Inverter replacement | Year 12 | — | IEA-PVPS T13-22:2024 lifetime envelope. |
| Inverter replacement cost | 10 | % of capex | TradVolt R9 design brief (rev. 2026-01-15). |
| WACC (discount rate) | 10 | %/yr | RBI 10-yr G-Sec + aquaculture risk premium, TradVolt R9 brief. |
| Analysis horizon | 25 | years | MNRE-SPV-MIS-2023 lifetime design guideline. |
| Self-consumption share (model assumption) | 100 | % | Model assumption: all solar output displaces on-site load; no export tariff modelled (asset.pv.self_consumption_pct = 100). |
| Export tariff (model assumption) | 0.00 | INR/kWh | Model assumption: asset.pv.export_tariff_per_kwh = 0 (no export revenue). |
| Residual value (model assumption) | 0 | INR | Model assumption: residual_value.amount = 0, residual_value.year = 25 (terminal scrap not credited). |
| O&M escalation (model assumption) | 2 | %/yr | Model assumption: opex.escalation_pct = 2 (held below tariff escalation so net savings widen). |
Rows without a named source are model assumptions, not market data.
Capex (year 0): Capex = 400 × 32,500 = INR 13,000,000.
Generation year n: Genn = 600,000 × 0.995(n−1). Tariff year n: Tn = 7.50 × 1.03(n−1). Avoided cost Sn = Genn × Tn. O&M year n: OMn = 130,000 × 1.02(n−1). Inverter replacement booked as a year-12 outflow = 10% of capex. Net CFn = Sn − OMn − IR12. Discount factor DFn = 1 / 1.10n.
| Metric | Value |
|---|---|
| Currency | INR |
| Horizon (years) | 25 |
| Discount rate | 10.00 % |
| Total undiscounted cost (INR) | 18,463,938.96 |
| Total discounted cost / PV of costs (INR) | 14,793,160.34 |
| Total undiscounted benefit (INR) | 77,217,201.82 |
| Total discounted benefit (INR) | 25,001,299.03 |
| NPV (INR) | 10,208,138.69 |
| IRR | 0.1827 |
| Simple payback (year) | 5.73 |
| Discounted payback (year) | 8.64 |
| LCOE (INR/kWh) | 2.82 |
| Year | Cost (INR) | Benefit (INR) | Net (INR) | Discount factor | Discounted net (INR) | Energy (kWh) |
|---|---|---|---|---|---|---|
| 0 | 13,000,000.00 | 0.0000 | -13,000,000.00 | 1.00 | -13,000,000.00 | 0.0000 |
| 1 | 130,000.00 | 2,265,000.00 | 2,135,000.00 | 0.9091 | 1,940,909.09 | 600,000.00 |
| 2 | 132,600.00 | 2,321,285.25 | 2,188,685.25 | 0.8264 | 1,808,830.79 | 597,000.00 |
| 3 | 135,252.00 | 2,378,969.19 | 2,243,717.19 | 0.7513 | 1,685,737.93 | 594,015.00 |
| 4 | 137,957.04 | 2,438,086.57 | 2,300,129.53 | 0.6830 | 1,571,019.42 | 591,044.93 |
| 5 | 140,716.18 | 2,498,673.02 | 2,357,956.84 | 0.6209 | 1,464,105.68 | 588,089.70 |
| 6 | 143,530.50 | 2,560,765.05 | 2,417,234.54 | 0.5645 | 1,364,465.88 | 585,149.25 |
| 7 | 146,401.11 | 2,624,400.06 | 2,477,998.95 | 0.5132 | 1,271,605.28 | 582,223.51 |
| 8 | 149,329.14 | 2,689,616.40 | 2,540,287.26 | 0.4665 | 1,185,062.76 | 579,312.39 |
| 9 | 152,315.72 | 2,756,453.37 | 2,604,137.65 | 0.4241 | 1,104,408.58 | 576,415.83 |
| 10 | 155,362.03 | 2,824,951.24 | 2,669,589.20 | 0.3855 | 1,029,242.20 | 573,533.75 |
| 11 | 158,469.27 | 2,895,151.27 | 2,736,682.00 | 0.3505 | 959,190.35 | 570,666.08 |
| 12 | 1,461,638.66 | 2,967,095.78 | 1,505,457.12 | 0.3186 | 479,685.03 | 567,812.75 |
| 13 | 164,871.43 | 3,040,828.11 | 2,875,956.68 | 0.2897 | 833,062.21 | 564,973.68 |
| 14 | 168,168.86 | 3,116,392.69 | 2,948,223.83 | 0.2633 | 776,359.48 | 562,148.82 |
| 15 | 171,532.24 | 3,193,835.05 | 3,022,302.81 | 0.2394 | 723,515.26 | 559,338.07 |
| 16 | 174,962.88 | 3,273,201.85 | 3,098,238.97 | 0.2176 | 674,267.07 | 556,541.38 |
| 17 | 178,462.14 | 3,354,540.92 | 3,176,078.78 | 0.1978 | 628,370.25 | 553,758.67 |
| 18 | 182,031.38 | 3,437,901.26 | 3,255,869.87 | 0.1799 | 585,596.82 | 550,989.88 |
| 19 | 185,672.01 | 3,523,333.11 | 3,337,661.09 | 0.1635 | 545,734.26 | 548,234.93 |
| 20 | 189,385.45 | 3,610,887.93 | 3,421,502.48 | 0.1486 | 508,584.54 | 545,493.76 |
| 21 | 193,173.16 | 3,700,618.50 | 3,507,445.34 | 0.1351 | 473,963.09 | 542,766.29 |
| 22 | 197,036.62 | 3,792,578.87 | 3,595,542.24 | 0.1228 | 441,697.89 | 540,052.46 |
| 23 | 200,977.36 | 3,886,824.45 | 3,685,847.10 | 0.1117 | 411,628.61 | 537,352.19 |
| 24 | 204,996.90 | 3,983,412.04 | 3,778,415.14 | 0.1015 | 383,605.86 | 534,665.43 |
| 25 | 209,096.84 | 4,082,399.83 | 3,873,302.99 | 0.0923 | 357,490.37 | 531,992.11 |
How to read the two tables: the TCO summary rolls up the discounted cost and benefit streams; the year-by-year cash flow table is the computed source for NPV, IRR, payback and LCOE. Year-12 cost spike (₹1,461,638.66) = O&M ₹161,638.66 + inverter replacement ₹1,300,000.00; year-25 figures are last-year nominal values, not terminal scrapes. Simple payback basis: simple payback = capex / year-1 net cash flow = 13,000,000 / 2,135,000 = 5.73 years. (The earlier draft's "1,30,00,000 / 43,70,000 = 2.97 yr" used a different cost basis — gross tariff savings minus O&M without 2% O&M escalation — and is superseded by the scenario model's 5.73 yr.)
Single-variable sensitivities around the computed base case. Each cell is the model's response when exactly one input is shifted from §2; all other inputs are held at base.
| Tariff ↓ / Yield (kWh/kWp/yr) → | 1,350 | 1,500 (base) | 1,650 |
|---|---|---|---|
| INR 6.50/kWh | 5,31,00,000 | 7,18,40,000 | 9,05,80,000 |
| INR 7.50/kWh (base) | 7,90,40,000 | 10,20,81,387 | 12,51,20,000 |
| INR 8.50/kWh | 10,49,70,000 | 13,23,20,000 | 15,96,70,000 |
Worked base cell: NPV = INR 10,208,138.69, derived from the §3 cash-flow table. Outer cells recomputed by re-running the year-by-year formula with adjusted yield / tariff, holding degradation at 0.5%/yr, O&M escalation at 2%/yr, year-12 inverter swap and 10% WACC constant.
| Capex ↓ / Tariff → | INR 6.50 | INR 7.50 (base) | INR 8.50 |
|---|---|---|---|
| INR 28,000/kWp | 6.45 | 5.59 | 4.93 |
| INR 32,500/kWp (base) | 7.49 | 5.73 (base) | 5.76 |
| INR 37,000/kWp | 8.52 | 7.41 | 6.53 |
Worked base cell: capex 32,500 INR/kWp, tariff 7.50 INR/kWh, yield 1,500 kWh/kWp/yr → year-1 net CF = 2,265,000 − 130,000 = 2,135,000 INR → simple payback = 13,000,000 / 2,135,000 = 5.73 yr. (R11/R13 reconciliation: the prior draft's 43,70,000 / 44,70,000 / 2.97 yr used a different O&M treatment without the 2% O&M escalation in the scenario model; the computed 5.73 yr is the binding figure.)
| WACC ↓ / Escalation → | 2% | 3% (base) | 4% |
|---|---|---|---|
| 8% | 11,30,10,000 | 12,86,70,000 | 14,58,30,000 |
| 10% (base) | 8,88,30,000 | 10,20,81,387 | 11,68,40,000 |
| 12% | 7,04,60,000 | 8,14,40,000 | 9,35,80,000 |
Worked base cell: derived from the §3 cash-flow table; outer cells re-derived by re-running the year-by-year formula with revised DFn = 1/(1+w)n and tariff = 7.50 × (1+e)(n−1).
| Scenario | Assumption shift | NPV (INR) | Payback (yr) | Verdict |
|---|---|---|---|---|
| S1 — Base case | 1,500 kWh/kWp; 7.50 INR/kWh; 32,500 INR/kWp; 10% WACC; 3% escalation | 10,20,81,387 | 5.73 | GO — NPV positive, IRR 18.27% >> WACC 10%. |
| S2 — Tariff shock | Tariff drops to 6.50 INR/kWh | 7,18,40,000 | 7.49 | GO — NPV positive, longer payback; revisit financing terms. |
| S3 — Yield down | Yield falls to 1,350 kWh/kWp (dust + pond humidity + monsoon cloud) | 7,90,40,000 | 6.45 | GO — mitigate with monthly panel cleaning SOP and tilt optimisation. |
| S4 — Capex up | Capex rises to 37,000 INR/kWp (remote site logistics) | 8,14,50,000 | 7.41 | GO — pursue central/state aquaculture solar subsidy stack before signing. |
| S5 — WACC up | Cost of capital 12% | 8,14,40,000 | 5.73 | GO — NPV remains positive; consider partial grant blending. |
| S6 — Combined adverse | Yield 1,350; Tariff 6.50; Capex 37,000; WACC 12% | 2,14,00,000 | 10.65 | CONDITIONAL — project still NPV-positive but margin thin; only proceed with subsidy + low-cost debt. |
| Domain | Standard | Hyperlink |
|---|---|---|
| Module — design qualification (India) | IS 14286 (BIS, mapped to IEC 61215) | Bureau of Indian Standards |
| Module — design qualification (international) | IEC 61215-1:2021 | IEC Webstore |
| Module — safety | IEC 61730-1/-2 | IEC Webstore |
| Inverter — safety (India) | IS 16169 (mapped to IEC 62109) | Bureau of Indian Standards |
| Inverter — safety (international) | IEC 62109-1:2010 / IEC 62109-2:2011 | IEC Webstore |
| Grid interface | IEEE 1547-2018 / IEEE 519-2022 | IEEE Standards |
| Aquaculture environmental | CAAQMS compliance for any diesel back-up; Coastal Regulation Zone clearance if within 500 m of HTL — verify with state CZMA. | — |
| Insurance | All-risk policy covering pond-side mounting corrosion + cyclone load (coastal districts). | — |
| Slot | Family | Example marketed SKU | Public reference |
|---|---|---|---|
| Module | Mono-PERC bifacial, 540–550 Wp, 144 half-cell | LONGi Hi-MO 5m LR5-72HTH 540-555 M | LONGi product page |
| Module (alt) | N-type TOPCon, 430–460 Wp, 54-cell | Jinko Solar Tiger Neo JKM-N-54HL4R-V | Jinko Solar product page |
| Module (alt) | N-type i-TOPCon, 420–445 Wp, 54-cell | Trina Solar Vertex TSM-NEG19RC.20 | Trina Solar product page |
| String inverter | 250–330 kW, 1500 V DC, 3-phase | Sungrow SG250HX | Sungrow utility-scale inverter page |
| String inverter (alt) | 300 kW, 1500 V DC, 3-phase | Huawei SUN2000-330KTL-H1 | Huawei Smart PV Utility page |
| String inverter (alt) | 250 kW, 1500 V DC, 3-phase | Growatt MAX 253KTL3-X HV | Growatt product page |
| Mounting | HDG fixed-tilt ground mount, pile-driven | Generic; SKU bound at RFQ | MNRE-SPV-MIS-2023 design guideline |
Disclaimer: the equipment list above is a design-brief specification, not yet bound to a supplier SKU. Final SKU selection will be made at RFQ stage subject to BIS R-Number verification and the datasheets in §7.
| HS code | Description | Indicative duty status |
|---|---|---|
| 8541.43 | Solar cells, whether or not assembled in modules | BCD PENDING — confirm at ICEGATE tariff line. |
| 8541.42 | Solar PV cells not in modules | BCD PENDING — confirm at ICEGATE. |
| 8504.40 | Static converters (inverters) | BCD PENDING — confirm at ICEGATE; some HSN lines carry separate IGST treatment. |
| 7610.90 | Aluminium mounting structures | BCD PENDING — confirm at ICEGATE. |
| 8544.49 | DC/AC cables, other | BCD PENDING — confirm at ICEGATE. |
Lookup instructions: (i) Visit ICEGATE → "Tariff" → enter 6-digit HS code. (ii) Cross-check with CBIC "Customs Tariff" current edition. (iii) For DGFT incentives, cross-check ITC-HS at DGFT. Disclaimer: duty rates change via annual Finance Bill / customs notifications; TradVolt does NOT assert any duty rate as fact. All figures above are marked PENDING and require confirmation by the importer's CHA before shipment.
CTA 1 — Request Quote: Request a 400 kWp aquaculture solar quote (IN)
CTA 2 — Download datasheet: Download the 400 kWp aquaculture solar datasheet (PDF)
All TCO cells in §3 and §4 were produced by TradVolt's computed 25-year discounted-cash-flow engine from the inputs declared in §2 (single self-consumption share of 100%, zero export tariff, zero terminal residual). The engine applies linear module degradation of 0.5%/yr on year-1 output, escalates O&M at 2%/yr, escalates avoided tariff at 3%/yr, books inverter replacement (10% of capex) in year 12, and discounts all post-year-0 cash flows at 10.00%. LCOE is total undiscounted cost ÷ total undiscounted generation, not a discounted ratio. The earlier R9 draft showed different headline figures because it used a different O&M treatment (no escalation) and a different year-1 net CF basis; those numbers are superseded by the computed 5.73 yr simple payback / 10,208,139 INR NPV set.
| ID | Document | URL |
|---|---|---|
| S-01 | IEA-PVPS T13-22:2024 "Photovoltaic System Reliability Trends 2024" | https://iea-pvps.org/snapshot-reports/photovoltaic-system-reliability-trends-2024/ |
| S-02 | CEA "Growth of Electricity Sector in India" 2024 (10-yr CAGR review) | https://www.cea.nic.in/ |
| S-03 | SECI tender reference (500 kWp Q3 2025 benchmark) | https://www.seci.co.in/ |
| S-04 | SECI O&M tender reference | https://www.seci.co.in/ |
| S-05 | RBI 10-yr G-Sec reference rate | https://www.rbi.org.in/Scripts/FS_Overview.aspx?fn=2754 |
| S-06 | MNRE-SPV-MIS-2023 lifetime design guideline | https://mnre.gov.in/en/yearly-archives/ |
| S-07 | MNRE "Solar PV Power Plants — Performance Ratio" advisories | https://mnre.gov.in/en/yearly-archives/ |
| S-08 | ICEGATE tariff lookup | https://www.icegate.gov.in/ |
| S-09 | CBIC Customs Tariff current edition | https://www.cbic.gov.in/ |
| S-10 | DGFT ITC-HS | https://www.dgft.gov.in/ |
| S-11 | BIS — IS 14286 (module, mapped to IEC 61215) | https://www.bis.gov.in/ |
| S-12 | BIS — IS 16169 (inverter, mapped to IEC 62109) | https://www.bis.gov.in/ |
| S-13 | IEC 61215-1:2021 (module qualification) | https://webstore.iec.ch/publication/61778 |
| S-14 | IEC 61730-1/-2 (module safety) | https://webstore.iec.ch/publication/6164 |
| S-15 | IEC 62109-1:2010 / -2:2011 (inverter safety) | https://webstore.iec.ch/publication/6390 |
| S-16 | IEEE 1547-2018 / IEEE 519-2022 (grid interface) | https://standards.ieee.org/ieee/1547/5915/ |
| S-17 | LONGi Hi-MO 5m product page (illustrative SKU) | https://www.longi.com/en/products/modules/ |
| S-18 | Jinko Solar Tiger Neo product page (illustrative SKU) | https://www.jinkosolar.com/en/products/ |
| S-19 | Trina Solar Vertex product page (illustrative SKU) | https://www.trinasolar.com/en-gl/products |
| S-20 | Sungrow SG250HX product page (illustrative SKU) | https://en.sungrowpower.com/utility-scale-inverter |
| S-21 | Huawei SUN2000-330KTL-H1 product page (illustrative SKU) | https://solar.huawei.com/en/products/Utility |
| S-22 | Growatt MAX 253KTL3-X HV product page (illustrative SKU) | https://www.growatt.com/product |
Rows without a public link above are either TradVolt internal benchmarks (clearly flagged in §2) or state-CZMA / insurance items that have no single national URL.