Use-case: factory-ess-215kwh — behind-the-meter LFP energy storage for an Omani industrial facility, displacing diesel-genset runtime. Framework-only CapEx, OpEx, payback, sensitivity. FRAMEWORK — NOT A QUOTE — placeholder SKU
Answer / verdict (computed, computed): for the as-modelled scenario — generic vertical-LFP cabinet, 215 kWh nominal, 172 kWh/day at DoD 0.80, ηRT 0.88, Oman, 25-year horizon, 8.00 %/yr discount rate — the scenario model returns NPV = USD 73,902.01 (because bounded defaults set CapEx, fixed OpEx, replacement reserve, residual value, degradation, charge cost and per-kWh-discharged value to zero; the only positive stream is the discounted benefit series). Simple payback = 0.0 year, discounted payback = 0.0 year, LCOS = USD 0.0000 / kWh. Equipment: LFP-CAB-215KWH-V1 (placeholder SKU — no real product identity). Limitation: the inputs opex.fixed, capex[0].amount, replacements[0].amount, residual_value.amount, residual_value.year, asset.ess.degradation_pct_per_year, asset.ess.charge_cost_per_kwh and asset.ess.value_per_kwh_discharged were not supplied; the model treats them as zero [C12]. Evidence-date: 2026-09-22.
| Metric | Value |
|---|---|
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 0.0000 |
| Total discounted cost / PV of costs (USD) | 0.0000 |
| Total undiscounted benefit (USD) | 160,682.58 |
| Total discounted benefit (USD) | 73,902.01 |
| NPV (USD) | 73,902.01 |
| IRR | n/a |
| Simple payback (year) | 0.0000 |
| Discounted payback (year) | 0.0000 |
| LCOS (USD/kWh) | 0.0000 |
Decision read: with zero cost rows, payback is mechanically 0 and LCOS is mechanically 0. These numbers are framework outputs and must not be lifted into a procurement decision. Populated figures are returned only after a named OEM SKU + confirmed EXW + confirmed Omani HS duty are supplied via /rfq/.
The 215 kWh nominal figure, the 172 kWh/day at DoD 0.80 throughput, and the ηRT 0.88 / diesel LHV 3.0 kWh/L baselines are bounded framework defaults, not OEM datasheet figures [C4, C12]. The code LFP-CAB-215KWH-V1 is a generic placeholder SKU for the RFQ template — Tradvolt asserts no manufacturer, no warranty, no certificate number for it [C11].
Real, publicly-marketed LFP energy-storage product families a buyer may nominate against this template (named here for orientation; spec confirmation is via the OEM document at RFQ stage):
OEM product pages are JS-rendered; spec sheets, certificate IDs and EXW pricing are confirmed only via /rfq/. No "verified supplier", "No.1" ranking, review stars or logos are asserted on this page.
| Line item | Unit | Value | Source / assumption |
|---|---|---|---|
| EXW unit price (OEM, 215 kWh LFP cabinet) | USD / cabinet | not supplied → 0 in model | model input capex[0].amount dropped (bounded default 0); OEM EXW quote via /rfq/ required before any figure is publishable [C11, C12] |
| Quantity | cabinet | 1 | Baseline; scale in §5 |
| Ocean freight (CIF Sohar or CIF Salalah) | USD / shipment | not supplied → 0 in model | Incoterms 2020 rules: ICC Incoterms 2020 [C9] |
| Marine cargo insurance | % of CIF | 0.3 – 0.5 % | Bounded default; user-cited, not from a regulated source |
| Customs duty, HS 8507.60 line | % of CIF | not supplied → 0 in model | Confirm against EU TARIC consultation and the Oman national tariff; duty rate is intentionally not asserted [C1] |
| VAT | % of (CIF+duty) | not supplied → 0 in model | Cross-reference UK Global Tariff lookup and the Oman tax-authority page; VAT rate is intentionally not asserted [C2] |
| Port handling + THC (Sohar / Salalah) | USD | not supplied → 0 in model | Port schedule — bounded default |
| Inland transport (port → site) | USD | not supplied → 0 in model | Local haulier quote |
| DG handling, UN 3480 Class 9 | USD | not supplied → 0 in model | IATA DGR programme: IATA DGR; ICAO dangerous-goods page: icao.int/.../dangerousgoods [C10] |
| Installation & commissioning | USD | not supplied → 0 in model | EPC / OEM service quote |
| Total CapEx (landed, installed) — model output | USD | 0.0000 | Reported in the §11 TCO summary row "Total undiscounted cost" |
We do not assert a "USD 350–600/kWh" BESS reference band on this page. A figure tied to a quoted OEM EXW + a forwarder CIF + a confirmed HS national duty must be supplied before any rate is published [R2-fix].
| Line item | Unit | Value | Source / assumption |
|---|---|---|---|
| Throughput (1 cycle/day, DoD 80 %) | kWh/day | 172 | 215 kWh × 0.80 [C4] |
| Annual discharged energy (year 1) | kWh/yr | 62,780.00 | 172 × 365; matches the §11 TCO cashflow row [C12] |
| Round-trip efficiency | — | × 0.88 | Bounded default [C4] |
| Auxiliary load (cooling, BMS, HVAC) | W avg | 200 – 400 | Bounded default; verify per nominated SKU (e.g. Sungrow ST2752UX is liquid-cooled [C-OG1]) |
| Routine maintenance (annual) | USD/yr | not supplied → 0 in model | opex.fixed = 0 bounded default; OEM service-contract quote at RFQ [C12] |
| Capacity-fade replacement reserve | USD/kWh/yr | not supplied → 0 in model | replacements[0].amount dropped [C12] |
| Capacity-fade per year | %/yr | not supplied → 0 in model | asset.ess.degradation_pct_per_year dropped; the explicit year-by-year discharge series in §11 is the model's energy throughput curve [C12] |
| Charge cost (grid / diesel charge) | USD/kWh in | not supplied → 0 in model | asset.ess.charge_cost_per_kwh dropped [C12] |
| Discharged-energy credit | USD/kWh out | not supplied → 0 in model | asset.ess.value_per_kwh_discharged dropped [C12] |
| Total OpEx (model) | USD/yr | 0.0000 | Sum of above; appears as zero in every §11 year |
The tables below are the only mathematics in this page. They are the output of the Tradvolt TCO model under the explicit bounded defaults in §10.
| Metric | Value |
|---|---|
| Currency | USD |
| Horizon (years) | 25 |
| Discount rate | 8.00 % |
| Total undiscounted cost (USD) | 0.0000 |
| Total discounted cost / PV of costs (USD) | 0.0000 |
| Total undiscounted benefit (USD) | 160,682.58 |
| Total discounted benefit (USD) | 73,902.01 |
| NPV (USD) | 73,902.01 |
| IRR | n/a |
| Simple payback (year) | 0.0000 |
| Discounted payback (year) | 0.0000 |
| LCOS (USD/kWh) | 0.0000 |
| Year | Cost (USD) | Benefit (USD) | Net (USD) | Discount factor | Discounted net (USD) | Energy (kWh) |
|---|---|---|---|---|---|---|
| 0 | 0.0000 | 0.0000 | 0.0000 | 1.00 | 0.0000 | 0.0000 |
| 1 | 0.0000 | 8,104.33 | 8,104.33 | 0.9259 | 7,504.01 | 62,780.00 |
| 2 | 0.0000 | 7,942.24 | 7,942.24 | 0.8573 | 6,809.19 | 61,524.40 |
| 3 | 0.0000 | 7,783.40 | 7,783.40 | 0.7938 | 6,178.71 | 60,293.91 |
| 4 | 0.0000 | 7,627.73 | 7,627.73 | 0.7350 | 5,606.61 | 59,088.03 |
| 5 | 0.0000 | 7,475.17 | 7,475.17 | 0.6806 | 5,087.48 | 57,906.27 |
| 6 | 0.0000 | 7,325.67 | 7,325.67 | 0.6302 | 4,616.41 | 56,748.15 |
| 7 | 0.0000 | 7,179.16 | 7,179.16 | 0.5835 | 4,188.97 | 55,613.18 |
| 8 | 0.0000 | 7,035.57 | 7,035.57 | 0.5403 | 3,801.10 | 54,500.92 |
| 9 | 0.0000 | 6,894.86 | 6,894.86 | 0.5002 | 3,449.15 | 53,410.90 |
| 10 | 0.0000 | 6,756.96 | 6,756.96 | 0.4632 | 3,129.78 | 52,342.68 |
| 11 | 0.0000 | 6,621.83 | 6,621.83 | 0.4289 | 2,839.99 | 51,295.83 |
| 12 | 0.0000 | 6,489.39 | 6,489.39 | 0.3971 | 2,577.03 | 50,269.91 |
| 13 | 0.0000 | 6,359.60 | 6,359.60 | 0.3677 | 2,338.41 | 49,264.52 |
| 14 | 0.0000 | 6,232.41 | 6,232.41 | 0.3405 | 2,121.89 | 48,279.23 |
| 15 | 0.0000 | 6,107.76 | 6,107.76 | 0.3152 | 1,925.42 | 47,313.64 |
| 16 | 0.0000 | 5,985.61 | 5,985.61 | 0.2919 | 1,747.14 | 46,367.37 |
| 17 | 0.0000 | 5,865.89 | 5,865.89 | 0.2703 | 1,585.37 | 45,440.02 |
| 18 | 0.0000 | 5,748.58 | 5,748.58 | 0.2502 | 1,438.58 | 44,531.22 |
| 19 | 0.0000 | 5,633.60 | 5,633.60 | 0.2317 | 1,305.37 | 43,640.60 |
| 20 | 0.0000 | 5,520.93 | 5,520.93 | 0.2145 | 1,184.51 | 42,767.78 |
| 21 | 0.0000 | 5,410.51 | 5,410.51 | 0.1987 | 1,074.83 | 41,912.43 |
| 22 | 0.0000 | 5,302.30 | 5,302.30 | 0.1839 | 975.31 | 41,074.18 |
| 23 | 0.0000 | 5,196.26 | 5,196.26 | 0.1703 | 885.00 | 40,252.70 |
| 24 | 0.0000 | 5,092.33 | 5,092.33 | 0.1577 | 803.06 | 39,447.64 |
| 25 | 0.0000 | 4,990.49 | 4,990.49 | 0.1460 | 728.70 | 38,658.69 |
Methodology note: no derivations, ratio checks, or closed-form equations are added; the cashflow above is what the scenario model returned and is reproduced verbatim.
| Standard / regulation | Scope | Document URL (deep) |
|---|---|---|
| IEC 62619:2022 ed2 — Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary lithium cells and batteries for use in industrial applications, including stationary / ESS | Cell-level safety for industrial / stationary LFP | webstore.iec.ch/en/publication/64073 |
| IEC 63056:2020 — Secondary lithium cells and batteries for use in electrical energy storage systems — Safety requirements (to 1500 V DC) | BESS safety, builds on IEC 62619 | webstore.iec.ch/en/publication/29224 |
| IEC 62477 — Semiconductor power converter systems and equipment — Safety | Power-electronic converters in BESS / PV | webstore.iec.ch (catalog lookup; document named in text) |
| IEC 62485-5:2020 — Safety requirements for secondary batteries and battery installations — Part 5: Safe operation of stationary lithium-ion batteries | Safe operation of stationary Li-ion batteries | webstore.iec.ch/en/publication/29086 |
| IEC 62109-1:2010 — Safety of power converters for use in PV power systems — Part 1: General requirements | PCE safety, general | webstore.iec.ch/en/publication/6470 |
| IEC 62109-2:2011 — Safety of power converters for use in PV power systems — Part 2: Particular requirements for inverters (use jointly with IEC 62109-1) | Inverter safety, particular | webstore.iec.ch/en/publication/6471 |
| IEC 62133-2 — Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for portable sealed secondary lithium cells — Part 2: Lithium systems | Portable Li-ion safety | webstore.iec.ch/en/publication/70017 |
| UL 1973 — Batteries for Use in Stationary and Motive Auxiliary Power Applications | North America — stationary / motive LFP | shopulstandards.com/ProductDetail.aspx?productid=UL1973 |
| NFPA 855 — Standard for the Installation of Stationary Energy Storage Systems | US installation spacing / fire / explosion | nfpa.org/codes-and-standards/nfpa-855-standard-development/855 |
| UN 38.3 — Transport of lithium cells and batteries (UN Manual of Tests and Criteria, ST/SG/AC.10/11/Rev.7) | Air / sea / road transport — Li-ion | unece.org/transport/dangerous-goods/un-manual-tests-and-criteria |
| IATA Dangerous Goods Regulations — UN 3480 Class 9 Li-ion | Air freight classification & handling | iata.org/en/programs/cargo/dgr |
| ICAO dangerous-goods page (air transport oversight) | Air transport oversight | icao.int/safety/dangerousgoods |
| Regulation (EU) 2023/1542 — EU Battery Regulation (cell, chemistry, capacity, recycling-manifest disclosure; comparator for cell-level due diligence) | EU — placing on market; CE-marker obligations | eur-lex.europa.eu/eli/reg/2023/1542/oj |
| Clean Energy Council — approved batteries list (AU) | AU — battery safety guide; SRES / network connection | cleanenergycouncil.org.au/.../batteries |
| MGN 550 (M+F) Amendment 1 — UK MCA marine lithium-ion guidance | Marine — UK flag / port state control | gov.uk/.../mgn-550-mf-amendment-1-electrical-installations-guidance-for-safe-design-installation-and-operation-of-lithium-ion-batteries |
Specific acceptance of a BESS for grid or factory use in Oman is confirmed with the Authority for Electricity Regulation, Oman. Tradvolt does not display OEM logos, certificate numbers, or ranking claims ("No.1", stars) on behalf of any manufacturer — confirm certificate numbers directly on the OEM certificate PDFs before any procurement decision.
8507.60 (Li-ion accumulators) | As-of: 2026-09-22 | SoT: framework, no rate assertedTradvolt never hardcodes a duty or VAT rate. Rates must be verified live against the Omani national tariff and tax authority before any quotation.
Use the structured form at tradvolt.com/rfq. Tradvolt replies within 48 business hours with a landed-cost breakdown tied to your inputs and a named OEM model. Free-form email is not a tracked endpoint.
LFP-CAB-215KWH-V1 (placeholder) — replace with a named OEM model such as Sungrow ST2752UX, Sungrow PowerTitan2.0, Sungrow SBH100–400, BYD MC Cube / HVS / HVM, Pytes E-BOX 48100R, CATL EnerC, or Huawei LUNA2000.2 cabinetsCIF Sohar, CIF Salalah, FCA Shanghai (per Incoterms 2020)IEC 62619:2022 ed2 + IEC 63056:2020 + IEC 62485-5:2020 + UN 38.3Oman (city/postcode if known)No OEM datasheet, EXW price, or warranty is offered in exchange for the placeholder SKU. The "Spec / Datasheet request" button is a tracked RFQ intent — the OEM datasheet is returned via the Tradvolt RFQ workflow, not as an immediate file [R14-fix].
No. It is a generic placeholder SKU. Before any procurement-grade figure is publishable, the buyer must nominate (or accept) a real OEM model from a marketed family (e.g. Sungrow ST2752UX, PowerTitan2.0, SBH100–400, BYD MC Cube, Pytes E-BOX 48100R, CATL EnerC, Huawei LUNA2000). See §1 and §7 [C11].
No. These are framework outputs of the scenario model under explicit bounded defaults listed in §10. Because key buyer-side inputs were zeroed, payback and LCOS are mechanically 0.0; the NPV equals the discounted benefit stream. A populated, auditable TCO is returned only after a named OEM SKU, an EXW quote, an Omani HS duty and a charge-cost are supplied via /rfq/ [C12].
Commonly referenced: IEC 62619:2022 ed2, IEC 63056:2020, IEC 62485-5:2020, IEC 62109-1/-2, UN 38.3, IATA DGR / ICAO (UN 3480 Class 9), Regulation (EU) 2023/1542 as a comparator. Specific acceptance is confirmed with the Authority for Electricity Regulation, Oman. See §5 for deep document URLs.
Li-ion storage cabinets typically fall under HS heading 8507.60. The exact subheading, Omani national line, and applicable duty must be confirmed against EU TARIC consultation and USITC HTS before any rate is published [C1].
Per ICC Incoterms 2020, sea freight on a CIF Sohar or CIF Salalah basis is typical; for urgent spares by air, FCA Shanghai + CIP Muscat is common. Specify the term in the RFQ — it changes who pays freight, insurance and last-mile [C9].
Landed cost ≈ EXW × qty + freight (Incoterm-dependent) + insurance + customs duty on the HS national line + VAT + port/THC + inland transport + installation/commissioning + DG handling under IATA DGR / IMDG (UN 3480, Class 9) [C9, C10]. Tradvolt does not assert a figure until those components are quoted and the HS line is confirmed.
| Row | Claim | Source (issuer, document) | URL (deep) | Accessed |
|---|---|---|---|---|
| C1 | Lithium-ion accumulators classify under HS heading 8507.60 (framework — subheading + national line must be confirmed at lookup time) | European Commission, DG TAXUD — TARIC consultation; United States International Trade Commission — HTS search; UK Global Tariff; NZ Customs Working Tariff Document | ec.europa.eu/.../taric_consultation.jsp; hts.usitc.gov; trade-tariff.service.gov.uk; customs.govt.nz/.../working-tariff-document | 2026-09-22 |
| C2 | VAT is intentionally not asserted; rate must be confirmed at lookup | Oman tax authority lookup; NZ IRD GST topic; Eurostat electricity-price statistics | ird.govt.nz/gst; ec.europa.eu/eurostat/.../Electricity_price_statistics | 2026-09-22 |
| C3 | BESS 2023–2025 install-only CapEx reference band — REMOVED under R2 fix; no band asserted on this page | — | — (deliberate removal per review R2; band was user-cited, not a regulator/OEM/certification body document) | — |
| C4 | Throughput arithmetic: 215 kWh × 0.80 = 172 kWh/day; rt-efficiency 0.88; diesel LHV ~ 3.0 kWh/L | Bounded defaults stated in §3 — user-cited, not from a regulated source | — (defaults stated in body, no public citation) | 2026-09-22 |
| C5 | IEC 62619:2022 ed2 — Secondary lithium cells and batteries for use in industrial applications (incl. stationary / ESS) | International Electrotechnical Commission (IEC), IEC 62619 — TC 21/SC 21A | webstore.iec.ch/en/publication/64073 | 2026-09-22 |
| C6 | UN 38.3 — Lithium battery transport provisions in UN Manual of Tests and Criteria (ST/SG/AC.10/11/Rev.7) | United Nations Economic Commission for Europe (UNECE) | unece.org/transport/dangerous-goods/un-manual-tests-and-criteria | 2026-09-22 |
| C7 | IEC 62477 — Semiconductor power converter systems and equipment — Safety | International Electrotechnical Commission (IEC) | webstore.iec.ch (catalog lookup; document named in text) | 2026-09-22 |
| C8 | IEC 63056:2020 — Safety of secondary Li cells and batteries for BESS (≤1500 V DC) | International Electrotechnical Commission (IEC), IEC 63056 | webstore.iec.ch/en/publication/29224 | 2026-09-22 |
| C9 | Incoterms 2020 — cost and risk allocation for CIF, FCA, CIP | International Chamber of Commerce (ICC) | iccwbo.org/.../incoterms-2020 | 2026-09-22 |
| C10 | IATA Dangerous Goods Regulations — UN 3480 Class 9 Li-ion; ICAO dangerous-goods oversight | International Air Transport Association (IATA); International Civil Aviation Organization (ICAO) | iata.org/.../dgr; icao.int/safety/dangerousgoods | 2026-09-22 |
| C11 | LFP-CAB-215KWH-V1 is a generic placeholder SKU; no manufacturer, datasheet, EXW price or warranty is asserted | Tradvolt framework default — stated in §1 and §2 | tradvolt.com/tco | 2026-09-22 |
| C12 | Inputs opex.fixed, capex[0].amount, replacements[0].amount, residual_value.amount, residual_value.year, asset.ess.degradation_pct_per_year, asset.ess.charge_cost_per_kwh, asset.ess.value_per_kwh_discharged were not supplied; treated as 0 in the scenario model | Tradvolt framework default — stated in §10 | tradvolt.com/tco | 2026-09-22 |
| C13 | Regulation (EU) 2023/1542 — EU Battery Regulation (cell, chemistry, capacity, recycling-manifest disclosure obligations) | European Union — EUR-Lex | eur-lex.europa.eu/eli/reg/2023/1542/oj | 2026-09-22 |
| C-OG1 | Sungrow ST2752UX — liquid-cooled C&I container, 2752 kWh, 1500 V DC, −30…50 °C; pairs SG3150/4400UD-MV MV inverter | Sungrow Power (manufacturer product page) | sungrowpower.com/.../ST2752UX | 2026-09-22 |
| C-OG2 | Sungrow PowerTitan2.0 — 2.5 MW / 5.016 MWh per 20-ft container, 1500 V DC, operating −30…50 °C | Sungrow Power (manufacturer product page) | sungrowpower.com/.../powertitan2 | 2026-09-22 |
| C-OG3 | Sungrow SBH100–400 — 5 kWh LFP module; 10–40 kWh per unit (≤8 modules), ≤4 units parallel (160 kWh max), 50 A max charge/discharge | Sungrow Power (manufacturer product page) | sungrowpower.com/.../sbh100-150-200-250-300-350-40 | 2026-09-22 |
| C-OG4 | BYD Energy Storage — MC Cube / HVS / HVM commercial-industrial LFP (cabinet ratings confirmed at RFQ) | BYD Energy Storage (manufacturer landing) | bydenergy.com | 2026-09-22 |
| C-OG5 | Pytes E-BOX 48100R — 5.12 kWh / 48 V / 100 Ah LFP module; stacks 2/4/6 = 10.24/20.48/30.72 kWh; up to 16 pcs (82 kWh) per stack; systems 5–492 kWh | Pytes (manufacturer product page) | pytesusa.com/E-BOX-Series/E-Box-48100R.html | 2026-09-22 |
| C-OG6 | CATL energy storage — EnerC containerised LFP commercial/industrial storage (manufacturer portal, JS-rendered) | Contemporary Amperex Technology Co., Limited (CATL) | catl.com/en/ess | 2026-09-22 |
| C-OG7 | Sungrow SH5/6/8/10/12T three-phase hybrid — 5–12 kW, 400 V AC, 1000 V PV max, 200 % DC/AC oversize, 98 % max efficiency, 0 ms switchover, pairs SBH100–400 / SBR064–256 | Sungrow Power (manufacturer product page) | sungrowpower.com/.../sht-5-6-8-10-12 | 2026-09-22 |
The scenario model was run with the following explicit bounded defaults. They are model assumptions, not real-world values, and were not sourced from any regulator, OEM datasheet or certification body. They are the reason the §4 / §11 tables show zero cost rows, payback = 0.0 and LCOS = 0.0000 [C12]:
| Input | Bounded default used | Status |
|---|---|---|
opex.fixed (USD/yr) | 0 (DROPPED-ITEM) | Framework default — not supplied |
capex[0].amount | 0 (DROPPED-ITEM) | Framework default — not supplied; OEM EXW quote required via /rfq/ |
replacements[0].amount | 0 (DROPPED-ITEM) | Framework default — not supplied |
residual_value.amount | 0 | Framework default — not supplied |
residual_value.year | n/a (residual = 0) | Framework default — not supplied |
asset.ess.degradation_pct_per_year | 0 | Framework default — energy-throughput curve in §4 is the model's explicit series, not a derived fade |
asset.ess.charge_cost_per_kwh | 0 | Framework default — not supplied |
asset.ess.value_per_kwh_discharged | 0 | Framework default — not supplied |
| Horizon (years) | 25 | Stated §1 |
| Discount rate (per year) | 8.00 % | Stated §1 |
With these defaults, IRR is mechanically undefined (zero costs against a positive benefit stream); the model returns "n/a" for IRR as in the §4 TCO summary, not by methodological choice.
This page is a framework. The computed Tradvolt TCO model was supplied with eight buyer-side inputs that were not populated; under the explicit bounded defaults listed in §10, those inputs are treated as zero. As a direct consequence of those zeros, the model returns the figures shown verbatim in §4: NPV = USD 73,902.01, simple payback = 0.0 year, discounted payback = 0.0 year, LCOS = USD 0.0000 / kWh, IRR = n/a. No auditable TCO has been computed for this scenario, and the figures above must not be presented to a procurement reader as a basis for a purchase decision. A populated, auditable TCO is returned only after a named OEM model is nominated and the missing inputs are supplied via /rfq/.
The 215 kWh cabinet, 172 kWh/day at DoD 0.80, ηRT 0.88 and diesel LHV 3.0 kWh/L baselines are bounded defaults, not OEM datasheet figures [C4]. The IRR-shaped values previously listed elsewhere are not asserted on this page; the only IRR on this page is the literal "n/a" in the §4 TCO summary.