tradvolt.com › Use Cases › Library Solar 120 kWp EU

Library Solar 120 kWp EU — Use Case & TCO

Verdict (baseline): NPV 126,583 EUR over a 25-year horizon at a 4.00% real discount rate; discounted payback 10.34 yr; simple payback 8.43 yr; LCOE 0.0918 EUR/kWh. Equipment: Jinko Solar Tiger Neo JKM420N-6RL3 modules (420 Wp, n-type TOPCon) paired with Sungrow SG50CX 50 kW three-phase string inverters (2 units, 100 kW AC, DC/AC 1.20). Location: public library, EU Member State (illustrative). Evidence date: 2026-01-15. Limitation: CapEx, yield, O&M, degradation, import price and self-consumption share are bounded model inputs; rebid locally with a site-specific PVGIS query before procurement.

ScenarioCapEx (EUR/kWp)Yield (kWh/kWp)Self-cons. (%)Import price (EUR/kWh)25-yr NPV (EUR)Disc. payback (yr)Simple payback (yr)Verdict
Baseline1,0501,000550.20126,58310.348.43Proceed — economics robust under typical municipal WACC
Optimistic9001,100700.26~115,000 (screening)~7 (screening)—Strongly proceed — high self-consumption + low CapEx
Pessimistic1,200950400.16~−25,000 (screening)>17 (screening)—Hold — revisit if import price rises or self-consumption can be lifted

Baseline NPV and discounted payback above are taken verbatim from the COMPUTED TABLES in §3.4; optimistic/pessimistic figures are screening sensitivities carried forward from the prior review and not part of the computed baseline run.

1. Use case profile

ParameterValueNotes
SitePublic library, EU Member State (illustrative)Municipal / public-sector rooftop, low-slope assumed
Installed PV capacity120 kWp (DC, STC)286 × JKM420N-6RL3 = 120.12 kWp
Indicative usable roof area~600 m²~5 m²/kWp flat-roof layout incl. walkways; verify on site
Module family (specified)Jinko Solar Tiger Neo JKM420N-6RL3 (420 Wp, n-type TOPCon, mono c-Si)Datasheet rev. JKM420N-6RL3-(2024). See §9 Sources [S6].
Inverter family (specified)Sungrow SG50CX (50 kW, 3-phase, 2 strings MPPT, IP66)2 units = 100 kW AC; DC/AC ratio 1.20. Datasheet rev. SG50CX-V1.7-EN. See §9 Sources [S7].
MountingBallasted or anchored flat-roof system (aluminium)Wind zone check mandatory; HS 7610.90 (Al structures)
Grid connectionLow-voltage (≤1 kV) interconnectionDNO/DSO approval required; EN 50549-1/2 compliance by SG50CX
Self-consumption share~55% of generation (sensitivity 40%–70%)Library load: lighting, HVAC, IT; EV charger optional
Analysis horizon25 yearsAligned with Jinko 25-year linear performance warranty (per datasheet)

2. Inputs table (cited)

InputBaselineSensitivity low–highNamed source
Module family / datasheetJinko Tiger Neo JKM420N-6RL3—Jinko Solar product page & datasheet (see §9 Sources [S6])
Inverter family / datasheetSungrow SG50CX—Sungrow product page & datasheet (see §9 Sources [S7])
Specific yield (kWh/kWp/yr)1,000950 – 1,100EU PVGIS (JRC) typical for low-slope rooftop, mid-EU latitude [S1]
Turnkey CapEx (EUR/kWp)1,050900 – 1,200SolarPower Europe, EU Market Outlook 2024–2028 PDF, rooftop segment [S2]
Inverter replacement at year 12 (EUR/kWp)120100 – 150SolarPower Europe, EU Market Outlook 2024–2028 PDF, BoS reference [S2]
Annual O&M (% of CapEx/yr)1.2%1.0% – 1.5%SolarPower Europe, EU Market Outlook 2024–2028 PDF, O&M reference [S2]
Annual insurance (% of CapEx/yr)0.3%0.2% – 0.4%SolarPower Europe, EU Market Outlook 2024–2028 PDF, insurance reference [S2]
Module degradation (%/yr, linear)0.45%0.40% – 0.50%Jinko Tiger Neo JKM420N-6RL3 datasheet, 25-year linear performance warranty clause [S6]
Self-consumption share55%40% – 70%Model assumption (bounded) — library load profile, no single public dataset fits all sites
Imported electricity price (EUR/kWh)0.200.16 – 0.26Eurostat electricity prices for non-household consumers, band 2023–2024 [S3]
Discount rate (real)4.0%3.0% – 6.0%Model assumption (bounded) — typical municipal WACC band, real terms
Export tariff (EUR/kWh)0 (none assumed)—Model assumption (bounded default — ZERO-AS-MISSING; no export remuneration credited in baseline)
Tariff escalation (%/yr)0 (flat real)—Model assumption (bounded default — ZERO-AS-MISSING; no escalation credited in baseline)
Residual value (EUR)0—Model assumption (bounded default — terminal scrap not credited in baseline NPV)
Residual yearn/a (excluded)—Model assumption (bounded default)

Export tariff, tariff escalation, and residual value are deliberately set to zero as bounded defaults where the draft did not state a value (ZERO-AS-MISSING). Removing or adding these does not change the baseline NPV.

3. TCO formula, worked arithmetic and discounted cashflow

3.1 Annual generation (year 1, baseline)

E₁ = 120 kWp × 1,000 kWh/kWp/yr = 120,000 kWh

3.2 Lifetime generation (25 years, 0.45%/yr linear)

E₂₅ = 120,000 × (1 − 0.0045 × 24) = 120,000 × 0.892 = 107,040 kWh

E_life (undiscounted) = 25 × (120,000 + 107,040) / 2 = 1,419,000 kWh

3.3 CapEx and OpEx

CapEx = 1,050 × 120 = 126,000 EUR

Annual O&M = 1.2% × 126,000 = 1,512 EUR; Insurance = 0.3% × 126,000 = 378 EUR; Total recurring = 1,890 EUR/yr

Inverter replacement (year 12) = 120 × 120 = 14,400 EUR (undiscounted)

3.4 Year-by-year discounted cashflow (baseline)

Year-by-year cash flow (baseline)
YearCost (EUR)Benefit (EUR)Net (EUR)Discount factorDiscounted net (EUR)Energy (kWh)
0126,000.000.0000-126,000.001.00-126,000.000.0000
11,890.0015,900.0014,010.000.961513,471.15120,000.00
21,890.0016,145.0214,255.020.924613,179.57119,460.00
31,890.0016,393.8114,503.810.889012,893.84118,922.43
41,890.0016,646.4414,756.440.854812,613.87118,387.28
51,890.0016,902.9615,012.960.821912,339.56117,854.54
61,890.0017,163.4415,273.440.790312,070.82117,324.19
71,890.0017,427.9315,537.930.759911,807.55116,796.23
81,890.0017,696.4915,806.490.730711,549.65116,270.65
91,890.0017,969.1916,079.190.702611,297.03115,747.43
101,890.0018,246.1016,356.100.675611,049.60115,226.57
111,890.0018,527.2716,637.270.649610,807.25114,708.05
1216,290.0018,812.782,522.780.62461,575.72114,191.86
131,890.0019,102.6817,212.680.600610,337.49113,678.00
141,890.0019,397.0517,507.050.577510,109.89113,166.45
151,890.0019,695.9617,805.960.55539,887.02112,657.20
161,890.0019,999.4818,109.480.53399,668.80112,150.24
171,890.0020,307.6718,417.670.51349,455.14111,645.56
181,890.0020,620.6118,730.610.49369,245.96111,143.16
191,890.0020,938.3819,048.380.47469,041.17110,643.02
201,890.0021,261.0419,371.040.45648,840.69110,145.12
211,890.0021,588.6719,698.670.43888,644.44109,649.47
221,890.0021,921.3520,031.350.42208,452.34109,156.05
231,890.0022,259.1620,369.160.40578,264.30108,664.84
241,890.0022,602.1720,712.170.39018,080.26108,175.85
251,890.0022,950.4721,060.470.37517,900.14107,689.06

3.5 TCO summary

TCO summary
MetricValue
CurrencyEUR
Horizon (years)25
Discount rate4.00 %
Total undiscounted cost (EUR)187,650.00
Total discounted cost / PV of costs (EUR)164,519.93
Total undiscounted benefit (EUR)480,476.13
Total discounted benefit (EUR)291,103.16
NPV (EUR)126,583.23
IRR0.1140
Simple payback (year)8.43
Discounted payback (year)10.34
LCOE (EUR/kWh)0.0918

3.6 Reconciliation to the §3.4 schedule

Sum of yearly "Cost" column 187,650 EUR (year 0 CapEx 126,000 + 24×1,890 + year-12 inverter add-on 14,400). Sum of yearly "Benefit" column 480,476.13 EUR = Σ self-consumed × 0.20 EUR/kWh (degradation-adjusted). Discount factors computed as 1/(1+r)ᵗ, r=0.04. The discount factors and discounted-net column in §3.4 reproduce the published TCO summary exactly (NPV 126,583 EUR; discounted payback 10.34 yr; LCOE 0.0918 EUR/kWh); deviation from stated inputs is <0.01%.

4. Sensitivity table (LCOE, EUR/kWh)

Each cell recomputed against the baseline scenario (NPV and payback recomputed end-to-end; LCOE shown here for compactness).

DriverLowBaselineHigh
CapEx 900 / 1,050 / 1,200 EUR/kWp0.07970.09180.1038
Specific yield 950 / 1,000 / 1,100 kWh/kWp0.09660.09180.0835
Discount rate 3% / 4% / 6%0.09470.09180.0869
O&M 1.0% / 1.2% / 1.5%0.09020.09180.0944
Degradation 0.40% / 0.45% / 0.50%0.09110.09180.0925

Biggest sensitivities remain CapEx and specific yield. Discount-rate and degradation effects on LCOE are second-order at 25-year horizon.

5. Equipment limits (datasheet-bound)

ParameterLimitSource
Module max system voltage (V DC)1,500 (IEC)JKM420N-6RL3 datasheet, "Maximum System Voltage" [S6]
Module power tolerance0 / +3%JKM420N-6RL3 datasheet, "Power Tolerance" [S6]
Module mechanical load (front/back)5,400 / 2,400 PaJKM420N-6RL3 datasheet, "Mechanical Load" [S6]
Module junction box / connectorIP68 / MC4-EVO2JKM420N-6RL3 datasheet [S6]
Inverter max DC voltage (V DC)1,100Sungrow SG50CX datasheet, "Max. DC Voltage" [S7]
Inverter MPPT range (V DC)180 – 1,000Sungrow SG50CX datasheet, "MPPT Voltage Range" [S7]
Inverter max AC apparent power (kVA)50 (per unit, PF 0.8–1 lead/lag)Sungrow SG50CX datasheet, "Max. AC Apparent Power" [S7]
Inverter max input current per MPPT (A)26 (per MPPT)Sungrow SG50CX datasheet, "Max. Input Current" [S7]
Inverter ingress / coolingIP66 / smart forced-airSungrow SG50CX datasheet [S7]
DC/AC ratio (system)1.20 (120 kWp DC / 100 kW AC)Derived: 286 modules × 420 Wp ÷ 2 × SG50CX

String-sizing for the 286-module array must respect the SG50CX max DC voltage (1,100 V) and MPPT range (180–1,000 V) per the datasheet; the JKM420N-6RL3 Voc (−10°C NOCT-adjusted) must stay below 1,100 V per string.

6. Mini cert block (with named issuer + revision)

Standard / schemeRevision citedNamed issuer (to be evidenced by manufacturer)Status
IEC 61215-1:2021 / IEC 61730-1:2016 / IEC 61730-2:2016 (module design qualification & safety)2021 / 2016 / 2016TÜV Rheinland / VDE Renewables test certificate — to be supplied by Jinko on requestPENDING — manufacturer to supply certificate matching JKM420N-6RL3 SKU
IEC 61215-1-1:2021 (c-Si-specific, applies to JKM420N-6RL3)2021TÜV Rheinland — same certificate bundlePENDING
IEC 62109-1:2010 / IEC 62109-2:2011 (inverter safety)2010 / 2011TÜV Rheinland / TÜV SÜD certificate to be supplied by Sungrow for SG50CX SKUPENDING
EN 50549-1:2019 / EN 50549-10:2022 (EU generator grid interface)2019 / 2022Sungrow SG50CX type-test certificate to be supplied by SungrowPENDING — DNO/DSO acceptance evidence to be filed at commissioning
CE marking (EU Regulation (EU) 2019/1020 + Low Voltage Directive 2014/35/EU)—Jinko (modules) & Sungrow (inverters) Declarations of ConformityPENDING — DoC required per SKU
RoHS 2011/65/EU + (EU) 2015/863; WEEE 2012/19/EU—OEM DoCPENDING — supplier to provide
UN Manual of Tests and Criteria, Rev.7 (2023), §38.3 (lithium batteries — n/a here, kept for completeness)—n/a (no batteries in baseline)n/a

7. HS code & duty block

ComponentIndicative HS codeEU MFN dutyUS referenceAction
Crystalline silicon PV modules (JKM420N-6RL3)8541.43 (CN 2025; photovoltaic cells assembled in modules)0% (verify on TARIC for destination Member State and exact product description)USITC HTSUS 8541.43.00.95 — photovoltaic cells assembled into modules [S5]Look up on European Commission TARIC: https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en&Taric=8541430000
Static converters (inverters) (Sungrow SG50CX)8504.40 (static converters)0% (verify on TARIC)USITC HTSUS 8504.40.95 — static converters, other [S4]Look up on European Commission TARIC: https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp?Lang=en&Taric=8504400000
Mounting structures (aluminium / steel)7610.90 (aluminium structures) or 7308 (steel structures)Verify on TARIC per material of supplyHTSUS 7610.90.00 / 7308.90.00 [S8]Look up on TARIC: https://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp

Disclaimer: HS classifications and EU MFN duty rates shown are placeholders pending verification. EU MFN duty depends on the exact product description, destination Member State, applicable trade agreements and any anti-dumping/countervailing measures (e.g. EU Implementing Regulation (EU) 2024/1608 on anti-dumping on Chinese solar modules — re-verify current measure). Always re-verify on TARIC and confirm with the competent national customs authority before declaring. tradvolt.com does not provide customs or legal advice.

8. Call to action

Request a quotation: https://tradvolt.com/rfq/library-solar-120kwp-eu-r9/

Datasheets: Jinko Tiger Neo JKM420N-6RL3 (https://www.jinkosolar.com/uploads/2024EN/JKM420N-6RL3-F1-EN.pdf) and Sungrow SG50CX (https://en.sungrowpower.com/u/files/products/SG50CX/SG50CX_Datasheet_EN.pdf).

9. Sources table (numbered)

#Claim supportedDocumentSpecific URL
S1Specific yield band 950–1,100 kWh/kWp/yr for EU low-slope rooftopEU PVGIS (JRC) interactive tool — photovoltaic geographical information system, hourly data and typical-year mapshttps://re.jrc.ec.europa.eu/pvg_tool/en/
S2CapEx 900–1,200 EUR/kWp, inverter replacement ~120 EUR/kWp at year 12, O&M 1.0–1.5%, insurance 0.2–0.4%, rooftop segmentSolarPower Europe, "EU Market Outlook for Solar Power 2024–2028" PDF (routed via the official reports landing page)https://www.solarpowereurope.org/insights/outlooks/global-market-outlook-for-solar-power-2024-2028
S3Imported electricity price band 0.16–0.26 EUR/kWh for non-household consumers (EU), 2023–2024Eurostat dataset "Electricity prices for non-household consumers — bi-annual" (nrg_pc_205)https://ec.europa.eu/eurostat/databrowser/view/nrg_pc_205/default/table
S4Inverter HS / HTSUS classification 8504.40 / 8504.40.95USITC HTSUS — Harmonized Tariff Schedule of the United States, chapter 8504https://hts.usitc.gov/?query=8504.40
S5PV module HS / HTSUS classification 8541.43 / 8541.43.00.95USITC HTSUS — Harmonized Tariff Schedule of the United States, chapter 8541https://hts.usitc.gov/?query=8541.43
S6Module spec (420 Wp, n-type TOPCon, dimensions, weights, system voltage 1,500 V, mechanical loads, junction box IP68/MC4-EVO2, 25-year linear performance warranty)Jinko Solar — Tiger Neo JKM420N-6RL3 datasheet, English version, 2024https://www.jinkosolar.com/uploads/2024EN/JKM420N-6RL3-F1-EN.pdf
S7Inverter spec (50 kW AC, 1,100 Vdc max, MPPT 180–1,000 V, IP66, 2 MPPTs, 26 A max input current, EN 50549 conformance)Sungrow — SG50CX datasheet, English version, V1.7https://en.sungrowpower.com/u/files/products/SG50CX/SG50CX_Datasheet_EN.pdf
S8Mounting structure HTSUS references (7610.90 aluminium, 7308.90 steel)USITC HTSUS — chapters 7610 and 7308https://hts.usitc.gov/?query=7610.90 and https://hts.usitc.gov/?query=7308.90
S9EU TARIC consultation (HS 8541.43 and HS 8504.40) — duty verification at importEuropean Commission, Taxation and Customs Union — TARIC consultationhttps://ec.europa.eu/taxation_customs/dds2/taric/taric_consultation.jsp
S10Standards cited in §6 (IEC 61215, 61730, 62109, EN 50549)IEC Webstore — catalogue records for IEC 61215-1:2021, IEC 61730-1:2016 / -2:2016, IEC 61215-1-1:2021, IEC 62109-1:2010 / -2:2011; CENELEC catalogue for EN 50549-1:2019 / -10:2022https://webstore.iec.ch/en/publication/68210 (IEC 61215-1:2021) and https://webstore.iec.ch/en/publication/63816 (IEC 62109-1:2010); EN 50549 via CENELEC https://www.cenelec.eu/dyn/www/f?p=104:110:0::::FSP_ORG_ID,FSP_PROJECT,FSP_LANG_ID:1257231,69440,25
S11EU RoHS / WEEE / CE marking regulatory frame referenced in §6EUR-Lex — Directive 2011/65/EU (RoHS), Directive (EU) 2015/863, Directive 2012/19/EU (WEEE), Regulation (EU) 2019/1020, Directive 2014/35/EU (LVD)https://eur-lex.europa.eu/eli/dir/2011/65/oj and https://eur-lex.europa.eu/eli/reg/2019/1020/oj and https://eur-lex.europa.eu/eli/dir/2014/35/oj
S12UN Manual of Tests and Criteria §38.3 reference (cited as n/a — no batteries)UN Manual of Tests and Criteria, Rev.7 (2023), ST/SG/AC.10/11/Rev.7https://unece.org/transport/dangerous-goods/un-manual-tests-and-criteria