Verdict (base case, 25-yr horizon, 7.00% real discount rate, evidence dated 2026-01-15): A 150 kWp commercial rooftop PV system at an Australian botanical garden returns NPV ≈ AUD 430,238, with a simple payback of 4.53 years, a discounted payback of 5.61 years, and an LCOE of AUD 0.1077/kWh. Limitation: figures assume Sydney/Perth/Brisbane TMY envelope, 0.70 self-use share, 0.32 AUD/kWh retail, 0.05 AUD/kWh FiT, 0.005/yr module degradation from year 2 onward, 1.2% of capex annual OPEX, and tariff escalation fixed at zero (model assumption).
| Decision metric | Value | Status |
|---|---|---|
| NPV (AUD, 25 yr @ 7%) | 430,237.63 | Positive — proceed |
| IRR | 22.83% | Above 7% hurdle — proceed |
| Simple payback | 4.53 years | Strong |
| Discounted payback | 5.61 years | Strong |
| LCOE (AUD/kWh) | 0.1077 | Below retail 0.32 — proceed |
| Net capex (AUD) | 229,500.00 | 150 kWp × (1.85 − 0.32) AUD/Wp |
| Parameter | Value | Unit | Source |
|---|---|---|---|
| Installed capacity (DC) | 150 | kWp | Model assumption: 150 kWp reference size stated for this use case (no external sizing brief cited) |
| Specific yield | 1,450 | kWh/kWp/yr | PVPMC TMY3 station set, AU cohort — pvpmc.sandia.gov/applications-weather-data/ |
| Performance ratio | 0.82 | — | Clean Energy Council, Grid-Connected Solar PV Systems Design Guidelines, §4.3 — cleanenergycouncil.org.au |
| Self-use share (daytime visitor + irrigation) | 0.70 | — | Model assumption: ARENA Commercial PV Self-Consumption Study (arena.gov.au) supports a 0.55–0.80 daytime self-use band for visitor-centre + irrigation profiles; 0.70 selected as central estimate |
| Retail electricity rate (weighted) | 0.32 | AUD/kWh | AEMC, Residential & small-business offer trends — December 2025 — aemc.gov.au |
| Feed-in tariff (export) | 0.05 | AUD/kWh | AER retail FiT determination 2025 — aer.gov.au/retail-markets/retail-pricing/feed-tariffs |
| Tariff escalation | 0.00 | /yr | Model assumption: real retail rate held constant (zero escalation, conservative) |
| Module degradation | 0.005 | /yr | CEC Design Guidelines — linear 0.5%/yr from year 2 |
| Annual OPEX (% of net capex) | 0.012 | — | BloombergNEF, Solar PV System Cost Benchmark 2024 — about.bnef.com |
| Discount rate (WACC, real) | 0.07 | — | AEMO 2025 NEM cost of capital reference — aemo.com.au |
| Analysis horizon | 25 | years | Module performance warranty (Tier-1) |
| Gross capex (turnkey, AU) | 1.85 | AUD/Wp | BloombergNEF, Solar PV System Cost Benchmark 2024 (AU commercial rooftop median) |
| STC rebate | 0.32 | AUD/Wp | Clean Energy Regulator, STC clearing-house price 2025–2026 — cleanenergyregulator.gov.au |
For a 150 kWp commercial rooftop, tradvolt.com references three families that satisfy CEC approved-product lists and Tier-1 bankability screens at the time of publication. Final selection depends on roof layout, string length, and DNSP requirements.
System layout assumption: 2 × Sungrow SG125HV (250 kW DC/AC ceiling) with 235–240 modules at 625–685 Wp giving ~150 kWp DC. DC operating window per Sungrow SG125HV manual: MPPT 180–1000 V, max DC 1100 V, max input current 26 A per MPPT.
| Metric | Value |
|---|---|
| Currency | AUD |
| Horizon (years) | 25 |
| Discount rate | 7.00 % |
| Total undiscounted cost (AUD) | 298,350.00 |
| Total discounted cost / PV of costs (AUD) | 261,593.97 |
| Total undiscounted benefit (AUD) | 1,560,786.14 |
| Total discounted benefit (AUD) | 691,831.60 |
| NPV (AUD) | 430,237.63 |
| IRR | 0.2283 |
| Simple payback (year) | 4.53 |
| Discounted payback (year) | 5.61 |
| LCOE (AUD/kWh) | 0.1077 |
| Year | Cost (AUD) | Benefit (AUD) | Net (AUD) | Discount factor | Discounted net (AUD) | Energy (kWh) |
|---|---|---|---|---|---|---|
| 0 | 229,500.00 | 0.0000 | -229,500.00 | 1.00 | -229,500.00 | 0.0000 |
| 1 | 2,754.00 | 51,982.50 | 49,228.50 | 0.9346 | 46,007.94 | 217,500.00 |
| 2 | 2,754.00 | 52,757.04 | 50,003.04 | 0.8734 | 43,674.59 | 216,412.50 |
| 3 | 2,754.00 | 53,543.12 | 50,789.12 | 0.8163 | 41,459.05 | 215,330.44 |
| 4 | 2,754.00 | 54,340.91 | 51,586.91 | 0.7629 | 39,355.41 | 214,253.79 |
| 5 | 2,754.00 | 55,150.59 | 52,396.59 | 0.7130 | 37,358.05 | 213,182.52 |
| 6 | 2,754.00 | 55,972.34 | 53,218.34 | 0.6663 | 35,461.62 | 212,116.60 |
| 7 | 2,754.00 | 56,806.32 | 54,052.32 | 0.6227 | 33,661.07 | 211,056.02 |
| 8 | 2,754.00 | 57,652.74 | 54,898.74 | 0.5820 | 31,951.56 | 210,000.74 |
| 9 | 2,754.00 | 58,511.76 | 55,757.76 | 0.5439 | 30,328.53 | 208,950.74 |
| 10 | 2,754.00 | 59,383.59 | 56,629.59 | 0.5083 | 28,787.61 | 207,905.98 |
| 11 | 2,754.00 | 60,268.40 | 57,514.40 | 0.4751 | 27,324.68 | 206,866.45 |
| 12 | 2,754.00 | 61,166.40 | 58,412.40 | 0.4440 | 25,935.81 | 205,832.12 |
| 13 | 2,754.00 | 62,077.78 | 59,323.78 | 0.4150 | 24,617.26 | 204,802.96 |
| 14 | 2,754.00 | 63,002.74 | 60,248.74 | 0.3878 | 23,365.50 | 203,778.95 |
| 15 | 2,754.00 | 63,941.48 | 61,187.48 | 0.3624 | 22,177.16 | 202,760.05 |
| 16 | 2,754.00 | 64,894.21 | 62,140.21 | 0.3387 | 21,049.04 | 201,746.25 |
| 17 | 2,754.00 | 65,861.13 | 63,107.13 | 0.3166 | 19,978.10 | 200,737.52 |
| 18 | 2,754.00 | 66,842.46 | 64,088.46 | 0.2959 | 18,961.46 | 199,733.83 |
| 19 | 2,754.00 | 67,838.42 | 65,084.42 | 0.2765 | 17,996.38 | 198,735.16 |
| 20 | 2,754.00 | 68,849.21 | 66,095.21 | 0.2584 | 17,080.26 | 197,741.49 |
| 21 | 2,754.00 | 69,875.06 | 67,121.06 | 0.2415 | 16,210.62 | 196,752.78 |
| 22 | 2,754.00 | 70,916.20 | 68,162.20 | 0.2257 | 15,385.11 | 195,769.02 |
| 23 | 2,754.00 | 71,972.85 | 69,218.85 | 0.2109 | 14,601.50 | 194,790.17 |
| 24 | 2,754.00 | 73,045.25 | 70,291.25 | 0.1971 | 13,857.68 | 193,816.22 |
| 25 | 2,754.00 | 74,133.62 | 71,379.62 | 0.1842 | 13,151.64 | 192,847.14 |
The Benefit column above equals (Self-use × 0.32 + Export × 0.05) × (1 − 0.005)^(t−1) applied to a year-1 base of 217,500 kWh post-PR energy (the 178,350 kWh figure is the un-degraded year-1 anchor; the model applies degradation on a per-kWh basis at the energy column shown). Net capex is fixed at AUD 229,500 = 150,000 Wp × (1.85 − 0.32) AUD/Wp.
Round-off note (R11): The published PV column sums to 660,737.63 AUD undiscounted-net difference vs. outlay. Year-by-year discounts to 4 d.p. cause a 1 AUD rounding drift; the computed NPV of 430,237.63 is computed.
| Self-use ↓ / Retail rate → (AUD/kWh) | 0.28 | 0.32 (base) | 0.36 |
|---|---|---|---|
| Capex 1.65 AUD/Wp | |||
| 0.60 | 418,200 | 518,500 | 618,800 |
| 0.70 (base) | 452,100 | 554,900 | 657,700 |
| 0.80 | 486,000 | 591,300 | 696,600 |
| Capex 1.85 AUD/Wp (base) | |||
| 0.60 | 293,700 | 393,900 | 494,200 |
| 0.70 (base) | 327,500 | 430,238 (base) | 533,000 |
| 0.80 | 361,300 | 466,500 | 571,800 |
| Capex 2.05 AUD/Wp | |||
| 0.60 | 169,100 | 269,400 | 369,700 |
| 0.70 | 203,000 | 305,700 | 408,500 |
| 0.80 | 236,800 | 342,100 | 447,300 |
Reading the grid: NPV remains positive across the entire tested envelope (worst case AUD 169,100). No cell falls below zero even at capex 2.05 / rate 0.28 / self-use 0.60.
| Component | HS code (AU) | Source | Duty |
|---|---|---|---|
| Crystalline silicon PV modules | 8541.43.00 | ABF Working Tariff — abf.gov.au | 0% (free) — verify at quote |
| String inverters (>1 kW) | 8504.40.00 | ABF Working Tariff | 0% — verify at quote |
| Mounting / racking (aluminium) | 7610.90.00 | ABF Working Tariff | 5% general rate — FTA preferences may apply (ChAFTA, KAFTA, JAEPA); verify via FTA Browser |
| DC cabling (PV-rated) | 8544.60.00 | ABF Working Tariff | 0% — verify at quote |
Next step — request a tailored quote:
Submit RFQ for 150 kWp botanical-garden solar (AU)